Loading...
APPROVED FIR FIR2022-0006+Fire_Alarm_Plan+1.15.2022_11.34.51_AM+2623252PRIMARY ALTERNATE �ma illi i"0 01 9 a� rn (V C14 00 Q [V r�-I ci 00 I� u- rn 0 cg� Ln 0 zt co co O (j a<:3 U U _ OJ _ *: — 1 — cd - OJ - DESK' JEFF BROSSARD NICET LEVEL 3 ID # 148093 L._ E: BROSSJB951 L7 REFERE�"`- 2018 IFC AND 2016 NFPA 72 z 0 N Q O N 000 cy) 0 — z w Z p� wz r o 0 w ;o OpLu �z O J cn Q Q >< =O No O z C0 G 0 W W ISSUES REV DATE DESCRIPTION TITLE' FIRE ALARM PLANS FLOORS 1 &2 DATE JANUARY 3, 2022 PROJE�, , IVIJ. 21-050 SHEET: FA-1 FIR2022-0006 RECEIVED Jan 17 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 9 a� ('n (V C14 00 Q [V —1-1 ci 00 I� Z=N rn0cg�Ln O 0 L` T coZm O ' (j aaJa U U _ OJ _ 7 _ 7� — 1 — cd - OJ - DESK' JEFF BROSSARD NICET LEVEL 3 ID # 148093 L._ E: BROSSJB951 L7 REFEREN" 2018 IFC AND 2016 NFPA 72 z 0 N Q O N 000 cy) 0 — z w Z p� wz r o 0 w ;o OpLu �z O J cn Q Q >< =O No O F-- z — Q DC 0 � > o w w w ISSUES REV DATE DESCRIPTION TITLE' FIRE ALARM PLANS FLOORS 3 & 4 DATE JANUARY 3, 2022 PROJE�, , 1VlJ. 21-050 SHEET: FA-2 FIR2022-0006 RECEIVED Jan 17 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT -0 120 VAC UNSWITCHED DEDICATED CIRCUIT TO TELCO ROOM DICE OF OPERATIONS Ln W Q J a z z oC OC Q ( O W p -1 a N 2 z W u O J Q z Q U z Q p Q H O F- z z zNT O? � J Q O O o Q Q F- F- z a_Q N m> -i Z ( (7 Q N Q Ov) U Lu OC W OQ LL N z LU J N J Zo (Dm ww 2O LU m= == zLu 0 F-u QO I= DI- �Lzu W H 0-Lu aoc or 1-- Q 1 Q u gnu X X X X X X X X X X X X X X X DESIGNED AUDIBILITY LEVEL PER OCCUPANCY CLASSIFICATION GROUP A 70db GROUP B 70db GROUP E 60db GROUP F 95db GROUP M 55db GROUP R 50db GROUP S 45db EQUIPMENT LEGEND DEVICE SYMBOL QUANTITY PART NUMBER DESCRIPTION BACKBOX 0 1 5208 SILENT KNIGHT FIRE ALARM CONTROL INCLUDED PANEL 0 1 5235 SILENT KNIGHT LCD REMOTE INCLUDED ANNUNCIATOR 0 4 2WB SYSTEM SENSOR SMOKE DETECTOR 4 SQUARE X 1-7/8" DEEP 0 6 5600 SYSTEM SENSOR HEAT DETECTOR 4 SQUARE X 1-7/8" DEEP (*) PROVIDED AND INSTALLED BY OTHERS EXISTING DEVICE TO REMAIN NEW OR EXISTING DEVICE RELOCATED # INDICATES CANDELA (E) INDICATES EXISTING C INDICATES CEILING MOUNT EOLM/- END OF LINE RESISTOR WIRE LEGEND TYPE DESCRIPTION A 18 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE B 14 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE C 18 AWG, 4 CONDUCTOR 'FPLR' JACKETED CABLE GENERAL NOTES: 1. ALL WORK IS TO CONFORM TO NATIONAL ELECTRIC CODE STANDARDS. 2. WIRING METHOD IS TO BE OPEN CABLING EXCEPT WHERE IT IS EXPOSED AND BELOW SEVEN FEET — THEN IT IS TO BE IN CONDUIT. 3. ALL JUNCTION BOXES, COVERS, AND BACK BOXES ARE TO BE PAINTED RED. 4. PULL STATIONS ARE TO BE MOUNTED AT 48" TO 53" ABOVE THE FLOOR. 5. ALL WALL MOUNT INDOOR HORNS, STROBES, HORN STROBES, AND SPEAKER STROBES ARE TO BE MOUNTED 80" ABOVE THE FLOOR OR 6" BELOW THE CEILING, WHICHEVER IS LOWER. 6. SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING: A) 36" INCHES AWAY FROM ANY AIR HANDLING SYSTEM DIFFUSER B) NOT IN CLOSE PROXIMITY TO ANY FLUORESCENT LIGHT FIXTURES 7. EXTERIOR HORN / STROBE SHALL BE MOUNTED ON THE TOP 2/3 OF THE OUTSIDE WALL OF THE BUILDING, AS HIGH AS POSSIBLE FOR MAXIMUM VISIBILITY FROM THE FIRE DEPARTMENT ACCESS ROADWAY. 8. ALL WIRING PENETRATING ANY FIRE RATED BARRIER SHALL BE SEALED WITH MATERIAL WHICH WILL PREVENT PASSAGE OF FLAME AND HOT GASES. m fV fV 00 Q N r�-I �I pp I�Z=N m0ocLn 0 (D m Z m O � cj a Q a U i DESIG" JEFF BROSSARD NICET LEVEL 3 ID # 148093 LICEI,4,�L- BROSSJB951 L7 2018 IFC AND 2016 NFPA 72 (1) 0 0 z 0 U N74 f Q i w J W ISSUES REV I DATE I DESCRIPTION TITLE: W w w J CQ G N • • • FIRE ALARM LEGENDS, NOTES AND RISER DIAGRAM DATE: JAN UARY 3, 2022 PROJEC, I Ivu.. 21-050 SHEET: FA-3 FIR2022-0006 RECEIVED Jan 17 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT