Loading...
APPROVED PLN, ENG, BLD2019-1386 REVISION- PED WALKWAY PARKING LOTI ❑ Q U w U U Q O J Z ❑ Y Z ry O Q U d Z U Y ❑ Q z W O U O ry d O v ❑ io ry Lp ry N O 09 o Z N O o Z PROJECT LOCATION r SouNDTRANSIT CENTRAL PUGET SOUND REGIONAL TRANSIT AUTHORITY LOCATION MAP NTS INDEX OF DRAWINGS SHT NO. DWG NO. TITLE 1 578-GZT001 LOCATION MAP, VICINITY MAP AND INDEX OF DRAWINGS 2 578-GZN001 GENERAL NOTES 3 578-CMP001 PARKING LOT MODIFICATIONS PLAN c PROJECT LOCATION VICINITY MAP SCALE: 1 " = 1000' SOUNDER COMMUTER RAIL EDMONDS STATION SM01 12 PARKING LOT ACCESS 100% SUBMITTAL JUNE 5, 2020 PREPARED BY: SUBMITTED BY: NAME: JACKLYN UNIZA TITLE: ASSOCIATE ENGINEER APPROVED BY: NAME:MARTIN LU TITLE: DESIGN MANAGER DATE: DATE: m D1 1 1 GENERAL NOTES C� 0 0 0 z N c3 00 rl- LO N 0 U) w w 0 Q 0 U) w 0 U Q O J Z Y Q U) 0 Z O 2 0 0 w Z O N Zo Qcf) �o Of a 0 � tY N O o 0 N Z o O o 1. REFERENCE TO CODES, RULES, REGULATIONS, STANDARDS, MANUFACTURER'S INSTRUCTIONS OR REQUIREMENTS OF REGULATORY AGENCIES IS TO THE LATEST PRINTED EDITION OF EACH IN EFFECT AT THE DATE OF SUBMISSION OF BID UNLESS THE DOCUMENT DATE IS SHOWN. 2. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND FOR VERIFYING ALL DIMENSIONS BEFORE CONSTRUCTION. NOTIFY THE ENGINEER OF ANY DISCREPANCIES AND RESOLVE BEFORE PROCEEDING WITH THE WORK. DIMENSIONS: 1. ALL PLAN DIMENSIONS ARE MEASURED IN A TRUE HORIZONTAL PLANE. 2. ALL VERTICAL DIMENSIONS ARE MEASURED IN A TRUE VERTICAL PLANE. 3. ALL DIMENSIONS, LOCATIONS, AND ELEVATIONS OF EXISTING STRUCTURES SHOWN ON THE CONTRACT DRAWINGS ARE FOR REFERENCE ONLY AND SHALL BE VERIFIED BY THE CONTRACTOR IN THE FIELD. 3. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR PROVIDING A SAFE PLACE TO WORK AND MEETING THE REQUIREMENTS OF ALL APPLICABLE JURISDICTIONS. EXECUTE 4. ANY DISCREPANCIES BETWEEN THE DRAWINGS SHALL BE REFERRED TO THE RESIDENT WORK TO ENSURE THE SAFETY OF PERSONS AND ADJACENT PROPERTY AGAINST ENGINEER FOR CLARIFICATION PRIOR TO UNDERTAKING THE WORK. DAMAGE BY FALLING DEBRIS AND OTHER HAZARDS IN CONNECTION WITH THIS WORK. 4. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, USE SIMILAR DETAILS OF CONSTRUCTION, SUBJECT TO REVIEW BY THE ENGINEER. 5. THE DRAWINGS INDICATE THE STRUCTURE IN ITS FINAL CONDITION. THE CONTRACTOR SHALL PROVIDE MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES INCLUDE, BUT MAY NOT BE LIMITED TO, BRACING, SHORING, AND SEQUENCING TO MAINTAIN STABILITY DURING CONSTRUCTION. RETAIN A REGISTERED CIVIL ENGINEER WHOM IS PROPERLY QUALIFIED TO DESIGN BRACING, SHORING, ETC. VISITS TO THE SITE BY THE ENGINEER WILL NOT INCLUDE OBSERVATION OF THE ABOVE NOTED ITEMS. 6. THIS WORK OCCURS AT AN EXISTING FACILITY. INFORMATION SHOWN ON THE DRAWINGS RELATED TO EXISTING CONDITIONS REPRESENTS THE PRESENT KNOWLEDGE, BUT IS WITHOUT GUARANTEE OF ACCURACY. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS AND REPORT CONFLICTS WITH THE CONTRACT DOCUMENTS TO THE OWNER'S REPRESENTATIVE PRIOR TO FABRICATION OR ERECTION/INSTALLTION. DO NOT DEVIATE FROM THE CONTRACT DOCUMENTS WITHOUT WRITTEN DIRECTION FROM THE ENGINEER. 7. SHOP DRAWINGS, AS REQUIRED BY THE SPECIFICATIONS, SHALL BE SUBMITTED AND SHALL HAVE RECEIVED ACCEPTANCE BY THE ENGINEER PRIOR TO FABRICATION OR ERECTION/INSTALLATION. 8. THE CONTRACTOR SHALL VERIFY THE FINAL LOCATION OF ALL EQUIPMENT, AND SUPPORTS PRIOR TO FABRICATION. IDENTIFICATION OF EXISTING UTILITIES THAT INTERFERE WITH EQUIPMENT INSTALLATION IS ALSO THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IF FIELD CONDITIONS RESTRICT THE INSTALLATION OF COMPONENTS OR RESTRAINTS SHOWN ON THE CONSTRUCTION DOCUMENTS. 9. THIS WORK OCCURS WITHIN/NEAR AN OPERATING FACILITY. COORDINATE ALL CONSTRUCTION ACCESS AND OPERATIONS TO AVOID DISRUPTION TO ONGOING FACILITY OPERATIONS. 10. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS WITHIN PROJECT LIMITS AND ALERT THE ENGINEER IF DIMENSIONS DIFFER FROM THOSE USED IN THE PLANS. EXISTING CONDITIONS: 1. ALL WORKS SHALL BE UNDERTAKEN IN ACCORDANCE WITH THE LATEST EDITION OF THE CURRENT DESIGN DOCUMENTS. 2. CONTRACTOR SHALL VERIFY ALL LEVELS, DIMENSIONS, AND EXISTING CONDITIONS IN THE FIELD BEFORE PROCEEDING. CONTRACTOR SHALL NOTIFY THE RESIDENT ENGINEER OF ANY DISCREPANCIES OR FIELD CHANGES PRIOR TO INSTALLATION OR FABRICATION. IN CASE OF DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND THE DRAWINGS, THE CONTRACTOR SHALL OBTAIN DIRECTION FROM THE RESIDENT ENGINEER BEFORE PROCEEDING. DIMENSIONS NOTED AS PLUS OR MINUS ± INDICATE UNVERIFIED DIMENSIONS AND ARE APPROXIMATE. NOTIFY RESIDENT ENGINEER IMMEDIATELY OF CONFLICTS OR EXCESSIVE VARIATIONS FROM INDICATED DIMENSIONS. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS - DO NOT SCALE DRAWINGS. DIMENSIONS OF EXISTING CONDITIONS MAY BE BASED ON RECORD DRAWINGS AND ARE TO BE FIELD VERIFIED BY THE CONTRACTOR. SUBMITTALS: 1. SUBMITTALS: SHOP DRAWINGS BEARING CONTRACTOR'S REVIEW STAMP SHALL BE SUBMITTED TO THE RESIDENT ENGINEER AND APPROVED PRIOR TO ANY FABRICATION OR CONSTRUCTION FOR ALL STRUCTURAL ITEMS, INCLUDING THE FOLLOWING: CONCRETE OR MASONRY REINFORCEMENT, PRECAST OR PRESTRESSED CONCRETE ITEMS, EMBEDDED STEEL ITEMS, STRUCTURAL STEEL, STEEL DECK, SHEAR STUD LAYOUT, METAL GRATING AND STAIRS. IF THE SHOP DRAWINGS DIFFER FROM OR ADD TO THE DESIGN OF THE STRUCTURAL DRAWINGS, THEY SHALL BEAR THE SEAL AND SIGNATURE OF THE WASHINGTON STATE REGISTERED PROFESSIONAL ENGINEER WHO IS RESPONSIBLE FOR THE DESIGN. CONCRETE REINFORCING CONCRETE MIX DESIGN CAST -IN -PLACE CONCRETE: 1. CAST -IN -PLACE CEMENT CONCRETE SHALL BE CONSTRUCTED WITH AIR -ENTRAINED CONCRETE CLASS 3000 CONFORMING TO THE REQUIREMENTS OF SECTION 6-02 OF THE WSDOT STANDARD SPECIFICATIONS AND CITY OF EDMONDS TR-531 STANDARD DETAIL. DESIGN CODES AND STANDARDS: SIGNAGE 1. "SOUND TRANSIT DESIGN CRITERIA MANUAL" JUNE 2018, REVISION 5 (DCM). 1. CONTRACTOR TO INSTALL SOUND TRANSIT PROVIDED SIGNAGE. 2. SEATTLE BUILDING CODE (SBC), 2015 EDITION. 2. SIGNS SHALL BE PLACED PER MUTCD STANDARDS. 3. INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION WITH WASHINGTON STATE AND CITY OF EDMONDS AMENDMENTS. 3. ALL SIGNS SHALL BE PER CITY OF EDMONDS STANDARD DETAIL TR-571 FOR INSTALLATION IN NON SIDEWALK AREA, DETAIL TR-572 FOR INSTALLATION IN SIDEWALK 4. STANDARD SPECIFICATIONS AND STANDARD PLANS FOR ROAD, BRIDGE AND MUNICIPAL AREA AND DETAIL TR-575 FOR TRAFFIC STREET SIGNS. CONSTRUCTION, 2020 EDITION, WASHINGTON STATE DEPARTMENT OF TRANSPORTATION. TACTILE STRIP 5. CITY OF EDMONDS STANDARD DETAILS. 1. TACTILE DETECTABLE WARNING SURFACE TO MATCH EXISTING, REFER TO WSDOT STANDARD PLANS F-45.10-02. 6. 2018 SOUND TRANSIT STANDARD SPECIFICATIONS AMENDMENT 4. Digitally signed by E Egan E Egan Date: 020 6.10 16 03to 38-070 0' O=ST DESIGNED BY: SCALE: DRAWING No.: J.UNIZA P�oF3A sySF Q J NOT TO SCALE SOUNDER COMMUTER RAIL100%SUBMITTAL = 578-GZN001 DRAWN BY: a �`G �'�,� 9 U FILENAME: EDMONDS STATION B. PATTEN w ~ z z w J 02_578-GZN001 PARKING LOT ACCESS FACILITY ID: CHECKED BY: �� z LL CONTRACT No.: p� & R �� SOUNDTRANSIT GENERAL NOTES SHEET No.: 578 REV: B. HARRIS /STE RTA / LR XXXX-XX APPROVED BY: ASS/0NAL SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE: LDATE IDSN CHK APP REVISION M. LU 06/09/2020 4/26/2020 2 # O 0 0 0 p 75 U 00 I` coI 0 U) H W W 2 0 Q U U) w U Q O J z Y ry Q U) 0 z O 75 0 0 w zt o N Z 0 Q� �O ry 0 N O o U N Z o O z o 100% SUBMITTAL INo. I DATE I DSN I CHK J APP I REVISION DESIGNED BY: J. UNIZA DRAWN BY: B. PATTEN CHECKED BY: B. GOCHENOUR APPROVED BY: M. LU I I I I I I ® I I I I � I STRIPING ON BOTH SIDES OF CROSSWALK, SEE WSDOT STANDARD PLAN M-17.10-02 FOR 60 DEGREE PARKING ARRANGEMENT 24" WARNING SURFACES EMBEDDED IN CONC TO MATCH EXISTING i,--------------- I H--------------- LOADING DOCK FOR CROSS WALK DETAILS SEE CITY OF EDMONDS STANDARD DETAIL TR-562 — ATTACH SIGN TO (E) FENCE W/ TAMPER RESISTANT 2" CHAIN LINK FENCE SIGN MOUNTING BRACKETS (E) RAISED CURB 1 ATTACH SIGN TO (E) REMOVE (E) ASPHALT AND CMU WITH SIMPSON EXCAVATE TO FIRM TITEN HD. MIN 4" EMBED UNDISTURBED SOIL. PLACE 5" MIN CONC OVER 3/4" MINUS CRUSHED ROCK, 2% MAX SLOPE. 3 A M ,Z`Aq� ►Q P `� �F W q Sy��' F�' 1 So ',!1-77' /ONAL 06/09/2020 PARKING LOT MODIFICATIONS PLAN SCALE: 1" = 10' 10 5 0 10 20 SCALE IN FEET Digitally signed by E Egan E E g a n DIN C=US, DECM, rd e E Egan undtransit org O=ST, OU=DECM, CN=E Egan Date: 2020.06.10 16:04:28-07'00' SUBMITTED BY: DATE: REVIEWED BY: Q Q U Lo � W J J z " SOUNDTRANSIT DATE: SCALE: AS SHOWN FILENAME: 03_578-CMP001 CONTRACT No.: RTA / LR XXXX-XX DATE: 4/26/2020 G m ­0 FA �ppppllh ni,, Z wk7mp�app-a �C WATCHFOR MOVING TRUCKS TRUCK DANGER SIGN NTS NTS SOUNDER COMMUTER RAIL EDMONDS STATION PARKING LOT ACCESS PARKING LOT MODIFICATIONS PLAN 1 DRAWING No.: 1" RADIU TYP 0 t N 578-CMP001 FACILITY ID: 578 SHEET No.: REV: 3 #