Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2020-0940+REVIEWED BLDManufacturer_Specifications_and_Installation_Instructions+9.8.2020_11.56.22_AM
10/13/16 kW INCLUDES: • True Power'" Electrical Technology • Two-line multilingual digital LCD Evolution" controller (English/Spanish/French/Portuguese) GENERAL` GUARDIAN° SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating G007171-0, G007172-0 (Aluminum - Bisque) —10 kW 60 Hz G007173-0, G007174-0, G007175-0 (Aluminum - Bisque) —13 kW 60 Hz G007176-0, G007177-0, G007178-0 (Aluminum - Bisque) —16 kW 60 Hz • Two transfer switch options available: 100 amp 16 circuit switch or 200 amp service rated smart switch • Electronic governor • Standard Wi-Fi connectivity >> • System status & maintenance interval LED indicators • Sound attenuated enclosure11 GENE • Flexible fuel line connector • Natural gas or LP gas operation • 5 Year limited warranty • Listed and labeled by the Southwest Research Institute c [TI_ US or C@us �' L'nk allowing installation as close as 18 in (457 mm) to a `I �/ 0 structure.* LISTED *Must be located away from doors, windows, and fresh air Note: CETL or CUL certification only applies to unbundled units and units packaged with limited intakes and in accordance with local codes. circuit switches. Units packaged with the Smart Switch are ETL or UL certified in the USA only. https:llassets.swri.org//ibratyIDirectotyOfListedProducts/ Constructionlndustry/973 DoC 204 13204-01-01 Rev9.pdf FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's success in providing the most reliable generators possible. Generac's G- Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 %. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with ✓ PROTOTYPE TESTED NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAC ✓ SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK'" WI-FI CONNECTIVITY: FREE with select Guardian Series home standby generators, Mobile Link Wi-Fi allows users to monitor the status of the generator from anywhere in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. GENERAC PROMISE 10/13/16 kW Engine GENERAC Features and Benefits • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinderwalls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near an existing distribution panel for simple, low-cost installation. Evolution— Controls • AUTO/MANUAL/OFF illuminated buttons Select the operating mode and provide easy, at -a -glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power is delivered to the home. • Utility interrupt delay Prevents nuisance startups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load. Setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown. Setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Offers a selectable setting for weekly or monthly operation, providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure. 10/13/16 kW Installation System • 14 in (35.6 cm) flexible fuel line connector • Integral sediment trap Connectivity • Ability to view generator status • Ability to view generator Exercise/Run and Total Hours • Ability to view generator maintenance information • Monthly report with previous month's activity • Ability to view generator battery information • Weather information GENERAC® Features and Benefits Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. Meets IFGC and NFPA 54 installation requirements. Monitor your generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind. Review the generator's complete protection profile for exercise hours and total hours. Provides maintenance information for your specific model generator when scheduled maintenance is due. Detailed monthly reports provide historical generator information. Built in battery diagnostics displaying current state of the battery. Provides detailed local ambient weather conditions for generator location. 10/13/16 kW Generator GENERAC® Specifications Model G007171-0, G007172-0 113007173-0, G007174-0, G007176-0, 13007177-0, (10 kW) G007175-0 (13 kW) G007178-0 (16 kW) Rated maximum continuous power capacity (LP) Watts* 13,000 Watts* 16,000 Watts* Rated maximum continuous power capacity (NG) 9,000 Watts' 13,000 Watts` 16,000 Watts* Rated voltage 240 J111111116- Rated maximum continuous load current — 240 volts (LP/NG) 41.7 / 37.5 54.2 / 54.2 66.7 / 66.7 Total Harmonic Distortion Less than 5% Main line circuit breaker 45 Amp 60 Amp 70 Amp Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement (not included) ��olts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit weight (lb/kg) 338/153 385/175 420/191 Dimensions (LxWxH)in/cm 48 x 25 x 29 / 121.9 x 63.5 x 73.7 Sound output in dB(A) at 23 It (7 m) with generator operating at normal load** 61 65 65 Sound output in dB(A) at 23 ft (7 m) with generator in Quiet -Test- low -speed exercise mode** -1W57 55 55 Exercise duration 5 min Engine Engine type GENERAC G-Force 400 Series GENERAC G-Force 800 Series Number of cylinders 1 2 - Displacement 460 cc 816 cc Cylinder block Aluminum w/ cast iron sleeve - Valve arrangement Overhead valve Lifter type Solid Hydraulic Ignition system Solid-state w/ magneto Governor syste Electronic Compression ratio 9.5:1 Starter 12 VDC Oil capacity including filter Approx. 1.1 qt/ 1.0 L Approx. 2.2 qt/ 2.1 L Operating rpm 3,600 Fuel consumption Natural Gas ft3/hr (m3/hr) 1/2 Load 101 (2.86) 154 (4.36) 182 (5.15) Full Load 127 (3.60) 225 (6.37) 245 (6.94) Liquid Propane ft3/hr (gal/hr) [L/hr] 112 Load 36 (0.97) [3.66] 56 (1.54) [5.83] 62 (1.70) [6.45] Full Load 54 (1.48) [5.62] 90 (2.45) [9.28] 109 (2.99) [11.32] Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7.0 in water column (0.87-1.74 kPa) for NG, 10-12 in water column (2.49-2.99 kPa) for LP gas. For BTU content, multiply ft3/hr x 2,500 (LP) or ft3/hr x 1,000 (NG). For Megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons: AUTO Automatic start on utility failure. Weekly, Bi-Weekly, or Monthly selectable exerciser. MANUAL Start with starter control, unit stays on. If utility fails, transfer to load takes place. OFF Stops unit. Power is removed. Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Utility voltage loss/Return to utility adjustable (brownout setting) From 140-171 V/ 190-216 V Future set capable exerciser/Exercise set error warning Standard Run/Alarm/Maintenance logs 50 events each Engine start sequence Cyclic cranking: 16 sec on, 7 sec rest (90 sec maximum duration). Starter lock -out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Fault/Missing AC Warning Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring Protection Standard Common External Fault Capability Standard Field Upgradable Firmware Standard "Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). * Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU (Megajoule) content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5% for each 1,000 ft (304.8 m) above sea level; and also will decrease approximately 1 % for each 6 °C (10 °F) above 16 °C (60 °F). 10/13/16 kW Limited Circuits Switch Features • 16 space, 24 circuit. Breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections. • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1 in standard, tandem, GFCI, and AFCI breakers from Siemens, Murray, Eaton, and Square D for the most flexible and cost effective install. Dimensions Height Width Depth Hi H2 W1 W2 in 26.75 30.1 10.5 13.5 6.91 cm 67.94 76.43 26.67 34.18 17.54 Wire Ranges Conductor Lug Neutral Lug Ground Lug 2/0 - #14 2/0 - #14 2/0 - #14 Service Rated Smart Switch Features • Includes Smart A/C Management (SACM) module standard. • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight large (240 VAC) loads can be managed with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Dimensions 200 Amps 120/240,1 o Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 26.75 30.1 10.5 13.5 6.3 cm 67.94 76.45 26.67 34.3 16.01 Wire Ranges Conductor Lug Neutral Lug Ground Lug 400 MCM - #4 350 MCM - #6 2/0 - #14 GENERAC® Switch Options Model G007172-0 G007174-0 G007177-0 (10 kW) (13 kW) (16 kW) No. of poles 2 Current rating (amps) 100 Voltage rating (VAC) mr 120 / 240, 10 ' Utilityvoltage monitor (fixed)* -Pick-up 80% -Dropout 65% Return to utility* Approx. 15 sec Exercises bi-weekly for Standard 5 minutes* ETL or UL Listed Standard Total circuits available 24 Tandem breaker capabilities 8 tandems Circuit breaker protected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts *Function of Evolution controller Exercise can be set to weekly or monthly L DEPTH J Model G007175-0 G007178-0 (13 kw) (16 kW) No. of poles 2 Current rating (amps) 200 Voltage rating (VAC) ` 120/240, 10 Utility voltage monitor (fixed)* -Pick-up 80% -Dropout 65% Return to utility* 15 sec Exercises bi-weekly for 5 minutes* Standard ETL or UL Listed Standard Enclosure type NEMA/UL 313 Circuit breaker protected ! 22,000 Lug range 250 MCM - #6 *Function of Evolution Controller Exercise can be set to weekly or monthly L DEPTH - GENERAC 10/13/16 kW Model # G005819-0 G007101-0 G007102-0 G007103-1 G005621-0 G007027-0 - Bisque G005703-0 - Bisque G006482-0 —10 kW G007216-0 —13 / 16 kW G007005-0 Available Accessories Product r Description _ 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact ). Battery Pad Warmer The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0 °F (-18 °C). (Not necessary for use with AGM -style batteries). Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 0 °F (-18 °C) Breather Warmer The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you Contact Kit may not need. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a sleek, Fascia Base Wrap Kit contoured appearance as well as offering protection from rodents and insects by covering the lifting holes lo- cated in the base. Touch -Up Paint Kit If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future corrosion. The paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the items necessary to perform complete routine maintenance on a Generac automatic standby generator (oil not included). Wi-Fi LP Fuel Level Monitor G007000-0 (50 amps) I Smart Management Module G007006-0 (100 amps) II! G007169-0 Mobile Link'"' 4G LTE Cellular Accessory Model UPC G007171-0 696471074680 G007172-0 696471074673 G007173-0 696471076400 G007174-0 696471077100 G007175-0 696471077117 G007176-0 696471076417 G007177-0 696471077124 G007178-0 696471077131 The WPH enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify users when the LP tank is in need of a refill. Smart Management Modules (SMM) are used to optimize the performance of a standby generator. It manages large electrical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using SMM's can reduce the overall size and cost of the system. The Mobile Link 4G LTE Cellular Accessory allows users to monitor the status of the generator from anywhere in the world, using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account with an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. [25.5 in] LEFT SIDE VIEW Dimensions & PCs [48.51n] FRONT VIEW Dimensions shown are approximate. See installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENE RAC° Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2019 Generac Power systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. 10000033190 Rev. A 07/26/19