Loading...
APPROVED ENG RESUB 4-Site_Plan+7.13.2022GRAPHIC SCALE 10 0 5 10 20 IN FEET) 1 INCH = 10 FT Ah DATUM: NA VD 88 qV TBM: NE UPPER FLANGE BOLT OF HYDRANT 16 N & 12'E OF SE CORNER OF THIS PARCEL ELEVATION = 164.25 (NA VD 88) EX. SS STUB Fi] U W w to SEWER CONNECTED TO STUB ASSOCIATED WITH SEA MOUNTIAN ESTATES. EX. SS SERVICE SS STORM DRAINAGE NOTES: 1. IF CATCH BASIN RIM TO INVERT ELEVATION EXCEEDS 5 FEET A TYPE ll MANHOLE WILL BE REQUIRED. SECTION 24, TOWNSHIP 27 NORTH, RANGE 3 EAST, W.M., SNOHOMISH COUNTY, WA CONSTRUCTION OF THE SINGLE-FAMILY RESIDENCE WAS ORIGINALLY PERMITTED UNDER PERMIT #BLD2018-1267, WHICH HAS EXPIRED. REFER TO APPROVED CIVIL PLANS UNDER THAT PERMIT FOR ALL ENGINEERING REQUIREMENTS. THE SUBJECT PLANS RECORD OF SURVEY ADDRESS STORMWATER AND SEWER REVISIONS FOR THIS VOL. 7/PG.124 PROJECT. ALL OUTSTANDING PROJECT INSPECTIONS SHALL BE COMPLETED UNDER CURRENT PERMIT#BLD2022-0497 PRIOR TO \I ISSUANCE OF FINAL CERTIFICATE OF OCCUPANCY. COORDINATE S I WITH CITY INSPECTOR TO ENSURE PROPER INSPECTION AND APPROVAL OF ALL REQUIREMENTS. I I DRIVEWAY SHALL BE SLOPED OR I CURB OR BERM ADDED TO DIRECT STORMWATER FLOWS TO THE I CATCH BASIN. X/ X_x 7 X � - / ° \ ° \ \ CB-2 AB \ / / EX. FENCE i TYPE 1 WGRATE 1 �O \ RE=154.20 s ��� / \� IE=153.20 (OUT) ------/----------�-------------�--------------------------------- - / I -\ CB=2-AB---�--- TYPE -PER COE STD DETAIL SD-363. A / l / r1E=151.05 (IN) JE=150.85 (OUT) \ \ / /x 55 -6" PVC ® 99 AB �� ° ° ° ° / ---�--�� DISPERSION ENCH AB \\� MN---------- ------ - - - - - - - - - aCONC RIVEWAY I d I PER COE STD ETAIL SD-632 \ I ° � I ° Z(10' L X 2' W 2' D) \) / / \ ' I I - - - ° (MAX ADE 14%) I � ° I° ° 4 / l � ` CO FOR SEWER I DS EL=150.38 / / / -_ AB ° PROPOSED DRY WELL / l IE=150.87 ° ° (20'L x 8'W x 8'D) / / ' l / AB ' I I R20' ° ° I TOP ELEV=t148.98 / 4" PVC STORM ' ° I / REFER TO DRAINAGE / / (/ PIPE (TYP) _ i I ( < i (� ° / AF�DENDUM DATED 02/07/2 EL=147.98 ' - - / FOR ADDITIONAL INF W070N / l AB - _ _ _� _ ' ° 1 "PVC WATER ° RY S DE SERVICE / / l DS EL=149.60 ; \ ° ° I ° a \ Il AB ° F ow (T) a ° a ° I ° I I I ° °ev1116, ------ -------- CONC ( I ) DS EL=151.00 ° ° I ' I I AB PATIO ° ; 3, 9 SF ' AB -- -------I--- -------° I----------- I K25' BSBL II PROPOSED ° I (101 x 8'W x 8'D) - I / / 25' BIBL TOP ELEV=f 149.77 Z 1 REFER TO DRAINAGE A o I I I ADDENDUM DATED 02107122 FOR ADDITIONAL INFORMATION I CO ® P/L FOR SEWER 4 EL=141.59 LANDSCAPE WALLS AB �� I II (TYP) I \ \ EX. FENCE \ \ 1 � I I li I AS -BUILT DECLARATION WE HEREBY DECLARE THAT THE ROAD, STORM DRAINAGE, GRADING AND OTHER IMPROVEMENTS ARE LOCATED AS SHOWN ON THESE RECORD DRAWINGS AND THAT THESE RECORD DRAWINGS ARE SUBMITTED ON A TRUE COPY OF THE APPROVED CONSTRUCTION PLANS 07113/22 ECT ENGINEER/SURVEY DATE W DATE: 02107122 m m 0 7, / I 0 AS-BUIL T NOTE: DOWNSPOUT (DS) INVERT ELEVATIONS (IE) WERE PROVIDED B Y- BROOKSIDE EXCA VA TING 15321 BROOKSIDE PL SNOHOMISH, WA 98290 EX. FENCE / i EX THICKENED EDGE PAVEMENT LANDSCAPE WALL NOTE: NO DRAINAGE WAS INSTALLED BEHIND LANDSCAPE WALLS. SURVEYOR MS WEBB SURVEYING, LLC 362 BUCK LOOP ROAD SEQUIM, WA 98382 PHONE: (360) 681-4858 P.O. BOX 177, SI L VANA, WA 98287 TEL: (360) 652-5820 EMAIL: mocengin eering(gfrontier. corn I I I I I I I I I ' � I ----- /------------------ DS EL=151.42 / I / AB / ------------------ ----- --I----- l / I j PRIVATE ROAD II I THE NOTATION OF AB (AS -BUILT) THROUGHOUT DOES NOT INDICATE APPROVAL OF UTILITY SYSTEMS THAT WERE INSTALLED WITHOUT PROPER INSPECTION INSPECTIONS I II I TBM EL=164.25' I I I EX FH IIDQII EX "SPEED LIMIT" SIGN I I EX MAILBOX I STAND I I EX PP I / I OF ALL UTILITY SYSTEMS ARE REQUIRED OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE PRIOR TO FINAL APPROVAL. GRADING ESTIMATE CUT.• 290 CY's FILL: 290 CY's THE GRADING ES77MATE PROVIDED FOR THESE PLANS IS APPROXIMATE, ACTUAL GRADING VOLUMES MAY VARY. CALCULATIONS DO NOT ACCOUNT FOR VARIOUS VOLUMETRIC CHANGES DURING THE EARTH WORK PROCESS. /n\ / PLAN APPROVED UNDER BLD2018-1267 SHOWED WATER METER BEING MOVED TO THE PROPERTY LINE. WATER METER LOCATION SHALL BE APPROVE BY EDMONDS Wj,kTER DEPT. PRIOR TO FINAL APPROVA . 0 Z m W m 0 I � m I U) 0 0 DRWY APPROACH PER COE STD DETAIL TR-546 CB =162.81 BLD2022-0497 RESUB Cl, Jul 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Applicant shall repair/replace all APPROVED FOR CONSTRUCTION damage to utilities or frontage CITY OF EDMONDS improvements in City right-of-way per city standards that is caused or occurs during the permitted project. ENGINEERING DIVISION APPROVED AS NOTED DATE: Jd] 07/26/2022 BY. CALL 48 HOURS THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL CITY ENGINEERING DIVISION BEFORE YOU DIG UTILITIES PRIOR TO ANY CONSTRUCTION. AGENCIES INVOLVED 1-800-424-5555 SHALL BE NOTIFIED WITHIN A REASONABLE TIME PRIOR TO THE START OF CONSTRUCTION. DATE REVISION/ISSUED PFN: BLD20181267 PROJECT NO. 09114118 ISSUED 0611JI19 REVISED PER CITY COMMENTS 180453 HICKSCHILDffN'S TRUST 02/07/22 AS BUILT 03/03122 REVISED PER CITY COMMENTS DWG 04128122 REVISED PER CITY COMMENTS (ADD IE) FULL DRAINAGE 07108122 ADDED DISPERSION TRENCH AS -BUILT & ADDITIONAL SEWER INFO C4 0711JI22 ADDED DISPERSION TRENCH AS -BUILT & ADDITIONAL SEWER INFO GRADINGIDRAINAGE PLAN OF 5 AS -BUILT DECLARATION WE HEREBY DECLARE THAT THE ROAD, STORM DRAINAGE, GRADING AND OTHER IMPROVEMENTS ARE LOCATED AS SHOWN ON THESE RECORD DRAWINGS AND THAT THESE RECORD DRAWINGS ARE SUBMITTED ON A TRUE COPY OF THE APPROVED CONSTRUCTION PLANS 0 711 J122 ECT ENGINEER/SURVEY DATE DATE: 02107122 SEE APPLICABLE STANDARD DETAILS FRAME AND GRATE RISER SECTION Itv PIPE ALLOWANCES PIPE MATERIAL MAXIMUM INSIDE DIAMETER REINFORCED OR 12" PLAIN CONCRETE ALL METAL PIPE 15" CPSSP* 12" (WSDOT STD SPEC 9-05.20) SOLID WALL PVC 15" (WSDOT STD SPEC 9-05.12.(1)) PROFILE WALL PVC 15" (WSDOT STD SPEC 9-05.12(2)) * CORRUGATED POLYETHYLENE STORM SEWER PIPE 2". 4". 6". OR 12" NOTES: 1. CATCH BASINS SHALL BE CONSTRUCTED IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 9-05.50(3). 2. AS AN ACCEPTABLE ALTERNATIVE TO REBAR, WELDED WIRE FABRIC HAVING A MIN. AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. WELDED WIRE FABRIC SHALL COMPLY TO ASTM A497 (AASHTO M 221). WIRE FABRIC SHALL NOT BE PLACED IN KNOCKOUTS. 4� 3. APPLY NON -SHRINK GROUT TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS AND FRAMES. 4. ROUND KNOCKOUTS MAY BE ON ALL 4 SIDES, WITH MAX DIAMETER OF 20". KNOCKOUTS MAY BE EITHER ROUND OR "D" SHAPE. 5. THE MAX DEPTH FROM THE FINISHED GRADE TO THE PIPE INVERT IS 5'-0". 6. THE TAPER ON THE SIDES OF THE PRECAST BASE SECTION AND RISER SECTION SHALL NOT EXCEED 1/2"/FT. 7.CATCH BASIN FRAME AND GRATE SHALL BE IN ACCORDANCE WITH STANDARD SPECIFICATIONS. MATING SURFACES SHALL BE FINISHED TO ASSURE NON -ROCKING FIT WITH ANY COVER POSITION. (MEASUREMENT AT THE TOP OF THE BASE) 8.VERTICAL EDGE OF RISER SHALL NOT BE MORE THAN 2" PRECAST BASE SECTION FROM VERTICAL EDGE OF CATCH BASIN WALL. CITY OF EDMONDS PUBLIC WORKS DEPARTMENT CATCH BASIN TYPE APPROVED BY: R. ENGLISH REVISION DATE JANUARY 2018 STANDARD DETAIL SD-303 14' EX. GROUND --------------- - - - - -------___ - 4" CEMENT CONCRETE - 2 - 5/8" MINUS CSTC COMPACTED SUBGRADE 6" COMPACTED SUB -BASE OR NATIVE MATERIAL SUB -GRADE COMPACTED TO 959 MAX. DENSITY (MODIFIED PROCTOR). CONCRETE DRIVEWAY SECTION YAA N. T. S. C1 RESIDENCE CLEANOUT a WITH 45' BEND AND 2' CAP - CLEANOUT (MAX) (TYP) TO EXCEED 106 BETWEEN CLEMOUTS CLEANOUT (WYE WITH CAP AND CLEANOUT COVER) AND CONCRETE LEVELING COLLAR 2"t r FINISHED GRADE w a 12" LOCKING COVER a 3 SEE NOTE 3 0 END OF PIPER GRIPPER PLUG F' EQUAL) (CHERNE 27081 OR APPROVED TK HT CAP45•ER L�WATER LEVELING COLLAR lSEE NOTE 4f/z'S 12' PVC SLEEVE � 8' RISER 4" OR 8SIDE SEWER 6" WYE AND r 6" CITY Sf J� GFNIIE CLEANOUT DETAIL as BEND 4" OR 6" 12' LOCKING COVER SIDE SEWER CLEANOUT DETAIL SEE NOTE 3 AT PROPERTY LINE/CITY EASEMENT La m LEVELING COLLAR NOTES. 2 a W SEE NOTE 4 ASPHALT SURFACE 1. SEWER PIPE SHALL BE 5OR-35 AND JOINTS SHALL BE GASKETED. NOR '' '• 12"* 2. PIPE SLOPE TO BE 2X MIN AND JP TO 507E MAX. 3. SEWER CLEANOUT COVER TO BE EAST JORDAN IRON WORKS 1 FOOT LONG 12' PVC PRODUCT #00366102 STAR PIPE COSP48L OR APPROVED SLEEVE EQUAL. 8' RISER END OF PIPE GRIPPER 4. LEVELING COLLAR SHALL BE CONSTRUCTED AS FOLLOWS: PLUG (CHERNE 270261 OR APPROVED EQUAL) IN ROADWAYS PER COE STD DWG GU-424 TYPICAL CLEANOUT IN SIDEWALI(/LANDSCAPED AREAS, EITHER 24'x24"xr" DEEP CONCRETE COLLAR OR 24' DIAMETER x 6' DEEP UNDER ASPHALT OR CONCRETE CONCRETE COLLAR y� REVISION DATE CITY OF EDMONDS JANUARY 2018 SEWER CLEANOUT DETAILS PUBLIC WORKS STANDARD DEPARTMENT DETAI L APPPOvEC. er R. ENGLISH SS-200 SUPPORT POSTS END CAP OR PLUG CLEANOUT (TYP) PERFORATED PVC �0 UNDERDRAIN PIPE FLOW TO OTHER 0 DISPERSION TRENCH(ES) IF NECESSARY O TYPE 1 OR 1-L CATCH 0 000 TYPE 1 OR BASIN W/SOLID COVER S 1-L CATCH PER STD DETAIL BASIN W/SOLID SD-303 OR SD-304 COVER PER STD DETAIL -^ El SD-303 OR SD-304 A � TY)c ,0 .o 000 PIPE FROM 0 ROOF DOWNSPOUT NOTCHED GRADE BOARD, 2"x2" 10' (MIN) 00 400 NOTCHES, 18' O.C. PLAN NTS I� �2» (TYP) 2" GRADE BOARD L18" O.0 - NOTCHES (TYP) NOTCH DETAIL 2% 12" PRESSURE TREATED GRADE BOARD VEGETATED FLOW PATH, *15% MAX FOR FLOW CONTROL/WATER SEE NOTE 1 QUALITY TREATMENT IN RURAL AREAS. PX 20%MAX GALVANIZED o�oO BOLT (TYP) I p00� Z x JD�F oN Jp (D ��n WASHED DRAIN ROCK, SEE NOTE 3 O 4" (MIN) PERFORATED PVC UNDERDRAIN PIPE 6" (MIN) PER WSDOT SPEC. 9-05.2(6), LAID LEVEL GEOTEXTILE, SEE NOTE 2 4"x4" PRESSURE UNDISTURBED TREATED SUPPORT POST NATIVE SOIL SECTION A NTS - `St. 18y- CITY OF EDMONDS PUBLIC WORKS DEPARTMENT FINISH GRADE 0 z 0 m GENERAL NOTES: 1. REFER TO THE 2017 CITY OF EDMONDS STORMWATER ADDENDUM FOR SETBACK AND INFEASIBILITY REQUIREMENTS. NOTES: 1. A VEGETATED FLOW PATH MUST BE PROVIDED IN ACCORDANCE THE 2017 CITY OF EDMONDS STORMWATER ADDENDUM REQUIREMENTS. 2. GEOTEXTILE SHALL CONFORM TO WSDOT SPEC. 9-33.2(1) GEOTEXTILE FOR SEPARATION, NON -WOVEN TYPE. 3. WASHED DRAIN ROCK SHALL CONFORM TO WSDOT SPEC. 9-03.12(5), GRAVEL BACKFILL FOR DRYWELLS. TYPICAL DISPERSION TRENCH WITH NOTCHED GRADE BOARD APPROVED BY: R. ENGLISH EX GROUND ---------- - LANDSCAPE WALL PER COE SIDS (TYP) PVC SIDE NOTE: NO DRAINAGE WAS INSTALLED BEHIND LANDSCAPE WALLS 5' 3' . 2' REVISION DATE DECEMBER 2017 STANDARD DETAIL SD-632 I j\ EX ROCK WALL EL=145.4f (t 1.5' HI) I EL=143.9 CO RE=143.9 IE=141.59 (EX) AB SIDE SEWER SERVICE SECTION g N. T. S. Cl AB DATE REVISION/ISSUED 09114118 ISSUED )wc Ll c 0611JI19 REVISED PER CITY COMMENTS 02107122 AS -BUILT 04128122 REVISED PER CITY COMMENTS (ADD IE) 07108122 ADDED DISPERSION TRENCH AS -BUILT & ADDITIONAL SEWER INFO P . 0. BOX 1 77, S I L VA N A , WA 98287 07113/22 ADDED DISPERSION TRENCH AS -BUILT & ADDITIONAL SEWER INFO CALL 48 HOURS THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL TEE: (360) 652- 5820 BEFORE YOU DIG UTILITIES PRIOR TO ANY CONSTRUCTION. AGENCIES INVOLVED EMAIL: m o c e n i n e e r i n (gfr o n tier. c o m 1-800-424-5555 SHALL BE NOTIFIED WITHIN A REASONABLE TIME PRIOR TO g g THE START OF CONSTRUCTION. DATE BY.• PFN: BLD20181267 RESUB Jul 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT APPROVED FOR CONSTRUCTION CITY OF EDMONDS CITY ENGINEERING DIVISION HICKS CHILDffN'S TRUST FULL DRAINAGE DETAILS PROJECT NO. 180453 DWG cs OF 5 D� toot otg.n 41 i 1 Ell R�,y ') ;Z E i`Q$.7) Jed �@ 5 �' .. sL % 1i17� ,Q of LIM ��YrGO RECEIVED Apr 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT nr 1