APPROVED REV 1 BLD Over Deck Plan.PERMIT SET 2 (2)GENERAL NOTES AREA CALCULATIONS GENERAL REQUIREMENTS ALL WORK SHALL COMPLY WITH THE 2015 EDITION OF THE INTERNATIONAL BUILDING CODE (STRUCTURAL DESIGN), INTERNATIONAL RESIDENTIAL CODE (ORDINANCE), MOST RECENT EDITION OF THE UNIFORM PLUMBING CODE, NON -HEATED AREAS SQUARE FOOTAGE INTERNATIONAL MECHANICAL CODE, NATIONAL ELECTRIC CODE, WASHINGTON STATE ENERGY CODE, ANY STATE AND LOCAL AMENDMENTS, AND ANY APPLICABLE LAND USE CODE. REPLACEMENT DECK 706 THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR DEVELOPING CONSTRUCTION DETAILS NECESSARY TO CONSTRUCT A WEATHER TIGHT, DURABLE BUILDING. ALL FLASHING, WEATHERPROOFING, ROOFING AND WATERPROOFING DETAILS AND CONSTRUCTION OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE ---- RESPONSIBILITY OF THE OWNER/BUILDER AND THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER REQUIREMENTS, BUILDING CODE REQUIREMENTS AND ACCEPTED INDUSTRY STANDARDS FOR PERFORMANCE. THE DESIGNER HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION SERVICES OR CONSTRUCTION OBSERVATION SERVICES FOR THIS PROJECT AND IS NOT LIABLE OR RESPONSIBLE FOR DETERMINING ADEQUACY OF CONSTRUCTION OF BUILDING ENVELOPE OR DETAILS. THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR INSPECTING AND VERIFYING THAT ALL FLASHING, WEATHERPROOFING, ROOFING AND WATERPROOFING DETAILS ARE BUILT CORRECTLY AND MEET OWNER/BUILDER'S APPROVAL BEFORE BEING - COVERED BY SUBSEQUENT CONSTRUCTION WORK. USE OF THESE PLANS BY ANYONE OTHER THAN THE _-- INTENDED OWNER/BUILDER IS NOT PERMITTED. ANY REDUNDANCY BETWEEN THESE NOTES AND S-SHEETS THE S-SHEETS SHALL SUPERSEDE. SITE WORK 1. BACKFILL FOUNDATION DRAIN AT PERIMETER OF BUILDING WITH COURSE GRANULAR FILL. (1 1/2-3/8 CLEAN WASHED ROCK WITH MIN. 12" WIDE BLANKET EXTENDING TO FINISHED GRADE.) PROTECT DRAIN TILE AND WATERPROOFING. 2. ROUGH GRADING SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. TRENCH TO ELEVATIONS BELOW FROST LINE FOR STORM DRAINS, WATER LINES, SEWERS, AND IRRIGATION SLEEVES. \ , 3. PROVIDE PERFORATED PLASTIC PIPE FOUNDATION DRAINS WHERE SHOWN IN DRAWINGS. CONNECT TO ROOF AND STORM WATER SYSTEM. IN JURISDICTIONS REQUIRING SEPARATE ROOF DRAIN LINES, PROVIDE TIGHT LINE CONNECTED TO ROOF DRAINS IN ADDITION TO PERFORATED DRAIN LINES. 4. ROCKERIES AND RETAINING WALLS SHALL BE DESIGNED BY A LICENSED ENGINEER AND INSTALLED PER DRAWING INDEX , APPLICABLE CODE. MECHANICAL 1. PLUMBING SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT, EXPERIENCED PLUMBER AND IN SHEET NO. DESCRIPTION ACCORDANCE WITH THE UNIFORM PLUMBING CODE AND LOCAL CODES. 2. HVAC SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED MECHANICAL CONTRACTOR IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, 2015 IRC, AND LOCAL CODES. PROVIDE DOCUMENTATION OF FURNACE A.F.U.E. DUCTWORK INSULATION SHALL CONFORM TO THE Al COVER SHEET, INDEX, GENERAL NOTES WASHINGTON STATE ENERGY CODE. WHEN INSTALLED IN GARAGE, HEATING UNITS SHALL BE PLACED SUCH A2 FLOOR PLAN AND ELEVATIONS THAT ALL PILOT LIGHTS, BURNERS, HEATING ELEMENTS, OR SWITCHES ARE LOCATED A MIN. OF 18" ABOVE THE GARAGE FLOOR. S1 STRUCTURAL NOTES/SCHEDULES S2 FOUNDATION PLAN/ FRAMING PLAN THERMAL AND MOISTURE 1. APPLY APPROPRIATE WATER REPELLENTS TO ANY MASONRY, CEMENT, PLASTER, OR STUCCO PER MANUFACTURER'S INSTRUCTIONS. FINISHES ALL DECK STRUCTRUAL MEMEBERS TO BE PRESSURE TREATED PER STRUCTRUAL PLANS. DECK SURFACE PER BUILDER SPECIFICATIONS. ELECTRICAL 831 SOMERSET LANE., EDMONDS., WA 98020 IF ELECTRICAL WORK IS DONE, SYSTEMS SHALL BE INSTALLED BY A COMPETENT AND EXPERIENCED ELECTRICAL CONTRACTOR IN ACCORDANCE WITH MOST CURENT STATE AND LOCAL ELECTRICAL CODE. ELECTRICAL SCHEMATICS PROVIDED IN THIS SET OF PLANS ARE FOR REFERENCE LAYOUT ONLY. MISCELLANEOUS 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. IN THE FIELD PRIOR TO PROCEEDING. 2. VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALL WITH MECHANICAL AND ELECTRICAL WORK. 3. EXTERIOR OPENINGS TO THE WEATHER SHALL BE FLASHED AND COUNTER -FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF. ROOF FLASHING PER R903. 4. GUARDRAILS TO BE A MIN. OF 36" ABOVE FINISH FLOOR. (R312) 5. OPEN GUARDRAILS TO HAVE INTERMEDIATE RAILS OR PICKETS PLACED SUCH THAT A SPHERE 4" IN DIAMETER CANNOT PASS THROUGH. SYMBOL LEGEND CARBON MONOXIDE DETECTOR OO INTERCONNECTED 110v BATTERY BACKUP w/ C.O. CAN BE COMBINED w/ S.D. O SMOKE DETECTOR S.D. INTERCONNECTED 110v w/ BATTERY BACKUP O EXHAUST FAN (VENT TO OUTSIDE) OKEYNOTE 101 DOOR SCHEDULE SYMBOL 1i WINDOW SCHEDULE SYMBOL Al REVISION- SEE DESCRIPTION IN TITLE BLOCK SIM DETAIL SYMBOL 1 SIMILAR DETAIL 101 — DETAIL NO. SHEET NO. IM �,S BUILDING CROSS SECTION Al DETAIL NO. SHEET NO. Room name — ROOM NAME REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION Eric REVISION BUILDING OFFICIAL Aug 13 2020 Aug 07 2020 APPROVED DATE , Know what's below. STATE LAW REQUIRES THAT YOU CALL BEFORE YOU DIG TO can before dig. LOCATE ALL UNDERGROUND UTILITIES. CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT you U Zc\1 00 �0 M Z Q� a �0 J W d m W N GS o �° J JL� U �co M (D `E .� Z cc)04 W N .F o aa) W m J p W a H E U C + C Q) ALA'' W N Z O N -O L p TO iZa 2 �Jm O ,°O Od a° .Uy. 'E 6°� D6 mo>¢ 0-u OyO ° °OUo6wcUo 0fOL ULLJ 0.oO EONNfE aZnoOo z LU O CD 00 01-1 W Q 0 z O LU 0 LU LUV Z z LU J o w � y UW LU w W O LU LU 0 O00 � N _o (B M c a� c o co •5: c E U m >° E a) � cm fl. 0 z PROJECT NO. 200508 DESIGNED BY TL DRAWN BY TL & RIM CHECKED BY TL SHEET NO. Al PRINT DATE 8/6/2020 4:03:19 PM ELEVATION NOTES PROVIDE METAL FLASHING OVER TOPS OF WINDOWS AND TOPS OF TRIMS DIRECTLY EXPOSED TO WEATHER. ROOFING MATERIAL, SIDING AND FLASHING SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS, INDUSTRY STANDARDS AND PER I.R.C. PORCHES, BALCONIES, RAMPS OR RAISED SURFACES LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 36" IN HEIGHT. OPEN SIDE OF STAIRS WITH A TOTAL RISE OF MORE THAN 30" SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT MEASURED VERTICALLY FROM THE NOSING OF THE TREADS. INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES SHALL BE SPACED SUCH THAT A 4" SPHERE CANNOT PASS THROUGH. THE TRIANGLE OPENINGS FORMED BY THE RISER, TREAD, AND BOTTOM OF RAIL SHALL BE SUCH THAT A 6" SPHERE CANNOT PASS THROUGH. EXTERIOR STAIRS SHALL BE NOT LESS THAN 36" WIDE. HANDRAILS SHALL NOT PROJECT MORE THAN 4.5" ON EITHER SIDE OF THE STAIRWAY AND MIN. CLEAR WIDTH AT OR BELOW THE HANDRAIL SHALL NOT BE LESS THAN 31.5". MAX. RISER HEIGHT IS 7 3/4". MIN. TREAD DEPTH SHALL BE 10". A LANDING IS REQUIRED AT TOP AND BOTTOM OF EACH STAIRWAY. SITE ADDRESS SHALL BE VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. NUMBERS SHALL CONTRAST WITH BACKGROUND, BE ARABIC NUMBERS OR ALPHABETICAL LETTERS, BE A MIN. OF 4" IN HEIGHT WITH A MIN. STROKE WIDTH OF 1/2". (R319.1) � MAIN FLOOR o'-o-oil REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION jk MAIN FL( of -oil TEMP. GLASS PANELS AT SECTIONS INDICATED OR PER OWNER SPECIFICATIONS. WFCT FI FVATir)M r4) EAST E LEVATI O N III III III III III III III III III III III III III III III III III III III III III III III III II NOR TH ELEVATION 1/4" = 1'-011 MAIN FLOOR AC 0'-0" 2' 0 0 0 W 2 z co zo 0' 2' 4' 8' HANDRAIL, GUARD AND BALUSTERS TO CONFORM TO R311.7.8. OPENINGS SPACED SUCH THAT A 4" SPHERE CANNOT PASS THROUGH. TREX OR EQUIV. TREADS CV z w 10" MIN. TREAD o � CNI �� II 16' MAIN FLOOR 1/4" = 1'-011 RESIDENTIAL STAIRS TO BE MIN. 36" (CLR) WIDE. 1 1/4" DIA. MIN- 2" DIA. MAX. HANDRAIL w/ RETURNS TO WALL. --- P.T. DBL. JOIST OR BEAM PER PLAN. TREX OR EQUIV. SPACED DECKING PER / BUILDER SPECS. II II \ II II - PRESSURE TREATED STRINGERS PER PLAN �� II TREX OR EQUIV. RISER 3/4" MIN- MATERIAL PER BUILDER 1 1/4" MAX. SPECS. NOSING TYP, STAIR DETAIL 3/4" = 1'-011 44 POST @ 4' O.C. ATTACHED TO RIM AND BLOCKING SO AS TO COUNTER A P.T. JOISTS PER PLAN. 200# FORCE - 2X6 RADIUS CAP OR EQUIV. 1x4 TRIM 2x2 PICKETS @ 5.5" O.C. 0 M 1x4 TRIM - SIMPSON SPACED DECKING LUS210z JOIST PER PLAN - - (2) 3/8" DIA. HANGER P.T. BLOCK THRU BOLT INTO RIM AND BLOCK. - SIMPSON A35z INSTALL A35Z EACH SIDE OF CLIP AT EACH STRINGERS 1 BLOCK TO JOIST P.T. JOISTS PER PLAN - P.T. RIM P.T. BLOCK AT - EACH RAIL POST \ -- P.T. BEAM PER PLAN REVISION Aug 07 2020 THRU DECK POST DETAIL CITY MONDS DEVELOPMENT SERVICES � DEPARTMENT RTT MENT 3/4" = 1'-011 U z 04 00 o 0) rn z a E a �0 Y= rn Wa•�, lu�j�a "� O J, U �m� M CO z 20c*4` W o W m 0 W a F E O + •Y+ .r ��:lii a�sh�: O tr+ _ ALA'' W Z y 4,6 C L y d N C C 0 C O O J 's C O T y N a o Z J p C N d m C y 22a ccm�~���0 n�-�a`� O J y 0) C 0 0- @ t6 O (0 N O .t.. U 0 C N O L Z 10 C E N O QV62 _ O W U£ O U Co U EO p C C 3 -N N O UJ J- y U a00 0.0 •- -0 y O H C {p y O. (6 H LLJ Z ao � m oIS E d Z LU O N O 00 01-1 W Q 0 z O � LU 0 LU LUV Z z LU J W h cn U LU w w w O LU LU in > M O 00 c6 0 N M c Y c In c o mn `o cr (D c E Y U N -0 m > E o � CO a 0 Z PROJECT NO. 200508 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A2 PRINT DATE 8/6/2020 4:02:42 PM GENERAL NOTES WOOD All design and construction shall conform to the requirements of the International Building Code SAWN LUMBER: Structural sawn lumber shall be kiln dried and be of the species and grade noted DECK BEAM PER PLAN 2015 Edition. below or better: Use Grade Fb(psi) Contractor shall verify all levels, dimensions and existing conditions in field before proceeding with Wall Studs Stud 675 LAP JOIST OVER any construction or demolition. Contractor shall notify the Architect of any discrepancies or field Plates & Planks Hem Fir #2 850 BEARING MIN. 6" AND \X\ changes Joists & Rafters Hem Fir #2 850 NAIL WITH (3) 10d HANGERS PER PLAN TYP 4x Beams Douglas Fir -Larch #2 900 VERIFY Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or 6x Beams Douglas Fir -Larch #2 875 EXISTING 2x . ' procedures required to perform the work. Contractor shall provide adequate shoring and bracing of Posts Douglas Fir -Larch #2 750 RIM JOIST 45' all structural members, existing construction and soil excavations as required, in a manner suitable 2x4 T&G Decking Douglas Fir -Larch Select 1750 to the work sequence. Temporary shoring and bracing shall not be removed until all final connections have been completed in accordance with the drawings and materials have achieved All lumber and plywood in contact with concrete, stucco, masonry or other cementitious materials I �, design strength. Foundations walls greater than 4 feet shall not be backfilled until the floor framing shall be treated with an E.P.A. acceptable wood preservative, such as Alkaline -Copper -Quaternary and all connections to the floor framing per these details are complete. "ACQ" or Copper Azole "CBA" type A and B. VERIFY FLOOR JOISTS PER PLAN EXISTING SILL CHANGES: No changes to these structural drawings are permitted without written consent of the All wood connectors shall be manufactured by Simpson Strong Tie Company (or approved equal), PLATE Engineer. Changes will be billed to the client, owner or contractor at the Engineer's hourly rate. and of the size and type shown on the drawings. All wood connectors in contact with 2x CONT. BLOCKING I BEAM PER PLAN preservative -treated wood shall be Triple Zinc G-185 galvanized (1.85 oz/sq ft coating). OVER BEAM DTT1Z WITH SDS25312 EACH DESIGN LOADS END OF DECK AND AT 64" o.c. EXISTING FLOOR PT 2x4 BRACE WITH (3) MINIMUM WOOD NAILING REQUIREMENTS: Unless otherwise noted on the drawings, typical wood LIVE LOADS: Live loads are determined in accordance with ASCE Ch. 7 POST PER PLAN WITH CAP o TO SILL PLATE FRAMING SDS25312 TOP AND framing shall be fastened as follows. See IBC Table 2304.10.1 for fastener alternatives not shown. L = 60 PSF (Balcony) (OR GUSSET PLATE) AND BOTTOM (1 FACE AT END DECK POST PER PLAN Location Min. Nail Quantity/Spacing Type* SNOW LOADS: Snow loads are determined in accordance with ASCE Ch. 7 with the following BASE PER POST SCHEDULE EXISTING POSTS) Factors: Beams (built up 2x's) 3" x 0.131" 24" o.c. T&B* FIN#3 TIE FOUNDATION Ground Snow Load Pg = 20 psf Ct = 1.0 Ce = 1.0 EF* staggered Roof Snow Load Ps = 25 psf Is = 1.0 Blocking -to joists, rafters, trusses 3" x 0.131" 2 each end TN POST BASE PER SCHEDULE or studs -to top plates 3" x 0.131" 3 TN FOUNDATIONS CIRCULAR FOOTING PER 0 0 PLAN Bottom plate -to joist, rim joist 3" x 0.131" 12" o.c. FIN (4) #4 VERT. WITH Concrete foundations shall bear on stiff, competent, undisturbed native soil. Prior to construction, or blocking 12" HOOK AT BASE the contractor shall obtain confirmation from the Building Official that the native soil at this project -to studs 3" x 0.131" 3 EN is adequate to support the following bearing pressure: Header (built up 2x's) 16d box 12" o.c. T&B FN / / - / / ////// DECK TO HOUSE 2 BRACE DETAIL 3 Allowable bearing pressure used for structural design = 2000 psf (assumed) Header -to studs 3" x 0.131" 4 TN Joist -to supports 3" x 0.131" 3 TIN o � FOOTING PER Where footings must bear on structural fill due to inadequate soil conditions, the fill shall be mixed -to rim joist 3" x 0.131" 4 EN LL = PLAN and compacted in accordance with specifications provided by a Geotechnical Engineer licensed in Rafter -to supports 3" x 0.131" 4 TN, EN z w the State of Washington. Rim Joist -to sill or blocking 3" x 0.131" 6" o.c. TN in - C� Stud -to Stud 3" x 0.131" 12" o.c. FIN 00M Bottom of footing elevation shall be located at minimum frost depth 18" below top of finished grade -to top/bottom plate 3" x 0.131" 4 TN unless required otherwise by the Building Official. The contractor shall confirm the minimum frost Top plate -to top plate 3" x 0.131" 12" o.c. FIN depth with the Building Official prior to excavation. -to studs 3" x 0.131" 3 EN -laps at corners and 3" x 0.131" 3 FIN CONCRETE intersections Concrete work shall comply, in general, with ACI 301 (latest edition) "Specifications for Structural Truss to top plate 3" x 0.131" 4 TN 2 %" CLR. Concrete for Buildings." *EN = end nail, FIN = face nail, TN = toe nail, EF = "each face", T&B = "top and bottom" CONCRETE MIXES: Concrete mixes shall conform ACI 318 Ch. 5. Minimum concrete strength f'c at 28 days shall be as follows: Slab -on -grade, Curbs and Pads - 2000 psi Footings - 2500 psi Walls, Stems - 3000 psi (2500 psi used for structural design) Water/cement ratio shall be measured by weight and shall be based on the total cementitious material. Water/cement ratio shall be determined by the supplier based on strength requirements TYPICAL DETAILS and shall not exceed 0.55. Water -reducing admixtures may be incorporated in concrete mix designs In addition to the details and schedules on the framing plans, those noted as "Typical" shall be but shall conform to ASTM C 464, and be used in accordance with the manufacturer's used throughout the structure as applicable. recommendations. CaCI and other water-soluable chloride admixtures shall not be used. REINFORCING STEEL: All reinforcing shall be deformed bar (rebar) with bar diameters specified in these drawings and properties below: All reinforcing unless noted otherwise - ASTM A615, Grade 60 #3 stirrups and ties - ASTM A615, Grade 40 Welded rebar - ASTM A706, Grade 60 Galvanized Welded Wire Fabric - ASTM A165 Reinforcing steel shall be detailed in accordance with ACI 315 "Manual of Standard Practice for Detailing Reinforced Concrete Structures." TYPICAL DECK SECTION 4 5 6 Reinforcing steel shall be lapped as noted on the drawings. Where lap length is not shown, reinforcing bars shall be lapped as follows: #5 and smaller - 48 bar diameters #6 and larger - 60 bar diameters Minimum concrete cover over reinforcing shall be as follows: Nonstructural Slab -on -grade - Mid -Depth Wall Bars: interior face - 3/4" exposed to earth/weather - 1-1/2" (#5 and smaller) 2" (#6 and larger) Footings: Bottom Bars - 3" (cast against earth) Top Bars - 1-1/2" Side Bars - 2" Provide supports as required for proper alignment and concrete cover around the reinforcement. Consult the CRSI Manual of Standard Practice MSP-1 for specific information. 7 8 9 REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION Eri& BUILDING OFFICIAL Aug 13 2020 APPROVED DATE REVISION Aug 07 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT STRUCTURAL NOTES 10, 11 12 Ross Engineering Design Inc JOB # 20039 rya n. ross@rossengineer.com 8/20/2020 y P� N. DE WAS,yi,� S 0 20 39 46411 ssG/STERN 0NM_ ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN N Uw a°'i d� o =-° m-6 y ° a o O L ?UE��zm 0m a =1.wf E T °- � y NC 0 O k C C U N E U y C C Z O C>Z 2 U a p O J N N C N O O@@@ O O N 2 _y 3 E U m Y N `. @ O `n L N U C E N d LUQ p W'L -io 3 m o m= 3 c d w UJO O U_:..0 N— LU F a O 'O N J F -Oa d o t aEi m 2> E m J Q O F O LJIIIIIIIJ O CN O 00 (>1 LJIIIIIIIJ Q Z `O CL LU p V Lu LJIIIIIIIJ Z ad W Z 0 � LLJ �he WIm w OL LIu LU 0 O 00 0 0 AL L Q N d f� 6 Z FILE/ NO. DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: S1 PRINT DATE 8 / 06 / 2020 el U O O POST, CAP & BASE SCHEDULE SYM. POST CAP BASE NOTES: P—Ol P.T. 4x4 ' SIMPSON PC44 PBS44 ' OPTION: 2x4 xl2" CLEAT EA. SIDE NAILED w/ (2) ROWS OF 10d @3"O.C. NOTE: SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE HANGER SCHEDULE SYM. HANGER H-01 LU28 / LUC28 H-02 LS70 H-03 HUC28-2 NOTE: HANGERS NOT CALLED OUT IN ROOF PLAN SHALL BE PROVIDED BY TRUSS ENGINEER NOTE ! ALL DECK FRAMING MEMBERS TO BE P.T. 2x8 JOISTS @ 16" O.C. (U.N.O.) LEGEND FLOOR PERIMETER LANDING JOISTS HEADERS & BEAMS STAIR STRINGERS CONCRETE UNDER EXISTING DECK FRAMING SCALE: 1/4" = 1'-0" BEAM SCHEDULE SYM. I BEAM BM-01 P.T.4x10 HF#2 0 O O LEGEND OCONCRETE EXISTING EXISTING FOOTING CONCRETE FOOTING SCHEDULE SYM. FOOTING SIZE RE -BAR PLACEMENT F-01 18" DIA. SEE 4/S1 F-02 20" DIA. SEE 4/S1 NOTE: SHALL BE MIN. 18" BELOW GRADE AND REST ON BEARING SOIL. FOUNDATION PLAN SCALE: 1/4" = 1'-0" REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION Eric BUILDING OFFICIAL Aug 13 2020 APPROVED DATE 8/20/2020 ZS/'ON AL E� ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN REVISION Aug 07 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT V z � N 0 0 00 a �� IL Y 2 coJ W din GS W �, N O Uco grnU� 0 z coN` LU 99 0 LU m J (L W E O V C + .N o c Z O y ~ a 0 y d Q C C C U 1. U y Cp g = O J N- "O .� O. m N p= L N Q. Z [11 L m m" m p m �^ y ' m p c E N a W J O C N C C N O d U/ O. !� 0 0 OWoCc°03 i.'yce3sa)`o0 O J O o p 2 O 0.2 0 2— 0 � LU aaap-'0�a��vt =�-°oya220�saEid�a�EOd J Q p H Z W O CV O 00 0111 LU Q V 0 z O � W p V Lu LU Z z W � in � _ w toe) cn W w Uix 2 w 0 W W V) 0 O 00 w 0 0 0. �L U) 0 O Z PROJECT NO. 200508 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET: S2 PRINT DATE 8/6/2020 1114 AM