Loading...
REVIEWED BLD2022-1193+Manufacturer_Specifications_and_Installation_Instructions+9.8.2022_11.47.01_AM+3097130Job Name: System Reference: Date: Indoor Unit: MLZ-KP09NA INDOOR UNIT FEATURES • Fits between 16" joists spacing • Stylish, square design panel • Built-in condensate lift mechanism (19.6") • Serviceable from the bottom (electrical and flare connections) • Adjustable fan speeds and vane directions • Washable antibacterial and deodorizing filter • Multiple control options available: Hand-held Remote Controller (provided with unit) kumo cloud® smart device app for remote access Third -party interface options Wired or wireless controllers • Pocket inside the access panel for kumo cloud® Wireless Interface OUTDOOR UNIT FEATURES • Variable speed INVERTER -driven compressor • Innovative Joint Lap DC Motor leads to high efficiency and reliability • Pulse Amplitude Modulation technology • High-performance grooved piping for increased heat exchange efficiency Outdoor Unit: Wireless Remote Controller SUZ-KA09NA2 Illllil� °illlllllllilllllllllllll 'IIIIIIIIIIIIIIIIIIIiiIIIIIIIIIIP' ��IIIIIIIIIIIIIIIIIIIIII�' Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Maximum Capacity Rated Capacity Btu/h 9,000 Btu/h 9,000 Cooling 95°F1 Minimum Capacity Btu/h W 3,600 710 Maximum Power Input at Rated Power Input W 710 Moisture Removal Pints/h 1.5 Sensible Heat Factor 0.82 Power Factor (208/230V) % 96 Maximum Capacity Btu/h 9,500 Rated Capacity Btu/h 9,500 Cooling at 82°F Minimum Capacity Btu/h 4,100 Maximum Power Input W 600 Rated Power Input W 600 Maximum Capacity Btu/h 13,000 Rated Capacity Btu/h 12,000 Heating 47°FZ Minimum Capacity Btu/h 4,010 at Maximum Power Input W 1,000 Rated Power Input W 860 Power Factor % 98 Heating 17°F3 Maximum Capacity Rated Capacity Btu/h Btu/h 7,700 7,700 at Maximum Power Input W 700 Rated Power Input W 700 Heating 5°F4 Maximum Capacity Btu/h 6,100 at Maximum Power Input W 580 Heating at -4°F5 Maximum Capacity Btu/h 4,500 SEER EER1 19.5 12.6 HSPF (IV) 13.3 Efficiency COP at 47°F2 COP at 17°F in Maximum Capacity3 COP at 5°F in Maximum Capacity4 4.09 3.22 3.08 ENERGY STARO Certified (ENERGY STAR products are third -party certified by an EPA -recognized Certification Body.) Voltage, Phase, Frequency Guaranteed Voltage Range V AC Voltage: Indoor - Outdoor, S1-S2 V AC Yes 208/230V, 1 phase, 60Hz 187-253 208/230 Electrical Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote Controller V DC Wireless type Recommended Fuse/Breaker Size A 15 Recommended Wire Size (Indoor - Outdoor) AWG 14 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. MCA Fan Motor Full Load Amperage A 1 A 0.76 Fan Motor Output W 30 Airflow Rate at Cooling, Dry Airflow Rate at Cooling, Wet CFM CFM 311-283-254-212 264-240-216-180 Airflow Rate at Heating, Dry CFM 325-290-247-212 Sound Pressure Level (Cooling) dB(A) 38-34-31-27 Sound Pressure Level (Heating) dB(A) 37-34-29-26 Drain Pipe Size In. (mm) 1-1/4 (32) Indoor Unit Condensate Lift Mechanism, Maximum Distance In. (mm) 19-11/16 (500) Heat Exchanger Type Plate fin coil External Finish Color White Unit Dimensions W: In. (mm) 43-3/8 (1,102) D: In. (mm) 14-3/16 (360) H: In. (mm) 7-5/16 (185) Package Dimensions W: In. (mm) 46-5/16 (1,180) D: In. (mm) 15-3/4 (400) H: In. (mm) 11 (280) Unit Weight Lbs. (kg) 34 (15.5) Package Weight Lbs. (kg) 41 (18) Indoor Unit Operating Temperature Range Cooling Intake Air Temp (Maximum / Minimum)* °F 90F D.B / 73F W.B // 67F D.B / 57F W.B 80F D.B // 70F D.B 9 Heating Intake Air Temp (Maximum / Minimum) °F MCA A MOCP A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Airflow Rate CFM 1,229 / 1,172 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Blue Fin Coating on Heat Exchanger Yes Outdoor Unit Sound Pressure Level, Coolingi dB(A) 48 Sound Pressure Level, Heatingz dB(A) 50 Compressor Type DC INVERTER -driven Compressor Model KNB073FRVMC Compressor Rated Load Amps A 6.2 Compressor Locked Rotor Amps A 7.7 Compressor Oil Type // Charge oz. External Finish Color Base Pan Heater FV50S // 9.1 Ivory Munsell 3Y 7.8/1.1 Optional Unit Dimensions W: In. (mm) 31-1/2 (800) Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Package Dimensions D: In. (mm) 11-1/4 (285) H: In. (mm) 21-5/8 (550) W: In. (mm) 37 (940) D: In. (mm) H: In. (mm) Lbs. (kg) 14-15/16 (380) 24-13/16 (630) Unit Weight 81 (37) Package Weight Lbs. (kg) 88 (40) Cooling Air Temp (Maximum / Minimum)* °F 115114 Outdoor Unit Operating Cooling Thermal Lock -out / Re -start Temperatures** °F -1 / 3 Temperature Range Heating Air Temp (Maximum / Minimum) °F 75/4 Heating Thermal Lock -out / Re -start Temperatures** °F -9 / -4 Refrigerant Type R410A Charge Lbs, oz 2,5 Gas Pipe Size O.D. (Flared) In.(mm) 3/8 (9.52) Liquid Pipe Size O.D. (Flared) In.(mm) 1/4 (6.35) Piping Maximum Piping Length Ft. (m) 65 Maximum Height Difference Ft. (m) 40 Maximum Number of Bends 10 Notes AHRI Rated Conditions 1 Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB compressor speed) 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5*F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 70 DB, 60 WB // -4 DB, -5 WB 5Heating at -4°F (Indoor // Outdoor) °F *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Notes AHRI Rated Conditions 1 Cooling (Indoor H Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB compressor speed) 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5*F (Indoor // Outdoor) °F 70 DB, 60 WB H -4 DB, -5 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Grille (required) Anti -allergy Enzyme Filter Backlit, Wall -mounted, Wireless Controller Portable Central Controller ❑ MLP-444W ❑ MAC-408FT-E ❑ MHK1 ❑ MCCH1 Wired MA Controller) Simple MA Controller) ❑ PAR-33MAA ❑ PAC-YT53CRAU Touch MA Controller) ❑ PAR-CT01 MAU-SB Wired Remote Sensor ❑ M21-EAA-307 Wireless Temperature and Humidity Sensor ❑ PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 ❑ MOS1 System Control Interface2 ❑ MAC-3331F-E External Fan / Heater Control Relay Adapter ❑ CN24RELAY-KIT-CM3 ❑ PAC-USWHS002-WF-1 Wireless Interface Thermostat Interface ❑ PAC-US444CN-1 kumo station® ❑ PAC-WHS01 HC-E USNAP Interface ❑ PAC-WHS01 UP-E IT Extender ❑ PAC-WHS011E-E BACnet® and MODBUS® Interface ❑ PAC-UKPRC001-CN-1 External Fan / Heater Control Relay Adapter ❑ CN24RELAY-KIT-CM3 Lockdown Bracket for Hand-held Remote Controllers ❑ RCMKP1 CB MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor ❑ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 Btu/h [recommended] ❑ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] ❑ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 Btu/h ❑ X85-003 Fascia Kit for MicroBlue Pump — mounts the MicroBlue and sensor directly beneath the indoor unit ❑ T18-016 Drain Pan Level Sensor ❑ DPLS2 (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W 1 Requires MAC-3331F-E 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Optional Defrost Heater Hail Guard Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ MAC-881 SG ❑ MAC-640BH-U ❑ HG-B4 ❑ DSD-400P Condensing Unit Mounting Pad 16" x 36" x 3" Outdoor Unit Stand —12" High ❑ ULTRILITE1 ❑ QSMS1201 M Outdoor Unit Stand —18" High ❑ QSMS1801 M Outdoor Unit Stand —24" High ❑ QSMS2401M Heavy Duty Wall Mounting Bracket —Coated Steel ❑ QSWB2000M-1 Heavy Duty Wall Mounting Bracket —316 Series Stainless Steel ❑ QSWBSS 15' x 1/4" x 15' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-15 30' x 1/4" x 30' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-30 50' x 1/4" x 50' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-50 65' x 1/4" x 65' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-65 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. INDOOR UNIT OUTLINE DRAWING CENTER OF CELLING OPENING HOLE/SUSPENSION �O REMOTE CONTROLLER (TOP VIEW) BOLT PITCH/GRILLE IS THE SAME OUTLINE DRAWING 1/16 N 2-3/83/4 1/16F N Im L_ ____________________ JAIR OUTLET (UNDERSIDE) CONNECTION PART OF (RIGHT SIDE VIEW) ELECTRIC BOX ATTACHING DRAIN HOSE 9/165/8 41-3/8 SUSPENSION BOLT PITCH 14-3/16 PIIPPES CCOPNEECTION CONNECTION PART 09,12:03/8 OF ATTACHING '0 18:01/2 (FRONT VIEW) DRAIN HOSE 43-3/8 ATTACHING DRAIN HOSE DRAIN PIPE Ln - PIPE CONNECTION CONNECTION rn o ILUOUID PIPE) 37-13/16 3-1/16 (RIGID PVC PIPE 01/4 O.D.01 (26mm) .0 4-7/8 7-5/16 C' In 4-3/4 4-13/16 2-3/8 0 015/16 ) AIR OUTLET AREA 1-7/8 S;AIRI� AIRELECTRIC BOX �`//// INLET 0 2-5/16 DRAIN PAN THE B CEILLING SURFACE FIXING PIPE COVER IS IN 1 GRILLE OUTLINE DRAWING (MLP-444W) 38-1/16 MAX PROTRUSION DIMENSION OF FLAP CELLING AND OF GRILLE DISPLAY SURFACE RECEIVP 1-5/16 RECEPTION 47-1/4 15/16 1/2 WINDOW 6-13/16 CL 6-9/16 3-5/16 0 01-- _ CL m 6-9/16 ti 6-13116 HOLE POSITION \,mob O cc) FOR PANEL INSTALLATION (7 PLACES) �0 o INDOOR UNIT DETAIL VIEW (TOP VIEW) CENTER OF CELLING OPENING HOLE/SUSPENSION BOLT PITCH/ m GRILLE IS THE SAME RE Eq cc .:. Lr4 - L----- -'------------- - - - - - J `- - ------ ---------------- - aIR AIR OUTLET OUTLET (UNDERSIDE) 37-13/16 47-1/4 OUTLINE of GRILLE 3-15/16 3-15/16 2-1/8 41-3/8 SUSPENSION BOLT PITCH 2-1/8 13/16 45-11/16 CELLING OPENING HOLE 13/16 (FRONT VIEW) SUSPENSION BOLT W3/8 SUSPENSION BOLT W3/8 z £� Ln I CEILLING SURFACE CEILLING SURFACE GRILLE Unit: inch THE METHOD FOR STANDING DRAIN FROM INDOOR UNIT 0 CUT THE DRAIN HOSE (ACCESSORY) FOR USE, IF NECESSARY. DRAIN PIPE CONNECTION RIGID PVC PIPE OD.01 (26mm) \CEILLING SURFACE 09/12 kBtu/h 18 kBtu/h LIQUID PIPE 01/4 EXTENSION O.D. PIPE GAS PIPE 03/8 01/2 O.D. CONNECTION6 LIQUID PIPE FLARED CONNECTION 01/4 OF PIPE FLARED CONNECTION FLARED CONNECTION GAS PIPE 03/8 01/2 HEAT INSULATER OD. CONNECTION ID. EFFECTIVE LENGTH DRAIN HOSE 01-1/4 01 18-7/8 DRAIN PIPE CONNECTION RIGID PVC PIPE O.D. 01 (26mm) NOTE1. CUT THE DRAIN HOSE (ACCESSORY) FOR USE, IF NECESSARY. OPE Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. REQUIRED SPACE '1 4 in. (100 mm) or more when front and sides of the unit are clear 4 01-01' oz V \ore �� v Air in Drain hole 01-21/32 (KA09/12/15NA) rh n wL Drain hole 01-5/16 (KA09/12/15NAH) Air in � o 2 L m O N $i�'12o1e 01'C� � N � 0 C �n7 1-9/16 Air"out 2-holes 3/8x13/16 a v FORM# MLZ-KP09NA / SUZ-KA09NA2 - 201902 Unit: inch(mm) m a� U \1� o1e /n' (3S 0\�0 O��J '2 When any 2 sides of left, right and rear of the unit are clear Liquid refrigerant pipe joint Refrigerant pipe (flared) o 1/4 Gas refrigerant pipe joint Refrigerant pipe (flared) o 3/8 (KA09/12) o 1/2 (KA15) MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com %. Intertek Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.