Loading...
FIR2022-0083+Approved_Regional_Fire_Marshals_Mobile_Food_Vehicle_Inspection_Checklist+8.25.2022_10.34.23_AM+3072230 (2)F I R2022-0083 RECEIVED 26 2022 CiT OFSOMONDS Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Project #: Q497 PLANS & SPECIFICATIONS Manufactured by Quality Trailers Inc. 971-220-2626for La Casa De Amigos LLC 626-766-5121 Index of Sheets Index # Sheet Name Sheet # 0. Cover Sheet & Index of Sheets 1 1. Floor Plan 2-3 la. Floor Plan Legend - Equipment & Finishes 2-3 2. Electrical Floor Plan, Circuit Diagram & Panel Schedule 4 3. Plumbing Riser and Waste Drainage Diagrams 5 4. Propane Floor Plan 6 5 Fire Suppression System Perspective View 7-8 6. Fire Suppression System Design Specification 7-8 7. Cross Sections I & II 9 8. Cross Section III 10 9. Cross Section IV 11 10. Perspective Cross Section I 12 11. 1 Perspective Cross Section II 13 12. Elevation Views 14 13. Front Perspective Views 15 14. Rear Perspective Views 16 15. Appendix A - Codes Specific Requirements 1 - 2 15a. Appendix A (cont) - Codes Specific Requirements 2-2 16. Appendix B - Equipment Specification Sheets 1 - 46 The plans are compliant with but not limited to the current version of the applicable codes referenced in WAC 296-150-800, as follows: WAC 296-150V Conversion Vendor Units & Medical Units - 2018 IBC International Building Code w/ 51-50 WAC & Chapt. 11 - 2018 IMC International Mechanical Code w/ 51-52 WAC 2020 NEC National Electrical Code CH. 551/552 - 2018 UPC Uniform Plumbing Code AMEND. 19.27 - 2018 IFC International Fire Code - 2018 IFGC International Fire Fuel Gas Code - 2018 ANSI/RVIA Standard for Low Voltage Systems in Conversion & RV's - NFPA 58, LP Gas Code ANSI/NFPA 1192, Standards on Recreational Vehicles (RV), Chapter 7 - NFPA 96 Standard for Ventilation Control & Fire Protection of Commercial Cooking Operations Washington State Building Code Amendments / WAC i.e. IBC, IMC, IFC, IFGC & UPC Washington State Motor Vehicle Laws Title 46 RCW 0. Cover Sheet & Index of Sheets Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Sheet 1 of 16 1 1 Date: 4/21/2022 1 Revision Date WA Project #:Q497 1 Quality Trailers Inc. Scale: sales@qualityfoodtrailers.com / (971) 220-2626 8'-6" 17" I'll Dimensions - o Hood extension a beyond the extent of cooking appliances r---- I I i I I I n 6a I I I I I I L 1. Floor Plan Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Sheet 2 of 16 Date: 4/21/2022 Revision Date: Project #:Qas7 , Quality Trailers Inc. Scale: 1/2"=l'-0" W sales@qualityfoodtrailers.com / (971) 220-2626 EQUIPMENT & FINISHES A - Structural* 1a. Double axle 20'L x 8.5'W trailer / 7,000 lb. 95" straight axles, E-rated tires, electric brakers & breakaway kit 2a. (2) Tank cages & (2) empty steel LP cylinders w/ multi -valve 3a. 4ft Tongue & 2-5/16" ball hitch, jack stand & safety chains 4a. (4) Stabilizer scissor jacks welded to all corners of chassis 5a. Entry door / 36"W x 72"H 6a. (2) Operable window awning / 72"W x 36"H & 72"W x 24"H 7a. Plexiglass concession window / 72"W x 36"H w/ horizontal sliding opening / 20"W x 20"H 8a. Solid plexiglass window / 72"W x 24"H B - Propane equipment 1 b. 33" 2-Well steam table / Eagle Group HT2-LP 2b. 36" Griddle / Imperial IMGA-3628-1 3b. 18" Radiant broiler / Stratus SRB-18 4b. 24" 4-Open burner / Imperial IHPA-4-24 5b. (2) 15-1/2" Deep fryer / Imperial IFS-40 w/ (1) stainless steel splash guard w/ rounded edges C - Refrigeration equipment 1c. Refrigerator/ Everest EBR1 2c. Undercounter freezer / Everest ETF1 3c. Sandwich prep table / Everest EPR2 4c. Chef base / Everest ECB82D4 incl. a shunt -trip breaker D - Electrical equipment 1 d. 125A electrical panel & 50A shore power inlet 2d. 25ft 50A power cord / Reliance Controls 3d. Water heater / Rheem-Ruud EGSP10 4d. Water pump / SHURflo 2088-594-154 5d. 10' Ventilation hood / Captive Aire 3044 BD-2 & Exhaust fan / Captive Aire DU85HFA 6d. Makeup air fan / Captive Aire DMUAI8FA 7d. Air conditioner 15000 BTU E - Plumbing equipment 1 e. 75" Three -compartment sink / 15"W x 15"L x 12"D basins w/ dual drainboard 2e. 17" Hand sink / 10"W x 14"L x 5" D basin w/ dual splash guards 3e. Soap & paper towel dispensers 4e. Potable water tank / 80 Gal. / Custom Rotomolding W-426 5e. Wastewater tank / 135 Gal. / Custom Rotomolding GWT-135 6e. (2) Potable water inlets (incl.direct) w/ 3/4" swivel connect w/ backflow prevention valve in a lockable box 7e. Pre -rinse assembly for 3-compartment sink 8e. 20" Prep sink / 15"W x 15"L x 12"D basin F - Fire protection If. Amerex restaurant fire suppression system 2f. (2) Amerex fire extinguishers / B260 2A;K & B402 A,B,C G - Finishes 1 g. Stainless steel work / prep surface / 23"D x 35"H 2g. Stainless steel work / prep surface / 29"D x 35"H 3g. Stainless steel storage shelving w/ lip 4g. (2) H.C. self-service shelf 48"H from the ground H - Additional Features 1 h. (4) Vent through wall for refrigeration equipment 2h. Wiring for (2) interior & (4) exterior cameras. Cameras & hard drives to be provided & installed by the customer 3h. Platform for a future generator inlc. propane, electrical lines & transfer panel *Others • Laminated subflooring, pre -undercoated shiplapped 1-1/8" hardwood • Polished stainless steel interior walls on 5/8" exterior grade CDX plywood sheathing • Stainless steel ceiling • 18-gauge riveted aluminum exterior walls • Electrical wiring inside walls • Stainless steel cabinetry • Equipment secured to the wall/floor w/ stainless steel/aluminum brackets & screws • All appliances & equipment are installed per manufacturer's installation instructions & secured against displacement • Diamond -plate aluminum flooring moisture resistant w/ seamless welded 3/8" radius base cove • Seams of the stainless -steel walls/counters are filled w/ food grade caulk 1 a. Floor Plan Legend - Equipment & Finishes Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Sheet 3 of 16 1 1 Date: 4/21/2022 1 Revision Date Project #: 0497 Scab ��. Quality Trailers Inc. sales@qualityfoodtrailers.com / (971) 220-2626 Service: 50A 240V Voltage: 120V / 240V PANEL SCHEDULE Rating: 125A Enclosure: Eaton Type BR 125A Nr. of circuits: 16 1 Phase, 4 Wire Load Name VA V Amp FDR Size CB Amp CKT CKT CB Amp FDR Size Amp V VA Load Name A I B A B Utility neutral switch 0 0 0 6 50 01 02 50 6 0 0 0 Generator neutral switch Main utility breaker 0 0 0 6 50 03 04 50 6 0 0 0 Generator utility breaker Main utility breaker 0 0 0 6 50 05 06 50 6 0 0 0 Generator utility breaker Refrigerator / Sandwich PT 8641 120 7.2 12 20 07 08 20 12 16.7 120 2004 Water heater Exhfan/Makeup Fan/Lights 1644 120 13.7 12 20 09 10 20 12 16.0 120 1920 A/C Outlets 540 120 4.5 12 20 11 12 20 12 0 0 0 Amerex FSS assembly Freezer 240 120 2.0 12 20 13 14 - - Shunt trip breaker LED lights / Pump 264 120 2.2 12 20 15 16 20 12 2.0 120 240 Chef base VA A: 3804 Amps A: 31.7 kW A: 3.8 B: 3912 B: 32.6 B: 3.9 Total VA A+B: 7716 Total Amps A + B: 64.3 Total kW A + B: 7.7 NOTE: Wiring for (2) interior & (4) exterior cameras. Cameras & hard drives to be provided & installed by the customer. (2) Interior & (4) exterior cameras 120V 167A UnderR—er 120V / 2.OA J-box for a future generator Makeup air fan 115V / 3.5A 12/14 Electrical Plan Legend Duplex oultet below counter Duplex oultet above counter Fourplex oultet below counter Fourplex oultet above counter Duplex oultet below counter GFCI w/ GFCI device Duplex oultet above counter Fci w/ GFCI device l p 1 Fourplex oultet below counter GFci w/ GFCI device Fa Fourplex oultet above counter w/ GFCI device Waterproof duplex outlet wP below counter Waterproof duplex outlet wP above counter 50A inlet m6 4 Switch - 50A panel at exterior WH Water heater © Water pump Exhaust fan j Circuit number LED light 12-AWG rigid metal conduit mounted to inside face of trailer wall 8-AWG copper bonding conductor between panel and chassis 2. Electrical Floor Plan, Circuit Diagram & Panel Schedule Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Project #: 0497 11 Quality Trailers Inc. Sheet 4 of 16 Date: 4/21/2022 Revision Date: Scale: 3/8"=l'-0" V sales@qualityfoodtrailers.com / (971) 220-2626 Direct potable water inlet Potable wate tank overflot 80 gal. potable water tanH Hand sink Prep sink Pre -rinse assembly Three -basin sink Drain waste vent through roof Pressure relief valve through floor 3. Plumbing Riser & Waste Drainage Diagrams Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Sheet 5 of 16 Date: 4/21/2022 Revision Date: The lenght of the pipe from the potable water tank location to the furthest appliance served Wastewater tank outlet 3" Bladex valve Legend P Water pump WH Water heater F Faucet DIOCI Ball valve I Drain YIndirect drain V ABS in -line vent P-trap 3/4" CPVC water line (up to water tank) 1/2" CPVC water line 1/2" CPVC water line (tank bypass) Cold water line (1/2" Zurn pax tubing) Hot water line (1/2" Zurn pax tubing) _ _ _ — Flexible metal hot water line at first 18" after water heater Waste water line (2" PVC) The total length of the pipe from the tank location to the furthest appliance served is 1 V-3". Project #: 0497 , Quality Trailers Inc. Scale: 1/2"=1'-0" %V sales@qualityfoodtrailers.com / (971) 220-2626 AC Ventilation h Upb exhaust Amerex mechanic, shut-off w Vertical drip below f Black iron L supply line bo to steel cha (2) 100lbs. supply lockable c (2) Main shut-o LP connect future generator 4. Propane Floor Plan Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Sheet 6 of 16 Date: 4/21/2022 Revision Date: (2) Amerex fire extinguishers Amerex manual pull station Amerex fire suppression system Griddle Radiant broiler 4-Open burner (2) Deep fryers LPG Appliance LPG Consumption* LPG Availability 2-Well steam table -agle Group HT2-LP 7,000 BTU/hr Propane / PT 3riddle mperial IMGA-3628-1 90,000 BTU/hr (1) PT=1001bs: 23.6 gal. (2) PT=200lbs: 47.2 gal. 3adiant broiler Stratus SRB-18 45,000 BTU/hr 1 gallon of LPG produces 91,333 BTUs t-Open burner heat energy per hour mperial IHPA-4-24 128,000 BTU/hr 91,333x47.2=4,310,918 2) 15-1/2" Deep fryer 105,000 BTU/hr mperialIFS-40 105,000 BTU/hr TOTAL 480,000 BTU/hr 4,310,918 BTU NOTE: The data represent the total LPG demand of appliances operating d full capacity Propane Plan Legend oc< Ball valve (Legend T-3005) ORegulator (Fisher R232A-BBF) ASTM A53 type E grade B 1" steel pipe '- Flexible stainless steel supply line Total approx. length of piping: 28' Amerex Restaurant Fire Suppression System installed per manufacturer's specifications. Project #:Qas7rL Quality Trailers Inc. Scale: 1/2"=1'-0" sales@qualityfoodtrailers.com / (971) 220-2626 KITCHEN & HOOD SYSTEM AMEREX RESTAURANT FIRE SUPPRESSION SYSTEM Distribution Network w/ (9) discharge nozzles Amerex Mechanical Release Assembly t— ^l— (2) 3.75 Gallon Agent Cylinder w/ Amerex Kitchen We --' Chemical in compliance w/ IFC Sec. 904.5 (wet system) TIIIIOTAL FLOW POINTS USED - 16 MAXIMUM ALLOWED BY THIS SYSTEM - 22 ALL PIPE & FITTINGS 5/8 OD STAINLESS STEEL DETECTOR BRACKETS ARE PLACED ON MAX. 24"' CENTER TO CENTER DISTANCE STARTING AT MAX. 24" FROM THE END OF THE HOOD & ENDING AT MAX. 24" ZONE OF PROTECTION MEASURES 30" DEEP` BY THE LENGTH OF THE PROTECTED HOOD DISCHARGE NOZZLES ARE LOCATED AT MAX. 6" //fi /NY,I EACH END OF THE HOOD, MAX. 20" THOSE IN BETWEEN & ALL 46" -.51" ABOVE THE TOP SURFACE OF APPLIANCES FOR EACH DISCHARGE NOZZLE OF APPLIANCES (2) FLOW POINTS ARE ASSIGNED WHILE FOR PLENUM & DUCT (1) POINT EACH 1 Fire Suppression System Perspective View Upblast exhaust fan Detection Network w/ (5) detector brackets w/ (5) 360oF fusible links _—_ Makeup Air Fan n 10' Ventilation hood Amerex Manual Pull Station mounted in path of egress no higher than 48 inches from the floor & (2) fire extinguishes _included (not shown in the (6) LP appliances Shut-off Valves incl. for 2-Well steam table I I TOTAL DETECTOR BRACKETS - 5 TOTAL DISCHARGE NOZZLES - 9. INCL.: LPG APPLIANCE PROTECTION - 7 PLENUM PROTECTION - 1 DUCT PROTECTION - 1 Amerex Mechanical Shut-off Valve Right side zoomed view n Shut-off Valve �J _N N U N Q N 0- N 07 C O N Q Q 07 N IL s KITCHEN & HOOD SYSTEM AMEREX RESTAURANT FIRE SUPPRESSION SYSTEM CITY SYMBOL DESCRIPTION BRAND / MODEL 2 3.75 Gallon Stored Pressure Wet Chemical Amerex 375 1 Mechanical Release Module Amerex 1 6liter Fire Extinguisher (2-A;K) Amerex B260 1 5lb. Fire Extinguisher (A,B,C) Amerex B402 1 Manual Pull Station Amerex 1 Mechanical Shut -Off Valve Amerex 5 Detector Brackets for Appliances & Duct Amerex P/N 12508 1 Discharge Nozzle for Exhuast Duct Amerex P/N 16416 1 Discharge Nozzle for Plenum Amerex P/N 11982 Discharge Nozzle for Griddle Amerex P/N 14178 Discharge Nozzle for Radiant broiler Amerex P/N 14178 7 Discharge Nozzle for 4-Open burner Amerex P/N 14178 Discharge Nozzle for (2) Deep fryers Amerex P/N 14178 SUPPLY LINE LIMITATIONS: All andfttin s n from thedistIMU111011 the dischar efttin to the first tee. MAX CYLINDER •275 POINTS11 3/8 20 1 5 0 375 - 11 3/8 OR 11 25 1 5 1 475 - 14 1 112 1 25 1 1 1 5 2 600 - 18 112 25 1 5 2 Two-375 - 22 1/2 30 2 7 2 NOTE: 1. Use 3/8" supply line only when all piping is to be 3/8" pipe. 2. The supply line has a maximum venical rise above the distributor of 10 feet. SUPPLY BRANCH LINE (including last noule branch) LIMITATIONS: All pipe and fittings leaving the first splitting tee in the system and ending with the last nozzle in the last branch line. While the last nozzle branch is included in the piping limitations for the supply branch line, the limitation (pipe size and maximum length) for nozzle branch lines apply to this portion of the supply branch lineCYLIN ER MAX. FEET OF I MAX. QTY. FLOW PIPE STRAIGHT MAX. FEET OF OTY. OTY. REDUCING POINTS PIPE SIZE PIPE SPIL T TEES _ LBOWS BUSHINGS 275 - 6 3/8 20 25 7 8 0 375 - 11 3/8 OR 1 /2 30 10 8 2 475 - 14 318 30 12 8 2 ENS" 600 - 18 AS NOTED 35' /2" 50' 3/8" PIPE ONLY 14 8 2 Two-375-22 AS 45 of %" 18 8 0 NOTEED '30' of 3/8" NOTE: 1. In a single 3.75 Gallon Straight Pipe System, 5' of pipe may be transfened from the supply line to the supply branch line. ` 2. The use of 3/8" pipe with two manifold KP375s is only permitted when the SUPPLY LINE length is equal to or less than 20'. NOZZLE BRANCH LINE LIMITATIONS: All pipe and fittings leading from the supply branch tee to a system nozzle. CYLINDER TOTAL LINEAR MAX. QTY. MAX. QTY. MAX. QTY. FLOW 275 •8 3/8 32 5 10 0 375 -11 3/8 OR 1/2 32 8 12 11 475 - 14 3/8 32 10 15 0 600 - 18 3/8 32 11 18 15 Two-375 - 22 318 32 18 18 20 MAX. PER NOZZLE BRANCH 7 3 6 4 DUCT PROTECTION T 16" D41 AfAX. Ti i _� I 2"18"� Amerex (1) Duct Nozzle (P/N 16416) capable of protecting restaurant cooking ducts of unlimited length up to 50" perimeter or 016" ZONE OF PROTECTION LENCOmOFFOOD T x000 ovra - MAX. 0"MAX zory a'exoiacnorvi CENTERLINE NTERE OF ' _ • _ • • � -NOZZLES jIp6i zue josrrtoNjl...................................................... ...... ...... ...... ....' The Amerex provides two series of restaurant wet chemical fire suppression systems - KP & ZD systems. The current project uses ZD (Zone of Defense) system/design and its "Zone of Protection" is created by the use of overlapping spray from multiple nozzles creating an area that is soaked by wet chemical agent. This is accomplished by placing Amerex ZD nozzles, part number 14178, in a straight line from one end of the hood to the opposite end. The nozzles are to be a maximum of 20 inches apart on center and must start and end at a point no greater than 6 inches from the end of the hood. The nozzles are to be located 46 to 51 inches above the top surface of the appliances and aimed straight down. The resulting "Zone of Protection" is a rectangular area 34" deep x length of hood with its front and rear edges 17" from the centerline of the nozzles. PLENUM PROTECTION �'. 1'�^ ooww r0au..rE.ar 4 Amerex (1) Plenum Nozzle (P/N 11982) capable of protecting plenums up to 10 feet long AGENT CYLINDER MANUALPULL STATION MECHANICAL GAS VALVE FIRE EXTINGHISHERS !_ O 03 U U lQ^- VJ C 1n E U) U) C O U) 1n m Q CL U7 1.. LL U n Interior Front View U 1/;r= 1'-0" tent Upblast exhaust fan Entry door -- Ventilation hood MEL .:. MorM I® Baffle filters Grease trough Grease trap pan El (2) Amerex fire maw extinguishes LPG equipment Amerex manual pull station —I I IIIIIII—IIIIII—III IIIIIIIIIIIIIII—III—III III III1 n Interior Rear View 1 /2" = 1' 0" 7. Cross Sections I & II Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Sheet 9 of 16 Date: 4/21/2022 Revision Date: Project #: 0497 Quality Trailers Inc. Scale: 1/2"=1'-0" %W sales@qualityfoodtrailers.com / (971) 220-2626 71" N x D r. 3 58" rp q W C (D y x s 35 m IV (D _ fn II O = 18" s � Q O S CD r CD Cf)CID— ur Cn x _ m o" 3 _ I m 5Li -I I 3 e �I 0- N e I= -I cn C) o e e e — I� I I -I < CD - °o a Q 6 O , (10x (D 3 I I I I II 8 I I I I II I I r � I �I \ I- 9 o II �. _-I 3 o ICID - 3 II C :v =I I 8. Cross Section III Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Project #: 0497APIL IN Quality Trailers Inc. Sheet 10 of 16 Date: 4/21/2022 1 Revision Date: Scale: 1/2'=1'-0" Wsales@qualityfoodtrailers.com/(971)220-2626 Drain waiste vent through roof Pre -rinse Plumbing assembly equipment Stainless steel storage shelving Undercounter----— ——-- —— freezer-4, WHIM°' Water heater & yap & towel dispenser AC unit Potable water Wastewater tank pump inside tank inside I—III—IIIIIIIIIIII—IIIIIIIII—III—III—IIIIIIIIIIII—IIIIIIIII—III—III—III—IIIIII—IIIIIIIIII I I— n Interior Passenger Side View 1/2" = 1'-0" CR CD CD 0 Cn m \/ o \\\0 (' a En a \ m D ymm o m x y \ (D _ � 3 m cc m 0 \\\� � C n 3 0 \ m M a 90 \\\\ 1CD CD \\\\ 10. Perspective Cross Section I Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Project #: Q497 Quality Trailers Inc. Sheet 12 of 16 Date: 4/21/2022 1 Revision Date: Scale: sales@qualityfoodtrailers.com / (971) 220-2626 C CD V) CD CD 0 0 fn m o �\ _ � 6 \- \ ffl CD CL \� N R n w —\ C 7 \• R CD CD 11. Perspective Cross Section II Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Project #: Q497 Quality Trailers Inc. Sheet 13 of 16 Date: 4/21/2022 1 Revision Date: Scale: sales@qualityfoodtrailers.com / (971) 220-2626 Exterior Driver Side View 1/4" = V-0" Plexiglass concession window w/ sliding opening Vents through wall for refrigeration equipment O O H.C. self-service Vent through wall for shelf undercounter freezer O O Solid plexiglass window 1-1 I I 1 I I 1 I I 111 1 I I 1 I I-1 I -I I -I I I-1 I I 1 I I 1 I F n Exterior Passenger Side View 1 /4" = V-0" n Exterior Front View U 114" = 1'-0" :2) LP holder cages (4) Stabilizer scissors jacks Entry door 50A inlet w/ Potable weatherproof water inlet cover Direct potable 50A electric ® water inlet panle rated io for exterior o Potable water tank (n use overflow N — — — — O — — — O n Exterior Rear View CZ 1 /4" = V-0" N LU N T PPG color code: Green Elite #944638 n Front Driver Side Perspective View n Front Passenger Side Perspective View 13. Front Perspective Views Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Sheet 15 of 16 Date: 4/21/2022 1 Revision Date Note: The color displayed herein may not match the actual color of the trailer. Project #: 0497 Quality Trailers Inc. Scale: sales@qualityfoodtrailers.com / (971) 220-2626 PPG color code: PPG color code: Green Elite #944638 n Rear Passenger Side Perspective View U n Rear Driver Side Perspective View �J 14. Rear Perspective Views Note: The color displayed herein may not match the actual color of the trailer. Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Project #: 0497 Quality Trailers Inc. Sheet 16 of 16 Date: 4/21/2022 Revision Date: Scale: %W sales@qualityfoodtrailers.com / (971) 220-2626 APPENDIX A - Codes Specific Requirements Sheet # Sheet Name Item # Codes Specific Requirements / Notes 1 of 16 1 a. Floor Plan Legend - Equipment 1. WAC 296-15OV-1100 &1110. The flame spread ratings of the floor & ceiling coverings meet a flame & Finishes spread rating of 200 or less. Stainless steel meets the requirement of a flame spread rating of 50 or less which is what is required at walls adjacent to cooking ranges. 4 of 16 2. Electrical Floor Plan, Circuit 2.1. Electrical system tested per 2020 NEC 551.60 Diagram & Panel Schedule 2.2. 2020 NEC 551.56 C #8 cooper bonding conductor required to to chassis 2.2. NEC 210.8 (B) All single-phase receptacles rated 150 volts to ground or less, 50 amperes or less and three-phase receptacles rated 150 volts to ground or less, 100 amperes or less installed in the location specified in (1) through (10) sgall gave groundfault circuit -interrupter protection for personnel 2.4. 2020 NEC Table 310.15(B)(16) & 400.5[A](1) column B. & NEC 551.46. The size of the conductors of the main shore power cord to the panel is #6 AWG for 50 amp & is a listed molded type. 2.5. 2020 NEC Table 400.4. The power cord should be noted such as: TRADE NAME: Thermoplastic and extra hard usage, Hard service cord, listed for Damp & wet locations, with supply chord listed & molded and for use in wet locations. 2.6. 2020 NEC Table 250.102[C](1) &551.56 [B][C] The AWG of the grounding conductor for the panel is #6 AWG supplied with 50 AMP service cable. 2.7. The size of conductors listed on the panel schedule are per 2020 NEC. Table 310.15[B](16). All exposed non -current carrying metal parts that may become energized are effectively bonded per 2.8. NEC551.46. 2.9. The wire method and type used is MC Cable in a raceway as allowed per NEC 551.47 supported and secured by clamps desinged and installed so as not to dambage the cable as per NEC 330.30. 5 of 16 3. Plumbing Riser & Waste 3.1. WAC 51-56704.3 Commercial Sinks. Drainage Diagrams Except where specifically required to be connected indirectly to the drainage system, or when first approved by the authority having jurisdiction, all plumbing fixtures, drains, appurtenances, and appliances shall be directly connected to the drainage system of the building or premises. 3.2. UPC 20181004.0 Traps. 1004.1 Prohibited. No form of trap that depends for its seal upon the action of movable parts shall be used. No trap that has concealed interior partitions, except those of plastic, glass, or similar corrosion -resisting material, shall be used. "S" traps, bell traps, and crown -vented traps shall be prohibited. No fixture shall be double trapped. Drum and bottle traps shall be installed for special conditions. No trap shall be installed without a vent, except as otherwise provided in this code. 3.3. Fresh Water Supply System conforms to the requirements of WAC 296-15OV-1570 &1580, UPC Chapt. 6, NFPA 1192 Chapt. 7 & 7.3 and UPC Table 1701.1 reference standards. 6 of 16 4. Propane Floor Plan 4.1. NEC 551. 56 E #8 copper bonding conductor required to chassis from gas piping & not used for an electrical ground WAC 296-150V-1400. IFGC 408.4 Where a sediment trap is not incorporated as part of the appliance, a sediment trap shall be installed downstream of the appliance shutoff valve as close to the inlet of the appliance as 4.2. practical. The sediment trap shall be either a tee fitting having a capped nipple of any length installed vertically in the bottommost opening of the tee as illustrated in Figure 408.4 or other device approved as an effective sediment trap. Illuminating appliances, ranges, clothes dryers, decorative vented appliances for installation in vented fireplaces, gas fireplaces and outdoor grills need not be so equipped. 4.3. NFPA 11292.5.2.4.1 Containers shall be secured in place so they do not become dislodged when a load equal to eight times the container's filled weight is applied to the filled container's center of gravity in any direction. 4.4. LPG supply lines tested before and after appliance installation to comply with WAC 296-15OV-1450 and -1460. 4.5. WAC 296-15OV-1400 (1) All gas piping must be adequately supported by galvanized or equivalently protected metal straps or hangers at intervals of not more than 4 feet, except where adequate support and protection is provided by structural members. (2) Gas pipe supply connections must be rigidly anchored to a structural member within 6 inches of the supply connections. 4.6 Piping shall not be concealed per the requirements per WAC 296-150V-1400. 7 of 16 5. Fire Suppression System 5.1. NFPA 58 6.24.8.1 Mobile units including mobile kitchens and catering vehicles that contain hot Perspective View plates and other cooking equipment shall be provided with at least one approved portable fire extinguisher rated in accordance with NFPA 10, Standard for Portable Fire Extinguishers, at not less than 10-B:C. 5.2. Systems shall be operated and maintained per IFC Sec. 904.12.6 15. Appendix A - Codes Specific Requirements Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Project #: 0497 OL Quality Trailers Inc. Sheet 1 of 2 Date: 4/21/2022 Revision Date: Scale: sales@qualityfoodtrailers.com / (971) 220-2626 APPENDIX A (cont) - Codes Specific Requirements Sheet # Sheet Name Item # Code Specific Requirements / Notes 10 of 16 8. Cross Section III 8.1. The Exhaust Fan w/ Hinge Kits is installed as per NFPA 96 Fire Code, Chapter 8 - Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations in order to reduce the risk of fire by enabling access to the ventilation fan for cleaning out of grease and oil buildup as well as to prevent mechanical malfunctions of the Ventilation System. 8.2 IMC 506.5.3 - Exhaust fan mounting - Up -blast fans serving Type I hoods and installed in a vertical or horizontal position shall be hinged, supplied w/ a flexible weatherproof electrical cable to permit inspection and cleaning and shall be equipped w/ a means of restraint to limit the swing of the fan on its hinge. To be verified upon inspection. 8.3 WAC 296-1 50V-1 120 & IMC 507.4.1 The canopy style hood extends not less than 6" beyond the extent of the cooking appliances, not more than 48" above the cooking surface, and that the complete rear wall is non-combustible material with a flame spread rating of no greater than 25. 8.4. WAC 296-150V-1090 All appliances and equipment shall be installed per manufacturer's installation instructions and secured against displacement. 14 of 16 12. Elevation Views 12.1. Electrical safety label below electrical panel as per 2020 NEC 551.60 w/ the followin text: "WARNINGM This connection is for 120/240V AC, 3-pole, 4-wire grounding 60HZ,50A, do not exceed circuit rating. Exceeding the circuit rating may cause afire & result in death or serious injury" 12.2. Plumbing safety label on the potable water inlets box as per NFPA1192 w/ the following text: "WARNINGM Potable water only. Sanitize flush and drain water tank before using. See owner's manual for instructions, care, and maintenance information. failure to maintain tank can result in death or serious injury." 12.3. 7.3.10 Backflow Prevention Device. When nonpressurized water storage tank(s) (reservoirs) [except water heater(s)] for storing potable water are connected to the water distribution system of recreational vehicles that have a water service connection for an outside source of supply, they shall have an approved or listed backflow check valve or other approved or listed type backflow prevention device installed in the water supply piping adjacent to the water service connection. 15a. Appendix A (cont) - Codes Specific Requirements Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Sheet 2 of 2 I I Date: 4/21/2022 I Revision Date: Project #: 0497 Scab ML . Quality Trailers Inc. sales@qualityfoodtrailers.com / (971) 220-2626 Appendix B - Equipment Specification Sheets Index of Sheets Type Sheet # Item # Cover Page 1 of 46 - Appendix B - Index of Sheets B - Propane equipment 2,3 of 46 1 b. 2-Well steam table / Eagle Group HT2-LP 4,5 of 46 2b. Griddle / Imperial IMGA-3628-1 6 of 46 3b. Radiant broiler / Stratus SRB-18 7,8 of 46 4b. 4-Open burner / Imperial IHPA-4-24 9,10 of 46 5b. Deep fryer / Imperial IFS-40 C - Refrigeration equipment 11,12 of 46 1c. Refrigerator / Everest EBR1 13,14 of 46 2c. Undercounter freezer / Everest ETH 15,16 of 46 3c. Sandwich prep table / Everest EPR2 17,18 of 46 4c. Chef base / Everest ECB82D4 D - Electrical equipment 19,20 of 46 3d. Water heater / Rheem-Ruud EGSP10 21,22 of 46 4d. Water pump / SHURflo 2088-594-154 23-25 of 46 5d. 10' Ventilation hood / Captive Aire 3044 BD-2 & Exhaust fan / Captive Aire DU85HFA 26,27 of 46 6d. Makeup air fan / Captive Aire DMUAI8FA 28,29 of 46 7d. Air conditioner 15000 BTU E - Plumbing equipment 30 of 46 4e. 4e. Potable water tank / 80 Gal. / Custom Rotomolding W-426 31 of 46 5e. 5e. Wastewater tank / 135 Gal. / Custom Rotomolding GWT-135 F - Fire protection 32-43 of 46 1f. Amerex restaurant fire suppression system H - Additional features 44,45 of 46 3h. Transfer panel for a future generator Others* 46 of 46 - Safe loads for hardwood flooring *NOTE: The future generator is to be permanently installed and it is to be: Installed in a 26 MSG galvanized steel compartment vented properly per the manufacturer. NFPA 1192 - 6.4.5 & NEC 551.30. Installed in a vapor resistant enclosure sealed from the interior of the truck or trailer Connected directly to electrical system using hardware Secure against displacement per the manufacturer's installation instructions. 16. Appendix B - Equipment Specification Sheets Project Name: 20'x8.5' Double -Axle Food Trailer for La Casa De Amigos LLC Sheet 1 of 46 Date: 4/21/2022 1 Revision Date Project #: 0497 Scab OL . Quality Trailers Inc. sales@qualityfoodtrailers.com / (971) 220-2626