Rees_Permit_Plan Set 200321-2019034EX ROCKERY 3'-8" +/- EXI SITE PLAN SCALE 1 /8" = V-0" GENERAL NOTES THESE DRAWINGS ARE THE PROPERTY OF PACIFIC LIVING CONSTRUCTION LLC. 1. CODE - CONSTRUCTION TO CONFORM TO THE 2015 INTERNATIONAL RESIDENTIAL CODE (IRC), WASHINGTON STATE LAWS AND REGULATIONS, CURRENT WASHINGTON STATE RESIDENTIAL ENERGY CODE AND VARIOUS CODES IMPOSED BY LOCAL AUTHORITIES. - A COPY OF THE APPROVED PERMIT PLANS MUST BE ON THE JOB SITE DURING CONSTRUCTION 2. CONTRACTOR'S RESPONSIBILITY - PRIOR TO CONSTRUCTION CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND STRUCTURAL MEMBER SIZES - DO NOT SCALE CONTRACT DOCUMENTS - ALL WORK MUST FOLLOW CURRENT RRP RULES AND REQUIREMENTS AS DEFINED BY THE EPA AND THE STATE OF WASHINGTON - ALL WASTE AND REFUSE CAUSED IN CONNECTION WITH THE WORK SHALL BE REMOVED FROM THE PREMISES AND DISPOSED OF BY THE CONTRACTOR - CONTRACTOR SHALL DESIGN AND INSTALL SHORING AS REQUIRED TO PERFORM WORK CENTER OF R.O.W. 3. SOILS - FOUNDATION DESIGN IS BASED ON AN ASSUMED AVERAGE SOIL BEARING OF 1,500 PSF OR PER GEOTECHNICAL REPORT. ALL FOOTINGS SHALL BE CAST ON UNDISTURBED FIRM NATURAL SOIL OR COMPACTED SOIL OF 1,500 PSF BEARING CAPACITY AT LEAST V-6" BELOW LOWEST ADJACENT GRADE, AND FREE OF ORGANIC MATERIALS. FOOTING EXCAVATION SHALL BE FREE OF LOOSE SOILS, DEBRIS, AND FREE WATER AT ALL TIMES. 4. STAIRS - MINIMUM HEADROOM 6-8"; MINIMUM TREAD 10"; MAXIMUM RISER 7 3/4" - HANDRAIL: REQUIRED AT ALL STAIRS WITH MORE THAN 4 RISERS PER IRC 311.7.8. MINIMUM 34" AND MAXIMUM 38" ABOVE TREAD NOSING. OPEN SIDES OF STAIRS MORE THAN 30" ABOVE ADJACENT FLOOR SHALL HAVE HANDRAILS AND GUARDRAILS. HANDRAIL TO BE 1 1/4"-2" CROSS SECTIONAL DIMENSION AND 1 1/2" AWAY FROM WALL. - GUARDRAIL: SHALL BE MIN 36" IN HEIGHT WHERE ADJACENT SURFACE GRADE IS 30" OR MORE BELOW. RAILINGS SHALL BE SPACED TO NOT ALLOW THE PASSAGE OF A 4" SPHERE PER IRC 312.1. PROJECT INFORMATION PROJECT OWNER JASON AND HEATHER REES 736 FIR ST EDMONDS, WA 98020 PROJECT DESIGNER SANDRA PIEDRAHITA PACIFIC LIVING CONSTRUCTION LLC PO BOX 15841 SEATTLE, WA 98115 206.678.5478 STRUCTURAL ENGINEER CG ENGINEERING 250 4TH AVE S, SUITE 200 EDMONDS, WA 98020 425.778.8500 PROJECT DESCRIPTION NEW DECK AND STAIRS PROJECT ADDRESS: 736 FIR ST CENTER OF EDMONDS, WA 98020 R.O.W. TAX LOT NUMBER: 00619401000101 VICINITY MAP (NTS) Edmonds - 4CingstonPeir Brackett's �L',a ding North Edmonds Main St Dayton St a A Yost Park Marina Edmonds n B,"��o. Beach Park City Park n ry U 10 736 Fir Street 226th St SW i CD Zn n � Woodway LEGAL DESCRIPTION: Section 25 Township 27 Range 03 Quarter NW - YOSTS 1 ST ADD TO EDMONDS PLAT OF BILK 010 D-01 - N1/2 LOT 1 AKA PAR A OF CITY OF ED SHORT SUB NO S-56-76 REC AFN 7610280127 BEING A PTN OF LOT 1 BLK 10EXST PLAT LAND USE ZONE: RS-6 LOT COVERAGE: LOT AREA: EXISTING HOUSE: EXISTING GARAGE: EXISTING DECK: NEW DECK: PROPOSED LOT COVERAGE ALLOWED LOT COVERAGE: SETBACKS: STREET SETBACK REAR SETBACK: SIDE SETBACK: SHEET INDEX 7,500 SF 1,498 SF 664 SF 380 SF 430 SF 2,592 SF 7500 x 35% = 2,625 SF..OK 20' 15' 5' A0.1 SITE PLAN, NOTES A1.1 MAIN FLOOR PLAN A2.1 ELEVATIONS, STAIR DETAIL, SECTION S1.1 STRUCTURAL NOTES S2.1 DECK FRAMING PLAN AND DETAILS PACIFIC LIVING CONSTRUCTION LLC P.O. Box 15841 Seattle, WA 98115 t: 206.678.5477 www.pacificlivingconstruction.com Project Title: REES RESIDENCE 736 FIR STREET EDMONDS, WA 98020 Project No.: 2019034 Drawn By: SIP Issue PERMIT Date: 03.12.2020 Scale: 1/8" = 1'-0" Sheet Size: 24" x 36" Title Sheet No.: SITE PLAN AO.1 14'-011 O O 0 z - o 1 _ T DECK T DECKING OVER o L" T WATERPROOF DECK 00 X N p 00 00 T u J 1 M� `o 0 r SLOPE DECK T 1 /4":12 FIXED WINDOWS 24-1/2" ABOVE DECK SURFACE _ EXTERIOR co LIGHT SOURCE LO ® LO T 0 T FIXED WINDOW � 36" ABOVE DECK SURFACE = - ® ® 01 X4 PT 1 LJ DN co ® 91 X4 PT EXTERIOR LIGHT SOURCE 3'-6" 5-117/8" 41-911 MIN. 36" X 36" LANDING 14'-75�8" MAIN FLOOR PLAN 1 /411 = 1'-011 PACIFIC LIVING CONSTRUCTION LLC P.O. Box 15841 Seattle, WA 98115 t: 206.678.5477 www.pacificlivingconstruction.com Project Title: REES RESIDENCE 736 FIR STREET EDMONDS, WA 98020 Project No.: 2019034 Drawn By: SP Issue PERMIT Date: 03.12.2020 Scale: 1 /4" = 1 '-011 Sheet Size: 2411 x 3611 Title MAIN FLOOR PLAN Sheet No.: A1.1 NORTH ELEVATION 1/4" = 1'-0" STAIR DETAIL 1 /2" = 1'-0" WEST ELEVATION 1/4" = 1'-0" DECK SECTION 1 /2" = 1 '-0" RPROOFING Y UPPER AND STRIP �L VENT SOFFIT COLUMN JRAL �J L i FOOTING PER STRUCTURAL PACIFIC LIVING CONSTRUCTION LLC P.O. Box 15841 Seattle, WA 98115 t: 206.678.5477 www.pacificlivingconstruction.com Project Title: REES RESIDENCE 736 FIR STREET EDMONDS, WA 98020 Project No.: 2019034 Drawn By: SIP Issue PERMIT Date: 03.12.2020 Scale: AS NOTED Sheet Size: 24" x 36" Title ELEV, STAIR, SECTION Sheet No A2.1 STRUCTURAL NOTES C3�J (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) CODE REINFORCING STEEL ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615, AND SHALL BE GRADE 60 (Fy SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. SPECIFICATIONS AND STANDARDS = 60,000 PSI), UNLESS NOTED OTHERWISE. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615 MAY BE WELDED IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D1.4 ARE DESIGN LOADS SUBMITTED. DEAD LOADS: WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. PROVIDE WELDED WIRE FABRIC IN SHEETS NOT ROLLS. LAP ROOF 15 PSF WELDED WIRE FABRIC 12" AT SIDES AND ENDS. DECK 10 PSF REINFORCING STEEL SHALL BE DETAILED INCLUDING HOOKS AND BENDS IN ACCORDANCE WITH SP-66 AND ACI LIVE LOADS: 318R, LATEST EDITIONS. UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS ROOF (SNOW LOAD) 25 PSF SHALL BE PER SCHEDULE. DECK 60 PSF MECHANICAL SPLICING OF REINFORCING BARS, WHERE INDICATED ON THE DRAWINGS, SHALL BE BY AN ICBO (LIVE LOADS ARE REDUCED WHERE PERMISSIBLE PER IBC SECTION 1607.10). APPROVED SYSTEM, SHALL DEVELOP 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR, AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. EARTHQUAKE LOADS: EQUIVALENT LATERAL FORCE PROCEDURE PER ASCE 7-10 SECTION 12.8. SITE CLASS (ASSUMED) D SHORT PERIOD SPECTRAL RESPONSE ACCEL (SS) 1.265 ONE SECOND SPECTRAL RESPONSE ACCEL (Si) 0.495 SHORT PERIOD DESIGN SPECTRAL RESPONSE ACCEL (SIDS) 0.843 ONE SECOND DESIGN SPECTRAL RESPONSE ACCEL (SDI) 0.495 RISK CATEGORY II SEISMIC IMPORTANCE FACTOR 00 1.0 SEISMIC DESIGN CATEGORY D BASIC SEISMIC FORCE -RESISTING -SYSTEM CANT WOOD COLUMNS RESPONSE MODIFICATION FACTOR, (R) 1.5 REDUNDANCY FACTOR (p) 1.0 SEISMIC RESPONSE COEFFICIENT (CS) 0.562 W = TOTAL SEISMIC DEAD LOAD AS DEFINED PER ASCE 7-10 SECTION 12.7.2 BASE SHEAR (V), V = CSW = ID RI W WIND LOADS: BASIC WIND SPEED (3 SECOND GUST) 110 MPH EXPOSURE B KZT 1.0 SEE PLANS FOR ADDITIONAL DESIGN LOADS. FOUNDATIONS: SPREAD FOOTINGS SOILS REPORT: REPORT NOT AVAILABLE AT TIME OF DESIGN ALLOWABLE SOIL PRESSURE LATERAL EARTH PRESSURE: UNRESTRAINED: RESTRAINED: PASSIVE: COEFFICIENT OF FRICTION 1500 PSF 35 PCF + ANY APPLICABLE SURCHARGE 50 PCF + ANY APPLICABLE SURCHARGE 300 PCF 0.35 FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR 12" OF COMPACTED STRUCTURAL FILL AS REQUIRED AND AT LEAST 18" BELOW ADJACENT EXTERIOR GRADE. ANY FOOTING ELEVATIONS SHOWN IN THE DRAWINGS REPRESENT MINIMUM DEPTHS AND ARE FOR BIDDING ONLY. ACTUAL FOOTING ELEVATIONS ARE SUBJECT TO SITE CONDITIONS AND MUST THEREFORE BE ESTABLISHED BY THE CONTRACTOR. FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE, UNLESS NOTED OTHERWISE. IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MAXIMUM PARTICLE DIAMETER OF THREE INCHES AND NO MORE THAN 10% FINES (PASSING THE #200 SIEVE). FILL AND BACKFILL MATERIAL SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE (12") INCHES IN LOOSE THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AS DETERMINED BY ASTM TEST METHOD D1557-00. BACKFILL BEHIND ALL RETAINING WALLS WITH WELL -DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. PROVIDE DAMPPROOFING AT EXTERIOR FACE OF ALL FOUNDATION WALLS EXPOSED TO EARTH PER ARCHITECTURAL SPECIFICATIONS. EXCAVATIONS AND DRAINAGE INSTALLATION SHALL BE OBSERVED BY A SOILS ENGINEER RETAINED BY THE OWNER IF EXCAVATION SHOWS SOIL CONDITIONS TO BE OTHER THAN THOSE ASSUMED ABOVE NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. ,�I�7►101C7:1119: ALL CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH CHAPTER 26 OF ACI 318 AND THE AMERICAN CONCRETE INSTITUTE'S SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301). ALL CONCRETE SHALL BE STONE -AGGREGATE CONCRETE HAVING A UNIT WEIGHT OF APPROXIMATELY 150 POUNDS PER CUBIC FOOT. CONCRETE STRENGTHS AT 28 DAYS (fc) AND MIX CRITERIA SHALL BE AS FOLLOWS: MAXIMUM MIN CEMENT TYPE OF CONSTRUCTION f'c* WATER/CEMENT CONTENT PER CUBIC MAXIMUM SHRINKAGE STRAIN RATIO YARD SLABS ON GRADE 3000 PSI 0.55 5 1/2 SACK N/A FOOTINGS 3000 PSI 0.55 5 1/2 SACK N/A WALLS 4000 PSI 0.45 5 1/2 SACK N/A THE MINIMUM AMOUNT OF CEMENT LISTED ABOVE MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH CHAPTER 26 OF ACI 318. ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR -ENTRAINED IN ACCORDANCE WITH ACI 318 TABLE 19.3.3.1 FOR MODERATE EXPOSURE CLASS F1. *PROVIDE f'c SPECIFIED IN TABLE FOR DURABILITY REQUIREMENTS. 2500 PSI CONCRETE MEETS STRENGTH REQUIREMENTS, THEREFORE SPECIAL INSPECTION IS NOT REQUIRED. REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET -SETTING EMBEDDED ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. REFER TO CHAPTER 7 OF ACI 318 FOR OTHER REINFORCING STEEL REQUIREMENTS. CONCRETE COVER ON REINFORCING CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" CONCRETE EXPOSED TO EARTH AND WEATHER: #6 BARS AND LARGER 2" #5 BARS AND SMALLER 1 1/2" CONCRETE NOT EXPOSED TO EARTH OR WEATHER: SLABS, WALLS AND JOISTS 3/4" COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1 1/2" CONCRETE GENERAL NOTES VERTICAL BARS SHALL START FROM TOP OF FOOTING. HORIZONTAL BARS SHALL START A DISTANCE OF 1/2 THE NORMAL BAR SPACING FROM TOP OF FOOTING AND TOP OF FRAMED SLABS. IN ADDITION, THERE SHALL BE A HORIZONTAL BAR AT A MAXIMUM OF 3" FROM TOP OF WALL AND BOTTOM OF FRAMED SLABS. PROVIDE CORNER BARS TO MATCH THE HORIZONTAL REINFORCING WITH TENSION LAP SPLICE AT EACH SIDE PER TABLE, OR BEND ONE SIDE OVER TO PROVIDE TENSION LAP. PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS ON GRADE TO BREAK UP SLAB INTO RECTANGULAR AREAS OF NOT MORE THAN 400 SQUARE FEET EACH. AREAS TO BE AS SQUARE AS PRACTICAL AND HAVE NO ACUTE ANGLES. JOINT LOCATIONS TO BE APPROVED BY THE ARCHITECT. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED BEYOND JOINT. SEE ARCHITECTURAL DRAWINGS AND MECHANICAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF OPENINGS IN CONCRETE WALLS, FLOORS AND ROOF. UNLESS INDICATED OTHERWISE, REINFORCE AROUND OPENINGS GREATER THAN 12" IN EITHER DIRECTION WITH (2) #5 EACH SIDE AND (1) #5 x 4'-0" DIAGONAL AT EACH CORNER. EXTEND BARS T-0" BEYOND EDGE OF OPENING. IF T-0" IS UNAVAILABLE, EXTEND AS FAR AS POSSIBLE AND HOOK. HOOK ALL REINFORCING INTERRUPTED BY OPENINGS. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE AND OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES. PROVIDE 3/4" CHAMFER AT ALL CORNERS EXCEPT AS NOTED. LUMBER ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fc (PSI) SLEEPERS DOUG-FIR STUD 700 - LIGHT FRAMING (STUDS) HEM -FIR STUD 675 800 2x JOISTS AND PLANKS HEM -FIR #2 850 - PLATES AND BLOCKING HEM -FIR #2 850 - 6x AND LARGER BEAMS AND STRINGERS DOUG-FIR #2 875 - 4x AND SMALLER BEAMS AND STRINGERS HEM -FIR #2 850 - ALL POSTS AND TIMBERS DOUG-FIR 1 #1 1200 1000 REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1. NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: NAIL SHANK 0 MIN LENGTH 8d COMMON 0.1310 2 1/2" SHANK 10d COMMON 0.1480 3" SHANK 12d COMMON 0.1480 3 1/4" SHANK 16d COMMON 0.1620 3 1/2" SHANK 10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148" 0 x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE SHANK AND THREADED PORTIONS PER NDS 11.1.3. CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS, SCREWS, OR BOLTS IN EACH MEMBER. INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. GALVANIZATION UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED ACCORDING TO THE FOLLOWING TABLE: GALVANIZATION UNTREATED WOOD CCA-C SBX ACQ-C ACQ-D CBA-A CA-B OTHER BORATE ACZA OTHER PT WOOD G90 X X X G 185 X X X X X X HDG X X X X X X STT300 X X X X X X X X G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA HDG = HOT DIP GALVANIZED SST300 = TYPE 316L STAINLESS STEEL RATED SHEATHING RATED SHEATHING SHALL BE GRADE C-D INT-APA WITH EXTERIOR GLUE OR OSB SHEATHING WITH EXTERIOR GLUE IN CONFORMANCE WITH IBC STANDARD 2303.1.4. TIMBERSTRAND, MICROLLAM, AND PARALLAM MEMBERS FABRICATED IN CONFORMANCE WITH THE INTERNATIONAL CODE COUNCIL EVALUATION SERVICE (ICC-ES) REPORT NO. ESR-1387 OR CCMC REPORT NO. 12627-R, 08675-R, AND 11161-R. EACH MEMBER SHALL BE IDENTIFIED BY A STAMP INDICATING THE PRODUCT TYPE AND GRADE, ICC-ES OR CCMC REPORT NUMBER, MANUFACTURER'S NAME, PLANT NUMBER AND INDEPENDENT INSPECTION AGENCY'S LOGO. FABRICATOR SHALL BE CERTIFIED. MEMBERS SHALL MEET THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fv (PSI Fc (PSI) BEAMS & POSTS (d < 9 1/2") LSL 1.3E 1,700 425 1,835 RIMS & BEAMS (d >_ 9 1/2") LSL 1.55E 2,325 310 - BEAMS & POSTS LVL 2.0E 2,600 285 2,510 POSTS (d < 9 1/2") PSL 1.8E 2,400 190 2,500 BEAMS (d >_ 9 1/2") PSL 2.0E 2,900 290 1 - TIMBERSTRAND, MICROLLAM, AND UNTREATED PARALLAM MEMBERS ARE INTENDED FOR DRY -USE APPLICATIONS. UNLESS NOTED OTHERWISE, ENGINEERED WOOD BEAMS EXPOSED TO WEATHER SHALL BE TREATED PER MANUFACTURES RECOMMENDATIONS. GLUE -LAMINATED TIMBER GLUE -LAMINATED TIMBER SHALL BE DOUGLAS FIR, FABRICATED IN CONFORMANCE WITH ANSI/AITC STANDARD A190.1, LATEST EDITION. EACH MEMBER SHALL BEAR AN AITC IDENTIFICATION MARK AND SHALL BE ACCOMPANIED BY AN AITC CERTIFICATE OF CONFORMANCE. FABRICATOR SHALL BE CERTIFIED. MEMBERS SHALL BE OF THE FOLLOWING MINIMUM STANDARDS: SPAN COMBINATION Fb SIMPLE SPAN BEAMS 24F-V4 2400 PSI CANTILEVER OR MULTI -SPAN BEAMS 24F-V8 2400 PSI EXISTING BUILDING ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 J a F— F— Z 0 m (Z N D' ~ U � (n � w w 0 d W I I / 2020 CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING Y DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. Q CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS DESIGN: LAT PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. DRAWN: ATD GENERAL CHECK: CMJ STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND JOB NO: 20065.10 MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE DATE: 03/1 1 /2020 ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. V W Y U O O w N o O Z 00 Ld 0") t Q Z W Q W 0 � N V)� o U U— Z :D CO uj w L z J SHEET: Simi DECK FRAMING PLAN SCALE: 1/4" = V-0" TYPICAL DECK FRAMING PLAN NOTES: 1. DECK SHEATHING SHALL BE 3/4" PI 48/24 WITH 10d COMMON NAILS SPACED AT 6" OC AT ALL DIAPHRAGM BOUNDARIES, PANEL EDGES AND SHEAR WALLS AND 10" OC AT INTERMEDIATE FRAMING. FOR SHEATHING LAYOUT AND NAILING REFER TO DETAIL 3. 2. PROVIDE SIMPSON HUC HANGERS AT ALL BEAM TO BEAM CONNECTIONS UNO. 3. PROVIDE EXTERIOR GRADE GLULAM BEAMS 2'-0" 0 2'-0" 4'-0" NOTE: STAGGER SHEATHING AS SHOWN. (IBC TABLE 2306.3.1, CASE 1 SHEATHING PANEL, TYP PAVING OR SLAB ON COL PER PLAN BURIED CONTINUOUS GRADE SIDEWALK FULL DEPTH OF PILE PANEL EDGES PER ARCH SECTION SCALE: 1" = V-0" GUARDRAIL POST AND CONNECTION BY OTHERS COUNTERSINK BOLT THIS END BEAM PER PLAN DECK SECTION SCALE: 1" = V-0" 24"0 x 4'-3" DEEP DRILLED CONC SHAFT SUPPORTED PANEL EDGES 2x OR 3x BLOCKING ONLY IF BLOCKED DIAPHRAGM it rnrri rirn (SHEAR WALL, BEAM, OR DRAG STRUT) TYPICAL FLOOR/ ROOF SHEATHING DETAIL SCALE: NTS DECKING OVER GUARDRAIL POST SLEEPERS PER ARCH AND CONNECTION SHEATHING AND NAILING BY OTHERS PER PLAN NOTES COUNTERSINK ALIGNED JOIST AT BOLT THIS END GUARDPOST LOCATIONS W/ (1) SIMPSON DTT2Z TENSION TIE DECK JOIST PER PLAN; SLOPE PER ARCH BEAM PER PLAI SIMPSON LUS HANGER DECK SECTION SCALE: 1" = V-0" OVER PER ARCH AILS PER BLOCK PT 2x12 HF#2 LEDGER; ATTACH TO EXIST RIM W/ (3) SIMPSON 1/4" 0 x 3" SIDS SCREWS @ 12" OC ALIGNED BLKG AT GUARDPOST LOCATIONS W/ (1) SIMPSON DTT2Z TENSION TIE ING; (4) BAYS MIN LUS HANGER ATTACH JOIST TO CONT LEDGER W/ SIMPSON LUS SERIES HANGERS DECKING OVER SLEEPERS PER ARCH SHEATHING AND NAILING PER PLAN NOTES DECK JOIST PER PLAN; / 311 SLOPE PER ARCH J SIMPSON DTT1Z @ 6'-0" MIN OC MAX W/ (1) 3/8" 0 SIMPSON SDWH DECK SECTION SCALE: 1" = V-0" 8"x8" CONCRETE PLINTH W/ (4) #3 TIES EQ SPACED (4) #4 HOOKED Bo DOWELS 6" z �2 0 m V-6" ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 W 1 / 2020 J a H H z 2 0 m I'I EXIST HOUSE I- N FRAMING w H U � w w O w _ Q C) \ m EXIST JOISTS O 7rY Q DESIGN: LAT DRAWN: ATD CHECK: CMJ JOB NO: 20065.10 DATE: 03/ 1 1 /2020 COL PER PLAN AND SCHED SIMPSON ABU POST BASE SLAB ON GRADE AND SUBGRADE PER FOUNDATION PLAN W/ THICKENED FOOTING AT EDGE (2) #4 BOT, EA WAY TYPICAL DECK FOOTING DETAIL SCALE: 1" = V-0" 0 Q W 0 Z Q � U � Wcl N !!^^ V 00 V W � Z W Q W Q V/ V) �/Ld �w V / 11Y cl w O (o :2U W w z W 0 J SHEET: S201