Loading...
REVIEWED FIR2022-0006+Fire_Alarm_Equipment_Specification_Sheets+1.15.2022_11.34.39_AM+2623250FIR2022-0006RECEIVED SILENT Model 5208 KNIGHT Jan 17 2022 Fire Alarm Control Panel CITY ®P EDMONDS DEVELOPMENT SERVICES 0 (1�) DEP,�fiME��Nfi with Digital Communicator by Honeywell 're Alarm Control Designed to REVIEWED G w with Your Systems Needs, OX, Without The Growing Pains. The SK-5208 is a micro dce3sbr ba�eef' Eon bL liFiNolkA thV�ta L listed communicator designed for applications requiring s ke detection, manual pull stations, and s inkler supervision. It features an easy to read LCD display with p ly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features • 10 zones, 8 Class B (Style B) and 2 Class A (Style D) or Class B (Style B) zones, expandable to 30 zones • Supervised zone expanders and 1/0 modules can be mounted remotely from the main control panel • Event History Buffer (150 events) with date/time stamp • All zones are compatible with 2- or 4-wire detectors • 8 selectable/programmable output patterns for notification appliance circuits • Built-in Digital Alarm Communicator Transmitter (DACT) • 4 Notification Appliance Circuits • 4 programmable general purpose relays • Programmable smoke verification, pre -alarm delay, cross zoning and enhanced verification mode features that can help minimize false alarms • Programmable from the built-in control panel touchpad, remote annunciator, or Windows@ SKSS downloading software • Direct connect port for on -site up/downloading with Windows@ SKSS downloading software • Built-in walk test feature • Single or dual interlock water releasing capability • Plex door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions • Programmable AC trouble relay • Built-in synchronization for appliances from AMSECO@, Gentex@, Faraday, System Sensor@, and Wheelock@ • Programmable date settings for Daylight Saving Time • Clock source setting options for 50 Hz, 60 Hz, or internal (uses the panel's internal clock) Specifications Operating Voltage: 24 VDC Primary AC: 120 Vrms @ 60Hz, 2A Total DC Load: 6 Amp Current Draw: Standby: 140 mA Alarm: 460 mA Flush Mounting Dimensions: Height: 24.75" (62.9 cm) Width: 14.5" (36.8 cm) Depth: 3-7/16" (8.73 cm) with 5/8" protruding Overall Dimensions: Height: 26-3/8" (67 cm) Width: 17-3/16" (43.66 cm) Total Depth: 4" (10.16 cm) Operating Temp: 32' to 120' F (0' to 49' C) Humidity: 10 - 93% noncondensing Optional Accessories • SK-5235 LCD Remote Annunciator • SK-5217 10 Zone Expander (2 max. per system) • SK-5280 Status Display Module (8 max. per system) • 7181 Fire Zone Converter • 5220 Direct Connect Module • 5824 Serial/Parallel Printer Interface Module SK-5208 • SKSS Downloading Software • Plex-2 Door Option Listings and Approvals • UL Listed • CSFM Listed • MEA approval 429-92-E Vol. XIII Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 1q pp, Telephone Line 2 I_ F Pp- Direct Connect For On -Site Programming 2 Class A (Style D) Pr or Class B (Style B): Initiation Circuits Programmable Form C Relays 8 Class B B (Style y ) Notification Initiation Circuits Appliance Circuits 3a 5235 Remote -pp- a®o Annunciators Elie 0 0 C) SBUS Devices FE___M f� - 5280, 5217, & 5824 Tc SILENT This document is not intended to be used for installation purposes. We try L3to keep our product information up-to-date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com MADE IN AMERICA FORM# 350318 Rev C © 2010 Honeywell International Inc. 3 SILENT KNIGHT by Honeywell SK-5235 Remote Annunciator Program and Operate the SK-5208 FACP from a Distance with the SK-5235 Remote Annunciator. The SK-5235 remote annunciator provides remote annunciation for the SK-5208 Fire Alarm Control Panel. The SK-5235 performs all system operations. It also provides trouble and alarm information and can be used for programming. The SK-5208 can support up to six 5235 Remote Annunciators. Call Silent Knight today for more information 1-800-328-0103. Operation When the system is normal and receiving AC power, the power LED is on and all other LEDs are off. Other LEDs turn on as the conditions occur. Users identify themselves to the control panel by entering a code on the annunciator. When a user presses a button, the annunciator piezo beeps and the LCD prompts the user to enter a code or other relevant information. Features SK-5235 Remote Annunciator • 2-line 16-character LCD display • Indicates Trouble, Alarm, Supervisory, and System Status Specifications Ordering Information conditions with LEDs and LCD Operating Voltage: 24 VDC SK5235 display Current Draw: Remote Annunciator • Each SK-5235 is individually Standby: 30 mA supervised by the SK-5208 Alarm: 50 mA FACP Dimensions: Compatible Products • Up to 6 per SK-5208 FACP Width: 7-3/16" SK5208 (18.26 cm)5" • Operation and appearance Height: Fire Alarm Control Panel comparable to the control (12.7 cm ) panel's on -board annunciator Depth: 1-1/8" • Can be wired up to 1500 ft from (2.86 cm) FACP Operating Temp: 32' to 120' F • OPR operator's key ships with (0° to 49° C) SK-5235, this key can be used Maximum Wiring to perform user operations, but Distance: 1500ft will not open the control panel door Approvals • MEA 429-92-E • CSFM 7165-0559:137 • UL Listed SK-5235 Remote Annunciator Engineering Specifications The contractor shall furnish and install where indicated on the plans, the Model SK-5235 Remote Annunciator. Module shall be of a LCD type with a 2X16 display. Module shall be capable of remote programming as well as providing alarm, trouble information along with resetting of alarms and silencing of trouble and alarm conditions. Module ID shall be programmed with a 4 position DIP. The control shall be capable of supporting up to 6 supervised SK-5235. Module shall be designed to mount on a dual gang electrical box with 18 gauge to 14 gauge wire. SILENT This document is not intended to be used for installation purposes. We try to 0 KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are by Honeywell subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com MADE IN AMERICA FORM# 350321 Rev C © 2010 Honeywell International Inc. 4,�� SYSTEM Photoelectric Smoke Detectors System Sensor i3- series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features • Plug-in detector line, mounting base included Large wire entry port • In -line terminals with SEMS screws • Mounts to octagonal and single -gang back boxes, 4-square back boxes, or direct to ceiling • Stop -Drop 'N Lock attachment to base • Removable detector cover and chamber • Built-in remote maintenance signaling Drift compensation and smoothing algorithms • Simplified sensitivity measurement • Wide-angle, dual -color LED indication • Loop testing via EZ Walk feature • Built-in test switch Agency Listings & F M X MEA MSFMWs LISTED APOapproved approved c 5911 3011446 7272-1653:152 290-01 " 313C93? Installation ease.The i3 line redefines installation ease with its plug-in design.This allows an installerto pre -wire bases (included with heads). The large wire entry port and in -line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug into the base with a simple Stop-Drop'N Lock' action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED - indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i3 protocol. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors in terms of percent -per -foot obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out -of -sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire P detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. (-L3) Smoke Detector Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 1357 (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single -gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre -wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent -per -foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual - color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 12/24V non -polarized Minimum: 8.5 V Maximum: 35 V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 NA maximum average; 4-wire: 50 NA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @ 24 V Peak Standby Current 2-wire: 100 uA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30 V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 1207 (0°C to 49°C); 2WT-B and 4WT-B: 327 to 1007 (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non -condensing Thermal Sensor 1357 (57.2°C) fixed Freeze Trouble 2WT-B and 4WT-B only:417 (5°C) Sensitivity 2.50/o/ft nominal Input Terminals 14 to 22 AWG Mounting LED Modes 3'/2-inch octagonal back box 4-inch octagonal back box Single -gang back box 4-inch square back box with a plaster ring Direct mount to ceiling Power -Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal 2W-B No Wiring Alarm Current 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter f_ SYSTEM �/ SENSOR m2cha System Sensor. 3825 Ohio Avenue • St. Charles, L 60174 Product specifications subjec[to009 System Sensotice.Vsit rystemsensoccom for Phone:800-SENSOR2•Fax:630-377-6495 urrentproductinformat5-03180i7-6/09latest version okhisdata sheet. A06-0318-007.6/09•#2169 4,�� SYSTEM 5600 Series Mechanical Heat Detectors System Sensor' 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non -life -safety installations where smoke detectors are inappropriate. Features • Multiple configurations for installations: — Single- and dual -circuit models — Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. • Plain housing for residential installations (Model 5601P) • Easy -to -use terminal screws • A broad range of back box mounting options: — Single gang — 3.5"and 4"Octagonal — 4"square with square to round plaster ring • Reversible mounting bracket Agency Listings 0i @ UDC AR S2101 3016008 CSG?0 7270-1653:0167 FM LISTED APPROVED Multiple configurations. The 5600 series offers a full -line of configurations to accommodate a broad range of applications. Both single- and dual -circuit models are available for low- and high - temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single -gang and octagonal back boxes. And these models accommodate four -square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface -mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/ rate -of -rise units are marked FX/ROR. The 5600 series also provides a post -activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. Specifications Mechanical heat detector shall be a System Sensor 5600 series model number , listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single -circuit or a dual -circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90oC), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate -of -rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate -of -rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Maximum Installation Temperature 5601 P, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150OF (65.6°C) Operating Humidity Range 5 to 95% RH non -condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601 P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194OF (90°C) Weight 6 oz. (170 grams) Rate -of -Rise Threshold 150F (8.3°C) rise per minute (models 5601 P, 5602, 5621, and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact 6-125VAC / 3A Ratings 6-28VDC / 1 A 125VDC / 0.3A 250VDC / 0.1A Input Terminals 14-22 AWG "yd (D 5601 P 5602, 5622 5603, 5623 5604, 5624 5621 Ordering Information 5601 P Single None 135°F (57°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194°F (90°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 1940F (90-C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 1350F (57-C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual Lettering `NOTE: Refer to NFPA72 guidelines for 1940F (90-C) Fixed Temperature spacing reductions when ceiling heights exceed 10 feet. 25 feet x 25 feet (7.62m x 7.62m) SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2013System Sensor. Product specifications subject to change without notice. Visit systemsensorcom Phone: 800 SENSOR2 •Fax: 630 377 6495 or current product information, including the latest version of this data sheet. SENSOR" www.systemsensor.com SPDS30001.7/13