FIR2021-0022+Drawings+3.5.2021_9.30.29_AM+2077706I-VSIONS DESCRIPTION DATE: FOR QUESTIONS, CALL THE Seattle [If fice Reed Brown PHONE: (425) 212-5996 EMAIL: reg85@captiveaire.com 1" LAYER OF INSULATI❑N FACTORY INSTALLED IN 1.00' END STANDOFF MEETS 0" REQUIREMENTS CLEARANCE TO C❑MBUSTIBLE SURFACES. INSTALLER MUST C❑NFIRM HOOD IS INSTALLED SUCH THAT THE SPECIFIED WALL, ACTING AS AN END PANEL, IS MATED TIGHT TO THE CORRECT END OF HOOD TO ACHIEVE A REDUCED MINIMUM EXHAUST CFM LISTING, N❑N-C❑MPLIANCE WILL NULLIFY THE ETL LISTING, V❑ID THE MANUFACTURER'S WARRANTY, AND HOLD THE CONTRACTOR LIABLE FOR ANY AND ALL LOSSES, COSTS, AND EXPENSES RELATED TO THE NON-CONFORMANCE OF THE MANUFACTURER'S SPECIFIED INSTRUCTI❑N, THE WALL ACTING AS AN END PANEL MUST EXTEND NO LESS THAN 20' FROM THE INTERSECTING WALL ON WHICH HOOD IS MOUNTED AND MUST EXTEND NO LESS THAN 20' UNDER BOTTOM OF HOOD TO BE ELIGIBLE FOR REDUCED MINIMUM EXHAUST CFM LISTING, PATENT NUMBERS AC-PSP (UNITED STATES) - US PATENT 7963830 B2. AC-PSP WALL (CANADA) - CA PATENT 2820509. AC-PSP ISLAND (CANADA) - CA PATENT 2520330, 1' LAYER OF INSULATI❑N FACTORY INSTALLED IN INTERNAL BACK STANDOFF, MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO C❑MBUSTIBLE SURFACES, 1" LAYER OF INSULATI❑N FACTORY INSTALLED IN INTERNAL BACK STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO C❑MBUSTIBLE SURFACES. 1.5" I.P,S, DRAIN DROP ENGINEER IS RESP❑NSIBLE FOR DRAIN LINE DESIGN BEYOND THE HOOD. DRAIN LINE MUST BE INSTALLED PER LOCAL CODES, DRAIN LINE MUST BE SLOPED (MINIMUM % INCH PER FOOT), AV❑ID ANY UNNECESSARY 90 DEGREE TURNS, IF C❑MBINED WITH OTHER DRAIN LINES, THEN PIPE SIZE SHOULD BE INCREASED ACC❑RDINGLY, P-TRAPS SHOULD NOT BE USED IN THE GREASE DRAIN LINE AND HEAT TAPE MUST BE USED WHERE DRAIN LINE IS RUN IN ENVIR❑NMENTS THAT WOULD S❑LIDIFY GREASE. / SIZE BUILDING GREASE INTERCEPT❑R ACC❑RDINGLY. BOTH ENDS 3 3" 15" I 12' I 15" 15" 12" 1 12 " 15" 418° 016" 016„ 4„ 0- O O I U.L. LISTED ROUND RECESSED ALLANS❑N LED FIXTURE AND LED LIGHT. 60" 78' U.L. LISTED RECESSED ALLANS❑N ROUND LED FIXTURE AND LED LIGHT, ❑ ❑ 3/4' .1 C❑NNEC UTILITY BY FAC BOTH E p 20' 20" 20' 0 20' 20" 20" CABINET. rol .o. ..... 20' 20' 20' 12"-------------T 9" 12"------- ------T 9" 12"------- ------T 9" 12"------- 1 ------T 12" - 9" -----------T 9" 12"- - - - - - - ------T 9" 18" T 20" - -----------T2"- - - - - - - ------T2"------- ------� 48' 96„ 48„ 10 � 10 1L ®0 10" ®0 17 1/4' 34' -� 33 3/4" - 34" -� 33 3/4' - 34' 16' 0'N❑M./16' 0.00"❑D. 12 43 1/2" 43 1/2" 17'-0.00" OVERALL LENGTH, 15 1/4" �� 28 3/4" 28 3/4" PLAN VIEW — HOOD #2 Main — Right) 7' 3'N❑M./7' 3.00"❑D. 16' 0.00" LONG 603OND-2—PSP—F NOTE: ADDITI❑NAL HANGING ANGLES PR❑VIDED FOR HOODS 12' AND LONGER, 7'-4.00" OVERALL LENGTH, PLAN VIEW — HOOD #Main — Left) 7' 3.00" LONG 7830ND-2—PSP—F .S. (N.P.T.) HOT WATER FI❑N STUBS ARE PREFIT F❑RY. 0S Approved by Fire 03/17/2021 AFM fC_Fttterer Hood needs to be interconnected into fire alarm system Hood needs gas and electrical shunts. Drawing of approved system and appliances to be laminated and attached in control box Complete above for fire final, enter into Tegris fire reporting system 9MMIYAIQIi 0 0 0 0 0 W, 0 u s Q V) s d O CLI E O 0 C d LLJ DUE: 2/23/2021 ONGX: 4647383 UMN RTB - 85 BE SOLE: 3/4" = 1 '-0" MPSTERMWING RECEIVED Mar 05 2021 SHEET NO. IEVSIONS DESCRIPTION DATE: FIRE SYSTEM NO TAG TYPE SIZE FLOW POINTS INSTALLATI❑N SYSTEM L❑CATI❑N ON HOOD 1 CORE PR❑TECTI❑N 0 0 FIRE CABINET RIGHT RIGHT, HOOD 2 FTPF. .S Y,`'TFAJ PA PT.S' T,T.S T R Y FIRE QTY BY QTY BY SYSTEM TAG KEY NUMBER - PART DESCRIPTI❑N FACTORY DIST NO 34 - 34 - A0019852 24VDC OR 120VAC SINGLE ACTI❑N MANUAL ACTUATI❑N DEVICE (PUSH/PULL STATI❑N) WITH PR❑TECTIVE COVER, ONE (1) NORMALLY OPEN CONTACT. 1 0 26 - 26 - QSA-3/8 QUIK SEAL - 3/8" (UL), 9 0 16 - 16 - 3070-3/8H-10-SS NOZZLE - CORE PR❑TECTI❑N APPLIANCE COVERAGE NOZZLE (INCLUDES METAL BLOW OFF CAP, LANYARD, AND CHROME -PLATED PIPE). 11 0 0 - 0 - SLPC❑N-30FT SUPERVISED LOOP C❑NNECTI❑N KIT, C❑NTAINS THE PARTS NEEDED TO CONNECT THE SUPERVISED LOOP BETWEEN HOODS WITH UPT❑ 29' GAP. KIT C❑NTAINS 32 FEET 1 0 ❑F BLACK MG WIRE, 32 FEET OF TAN MG WIRE, 30 FEET OF FLEXIBLE C❑NDUIT, AND TWO 7/8" CONNECTORS. 0 - 0 - SLPC❑N-03FT SUPERVISED LOOP C❑NNECTI❑N KIT, C❑NTAINS THE PARTS NEEDED To CONNECT THE SUPERVISED LOOP BETWEEN END TO END HOODS WITH LESS THAN A 2' GAP. KIT 1 0 C❑NTAINS 5 FEET OF BLACK MG WIRE, 5 FEET OF TAN MG WIRE, 3 FEET OF FLEXIBLE C❑NDUIT, 1 AND TWO 7/8" CONNECTORS. 0 - 0 - CBI-107 CHROME PLATED PIPE FITTING 3/8" NPT UNI❑N. 2 0 0 - 0 - CBI-106 CHROME PLATED PIPE FITTING 3/8" NPT 90 DEGREE ELBOW, 2 0 0 - 0 - CBI-104 CHROME PLATED PIPE FITTING 3/8" NPT TEE. 2 0 0 - 0 - CBI-102 CHROME PLATED PIPE FITTING 3/8" NPT 45 DEGREE ELBOW. 2 0 0 - 0 - A0029078 JUNCTI❑N BOX FOR CORE PR❑TECTI❑N MANUAL PULL STATI❑N, 1.5" DEEP BACK BOX, BLUE. 1 0 0 - 0 - 59361-1/2 2X4 EXTENSI❑N RING. 4 0 0 - 0 - 12-H28021-005-OT-600 DUCT FIRE THERMOSTAT, NO, CLOSE ON TEMP RISE AT 600°F. 2 0 0 - 0 - 12-F28021-005360 DUCT FIRE THERMOSTAT. NO, CLOSE ON TEMP RISE AT 360°F. 2 0 0- 0- 100-BW 2X4 BLANK PLATE FOR J-BOX. 4 1 0 JOB #: 4647383. JOB NAME: CHARCOAL ART STUDI❑ RESTAURANT - 2020 R1 HOODS, SYSTEM SIZE: CORE TOTAL FP HOOD # 1 7' 3,00" LONG x 78" RISER # 1 SIZE: 0" x 0 HOOD # 2 16' 0,00" LONG x 60" RISER # 1 SIZE: 0" x 0 RISER # 2 SIZE: 0" x 0". REQUIRED: 0, WIDE x 30" HIGH, WIDE x 30" HIGH, 24V CMF BASIC OFEP=-I\G IfISTF'I.1S:TIONS CORE PROTECTION FIRE SYSTEM CORE PROTECTION FIRE SYSTEMS CAN BE INSTALLED FOR HOOD FIRE PROTECTION, AS WELL AS POLLUTION CONTROL UNIT FIRE PROTECTION. IN THE EVENT OF A FIRE, OR ON MANUAL ACTUATION CORE PROTECTION IS ACTIVATED, IF THE INSTALLED FIRESTAT IN THE AIRSTREAM SENSES A TEMPERATURE HOTTER THEN ITS INTERNAL SET POINT OR IF THE MANUAL ACTUATION DEVICE IS PUSHED THE FIRE SYSTEM IS ACTIVATED, IN KITCHEN HOODS AN ELECTRIC WATER SOLENOID IS ENERGIZED ALLOWING THE FLOW OF WATER TO THE HOOD DUCT AND PLENUM THROUGH THE SELF CLEANING HOOD SPRAY BAR. AT THE SAME TIME A SECOND WATER SOLENOID IS ENERGIZED AND ALLOWS THE FLOW OF WATER TO THE APPLIANCES, SURFACTANT IS CONTINUALLY INJECTED INTO THE WATER STREAM TO HELP SUPPRESS THE FIRE, IN A POLLUTION CONTROL UNIT, THIS ELECTRONIC SIGNAL ENERGIZES A SOLENOID ALLOWING THE FLOW OF WATER INTO THE INDIVIDUALLY PIPED MODULES, ONCE THE FIRE SYSTEM IS ACTIVATED, A `SIRE SYSTEM ACTIVATED" EIGHT IS ILLUMINATED ON THE CORE CONTROL PANEL AND AN AUDIBLE ALARM SOUNDS. FOR KITCHEN HOOD PROTECTION ALL GAS AND ELECTRIC APPLIANCES UNDER THE HOOD MUST BE ELECTRICALLY INTERLOCKED TO SHUT OFF, THIS IS ACHIEVED VIA A GAS VALVE RELAY AND/OR A SHUNT TRIP BREAKER. A TIMER IS ALSO ENERGIZED UPON FIRE SYSTEM ACTIVATION, THE TIMER IS SET FOR 30 MINUTES AND KEEPS THE WATER SPRAY SYSTEM RUNNING FOR A MINIMUM OF 30 MINUTES, THIS IS NECESSARY TO HELP EXTINGUISH ALL REMAINING DUCT FIRE POTENTIAL. THE FIRE SYSTEM IS ELECTRICALLY OPERATED AND THUS REQUIRES A BATTERY BACKUP SYSTEM. IN THE EVENT OF A LOSS OF ELECTRICAL POWER, ALL GAS AND ELECTRIC APPLIANCES UNDER THE HOOD MUST BE ELECTRICALLY INTERLOCKED TO SHUT OFF, THIS IS ACHIEVED VIA A GAS VALVE RELAY AND/OR A SHUNT TRIP BREAKER, THE BATTERY BACKUP WILL AUTOMATICALLY ENERGIZE UPON A LOSS OF POWER, THE BATTERY BACKUP WILL MONITOR THE FIRE SYSTEM CIRCUIT FOR ONE DAY AND BE ABLE TO OPERATE THE FIRE SYSTEM CIRCUIT FOR A MINIMUM OF 30 MINUTES, ONCE POWER IS RESTORED, THE BATTERY WILL AUTOMATICALLY RECHARGE, THERE ARE MULTIPLE ACTIONS REQUIRED TO RESET THE FIRE SYSTEM, FIRST, THE FIRESTAT MUST BE COOLED TO BELOW ITS INTERNAL SET POINT AND THE MANUAL ACTUATION DEVICE MUST BE RESET BY TWISTING THE BUTTON IN A CLOCKWISE DIRECTION, ONCE BOTH OF THESE DEVICES HAVE BEEN RESET, THE TIMER WILL AUTOMATICALLY STOP THE FIRE SYSTEM ONCE ITS TIME DURATION HAS ENDED. AN ALTERNATIVE METHOD TO BYPASSING THE TIMER IS TO PRESS THE FIRE SYSTEM RESET BUTTON ON THE FACE OF THE CORE CONTROL CABINET. THIS WILL DE - ENERGIZE THE TIMER AND RESET THE SYSTEM, NOTE: THE FIRESTAT MUST BE COOL AND THE MANUAL ACTUATION DEVICE MUST BE RESET FOR THIS BUTTON TO WORK, THE FIRE SYSTEM MUST BE FILLED WITH SURFACTANT AND NOZZLE CAPS MUST BE REINSTALLED. AFTER A FIRE, FULL INSPECTION BY A CERTIFIED PROFESSIONAL MUST BE CONDUCTED PRIOR TO RESTARTING THE FIRE SYSTEM. 0 0 0 MUM CORE APPLICATION SPECIFIC DETAILS C o cv SELF CLEANING HOODS � o SELF CLEANING HOOD OPTION IS REQUIRED TO APPLY CORE PROTECTION, 00 HIGH EFFICIENCY, HIGH VELOCITY CARTRIDGE, SOLO, OR COMBO FILTERS ARE 0T) REQUIRED. IF SUBSTITUTE FILTERS ARE UTILIZED, PRODUCT WARRANTY IS VOID CLJ AND THERE IS NO GUARANTEE IN PERFORMANCE. r-k-1 SOLID FUEL APPLIANCES o Q SOLID FUEL APPLIANCES PRODUCE SPARKS THAT CAN TRAVEL INTO DUCTWORK THESE APPLIANCES REQUIRE SOLO FILTERS AND AN ADDITIONAL FIRESTAT AT THE s DUCT DISCHARGE NEAR THE FAN IF THE DUCTWORK EXCEEDS 10 FEET IN LENGTH -� OR CONTAINS HORIZONTAL DUCT RUNS, INDICATE ON DUCTWORK DRAWING C WHERE FIRESTAT IS TO BE INSTALLED WITH QUICK SEAL, ALL ADDITIONAL O FIRESTATS ARE WIRED INTO THE SUPERVISED LOOP WITH THE FIRST FIRESTAT, DUCT C�j SHOULD BE INSULATED PER CODE REQUIREMENTS. IF SUBSTITUTE FILTERS ARE o UTILIZED, PRODUCT WARRANTY IS VOID AND THERE IS NO GUARANTEE IN cd W PERFORMANCE. SELF CLEANING HOODS AND ETL LISTED DUCTWORK ARE ALSO REQUIRED. DUCT FIRESTATS A FIRESTAT MUST BE INSTALLED AT 50 FT INTERVALS WHEN THE DUCT LENGTH EXCEEDS 50 FT. I`•1f CG'Ti=f1T ANY DEVIATION FROM ANY ❑F THE MANUFACTURER'S RECOMMENDATIONS IN THIS DOCUMENT OR THE OPERATION AND INSTALLATION MANUAL MUST BE APPROVED BY THE OWNER DE THIS EQUIPMENT AND VOIDS THE WARRANTY AND PERFORMANCE GUARANTEE OF THIS PRODUCT DUE: 2/23/2021 ONGX: 4647383 UMN RTB - 85 BE SOLE: 3/4" = 1 '-0" MPSTERMWING RECEIVED Mar 05 2021 Es SHEET NO. 2 1.5' I.P.S. DRAIN DROP. 1.5' I.P.S. DRAIN DROP I-VSIONS \ BOTH ENDS. DESCRIPTION I DATE: � a � 7' i 7.00" 24.00' 0181- r I t-�- -� 1 I.P.S. CON ONNECTION. - 3/4 I,P,S, CONNECTION, 3/4 LP , CONNECTION, _ I_ ❑ ❑ SLPCON-30FT KIT O HOOD # 1 (Main - Left) JOB # 4647383 MODEL: ND-2-PSP-F SIZE: 78'x30' LENGTH; 7' 3' unnn ronN:T MINIMUM 24' CLEARANCE 18' DIA. ABOVE HOOD, REQUIRED HOOD DUCT FOR MAINTENANCE. 1/4TT+TP1530+CP1325 DUCT NOZZLE. 12.00'�31.50` �31.50' 3070-3/8H-SS10 3070-3/8H-SS10 3070 ADJUST DUCT NOZZLE 5' -1 FROM VERTICAL TO POINT SLIGHTL TOWARDS BACK OF RISE EXHAUST RISER. HANGING ANGLE. 20' CAPTRATE SOLO FILTER WITH HOOK, 1' LAYER OF INSULATION FACTORY INSTALLED IN 3' INTERNAL STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 1.5' I.P.S. FINAL DRAIN DROP LOCATION ALL NECESSARY FITTINGS FROM THE VENTILATOR TO THE BUILDING WASTE LINE(S), I.E. FLOOR SINKS, AIR GAPS, OR OTHER DEVICES REQUIRED BY THE GOVER DRAIN RNING CODES, BY OTHERS. ENGDRAIN ERNE MUST BE RESPONSIBLE IS INSTALLED ED PER LOCALE`EdDE" P; YRKEL�aE�HA� BE SLOPED (MINIMUM W INCH PER FOOT), AVOID ANY UNNECESSARY 90 DEGREE TURNS, IF COMBINED WITH OTHER DRAIN LINES, THEN PIPE SIZE SHOULD BE INCREASED ACCORDINGLY. P-TRAPS SHOULD NOT BE USED IN THE GREASE DRAIN LINE AND HEAT TAPE MUST BE USED WHERE DRAIN LINE IS RUN IN ENVIRONMENTS THAT WOULD SOLIDIFY GREASE. d 24.00' 016[ ki I.P.S. CONFECT SLPC 1-03FT KIT O 3/4 I.P.S. CONNECTION. HOOD # 2 (Main - Right) JOB # 4647383 MODEL: ND-2-PSP-F SIZE; 60'x30' LENGTH; 16' 0' 16' DIA. HOOD DUCT 1/4TT+TP1530+CP1325 DUCT NOZZLE. E10' 12.00'J7::j 33.6 ' S10 3070-3/81H-SS10 I 0' I 26 01 CC CL' ~QZ J Z p T W a.. La E H ~ J Q W a W U � L.j< Wvo X o `o 0 W3p� _ a-p�vx U 110_J 0_mX AIM TOWARD CENTER TO APPLIANCE (30' MIN) 33.60' 0-3/8H-SS10 SECTION VIEW - MODEL 783OND-2-PSP-F HOOD - # 1 DUCT NOZZLE AND PLENUM SPRAY BAR LOCATION O 016' -S. CONNECT 33.60' 3070-3/8H-SS10 p m p� J Z N 4-pxx p H O J ~ W 0 W H = o O El,L3.'D U O_= 16' DIA. HOOD DUCT 1/4TT+TP1530+CP1325 DUCT NOZZLE. 33.60' � 33.60' 3070-3/8H-SS10 3070-3/8H-SS10 RECESSED ALLANSON ROUND LED FIXTURE AND I OUTPUT. ADJUST DUCT NOZZLE 5' -1 FRUM VERTICAL TO POINT SLIGHTL TOWARDS BACK OF RISE J FACTORY INSTALLED : 0 INCH aRANCE TO COMBUSTIBLE EXHAUST RISER. HANGING ANGLE. rTACHING PLATES. UPPLY RISER WITH IOLUME DAMPER. 23.5% OPEN STAINLESS 20' CAPTRATE SOLO STEEL PERFORATED PANEL. FILTER WITH HOOK. 1' LAYER OF INSULATION FACTORY INSTALLED IN 3' INTERNAL STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 700,A_a 1.5' WATER CONNECTION 7.00" ;ORE �uc Plenum Cov age DEDICATED WATER LINE FOR CORE FIRE SYSTEM 30.00-70 PSI OPERATING PRESSURE 125 PSI MAXIMUM STATIC PRESSURE 36.9 GPM MINIMUM K FACTOR 8.3, WATER LINE FOR SELF CLEANING SYSTEM 30-70 PSI OPERATING PRESSURE 125 PSI MAXIMUM STATIC PRESSURE 140 - 170 DEG F 16.3 GPM MINIMUM K FACTOR 3.6 410110%wr�11� �.I.pilux millm IMPORTANT, DEDICATED WATER LINE FOR SELF CLEANING MUST BE MIN 45 PSI OPERATING PRESSURE AT THE BACKFLOW PREVENTER INLET TO OVERCOME THE PRESSURE LOSS DUE TO FIELD PIPING. NOZZLE HEIGHT 30-55' FROM COOKING SURFACE. E­,-�MLIUNTEB PULL STATION IN PATH OF EGRESS TOWARD KITCHEN IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 1.5' I.P.S. FINAL DRAIN DROP LOCATION ALL NECESSARY FITTINGS FROM THE VENTILATOR TO THE BUILDING WASTE LINE(S), I.E. FLOOR SINKS, AIR GAPS, OR OTHER DEVICES REQUIRED BY THE GOVERNING CODES, BY OTHERS. ENGINEER IS RESPONSIBLE FOR DRAIN LINE DESIGN BEYOND THE HOOD. DRAIN LINE MUST BE INSTALLED PER LOCAL CODES, DRAIN LINE MUST BE SLOPED (MINIMUM W INCH PER FOOT), AVOID ANY UNNECESSARY 90 DEGREE TURNS, IF COMBINED WITH OTHER DRAIN LINES, THEN PIPE SIZE SHOULD BE INCREASED ACCORDINGLY. P-TRAPS SHOULD NOT BE USED IN THE GREASE DRAIN LINE AND HEAT TAPE MUST BE USED WHERE DRAIN LINE IS RUN IN ENVIRONMENTS THAT WOULD SOLIDIFY GREASE. CORE APPLIANCE PIPING WATER FLOW SUMMARY PIPE MINIMUM FLOW PRESSURE DROP DIAMETER RATE (GPM) (PSD FIELD PIPING BETWEEN ALL 1.5 36.9 0.00 HOOD GROUPS HOOD INTERNAL PIPING 0.75 16.3 30 SELF CLEANING WATER FLOW SUMMARY PIPE DIAMETER MINIMUM FLOW RATE (GPM) PRESSURE DROP (PSI) FIELD PIPING BETWEEN ALL HOOD GROUPS 1.5000 16.3 0 HOOD INTERNAL PIPING 0.75 16.3 30 BACKFLOW PREVENTER 1 1/2' 16.3 15 TOTAL SYSTEM INLET REQUIREMENTS WATER HEATER MINIMUM FLOW MINIMUM INSTANTANEOUS RATE (GPM) PRESSURE (PSI) DEMAND (MBH) TOTAL CORE INLET REQUIREMENTS 36.9 30.00 TOTAL SELF-CLEANING INLET REQUIREMENTS 16.3 45 700 ■ OPERATING PRESSURE RANGE AT CORE PANEL GAUGE IS 30.00 TO 70 PSI. MAXIMUM STATIC PRESSURE IS 125 PSI. ■ OPERATING PRESSURE RANGE AT Self Cleaning PANEL GAUGE IS 45 TO 70 PSI. MAXIMUM STATIC PRESSURE IS 125 PSI. ■ HOT WATER TEMPERATURE RANGE FOR SELF CLEANING 140-170°F. SECTION VIEW - MODEL 603OND-2-PSP-F HOOD - #2 DUCT NOZZLE AND PLENUM SPRAY BAR LOCATION I ROUND LED FIXTURE AND WARM OUTPUT. TTACHING PLATES. :UPPLY RISER WITH /OLUME DAMPER. 23.5% OPEN STAINLESS STEEL PERFORATED PANEL. NOTES - FIELD PIPE DROPS AS SHOWN ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS. - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSIONS LISTED REPRESENT THE CO❑KING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS FIRE SYSTEM C❑MPLIES WITH U.L. 300 REQUIREMENTS. - MINIMUM 24' CLEARANCE ABOVE HOOD, REQUIRED FOR MAINTENANCE. - CORE / SELF CLEANING (UNITED STATES) - US PATENT 7963282 B2. CORE / SELF CLEANING (EUROPE) - EP PATENT 2274069 Al. CORE SUPERVISI❑N - US PATENT 8378834 B1, CORE ELECTRICAL - US PATENT 8610601 B2. JOB #: 4647383. JOB NAME: CHARCOAL ART STUDI❑ RESTAURANT - 2020 R1 HEELS, SYSTEM SIZE: CORE HOOD # 1 7' 3.00' LONG x 78' WIDE x 30' HIGH. RISER # 1 SIZE: 18' DIA. HOOD # 1 METAL BLOW -OFF CAPS INCLUDED. HOOD # 2 16' 0.00' LONG x 60' WIDE x 30' HIGH. RISER # 1 SIZE: 16' DIA. RISER # 2 SIZE: 16' DIA. HOOD # 2 METAL BLOW -OFF CAPS INCLUDED. - S❑LID-FUEL APPLIANCES (EXTRA HEAVY-DUTY RATED 700°F) REQUIRE AN ADDITIONAL FIRESTAT AT END OF THE EXHAUST DUCT NEAR EXHAUST FAN IF THE DUCT IS MORE THAN 10 FT LONG OR CONTAINS ANY HORIZONTAL SECTI❑NS. - SOLID -FUEL APPLICATI❑NS WHERE THE DUCTWORK EXCEEDS 50 FT IN LENGTH WILL REQUIRE A THIRD FIRESTAT, MOUNTED IN A SERVICEABLE L❑CATI❑N, IDEALLY AT THE END OF A H❑RIZ❑NTAL RUN OR TRANSITI❑N. CONSULT ENGINEERING ON DUCT LENGTHS OVER 100 FT. - HEAVY-DUTY APPLIANCES (RATED 600°F) WILL REQUIRE AN ADDITI❑NAL DOWNSTREAM FIRESTAT IN THE EVENT THAT THE DUCTWORK C❑NTAINS ANY HORIZ❑NTAL RUNS OVER 25 FT IN LENGTH. - MEDIUM TO LIGHT -DUTY APPLIANCES (RATED 450°F) WILL NOT REQUIRE ANY ADDITIONAL DOWNSTREAM DETECTI❑N. Hood # 2 1/4TT+TP1530+CP1325 ADJUST DUCT NOZZLE 5` - 10° TOWARDS BACK OF RISER. 13' t 1/2' SPACING (TYPICAL). i i� 1/4TT+TG-4.3W (TYPICAL FOR ALL PLENUM NOZZLES). 30' MAX SPACING OVER DUCT v �i II I I i II II 36' SPACING MAX 3070-3/BH-10-SS (TYPICAL). APPLIANCE PROTECTION NOZZLE (TYPICAL FOR ALL APPLIANCE PROTECTION NOZZLES). NOZZLES FOR CORE PROTECTION DESCRIPTION PART NUMBER A/X RISER NOZZLE 1/411 +1 P1530+CP1325 A0002784 SPRAY BAR NOZZLE 1/41111U-4.3W A0025166 APPLIANCE NOZZLE I 3070-3/8H-10-SS A0019145 IS❑METRIC VIEWS ARE FOR GRAPHICAL REPRESENTATION OF TYPICAL NOZZLE PLACEMENTS AND TYPE. QUANTITIES OF NOZZLES WILL VARY, +� 0 D O W +� V QJ CD � v) l__J 0 CD � CLJ W DUE: 2/23/2021 ONGX: 4647383 EFVWN RTB - 85 BE SOLE: 1/2" = 1 '-0" MPSTERMWING RECEIVED Mar 05 2021 -T-NT Es SHEET NO. 3 JOB NO MODEL NUMBER DRAWN BY SCIIEMAIIC TYPE 4647383 DCV-2111 INSTALL JOB NAME DATE DWG Na Charcoal Art Studio Restauran.,. 2/23/2021 ECP #1-3 1 CORE TOTAL FLOOD PROTECTION ELECTRICAL DETAIL 2 ELECTRICIAN: 1, WIRE MAIN CONTROL PANEL PER INCLUDED SCHEMATIC _ 2, WIRE ALL FANS PER INCLUDED SCHEMATIC 3 3. WIRE SHUNT TRIP BREAKER (OPTIONAL) 4, WIRE UDS APPLIANCE KILL SWITCH, IF EQUIPPED (OPTIONAL) 5, WIRE GAS VALVE 4 5 6 7 8 11LSCRIH 11UN UI UH'LKA 11UNI JOB NO MODEL NUMBER DRAWN BY SCHEMATC TYPE I 11L SCK1H' 11UN LIF UHLKA 11UNI Fire System #1 CORE Protection. 1-1/2' CORE Appliance Manifold Package with Self Cleaning, Installed In Hood Utlllty DCV-2111 INSTALL Fire System #1 CORE Protection. 1-1/2' CORE Appliance Manifold Package with Self Cleaning. Installed in Hood Utlllty Cabinet with Integral hood prewire panel. 4647383 JOB NAME BATE DWG NO Cabinet with Integral hood prewire panel. Charcoal Art Studio Restauran... 2/23/2021 ECP #1-4 1 03/06/2017 Rev. 12 CORE TOTAL FLOOD PROTECTION LOW -VOLTAGE DETAIL 03/06/2017 Rev. 12 2 ALARM CUNTRACTORI r F S- 1: M A S T E R L 2. COMPLETE L ACTUATIONL HOOKUP DEVICES), REMOTE FIRESTAT(S), CORE INTERLOCK(S), FIRE SENSOR(S) AND FIRE ALARM CONTACTS F S- 1: MASTER 3, PERFORM FINAL FIRE SYSTEM TEST 4, FILL SURFACTANT TANK ELECTRICAL CONTRACTOR REQUIREMENT ITEM CONNECTION IN PANEL CONNECTION IN DEVICE VOLTAGE AMPERAGE COMMENTS SHUNT TRIP BREAKER (OPTIONAL) ST & N1 BREAKER COIL (A1 & A2) 120 VAC < 4 AMPS ST TO Al ON SHUNT BREAKER COIL, AND NEUTRAL TO A2 ON SHUNT TRIP BREAKER COIL CONTROL PANEL POWER H1 & N1 + GROUND CIRCUIT BREAKER 120 VAC 15 AMPS CONTROL PANEL POWER MUST NOT BE RUN THROUGH SHUNT TRIP BREAKER UDS APPLIANCE KILL SWITCH (OPTIONAL) KTS & N1 KTS & N1 120 VAC ( 4 AMPS KILL SWITCH TERMINALS MUST BE IN SERIES WITH OTHER KILL SWITCHES REMOTE 120VAC ANSUL AUTOMAN (OPTIONAL) AU1, AU2 SOLENOID 120 VAC ( 6 AMPS 120V TO AU1, AU2 TO ANSUL ELECTRIC AUTOMAN, ANSUL SOLENOID TO NEUTRAL GAS VALVE 35 & N1D (IF 24 VDC) GAS & Ni (IF 120 VAC) RED/RED/GREEN 24 VDC OR 120 VAC < 1.0 AMPS IF 24 VDC - 2 WIRES & GROUND, N1D TO RED, 35 TO RED, AND GREEN TO GROUND IF 120 VAC - 2 WIRES & GROUND GAS TO RED, Ni TO RED, AND GREEN TO GROUND 9 10 11 12 13 SHUNT TRIP BREAKER (OPTIONAL) -2 WIRES, 120VAC 14 -ST TO Al ON SHUNT BREAKER -NEUTRAL TO A2 ON SHUNT TRIP BREAKER 15 16 17 18 POWER TO ELECTRIC APPLIANCE 19 — _ CONTROL PANEL POWER ------------� ---- — 2 WIRES & GROUND -120 VAC, 15 AMP SERVICE -WIRE TO H1 AND N1, GROUND FROM -POWER HUNT MUST NOT BREAKERTE EXHAUST HOOD 36 INCHES CLEARANCE REQUIRED IN FRONT OF ALL UTILITY CABINET DOORS THE PANEL SHALL ALSO BE LOCATED IN AN ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN 20 _ — — ELECTRIC GAS 21 22 27 23 COOKING APPLIANCE(S) 24 - NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 JOB NO MODEL NUMBER DRAWN BY SCHEMATIC TYPE 4647383 DCV-2111 INSTALL JOB NAME DATE DWG No Charcoal Art Studio Restauran.,. 2/23/2021 ECP #1-5 CORE TOTAL FLOOD PROTECTION LOW -VOLTAGE FIGURES USE BELDEN #6320UL OR SIMILAR WIRE J2-1 J10-1 J2-2 J10-2 MICROSWITCH/ MANUAL ACTUATION FIRE DEVICE STAT-1 NO-WH BK-C Mk-M DOOR-FBREAK WIRE BK-C (OR RD) BREAK WIRE 1 2BEFORE BEFORE MANUAL INSERTING INSERTING ACTUATIOINTO FIRE TERMINALS DEVICE TERMINALS STAT-2 NO-WH BK-C �{� BK-C (OR RID 1 2 OR F J2-3 J10-3 J2-4 J10-4 WIRING CONNECTIONS WIRING CONNECTIONS FOR FIRESTAT LOOP FOR MANUAL ACTUATION LOOP FIGURE 1 FIGURE lA SHIELDED TWISTED PAIR =RD K BK A RD WIRING CONNECTIONS FOR CORE INTERLOCK FIGURE 3 NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS BUILDING FIRE ALARM CORE CONTROL PANEL TROUBLE CONTACT TOK TBL NO TROUBLE INPUT TBC GAS VALVE POWER -2 WIRES & GROUND -24 VDC WIRE TO 35 & N1D -120 VAC WIRE TO GAS & N1 -STRAINER MUST BE INSTALLED UPSTREAM OF VALVE Fire System #1 CORE Protection. 1-1/2' CORE Appliance Manifold Package with Self Cleaning. Installed In Hood Utility Cabinet with Integral hood prewire panel. 02/05/2015 Rev. 16 ES-1: MASTER BUILDING CONTROL FIRE ALARM PANEL FIRE ALARM CONTACT ALARM AL2 N INPUT OF LINE A DEVICE WIRING CONNECTIONS FOR FIRE ALARM CONTACT FIGURE 2 PRV WATERLINE CORE WATER SUPERVISION SUPERVISION SHUT-OFF SWITCH SWITCH SWITCH 0 NC 1 C WIRING CONNECTIONS FOR TROUBLE CONTACT FIGURE 4 4 5 6 7 8 9 10 ALARM CONTRACTOR REQUIREMENT ITEM CONNECTION IN PANEL CONNECTION ON DEVICE VOLTAGE AMPERAGE COMMENTS 101 AND 104 WIRE MANUAL ACTUATION DEVICE TERMINAL 1 BETWEEN CORE PANEL TERMINALS 102 AND 103 MANUAL ACTUATION DEVICE(S) 102 AND 103 1 & 2 24 VDC ( 1.0 AMPS WIRE MANUAL ACTUATION DEVICE TERMINAL 2 BETWEEN CORE PANEL TERMINALS 101 AND 104 JUMPER 101 TO 104 AND 102 TO 103 IF NO MANUAL ACTUATION DEVICE IS INSTALLED MANUAL ACTUATION DEVICE COVER N/A N/A N/A N/A MANUAL ACTUATION DEVICE COVER MUST BE INSTALLED IF SURFACE MOUNTED, USE COVER EXTENSION STI-6531B REMOTE FIRESTAT SENSOR(S) 21 AND 24 BLACK AND WHITE 24 VDC ( 1,0 AMPS --WIRE FIRE SENSUR WHIIE WIRES BEIWEEN HUUB LURE HANEL IEKMINALS EE AND E3 WIRE FIRE SENSOR BLACK WIRE BETWEEN HOOD CORE PANEL TERMINALS 21 AND 24 22 AND 23 HIGH TEMP (842°F) #CW04427 (WHT) & #CW04427B (BUOWIRE OR SIMILAR ONLY IF RAN OVER TOP OF HOODI OTHERWISE BELDEN #6320UL OR SIMILAR PLENUM RATED WIRE! SFF FIGURE I FIRE ALARM CONTACT ALL AL2 VARIES 50V MAX UP TO 1 AMP FIRE ALARM RELAY CONTACTS FOR BUILDING FIRE ALARM LOCATED IN THE (AC/DC) CORE ELECTRICAL CONTROL PANEL CORE INTERLOCK(S) ILA, ILB, ILC ILA, ILB, ILC RS-485 COMMUNICATIONS CORE SYSTEM (1) ILA, TO CORE SYSTEM (2) ILA, CORE SYSTEM (1) ILB, TO CORE SYSTEM (2) ILB, SIGNAL CORE SYSTEM (1) ILC, TO CORE SYSTEM (2) ILC. USE BELDEN# 88760 OR SIMILAR WIRE TROUBLE CONTACT TBC, TBL, TOK VARIES MAX 120 VAC UP TO 6 AMPS WIRE TO TBL & TBC NORMALLY OPEN CONTACT, CLOSES IN TROUBLE CONDITION CORE COMMUNICATIONS CABLE RJ-45 Jack INTERNET CONNECTION SIGNAL 0.0 AMPS TYPICAL CONNECTION CATS CABLE TO LOCAL AREA NETWORK VIA ETHERNET SWITCH OR WIRELESS ROUTER WITH VALID INTERNET CONNECTION 11 FIRE ALARM CONTACT -�i� — FIRE ALARM PANEL CORE INTERLOCK 12 -2 WIRES WIRED TO NORMALLY -2 WIRES + SHIELD OPEN CONTACTS (CLOSES IN f _ _ _ -USE BELDEN#88760 OR SIMILAR WIRE FIRE CONDITION) _ _ _ _ _ _ _ — — I — — — -SEE FIGURE 3 13 -CORE CONTROL PANEL AL1 — — — — — — AND AL2 -SEE FIGURE 2 14 TROUBLE CONTACT �II -2 WIRES TO NORMALLY III CORE COMMUNICATIONS CABLE OPEN CONTACTS (CLOSE -CATS CABLE IN TROUBLE CONDITION) MUST BE INSTALLED TO A LOCAL AREA 15 -CORE PANEL TERMINALS NETWORK WITH VALID INTERNET ACCESS TBL AND TBC VIA ETHERNET SWITCH OR WIRELESS - -SEE FIGURE 4 MANUAL I ROUTER s ACTUATION I DEVICE SUPERVISED LOOP EXHAUST HOOD 10 TO 20 17 -4 WIRES, 24VDC CONNECT BLACK FEET FROM WIRES BETWEEN 21 AND 24 IN PANEL, CONNECT WHITE (OR RED) WIRES HOOD LOCATED BETWEEN 22 AND 23 IN PANEL NEAR POINT 18 -ADDITIONAL FIRESTATS, WIRED IN OF EGRESS I MANUAL ACTUATION DEVICE WIRES SUPERVISED LOOP FROM HOOD -4 WIRES, 24VDC WIRE (TERMINAL 1) -USE HIGH TEMP (842°F) #CW04427 BETWEEN 1R2 AND 103 19 (WHT) & #CW04227B (BLK)WIRE ONLY -WIRE (TERMINAL 2) BETWEEN 101 AND 104 IF RAN OVER TOP OF HOOD; -ADDITIONAL PULL STATIONS WIRED IN OTHERWISE BELDEN #6320UL OR SUPERVISED LOOP SIMILAR PLENUM RATED WIRE -USE BELDEN #6320UL OR SIMILAR WIRE 20 -SEE FIGURE 1 -SEE FIGURE 2 42 TO 48 INCHES ABOVE FLOOR 2t 36 INCHES CLEARANCE REQUIRED IN FRONT LEVEL TO MANUAL ACTUATION DEVICE PART #STI-SS2431 OF ALL UTILITY CABINET DOORS ELECTRIC GAS CENTER OF PUSH PROTECTIVE COVER MUST BE INSTALLED THE PANEL SHALL ALSO BE LOCATED IN AN STATION 22 ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN 23 COOKING APPLIANCE(S) 24 ATTENTION: LOW -VOLTAGE DC OR SIGNALING WIRE SHOULD - BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS 1 CORE APPLIANCE REV 1.8 ONE WH HN1 BK 16AWG o 1 PNi 1606-XLP-60EQ LN1. Adjust power supply to 27.5 PSM-2 60W Volts with an accurate Digital Volt Meter or with an HMI plugged into the CORE +- board. 2 3 4 DR� Fire Re(( L R 6BKURFACTANT LOW 5 RD FIRE IN ICATOR pp 0 RD' O IR LL-1 Audible Alarm BK BK Liquid Level Sensor RD BT-01PK 6 Prime / Reset RDSW-05-20R Test a rmed Wat�er�//Valvea3sinGY Supervl�Sionwitch 7 q 2 AlY1END RDSW-O BROF Door Tamper Switch LINE RD-16 C DEVICE RD BL/RD Hot Water Relay RD-19 RD RD/GN Equipment Relay ATTENTION: LOW -VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES Auxiliary Interlock Relay 9 To Building Fire Alarm Panel FIRE ALARM SYSTEM DRY CONTACTS. Termials ALI & AL2 make In FIRE. + RI 5 AMP FUSE Q DISCONNECT J1 24 VOLT BATTERY PACK FOR SHIPMENT + Ii Bk -2 PCB-2 J3- Jumper If water valve supervision switch is used PK RD RD 24V DC LLJ p Gas Valve Rt Y11WH Surfactant Pump Plenum Test ATTENTI❑N: LOW -VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE C❑NDUIT FROM ALL AC SOURCES, FS-1: MASTER s HIGH TEMP WIRE (842 F), PN- SLPCON-.FT required B� FS-01 I for all Supervised Loop wiring in contact with a FIRE STAT SUPERVISED LOOP hood. All other wiring May be mixed factory and field Stnt shall be PN- 632OUL, wiring. See Installation Schematic. Fire Belden or similar. Factory Multiple fire sensors possible. FS-02 mounted hood sensors will be terminated at junction box on top of hood. B J Fire Stat R - R� 7 Auxiliary Interlock (AUX-01), MS-01 Wire AU1 / AU2 of adjacent Master CORE BK C/ panel(s) in each manual activation loop for simultaneous activation. � MANUAL Micro - SW AU1/AU2 will have continuity for 10 SYSTEM LOOPATION LOOP / REMOTE FIRE AUX-01 seconds if adjacent panel goes Into fire Multiple manual actuation possible. LAU, condition, activating this CORE Panel but A Plug jumper with wires from pinl to djacen allowing for a reset after 10 seconds. pin4 and from pint to pin3 should be CORE NOTE, AU1/AU2 terminals of CORE Panel mounted on J10 If there Is no manual actuation device and no microswltch. Panel should not be wired Into its own manual �_ activation loop. BK Manual Actuation RD Device- CAT-5 WIRING (MASTER ONLY) J FEEU WIRED IF REMOTE PREWIRE ECPM03 -PUT END OF LINE PLUG IN EMPTY RJ45 UNLESS VFD, PCU, OR OTHER COMPONENT IN SERIES. SHIELDED TWISTED PAIR BK BK CA RS-485 CORE INTERLOCK NETWORK. Connection to other CORE Panels or RD RD CD Communication Module. See Installation Schematic for Connection. Master CORE DIP Switch totCLIP SW OSED 8 position. Slave 1 2 3 4 5 6 7 8 CORE with address 1 set B DIP 8 to • O O O • O O • CLOSED ,n position. All O • • • O • • • other CORES OPEN set DIP SW 8 OPEN. FIRE INDICATOR FAULT CONDITION FLASH CODES 2 CORE Plenum Water Solenoid 3 CORE Appliance Water Solenoid 4 Auxiliary Fault 5 Microcontroller Fault 6 CORE Surfactant Pump 7 Supervised Loop 8 Ground Fault 9 Surfactant Low 10 Battery Voltage Low 11 AC Power Failure 12 Door Tamper Switch 13 Test mode 14 CORE Interlock Network 15 Fault on Hood in Interlock Network 16 Fault on PCU in Interlock Network GYL G 4WH WASH I DICATOR BK 16�AWG RD-16 OR RD -3 WH N1 Hot Water Wash Solenoid FACTORY WIRING SCHEMATIC CORE FIRE PROTECTION R 0 VAC 24 @ DC RELAY RELAY NO 4 3 NO 4 3 NC 2 1 NC 2 1 COIL 8 7 COIL 8 7 COM 6 5 COM 6 5 PCB-2 CURE PCB PCBCORE-APP PSM-2 CURE POWER SUPPL _ 1606-XLP-50E WS-x Water Solenoid -ries LT-06 24VRed Ind. Light _ PNL-HG3-0UR LL-01 Surf. Level Sensor A05510 AA-01 Audible Alarn _ SCE120LA3FPIB PB-01 Prine/Reset Switch D7-F2X11 SW-05 TEST/ARM Switch ZB5A➢2 SW-04 Tanper Switch _ BZ-2R01-A2 SP-1 Surfactant Pump _ 50000-805 GV-1 24v DC Gas Valve varles -FS-XX Duct Fire Sensor _ 12-F28021-000360 LT-05 24V YLW Ind Ligh _ PNL-1163-OUY PS-01 R—te Pull Statio STI-SS2431 -PWS-01 24VDC Power Su l _ 24VDC 18W POWER RD-XX 24VDC Phoenix Relay PLC-RPT-24➢C/21 - -WIIRING —FIELD FACTORY WIRING BK- BLACK YW- YELLOW BL- BLUE GY- GREY BR- BROWN PR- PURPLE OR- ORANGE RD- RED WH- WHITE GR- GREEN OR/BL- OR/DL STRIPE DRY CONTACTS (SHOWN DE-ENGERGIZED) - RD- 20 1 BL/RD- FL/RD STRIPE TROUBLE RELAY. Contact terminals 12 TBC & TBL make If there Is trouble. RD/GN- RD/GN STRIPE /BL- WH/BL STRIPE 14 Contact terminals TBC & TOK make IfWH — 11 YW the system Is ok. Jar NAME RD-19-1 COOKING EQUIPMENT DISABLE RELAY. Charcoal Art Stu For UDS Kill Switch, wire EKC and - 12 EKS terminals to like terminals in DR AWING TITLE 14 UDS panel. 11 YW DESCRPTIONI OF OPERATION 14 AWG RD-17-1 FIRE SYSTEM DRY CONTACTS. Fire System #1 CORE Protection. I-1/2' CORE 12 Dry contacts will make C2 to AR2 Appliance Manifold 14 when system Is armed. package with Self Cleaning. Installed in 11 YW Hood Utility Cabinet with Integral hood prewire panel. RD-18-1INTERLOCKFOR AUTOMAN ACTIVATION, 4647383 'm— Used for activating 120V n.tom.m TYPE DATE �14° or adjacent Master CORE panels 2/2 11 YW during active Fire Condition, DWG NO ECP #1-9 I-VSIONS DESCRIPTION I DATE: +� 0 CV O 00 � +� rn V ' QJ CD �i� I Q .--C 0 CD C d LLJ DUE: 2/23/2021 ONGX: 4647383 EFVWN RTB - 85 BE SOLE: 3/4" = 1 '-0" MPSTERMWING RECEIVED Mar 05 2021 — T—T Es SHEET NO. 4 IEVSIONS DESCRIPTION DATE: or JOB NO MODEL NUMBER 7� `' DC v -���� DRAVIN BY SCHEMATIC 7YPE 1NSTALL DESCRIPTI❑N OF ❑PERATI❑N: 4647383 Fire System #1 CORE Protection. 1-1/2' CORE Appliance Mnnlfold Package with Self Clenning. Instnlled in Hood Utility JOB NAME DATE DYfG NO Cabinet with integral hood prewlre panel. Charcoal Art Studio Restauran,., 2/23/2021 ECP #1-7 1 CORE TOTAL FLOOD PROTECTION SPRINKLER DETAIL_ 03/06/2017 Rev, 13 2 BUCONNECTPCORELWATER LINETTTO BUILDING WET SPRINKLER SYSTEM. STAINLESS STEEL, COPPER, OR STEEL PIPE ONLY 1. r c S - 1; MASTER 3 r SPRINKLER CONTRACTOR REQUIREMENT 4 ITEM CONNECTION OPERATING PRESSURE K-FACTOR FLOW RATE COMMENTS 5 WATER LINE MUST BE SUPERVISED AND HAVE NO UNSUPERVISED MANUAL SHUT-OFF CORE WATER SUPPLY LINE 1.5 INCH NPT 30.00 PSI TO 70 PS 8.3 36.9 GPM VALVES MINIMUM PRESSURE AND FLOWRATE DEPENDENT ON LENGTH OF HOOD SYSTEM s 1-1/2' MANIFOLD MINIMUM OPERATING PRESSURE REQUIREMENTS PRESSURE REGULATOR VALVE (PRV) -PRV NOT INCLUDED AND MUST BE PROVIDED INSTALLED AND ADJUSTED BY MINIMUM INLET MINIMUM INLET LENGTH OF WATER PRESSURE WATER PRESSURE 7 THE SPRINKLER CONTRACTOR TO MEET INCOMING PRESSURE REQUIREMENTS HOOD (FT) FOR HOT WATER FOR CORE (DISCHARGE -A REGULATOR SUCH AS THE ELKHART BRASS MODEL NUMBER URFA-20S-2,5' (PSI) PROTECTION (PSI) (K-FACTOR) OR THE UR-20 SERIES PARTS KITS SHOULD BE UTILIZED 4 30 30 1.3 -MUST BE CONFIRMED WITH THE FIRE MARSHAL OR LOCAL AUTHORITY s - - - - HAVING JURISDICTION (AHJ) 8 30 30 2.7 12 30 30 4.0 9 16 30 30 5.4 20 30 30 6.7 CORE WATER SUPPLY LINE 24 30 30 8.1 10 -30.00 PSI TO 70 PSI UP RAT NG 28 30 30 9.4 PRESSURE -125 PSI MAX STATIC 32 30 30 10.7 PRESSURE, 1.5 INCH NPT NPT 36 33 35 11,3 11 FITTING -36.9 GPM (1,5 GPM 40 35 40 11,8 PER FOOT OF HOOD) 44 38 45 12,4 12 -CONNECTED TO SUPERVISED, DEDICATED 48 40 50 12,9 LINE WITH NO UNSUPERVISED MANUAL SHUT-OFF VALVES !EXHAUST TOTAL FLOWRATE = K FACTOR x PRESSUR�4a 13 -CONNECT TO BUILDING FIRE SPRINKLER WATER LINE HOOD (REDUCE PRESSURE) WHEN REQUIRED 14 -STAINLESS STEEL, COPPER, OR STEEL PIPE ONLY 15 36 INCHES CLEARANCE REQUIRED IN FRONT OF ALL UTILITY CABINET DOORS THE PANEL SHALL ALSO BE LOCATED IN AN 16 ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN 17 18 19 ELECTRIC GAS 20 Y1 COOKING NOZZLE HEIGHTS ABOVE HAZARD APPLIANCES) NOZZLE ABOVE NOZZLE PART NUMBER HAZARD 22 MIN MAX 3070-3/8H-SS10 30' 1 55' 23 NOZZLES FOR CORE PROTECTION DESCRIPTION PART NUMBER MACOLA FLOW RATE 24 RISER NOZZLE 1/4TT+TP1530+CP1325 A0002784 2.6 GPMMS@ 30 NOTE; SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS SPRAY BAR 1/4TT+TG-4,3W A0025166 0.7 GPM @ 30 NOZZLE PSI PRESSURE REDUCING VALVE WITH SUPERVISION SWITCH, BALL VALVE SUPERVISION SWITCH AND PRESSURE MONITORING SWITCH (OPTIONAL) ATTENTION: LOW -VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES PRV SUPERVISION SWITCH -THE PRESSURE REDUCING VALVE MUST BE INSTALLED WITH AN APPROVED SUPERVISION SWITCH -SWITCH PART NUMBERS AND SUPPORT BRACKETS ARE LISTED IN THE TABLE -SWITCH COMES WITH TWO SINGLE POLE, DOUBLE THROW SWITCHES -SWITCH MUST BE ATTACHED PER PRESSURE REDUCTION VALVE BRACKET INSTRUCTIONS 0 VALVE SUPERVISION SWITCH BRACKET WATER PRESSURE SUPERVISION SWITCH -VALVE BRACKET CONTAINS NECESSARY PARTS -SWITCH IS AVAILABLE WITH A 1/2' NPT CONNECTION AND INSTRUCTIONS TO ADAPT THE SUPERVISION -PRESSURE MONITORING VALVE COMES WITH SWITCH TO THE VALVE, TWO SINGLE POLE, DOUBLE THROW SWITCHES, EACH ® ® WITH AN ADJUSTABLE SETPOINT PRESSURE REDUCING VALVE-SETPOINT CAN BE BETWEEN 10 AND 60 PSI -VALVE IS AVAILABLE IN 1-1/2' NPT CONNECTIONS -PART NUMBER PL-PS402 08/06/2014 Rev, 9 D 0 -PRESSURE REDUCING VALVE (IF REQUIRED) MUST INSTALLED BEFORE THE CORE PROTECTION PANEL TO REDUCE SPRINKLER LINE INCOMING PRESSURE AND VOLUME -PRESSURE REDUCTION IS BASED UPON THE INCOMING PRESSURE AND VOLUME -SEE TABLE FOR OUTLET PRESSURE BE COMPLETE PARTS KIT UR-20 VALVE OUTLET PRESSURE PERCENTAGE SUPERVISION SWITCH SWITCH BRACKET UR-20-W KIT UR-20-W 28,77 PL-PC VS2 80574001 UR-20-X KIT UR-20-X 33.87 PL-PC VS2 80574001 UR-20-Z KI UR-20-Z 56.57 PL-PCVS2 80,574001 URFA-20-S URFA-20 I VARIABLE I INCLUDED I N/A UR-20 VALVE INCOMING PRESSURE (PSI) 50 1 60 70 80 90 100 110 120 130 140 150 160 170 UR-20-W 14.35 17.22 20.09 22.96 25.83 28.7 31.57 34.44 37.31 40.18 43.05 45.92 48.79 UR-20-X 16.9 20.28 23.66 27.04 30.42 33.8 37.18 40.56 43.94 47.32 50.7 54.08 57.46 OUTLET PRESSURE (PSI) UR-20-Z 28.25 33.9 1 39.55 45.2 50.85 1 56.5 1 62.15 67.8 1 73.45 1 79.1 84.75 1 90.4 1 96.05 URFA-20-S VARIABLE THE CORE PANEL CONTAINS TWO ISOLATED INPUTS FOR AUXILIARY SUPERVISION OF PRESSURE REDUCING VALVES AND PRESSURE SWITCHES, EACH SUPERVISION DEVICE ABOVE HAS TWO SINGLE POLE, DOUBLE THROW SWITCHES. THESE SWITCHES MAY BE WIRED IN PARALLEL TO THE CORE PANEL TERMINALS H1D AND 39. WHEN A FAULT IS DETECTED, THE CORE BOARD WILL SHUT DOWN THE GAS VALVE AND SH TRIGGER A LOCAL TROUBLE SIGNAL, AND ALERT ALL ATTACHED CORE PACKAGES. ALTERNATIVELY, THE SWITCHES FROM EACH DEVICE COULD BE CONNECTED TO THE TROUBLE INPUT OF THE BUILDING FIRE ALARM PANEL TO INDICATE A TROUBLE CONDITION. BOTH METHODS ARE SHOWN BELOW. CORE CONTROL CONNECTIONS PRV SUPERVISION SWITCH C� NC F_ 39 0 WATEPRESSURE S PERVISION SWITCH CORE WATER SHUT-OFF SUPERVISION SWITCH L--_C- - -_� 38 DN1D 0 BALL VALVE SUPERVISION SWITCH -SWITCH IS AVAILABLE FOR 3/4' TO 2' -MONITORS CORE WATER SHUTOFF -SEE TABLE FOR PART NUMBERS f ARTRNBMBER PIPE SIZE PL-RBVS-3/4 3/4' PL-RBVS-1 1' PL-RVBS-1-1/2 1-1/2' PL-RBVS-2 2' WIRING CONNECTIONS FOR TROUBLE CORE CONTACT BUILDING CONTROL FIRE ALARM PANEL PRV WATERLINE TROUBLE SUPERVISION SUPERVISION CONTACT SWITCH SWITCH /-�� /---\ /-- TROUBLE INPUT CORE WATEI. SHUT-OFF SWITCH TOK b b TBL NO b, b NC 10 02 1 U b 2 TBC C C C END OIN LE DEVICE 1 2 3 4 5 6 7 s s 10 JOB NO MODEL NUMBER `' DRAWN BY SCHEMATIC TYPE JESCK1N 11LJN LJH LJNEKA I ILJNI 4647383 DC v -2111 INSTALL Fire System #1 CORE Protection. 1-1/2' CORE Appliance Manifold Package with Self Clenning. Instnlled In Hood Utility JOB NAME I DATE DWG NO Cabinet with integral hood prewlre panel. Charcoal Art Studio Restauran,., 2/23/2021 ECP #1-6 CORE TOTAL FLOOD PROTECTION PLUMBING DETAIL 03/06/2017 Rev, 15 PLUMBER, 1, CONNECT HOT WATER LINE; )PVC, COPPER OR STAINLESS STEEL PIPE ONLY 2, CONNECT HOOD DRAIN(S) STAINLESS STEEL, COPPER, OR STEEL PIPE ONLY � �11 ll�dd 3, CONNECT ALL END -TO -END AND BACK-TO-BACK HOOD WATER LINE CONNECTIONS (PLUMBING IS FIELD SUPPLIED FOR THIS) FIELD PLUMBING MUST NOT EXCEED HEIGHT OF VACUUM BREAKER IN MAI�UTIUItY C1AB S T E R REMOVE PLUG FROM MAIN HOOD SPRAY BAR AND CONNECT TO NEXT HOOD STAINLESS STEEL, COPPER, OR STEEL PIPE ONLY 4, PLUMB GAS VALVE, STRAINER MUST BE INSTALLED UPSTREAM OF VALVE 5, INSTALL FLOOR DRAIN 6, INSTALL BACKFLOW PREVENTER IF CODE REQUIRES PLUMBING CONTRACTOR REQUIREMENT ITEM CONNECTION TEMPERATURE PRESSURE FLOW RATE COMMENTS HOT WATER LINE L5 INCH NPT 140 to 170'F 30 PSI TO 70 PSI 163 GPM INSULATE HOT WATER PIPE, MINIMUM PRESSURE DEPENDENT ON LENGTH AND CONFIGURATION OF HOOD SYSTEM HOOD DRAINS) 1-1/2 INCH NPT N/A GRAVITY DRAIN SEE ABOVE 2 DRAINS ON 24 INCH TALL HOODS WITH 20 INCH TALL FILTERS AND HOODS 10 FEET AND LONGER END -TO -END CORE CONNECTION VARIES N/A N/A N/A CONNECT WITH NPT PIPE SEAL ALL THREADS HOOD CONNECTION PROVIDED BACK-TO-BACK CORE CONNECTION VARIES N/A N/A N/A CONNECT WITH NPT PIPE, SEAL ALL THREADS, HOOD CONNECTION PROVIDED GAS VALVE VARIES N/A SEE TABLE N/A UP TO 2 INCHES NPT WITH 24V CONTROLS, 2-1/2 AND 3 INCH USE 120V CONTROL FLOOR DRAINS) 1-1/2 INCH N/A GRAVITY DRAIN N/A USED TO HELP CLEAN UP FIRE SYSTEM DISCHARGE, GREASE INTERCEPTOR MAY BE REQUIRED BACKFLOW PREVENTER DRAIN LINE (OPTIONAL) INLET/OUTLET DRAIN N/A VARIES N/A INSTALLED WHEN PACKAGE HAS A BACKFLOW PREVENTER VALVE, SEE BACKFLOW PREVENTER VALVE MANUAL FOR DETAILS HOT -125 PSI MAX STATIC PRESSURE 11 -16.3 GPM (0,7 GPM PER FOOT OF HOOD) -1.5 INCH NPT INCH NPT FITTING - INSULATED 12 END -TO -END OR BACK-TO-BACK CONNECTION 13 -INSTALLED AND PROVIDED BY PLUMBER STAINLESS STEEL, COPPER, OR - STEEL PIPE ONLY 14 HOOD DRAINS) - -1-1/2 INCH NPT CONNECTED TO 15 BUILDING GREASE TRAP -2 DRAINS ON 24 INCH TALL HOODS _ WITH 20 INCH FILTERS -2 DRAINS ON HOODS 10 FEET AND 1s LONGER -STAINLESS STEEL, COPPER OR STE PIPE ONLY 17 -SLOPED MINIMUM 1/4' PER FOOT, AVOID ANY UNNECESSARY 90' TURNS -PIPE SIZE SHOULD BE INCREASED 18 WHEN COMBINED WITH OTHER DRAINS -P-TRAPS SHOULD NOT BE USED IN 19 THE GREASE DRAIN LINE AND HEAT TAPE MUST BE USED WHERE DRAIN LINE IS RUN IN ENVIRONMENTS THAT WOULD SOLIDIFY GREASE 20 FLOOR DRAIN -1-1/2 DRAIN INSTALLED IN 21 -FLOOR NDRAINSPMAY BCE USED TO DRAIN HOOD -GREASE INTERCEPTOR MAY BE 22 REQUIRED 23 24 PIPE ONLY ELECTRIC COOKING APPLIANCE(S) PRESSURE REGULATOR VALVE REGULATORS ARE NOT INCLUDED TO MEET REQUIRED PRESSURE AND MUST BE ORDERED SEPARATELY - - - PART NUMBERS; X65BU(3/4'), X65BU(1'), OR X65BU(1-1/2') CONSULT FACTORY FOR SIZING I 1-1/2' MANIFOLD MINIMUM OPERATING PRESSURE REQUIREMENTS EXHAUST HOOD 36 INCHES CLEARANCE REQUIRED IN FRONT OF ALL UTILITY CABINET DOORS THE PANEL SHALL ALSO BE LOCATED IN AN ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN GAS NOTE, SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS VKPVC PIPING CANNOT BE WITHIN 10 FT OF HOOD, CONNECTIONS TO THE MANIFOLD MUST BE HARD PIPED WITH COPPER, OR STAINLESS STEEL. LENGTH OF HOOD (FT) MINIMUM INLET WATER PRESSURE FOR HOT WATER (PSI) DISCHARGE COEFFICIENTS (K-FACTOR) 4 30 0.6 8 30 1.3 12 30 1.9 16 30 2.5 20 30 3.1 24 30 3.8 28 30 4.4 32 30 5.0 36 33 5.4 40 35 5.9 44 38 6.2 48 40 6.6 TOTAL FLOWRATE = K FACTOR x PRESSURE0.44 GAS VALVE -THREADED NPT CONNECTION VE SIZE MAX INLET PRESSURE (PSI) VOLTAGE BTU/HR 3/4' 5 24VDC 593,200 1' 24VDC 1,132,300 1-1/4' 24VDC 1,925,000 1-1/2' 24VDC 1 2,406,000 2' 24VDC 2,940,500 2-1/2' 120VAC 5,607,800 3' 120VAC 5,661,700 +, O � CLI O 00 01 a) Q o_ Q C CD 0 0 � O � C-) C d LLJ DUE: 2/23/2021 ONGX: 4647383 UMN RTB - 85 BE SOLE: 3/4" = 1 '-0" MPSTERMWING RECEIVED Mar 05 2021 °EPA T-NT Es SHEET NO. 5