REVISION- PED WALKWAY PARKING LOTI
❑
Q
U
w
U
U
Q
O
J
Z
❑ Y
Z ry
O Q
U d
Z U
Y ❑
Q Z
W
O
U
O
ry
d O
v ❑
io ry
Lp ry
N O
09
o Z
N O
O Z
PROJECT
LOCATION
r
SouNDTRANSIT
CENTRAL PUGET SOUND REGIONAL TRANSIT AUTHORITY
LOCATION MAP
NTS
INDEX OF DRAWINGS
SHT NO.
DWG NO.
TITLE
1
578-GZT001
LOCATION MAP, VICINITY MAP AND INDEX OF DRAWINGS
2
578-GZN001
GENERAL NOTES
3
578-CMP001
PARKING LOT MODIFICATIONS PLAN
c
PROJECT
LOCATION
VICINITY MAP
SCALE: 1 " = 1000'
SOUNDER COMMUTER RAIL
EDMONDS STATION
SM01 12
PARKING LOT ACCESS
100% SUBMITTAL
JUNE 5, 2020
PREPARED BY:
SUBMITTED BY:
NAME: JACKLYN UNIZA
TITLE: ASSOCIATE ENGINEER
APPROVED BY:
NAME:MARTIN LU
TITLE: DESIGN MANAGER
DATE:
DATE:
m ❑1 1 1
GENERAL NOTES
C�
0
0
0
z
N
(3
00
ti
LO
N
0
U)
w
w
0
Q
0
U)
w
0
U
Q
O
J
Z
Y
Q
U)
0
Z
O
2
0
0 w
Z
O N
Zo
Qcf)
�o
Of
a 0
� tY
N O
o 0
N Z
o O
o
1. REFERENCE TO CODES, RULES, REGULATIONS, STANDARDS, MANUFACTURER'S
INSTRUCTIONS OR REQUIREMENTS OF REGULATORY AGENCIES IS TO THE LATEST
PRINTED EDITION OF EACH IN EFFECT AT THE DATE OF SUBMISSION OF BID UNLESS THE
DOCUMENT DATE IS SHOWN.
2. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES
AND FOR VERIFYING ALL DIMENSIONS BEFORE CONSTRUCTION. NOTIFY THE ENGINEER
OF ANY DISCREPANCIES AND RESOLVE BEFORE PROCEEDING WITH THE WORK.
DIMENSIONS:
1. ALL PLAN DIMENSIONS ARE MEASURED IN A TRUE HORIZONTAL PLANE.
2. ALL VERTICAL DIMENSIONS ARE MEASURED IN A TRUE VERTICAL PLANE.
3. ALL DIMENSIONS, LOCATIONS, AND ELEVATIONS OF EXISTING STRUCTURES SHOWN ON
THE CONTRACT DRAWINGS ARE FOR REFERENCE ONLY AND SHALL BE VERIFIED BY THE
CONTRACTOR IN THE FIELD.
3. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR PROVIDING A SAFE PLACE TO WORK
AND MEETING THE REQUIREMENTS OF ALL APPLICABLE JURISDICTIONS. EXECUTE 4. ANY DISCREPANCIES BETWEEN THE DRAWINGS SHALL BE REFERRED TO THE RESIDENT
WORK TO ENSURE THE SAFETY OF PERSONS AND ADJACENT PROPERTY AGAINST ENGINEER FOR CLARIFICATION PRIOR TO UNDERTAKING THE WORK.
DAMAGE BY FALLING DEBRIS AND OTHER HAZARDS IN CONNECTION WITH THIS WORK.
4. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE
CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO
DETAILS SHOWN, USE SIMILAR DETAILS OF CONSTRUCTION, SUBJECT TO REVIEW BY
THE ENGINEER.
5. THE DRAWINGS INDICATE THE STRUCTURE IN ITS FINAL CONDITION. THE CONTRACTOR
SHALL PROVIDE MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING
CONSTRUCTION. SUCH MEASURES INCLUDE, BUT MAY NOT BE LIMITED TO, BRACING,
SHORING, AND SEQUENCING TO MAINTAIN STABILITY DURING CONSTRUCTION. RETAIN A
REGISTERED CIVIL ENGINEER WHOM IS PROPERLY QUALIFIED TO DESIGN BRACING,
SHORING, ETC. VISITS TO THE SITE BY THE ENGINEER WILL NOT INCLUDE OBSERVATION
OF THE ABOVE NOTED ITEMS.
6. THIS WORK OCCURS AT AN EXISTING FACILITY. INFORMATION SHOWN ON THE
DRAWINGS RELATED TO EXISTING CONDITIONS REPRESENTS THE PRESENT
KNOWLEDGE, BUT IS WITHOUT GUARANTEE OF ACCURACY. CONTRACTOR TO FIELD
VERIFY EXISTING CONDITIONS AND REPORT CONFLICTS WITH THE CONTRACT
DOCUMENTS TO THE OWNER'S REPRESENTATIVE PRIOR TO FABRICATION OR
ERECTION/INSTALLTION. DO NOT DEVIATE FROM THE CONTRACT DOCUMENTS WITHOUT
WRITTEN DIRECTION FROM THE ENGINEER.
7. SHOP DRAWINGS, AS REQUIRED BY THE SPECIFICATIONS, SHALL BE SUBMITTED AND
SHALL HAVE RECEIVED ACCEPTANCE BY THE ENGINEER PRIOR TO FABRICATION OR
ERECTION/INSTALLATION.
8. THE CONTRACTOR SHALL VERIFY THE FINAL LOCATION OF ALL EQUIPMENT, AND
SUPPORTS PRIOR TO FABRICATION. IDENTIFICATION OF EXISTING UTILITIES THAT
INTERFERE WITH EQUIPMENT INSTALLATION IS ALSO THE RESPONSIBILITY OF THE
CONTRACTOR. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IF FIELD CONDITIONS
RESTRICT THE INSTALLATION OF COMPONENTS OR RESTRAINTS SHOWN ON THE
CONSTRUCTION DOCUMENTS.
9. THIS WORK OCCURS WITHIN/NEAR AN OPERATING FACILITY. COORDINATE ALL
CONSTRUCTION ACCESS AND OPERATIONS TO AVOID DISRUPTION TO ONGOING
FACILITY OPERATIONS.
10. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS WITHIN PROJECT LIMITS AND
ALERT THE ENGINEER IF DIMENSIONS DIFFER FROM THOSE USED IN THE PLANS.
EXISTING CONDITIONS:
1. ALL WORKS SHALL BE UNDERTAKEN IN ACCORDANCE WITH THE LATEST EDITION OF THE
CURRENT DESIGN DOCUMENTS.
2. CONTRACTOR SHALL VERIFY ALL LEVELS, DIMENSIONS, AND EXISTING CONDITIONS IN
THE FIELD BEFORE PROCEEDING. CONTRACTOR SHALL NOTIFY THE RESIDENT
ENGINEER OF ANY DISCREPANCIES OR FIELD CHANGES PRIOR TO INSTALLATION OR
FABRICATION. IN CASE OF DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND
THE DRAWINGS, THE CONTRACTOR SHALL OBTAIN DIRECTION FROM THE RESIDENT
ENGINEER BEFORE PROCEEDING. DIMENSIONS NOTED AS PLUS OR MINUS ± INDICATE
UNVERIFIED DIMENSIONS AND ARE APPROXIMATE. NOTIFY RESIDENT ENGINEER
IMMEDIATELY OF CONFLICTS OR EXCESSIVE VARIATIONS FROM INDICATED DIMENSIONS.
NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS - DO NOT SCALE
DRAWINGS. DIMENSIONS OF EXISTING CONDITIONS MAY BE BASED ON RECORD
DRAWINGS AND ARE TO BE FIELD VERIFIED BY THE CONTRACTOR.
SUBMITTALS:
1. SUBMITTALS: SHOP DRAWINGS BEARING CONTRACTOR'S REVIEW STAMP SHALL BE
SUBMITTED TO THE RESIDENT ENGINEER AND APPROVED PRIOR TO ANY FABRICATION
OR CONSTRUCTION FOR ALL STRUCTURAL ITEMS, INCLUDING THE FOLLOWING:
CONCRETE OR MASONRY REINFORCEMENT, PRECAST OR PRESTRESSED CONCRETE
ITEMS, EMBEDDED STEEL ITEMS, STRUCTURAL STEEL, STEEL DECK, SHEAR STUD
LAYOUT, METAL GRATING AND STAIRS. IF THE SHOP DRAWINGS DIFFER FROM OR ADD
TO THE DESIGN OF THE STRUCTURAL DRAWINGS, THEY SHALL BEAR THE SEAL AND
SIGNATURE OF THE WASHINGTON STATE REGISTERED PROFESSIONAL ENGINEER WHO
IS RESPONSIBLE FOR THE DESIGN.
CONCRETE REINFORCING
CONCRETE MIX DESIGN
CAST -IN -PLACE CONCRETE:
1. CAST -IN -PLACE CEMENT CONCRETE SHALL BE CONSTRUCTED WITH AIR -ENTRAINED
CONCRETE CLASS 3000 CONFORMING TO THE REQUIREMENTS OF SECTION 6-02 OF THE
WSDOT STANDARD SPECIFICATIONS AND CITY OF EDMONDS TR-531 STANDARD DETAIL.
DESIGN CODES AND STANDARDS:
SIGNAGE
1. "SOUND TRANSIT DESIGN CRITERIA MANUAL" JUNE 2018, REVISION 5 (DCM).
1. CONTRACTOR TO INSTALL SOUND TRANSIT PROVIDED SIGNAGE.
2. SEATTLE BUILDING CODE (SBC), 2015 EDITION.
2. SIGNS SHALL BE PLACED PER MUTCD STANDARDS.
3. INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION WITH WASHINGTON STATE AND
CITY OF EDMONDS AMENDMENTS. 3. ALL SIGNS SHALL BE PER CITY OF EDMONDS STANDARD DETAIL TR-571 FOR
INSTALLATION IN NON SIDEWALK AREA, DETAIL TR-572 FOR INSTALLATION IN SIDEWALK
4. STANDARD SPECIFICATIONS AND STANDARD PLANS FOR ROAD, BRIDGE AND MUNICIPAL AREA AND DETAIL TR-575 FOR TRAFFIC STREET SIGNS.
CONSTRUCTION, 2020 EDITION, WASHINGTON STATE DEPARTMENT OF
TRANSPORTATION. TACTILE STRIP
5. CITY OF EDMONDS STANDARD DETAILS. 1. TACTILE DETECTABLE WARNING SURFACE TO MATCH EXISTING, REFER TO WSDOT
STANDARD PLANS F-45.10-02.
6. 2018 SOUND TRANSIT STANDARD SPECIFICATIONS AMENDMENT 4.
Digitally signed by E Egan
E Egan Date: 020 6.10 16 03to
38-070
0' O=ST
DESIGNED BY: SCALE: DRAWING No.:
J.UNIZA P�oF3A sySF Q J NOT TO SCALE SOUNDER COMMUTER RAIL100%SUBMITTAL = 578-GZN001
DRAWN BY: a �`G �'�,� 9 U FILENAME: EDMONDS STATION
B. PATTEN w ~ z z w J 02_578-GZN001 PARKING LOT ACCESS FACILITY ID:
CHECKED BY: �� z LL CONTRACT No.:
p� & R �� SOUNDTRANSIT GENERAL NOTES SHEET No.: 578 REV:
B. HARRIS /STE RTA / LR XXXX-XX
APPROVED BY: ASS/0NAL SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:
LDATE IDSN CHK APP REVISION M. LU 06/09/2020 4/26/2020 2 #
O
0
0
0
p
75
U
00
I`
coI
0
U)
H
W
W
2
0
Q
U
U)
w
U
Q
O
J
z
Y
ry
Q
U)
0
z
O
75
0
0 w
zt
O N
Z
0
Q�
�O
ry
0
N O
o U
N Z
o O
z
o
100% SUBMITTAL
INo. I DATE I DSN I CHK J APP I REVISION
DESIGNED BY:
J. UNIZA
DRAWN BY:
B. PATTEN
CHECKED BY:
B. GOCHENOUR
APPROVED BY:
M. LU
� I
STRIPING ON BOTH SIDES OF
CROSSWALK, SEE WSDOT
STANDARD PLAN M-17.10-02
FOR 60 DEGREE PARKING
ARRANGEMENT
24" WARNING SURFACES EMBEDDED
IN CONC TO MATCH EXISTING
i,---------------
I
H---------------
I
I
I
I
I
I
® I
I
I
I
� � I
} I (U
I
LOADING DOCK
FOR CROSS WALK DETAILS
SEE CITY OF EDMONDS
STANDARD DETAIL TR-562
— ATTACH SIGN TO (E) FENCE W/
TAMPER RESISTANT 2" CHAIN
LINK FENCE SIGN MOUNTING
BRACKETS
(E) RAISED CURB
1 ATTACH SIGN TO (E) REMOVE (E) ASPHALT AND
CMU WITH SIMPSON EXCAVATE TO FIRM
TITEN HD. MIN 4" EMBED UNDISTURBED SOIL. PLACE
5" MIN CONC OVER 3/4"
MINUS CRUSHED ROCK, 2%
MAX SLOPE.
3 A M ,Z`Aq�
►Q P `� �F W q Sy��' F�' 1
So
',!1-77'
/ONAL
06/09/2020
PARKING LOT MODIFICATIONS PLAN
SCALE: 1" = 10'
10 5 0 10 20
SCALE IN FEET
Digitally signed by E Egan
E E g a n DIN C=US, DECM, rd e E Egan undtransit org
O=ST, OU=DECM, CN=E Egan
Date: 2020.06.10 16:04:28-07'00'
SUBMITTED BY:
DATE:
REVIEWED BY:
Q Q
U
Lo �
W J
J
z " SOUNDTRANSIT
DATE:
SCALE:
AS SHOWN
FILENAME:
03_578-CMP001
CONTRACT No.:
RTA / LR XXXX-XX
DATE:
4/26/2020
G
m
0
FA �ppppllh
ni,, Z wk7mp�app-a
�C
WATCHFOR
MOVING TRUCKS
TRUCK DANGER SIGN
NTS
NTS
SOUNDER COMMUTER RAIL
EDMONDS STATION
PARKING LOT ACCESS
PARKING LOT MODIFICATIONS PLAN
1
DRAWING No.:
1" RADIU
TYP
0
t
N
578-CMP001
FACILITY ID:
578
SHEET No.: REV:
3 #