Asbestos Survey
Project:
Commercial Structure
Pre -Demolition Survey
22730 Highway 99
Edmonds, WA 98026
Prepared For:
Jae Han
Boo Han Plaza IV LLC
3880 Steilacoom Blvd
Lakewood, WA 98499
Project Number: SR22-4079
TABLE OF CONTENTS
SECTION 1 1 Inspection Report
SECTION 2 1 Laboratory Results
SECTION 3 1 Photographs
SECTION 4 1 AHERA Certification
AHERA Certified Asbestos Survey / Inspection Report
5-19-2022
Prepared For: Boo Han Plaza IV I.I.C.
Jae Han
Project: Demolition Asbestos Survey
COMMERCIAL STRUCTURE — Shop and Garage
22730 Highway 99
Edmonds, WA 98026
A. Background
On 05-17-2022, Northwest Abatement Services, Inc. performed an asbestos identification inspection which will serve as our report
for all visible Asbestos Containing Building Materials located at the address listed above. The purpose of this inspection was to
ascertain the presence of asbestos containing materials located in the structure and provide a report to conform to WA( 296-62-
077, PSCAA Regulation III, Section 4 and 40 CFR 763 requirements for identification of asbestos. This survey also satisfies
regulatory criteria established by OSHA's Department of Labor and Washington State's Department of Labor and Industries for
identifying asbestos containing materials associated with the structure for future abatement and demolition. A copy of this report
may be submitted to the appropriate agencies as proof that a survey was performed prior to any renovation or demolition. A
coov of this report should also be aiven to the contractor and/or be maintained onsite durina anv abatement and demolition
activities. This survey was performed for the future demolition of commercial structure located at the address above.
B. Sampling Methodology
Suspect materials were sampled by an AHERA (Asbestos Hazard Emergency Response Act) accredited inspector. Sample locations
for this survey were chosen in a non-random fashion, with emphasis being placed on obtaining samples of each type of accessible,
suspect material, while minimizing damage to the material being sampled. Samples were collected by carefully removing small
portions of the suspect material in a non-abrasive manner. If possible, samples were collected from existing damaged areas.
Friable materials are materials which can be crushed, pulverized, or reduced to powder by hand pressure. These materials were
wetted with amended water prior to sampling to protect the inspector from potential exposure or accidental fiber release. PPE
(personal protective clothing) will only be utilized at the inspector's discretion. A particular suspect material may be located in
various separate places throughout the structure.
The EPA does not require that these materials be sampled in each location. Suspect materials of the same type, age, appearance
have the same date of installation, and are sampled in accordance with AHERA requirements, must provide statistically reliable
data which can be extrapolated on all remaining non sampled areas.
AHERA Protocol determines the number of samples of each material to be collected, depending on it's category and amount of
material present. The goal of AHERA is to ensure statistically reliable data and it accomplishes this by requiring or suggesting a
minimum number of samples to be collected, and in some cases, by using random sampling techniques to determine sampling
locations. However, in every case, AHERA relies on the judgment of the inspectors who are experienced in AHERA methodology
and the type of facilities being inspected. (See appendix A at end of the report)
After identifying the suspect materials, bulk samples were collected and taken to an asbestos laboratory to be analyzed for the
amount of asbestos and, the type of asbestos, if any. The asbestos samples were analyzed using Polarized Light Microscopy
(PLM), stain dispersion staining techniques in accordance with the EPA Method 600/R-93/166, which has a reliable limit of
quantification of one percent asbestos by volume.
Northwest Abatement Services, Inc. Inspection Report I 1
C. AHERA Certified Inspector Information
The Certified AHERA Inspector was Ethan Cortez
Certification #: BI/R-NES-0325-22-01, Expiration 03-25-2023
D. Survey Findings
There was a total of 9 suspect asbestos containing building materials (bulk samples), removed from the structure listed above, for
lab analysis. Based on the field inspection, homogenization of materials, and the results of the lab analysis, 0 of the 9 samples
tested Positive for Asbestos:
Sample Number Material Asbestos Content Quantity
Northwest Abatement Services, Inc. Inspection Report 1 2
E. Building Description
The commercial structure is located 22730 Highway 99, Edmonds, WA 98026.
The commercial structure is a metal and wood framed building with a flat sheet metal roof on a concrete slab.
Note: Allsuspect ACM finishes were sampled and tested according toAHMRAProtocol (See appendix A)
The suspect ACM (asbestos containing materials) sampled for analysis are as follows:
Sample Number
Material
Location
01
Silver sealant
Roof
02
Black Sealant
Roof
03
Asphalt Shingle
Roof
04
Trim Glue
Exterior
05
Ceramic Tile Grout
Right Bathroom
06
1" x 1" Ceramic Tile Grout
Left Bathroom
07
07A- Sheet Flooring 07B- Vinyl Floor
The
Shop
08
07A- Sheet Flooring 07B- Vinyl Floor
Tile
Shop
09
Lay -In Ceiling Tile
Shop
Northwest Abatement Services, Inc. Inspection Report 3
F. Conclusion
Laboratory results show all materials sampled were negative for asbestos. No asbestos abatement precautions
need to be taken prior to the demolition of the structure on site. If any additional materials not found in the
survey are discovered, additional sampling will need to occur to determine if asbestos is present. Prior to any
demolition or renovation, all friable and flan -friable asbestos containing materials (ACM) are to he removed and disposed of in
accordance with applicable Federal, State and Loral regulations. if there is any asbestos containing materials left on site, that will
flat be disturbed during the renovation or demolition process, an Asbestos Operational and Maintenance Program (OR) is to be
developed and implemeflted to monitor the remaining ACM.
/n the event any suspect materials are detected during the demolition of this structure, you will need to cease all demolition
activities and have these materials sampled for Asbestos.
The Puget Sound Clean Air Authority requires that all materials that contain I % or more Asbestos, that these materials be
removed by a licensed and Certified Asbestos removal contractor, prior to any demolition or renovation.
The abatement contractor should pro vide the Owner with copies of all required notifications to PSCAA and the Department of Labor
and Industries.
A certification letter will need to be obtained from the abatement contractor prior to applying for a demolition permit with PSCAA.
PSCAA will also want to see a copy of the asbestos survey.
Although extreme thoroughness and expertise were exercised to ensure the completeness of this survey, existing conditions may
have prevented the discovery of other suspect asbestos containing material. NW Abatement Services, Inc. is not responsible for
materials that may be hidden from sight and cannot be discovered with reasonable diligence. Any suspect material not covered in
this survey that is encountered during the renovation or demolition procedure should be verified by analysis prior to disturbance.
It should be noted that this survey was conducted only to ascertain the presence of asbestos containing materials.
There was no survey conducted by NW Abatement Services, Inc. to determine the presence of PCB material (ballast, etc.), UST's,
radon gas or any other hazardous material that may be present onsite.
This report has been prepared for the sole use of our client and its representatives for this project only. The analyses, conclusions
and recommendations presented in this report are based upon conditions encountered at the time of our survey only. The scope
of services performed during this survey may not be appropriate for the needs of others. Re -use of this document or the findings,
conclusions or recommendations presented herein, are at the sole risk of said user. NW Abatement Services, Inc. cannot be held
responsible for the interpretation by others of the data contained in this report.
The conclusions presented in this report were based on the results of sample analysis presented by a subcontracted, third party,
analytical laboratory. Northwest Abatement Services, Inc. is not responsible for variations in analytical results or inaccuracies
resulting from laboratory analysis.
This survey is not intended for use as abatement plans and/or specifications. Northwest Abatement Services, Inc. recommends
that professional plans and specifications be prepared for all larger scale projects.
No warranty, expressed or implied, is made.
Northwest Abatement Services, Inc. Inspection Report 1 4
Appendix A
The following AHERA protocol was used in determining the number of suspect samples to collect:
Surfacing materials:
1) Homogeneous area equal to or less than 1000 SF (minimum 3 samples).
2) Homogeneous area greater than 1000 SF but less than 5000 SF. (5 samples)
3) Homogeneous area greater than 5000 SF. (7 samples)
Thermal Systems Insulation (TSI):
1) Homogeneous area (1 per each type of suspect materials).
Miscellaneous materials:
1) Homogeneous area (1 per each type of suspect materials)
Suspect Materials are divided into 3 categories:
1) Surfacing materials — ACM sprayed or troweled on surfaces (walls, ceilings, and structural members) for acoustical,
decorative, thermal insulation or fireproofing purposes. Examples include plaster, popcorn textured ceilings, skim coat
textures, and structural fireproofing.
2) Thermal System Insulation — Insulation used to inhibit heat transfer or prevent condensation on pipes, boilers, tanks,
ducts, and various other components of hot and cold -water systems, and heating, ventilation, and air conditioning (HVAO
systems. Examples include pipe lagging, pipe wrap; block, butt, and blanket insulation; cement and "muds" and a variety of
other products such as gaskets and ropes.
3) Miscellaneous Materials — Materials not classified under surfacing materials or thermal systems insulation. Examples
include: floor tile, ceiling tile, roofing felts, concrete piping, outdoor siding and fabrics, glazing putty, wall board and
associated assembly component, various mastics, etc. such as floor tile mastics, wall board mastics, ceiling tile mastics etc.
If you have any questions regarding this asbestos survey/inspection report, please contact us at (253) 588-0440, or FAX: (253)
588-0198.
Respectfully submitted,
gtaK &�&4
Ethan Cortez
Certified AHERA Inspector
NORTHWEST ABATEMENT SERVICES, INC.
Northwest Abatement Services, Inc. Inspection Report 1 5
sanATi*r*
Technologies Laboratory
The IdeMif
Analysis Report
prepared for
Northwest Abatement Services, Inc.
Report Date: 5/19/2022
Project Name: Boo Han Plaza IV Demo Survey
Project #: SR22-4079
SanAir ID#: 22024361
TESTING
r"'2T
NVLAP LAB CODE 200870-0
Page 1 of 6
SanAir
Technologies Laboratory
Name: Northwest Abatement Services, Inc.
Address: P.O. Box 39220
Lakewood, WA 98496
Phone: 253-588-0440
Dear Ethan Cortez,
SanAir ID Number
22024361
FINAL REPORT
5/19/2022 2:29:26 PM
Project Number: SR22-4079
P.O. Number: SR22-4079
Project Name: Boo Han Plaza IV Demo Survey
Collected Date: 5/17/2022
Received Date: 5/18/2022 10:45:00 AM
We at SanAir would like to thank you for the work you recently submitted. The 11 sample(s) were received on
Wednesday, May 18, 2022 via UPS. The final report(s) is enclosed for the following sample(s): 01, 02, 03, 04, 05, 06,
07A, 07B, 08A, 08B, 09.
These results only pertain to this job and should not be used in the interpretation of any other job. This report is only
complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely,
Sandra Sobrino
Asbestos & Materials Laboratory Manager
SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information
Sample conditions:
- 11 samples in Good condition.
10501 Trade Ct., N. Chesterfield, VA 23236 1804.897.1177 1 Fax: 804.897.0070 1 www.SanAir.com I IAQ@SanAir.com Page 2 of 6
SanAir ID Number
22024361
A�:..
i r
FINAL REPORT
Technologies Laboratory
5/19/2022 2:29:26 PM
Name: Northwest Abatement Services, Inc.
Project Number: SR22-4079
Address: P.O. Box 39220
P.O. Number: SR22-4079
Lakewood, WA 98496
Project Name: Boo Han Plaza IV Demo Survey
Phone: 253-588-0440
Collected Date: 5/17/2022
Received Date: 5/18/2022 10:45:00 AM
Analyst: Pisula, Nicholas
Asbestos Bulk PLM EPA 600/R-93/116
.-
01 / 22024361-001
Silver
100% Other
None Detected
Sealant/ Roof
Non -Fibrous
Homogeneous
02 / 22024361-002
Silver
100% Other
None Detected
Sealant/ Roof
Non -Fibrous
Homogeneous
03 / 22024361-003
Black
100% Other
None Detected
Asphalt Shingle/ Roof
Non -Fibrous
Homogeneous
04 / 22024361-004
Tan
100% Other
None Detected
Trim Glue/ Exterior
Non -Fibrous
Homogeneous
05 / 22024361-005
White
100% Other
None Detected
Ceramic Tile Grout/ Right
Non -Fibrous
Bathroom
Homogeneous
06 / 22024361-006
Grey
100% Other
None Detected
1" X 1" Ceramic Tile Grout/ Left
Non -Fibrous
Bathroom
Homogeneous
07A / 22024361-007
Brown
100% Other
None Detected
Sheet Flooring
Non -Fibrous
Homogeneous
07B / 22024361-008 Grey 100% Other None Detected
Vinyl Floor Tile, Floor Tile Non -Fibrous
Homogeneous
07B / 22024361-008 Tan 100% Other None Detected
Vinyl Floor Tile, Mastic Non -Fibrous
Homogeneous
08A / 22024361-009 Brown 100% Other None Detected
Sheet Flooring Non -Fibrous
Homogeneous
Analyst: 6_4 Approved Signatory: �/-later
Analysis Date: 5/19/2022 Date: 5/19/2022
Page 3 of 6
A i r
Technologies Laboratory
Name: Northwest Abatement Services, Inc.
Address: P.O. Box 39220
Lakewood, WA 98496
Phone: 253-588-0440
Analyst: Pisula, Nicholas
SanAir ID Number
22024361
FINAL REPORT
5/19/2022 2:29:26 PM
Project Number: SR22-4079
P.O. Number: SR22-4079
Project Name: Boo Han Plaza IV Demo Survey
Collected Date: 5/17/2022
Received Date: 5/18/2022 10:45:00 AM
Asbestos Bulk PLM EPA 600/R-93/116
08B / 22024361-010
Grey 100% Other None Detected
Vinyl Floor Tile, Floor Tile
Non -Fibrous
Homogeneous
08B / 22024361-010
Tan 100% Other None Detected
Vinyl Floor Tile, Mastic
Non -Fibrous
Homogeneous
08B / 22024361-010
White 100% Other None Detected
Vinyl Floor Tile, Leveling
Non -Fibrous
Compound
Homogeneous
09 / 22024361-011 White
Lay -In Ceiling Tile/ Shop Fibrous
Homogeneous
Analyst: 'lam. &-
Analysis Date: 5/19/2022
60% Cellulose 10% Other None Detected
30% Min. Wool
Approved Signatory: A-k-- 4444
Date: 5/19/2022
10501 Trade Ct., N. Chesterfield, VA 23236 1804.897.1177 1 Fax: 804.897.0070 1 www.SanAir.com I IAQ@SanAir.com Page 4 of 6
Disclaimer
This report is the sole property of the client named on the SanAir Technologies Laboratory chain -
of -custody (COC). Results in the report are confidential information intended only for the use by
the customer listed on the COC. Neither results nor reports will be discussed with or released to
any third party without our client's written permission. The final report shall not be reproduced
except in full without written approval of the laboratory to assure that parts of the report are not
taken out of context. The information provided in this report applies only to the samples
submitted and is relevant only for the date, time, and location of sampling. The accuracy of the
results is dependent upon the client's sampling procedure and information provided to the
laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will
provide evaluation reports based solely on the sample(s) in the condition in which they arrived at
the laboratory and information provided by the client on the COC, such as: project number,
project name, collection dates, po number, special instructions, samples collected by, sample
numbers, sample identifications, sample type, selected analysis type, flow rate, total volume or
area, and start stop times that may affect the validity of the results in this report. Samples were
received in good condition unless otherwise noted on the report. SanAir assumes no
responsibility or liability for the manner in which the results are used or interpreted. This report
does not constitute and shall not be used to claim product certification, approval, or endorsement
by NVLAP, NIST, or any other U.S. governmental agencies and may not be certified by every
local, state, and federal regulatory agencies.
Samples are held for a period of 60 days. Fibers smaller than 5 microns cannot be seen with this
method due to scope limitations.
For NY state samples, method EPA 600/M4-82-020 is performed.
NYELAP Disclaimer:
Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and
similar non -friable organically bound materials. Quantitative transmission electron microscopy is
currently the only method that can be used to determine if this material can be considered or
treated as non -asbestos containing.
Asbestos Certifications
NVLAP lab code 200870-0
City of Philadelphia: ALL-460
PA Department of Environmental Protection Number: 68-05397
California License Number: 2915
Colorado License Number: AL-23143
Connecticut License Number: PH-0105
Massachusetts License Number: AA000222
Maine License Number: LB-0075, LA-0084
New York ELAP lab ID: 11983
Rhode Island License Number: PCM00126, PLM00126, TEM00126
Texas Department of State Health Services License Number: 300440
Commonwealth of Virginia 3333000323
Washington State License Number: C989
West Virginia License Number: LT000616
Vermont License: AL166318
Louisiana Department of Environmental Quality: 212253, Cert 05088
Revision Date: 8/14/2020
Page 5 of 6
,..-•�� 10501 Trade Ct., Suite 100
SanAir ID Number
N. Chesterfield, VA 23236 Asbestos
San804.897.1177 / 888.895.1177 Chain of Custody
ir Fax 804.897.0070 Form 140, Rev 6,1126/2022
Technologies Laboratory sanair.com
Northwest Abatement Services, Inc.
SR22-4079
Cortez
Company:
Project4:
ollected bv:Ethan
Address- P.O. Box 39220
Project Frame: Boo Han Plaza IV Demo Survey
Phone 4: 253-588-0440
City, St., Zip. Lakewood, WA 98496
Date Collected: 05/17/2022 _
Fax 4. 253-583-0277
State of Collection WA Accountfl' 1587
P.O. Number: SR22-4079
Email: ethan@nwabatement.Com
Milk Air Soil
ABB
PLM EPA 6001R-931116
❑✓
ABA
PCM NIOSH 7400
E I
[71B_!E777]
PLM EPA 600IR-93/116 (Qua].}
Positive Stop
ABA-2
OSHA w/ TWA-
01Soil
ABSP PLM CARB 435 (LOD <1%}
ABEPA
PLM EPA 400 Point Count
El
ABTEM
TEM AHERA
F--J
ABB IK
PLM EPA 1000 Point Count
ABATN
TEM NIOSH 7402
El
ABSPI
ABSP2
PLM CARB 435 (LOD 0.25%)
PLM GARB 435 (LOD 0.1%)
ABBEN
PLM EPA NOES**
E
AB12
TEM Level lI
ABBCH
TEM Chatfield**
Other:
Dust
ABBTM
TEM EPA NOB**
New York ELAP
ABWA
TEM Wipe ASTM D-6480
ABQ
PLM Qualitative
ABEPA2 I
NY FLAP 198.1
F-1
ABDMV
TEM Microvae ASTM D-5755
** Available on 24-hr. to 5-day TAT ABENY NY ELAP 198.6 PLM NOB
ABBNY NY FLAP 198.4 TEM NOB
Water Matrix Other
All] IE EPA 1002 0
Turn Around
3 MR (4 HR TEM) ❑
6 HR (8HR TEM) ❑
12 RR ❑
1 Day I]
❑ 2 pays
❑ 3 Days
❑ 4 Days
❑ 5 bays
Times
Special Instructions
Sample #
Sample Identiflieation/Location
Volume
or Area
Sample
Date
Flow
Rate,
Start— Stop
Time*
01
Silver Sealant/ Roof
Throughout
ABB
02
Black Sealant/ Roof
Throughout
ABB
03
Asphalt Shingle/ Roof
Throughout
ABB
04
Trim Glue/ Exterior
Throughout
ABB
05
Ceramic Tile Grout/ Right Bathroom
Throughout
ABB
06
1" x T' Ceramic Tile Grout/ Left Bathroom
Throughout
ABB
07
07A - Sheet Flooring 07B- Vinyl Floor Tile
Throughout
ABB
08
08A - Sheet Flooring 08B- Vinyl Floor Tile
Throughout
ABB
09
Lay -In Ceiling Tile/ Shop
Throughout
ABB
Relinquished by
Date
Time
Received by
Date
Time
Ethan Cortez
5/17/2022
11:45AM
152f.La
,M
it no technician is provided, then the primary contact for your account will be selected. Unless scheduled, the turnaround time for all samples recervea aver a pm zb r
will be logged in the next business day. Weekend or holiday work must be scheduled ahead of time and is charged at 150% of the 3hr TAT or a minimum charge or
$150. A courier charge will be applied for same day and one -day turnaround times for offshe work. SanAir covers Ground and Next Day Air shipping. Shipments
billed to SanAir with a faster shipping rate will result in additional charges. 1 1
Page °� age 6 of 6
y w
ems-
SURVEY PHOTOS
22730 Highway 99, Edmonds, WA 98026
AHERA
BUILDING INSPECTOR
REFRESHER CERTIFICATE
This is to certify that
E-fhall c6ril ez,
has attended and satisfactorily completed all requirements to maintain accreditation as
an AHERA Building Inspector in accordance with the Toxic Substance Control
Act Title (Section 206) and 40 CFR 763.
Accreditation No. BIIR-NES-0325-22-01
Course Date: Mar. 25, 2022
Valid through: Mar. 25, 2023
c
NOW Environmental Services, Inc.
34004 — 9t" Avenue South, Suite # 12
Federal Way, Washington 98003
(253) 927-5233