Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FIR2020-0096+Fire_Alarm_Equipment_Specification_Sheets+11.4.2020_3.04.43_PM
F I R2020-0096 r • • RECEIVED Nov 04 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Addressable Fire Alarm Control Panel The 6808 is an addressable fire alarm control panel (FACP) that can be configured to achieve an overall point capacity of up to 198 points. It has one built-in signaling line circuit (SLC), which can support 99 System Sensor' (SK) sensors and 99 SK modules or 127 Hochiki ' (SD) devices per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single -point communications. It also has a built-in, dual - tine POTS and IP communicator and optional cellular side -cars. 6808 The 6808 system can be enhanced by adding modules such as the 6860 remote annunciator which also has four programmable function It supports a variety of devices, including the buttons to help automate tasks and reduce time spent at the panel. 6860, 5860, and 6855 remote annunciators, 5824 serial parallel printer interface module (for SWIFT' wireless compatibility provides options for wireless detection printing system reports), the 5496 NAC expander, through a Class A mesh network. It is ideal for hard -to -wire locations, 5895XL power module, and SK or SD devices. buildings where new wiring is not allowed, or to provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard -wired 6808 compatible devices. The 6808 also has Form C trouble relay, and two programmable Form C relays, along with powerful features such as drift compensation, pre - trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and calibration trouble alert. • Capable of providing LIP to 1.98 points to satisfy smaller installation needs • Connect up to 17 panels on one site with convenient single - point access using the SK-NIC Network Interface Card. Connected panels can have mixed compatible FACP models. • Convenient field-upgradeabte firmware • Integrated dual path IP and POTS communications and optional cellular side -cars for reliable backup • 6860 annunciator with a 4 x 40 large display, and 4 programmable function buttons. Free -up time spent at the panel. Program them for simple or complex tasks. • Built-in USB interface for convenient and quick programming • Programmable date setting for automatic and convenient Daylight Saving Time changes • Built-in dual phone line and digital alarm communicator/ transmitter (DACT) for additional communication options • 125 software zones and 125 output groups for flexible design options 6808 Product Information SIGNAL LINE CIRCUIT (SLC) The 6808 SLC loop supports multiple device types, maintenance alerts, and a built-in sensor test to comply with NFPA 72 calibration testing requirements. INDICATOR LIGHTS • General Alarm (Red): Flashes if in alarm; solid when alarm is silenced • Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced • System Troubles (Yellow): Flashes if a trouble condition exists; solid when trouble is silenced • System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared • System Power (Green): Flashes for AC failure; solid when power systems are normal USERINTERFACE The 6808 built-in 4 x 20 annunciator with 80 character LCD display and large easy -to -use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built- in or remote annunciator. System operations can be initiated with a mechanical firefighter's key or a valid 4- to 7-digit operator's code. 6808 KEYPAD PROGRAMMING The 6808 system offers several options to simplify and speed-up programming. JumpStartE Auto Programming minimizes programming required to start a new system. The built-in keypad, or the 6860, 5860 or 6855 remote annunciators give you on -site access to current system programming. You can also program the system using the Honeywell Fire Software Suite (HFSS), which is Windows' based. SOFTWARE TOOLS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows" software system configuration toot to create a detailed Bill of Material (BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires a Windows -based computer. ADDITIONAL INFORMATION Twisted -unshielded pair wire is recommended. The 6808 also has 13 preset notification cadence patterns (including ANSI 3.41). AGENCY LISTINGS AND APPROVALS NFPA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non -coded) signaling services. • UL Listed • CSFM 7165-0559:0502 • FDNY COA# 6246 • FM approved • Seismic (CA) (pending) ORDERING INFORMATION 6808: Addressable Fire Alarm Control Panel. (Red cabinet). COMPATIBLE ANNUNCIATORS 6860: 4x40 LCD remote fire annunciator (4 lines and up to 160 characters) per system; four programmable buttons 5860: 4x20 LCD remote fire annunciator. 5860 is gray; 5860R is red 6855: 4x20 LCD remote fire annunciator 5865-3 or 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). The 5865-4 has key switches for silence and reset, and a system trouble LED. 5880: LED / 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6808 COMPATIBLE DEVICES AND ACCESSORIES See the data sheets listed below for a complete listing of the SK, SD or SWIFT devices. 53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614, 350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories go to www.sitentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 1350F fixed temperture SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T.- Reflected beam smoke detector with test feature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended airspeed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-ROR: Fixed rate of rise detector (135°F) SK-HEAT-HT. Fixed high temperature thermal detector (190°F) SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10:10 input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-T.- Photoelectric smoke detector with thermal (1350F fixed temperture) SK-PHOTOR: Photoelectric detector with remote test capability SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module B210LP: 6" mounting base B501:4" Flangeless mounting base B200S: Intelligent sounder base B200S-LF: Low -frequency intelligent sounder base B224RB: Relay base B224BI: Isolator base SO COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6" base SD505-61B: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch and LED indicator for the SD505-DUCTR SD505-DUCT: Addressable Duct Smoke Detector. SD505-DUCTR: Addressable Duct Detector housing with relay base. SD505-HEAT: Absolute temperature heat detector. Trip point range from 135°F-150°F(0°C-370C). SD500-LIM: Addressable Line isolator module SD500-MIM: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: "R" indicates red; "W" denotes white. For a complete listing of Silent Knight AV devices go to www.sitentknight.com. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime HRL/HWL: Wall horn P2RL/P2WL: Watt horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Walt strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Walt speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD.) devices. WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Photoelectric smoke detector WSK-PHOTO-T: Wireless Multi -criteria photoelectric smoke detector with thermal detection (1351Ffixed temperture) and B510W 4" base WSK-HEAT: Wireless Heat, (135°F fixed temperture) and B510W 4" base WSK-HEAT-ROR: Wireless heat, ROR (135°F fixed temperture) and B510W 4" base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module W-USB: SWIFTTools USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 5496: A 6 amp notification power expander with four power -limited notification appliance circuit outputs. 5883: Relay Interface. Provides 10 Form C relays. 5824: Serial/Parallel Printer Interface Module for printer connection. 5895XL: Power Supply with six Flexput- circuits, and two Form C relays. Max. 16 per system. 5815RMK: Remote mounting kit. Dimensions: 10 3/8"W x 10-3/16"H x 3"D COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock/key* CELL -MOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-I13-2: Remote reporting via the Internet. Requires a VisorAlarm* receiver at the central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the 6808. SK-NIC-KIT• Installation Accessory Kit SK-FML: Fiber -Optic Multi Mode, transmitter and receiver SK-FSL: Fiber -Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too large to fit in the FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406mm W x 254mm H x 152mm D). SK-SCK: Seismic Compliance Kit used to securelyfasten batteries to the fire panel. 6808 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS (NACs) For a complete listing of all Overall Dimensions:16.36"W x 26.37"H x 3.91"D Four programmable circuits which can be compliance approvals and Shipping Weight: 32 lbs. programmed individually as: certifications, please visit Color: Red NACs: 3A @ 27.4VDC per circuit, power -limited www.sitentknight.com, (with a maximum current of 6A) Microsoft, Windows, and ENVIRONMENTAL Auxiliary Power Circuits: 3A @ 27.4VDC per circuit, the Windows Logo are Operating Temperature: 32°Fto 120°F (OoC to power -limited registered trademarks FSl C) or trademarks of Microsoft Corporation. Humidity: 0 to 93% relative humidity (non- Supports Class B (Style 4) and Class A (Style 6 or 7) condensing) 9 configuration for the SLC Silent Knight", Honeywell*' and SWIFT" are registered ELECTRICAL WIRING: See the product manual for wiring details trademarks of Honeywell International, Inc 6808 Primary AC: 120VAC @ 60Hz, 3.3ATotal Accessory Load: 6A @ 27.4VDC power -limited This document is not Standby Current: 190mA intended to be used forinstallation Alarm Current: 250mA purposes. We try to keep our product Battery Charging Capacity: 7 to 35AH information up to Battery Size: 7AH to 18AH max, allowed in control date and accurate. We panel cabinet. Larger capacity batteries can be cannot cover all specificapplications housed in RBB accessory cabinet. or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, catI800-446 6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.siLentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 351608I A 111i17 H�i� 800-328-0103 U 2017 Honeywell International Inc. 3 SILENT 5860 Remote Annunciator KNIGHT by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility. Now you can operate and program your IntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy -to -use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error -free system operation. All operations —including reset, silence, detector status checking, fire drill, and programming —are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description Features include an 80-character backlit LCD providing easy -to - understand system messages. The annunciator is ergonomically designed with over -sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. Features • 80-character backlit LCD display (4 lines with 20 characters on each line) • Tactile and audible feedback • Accepts user codes or fire fighter's key • Larger keypad buttons for system reset and silence • Install up to eight 5860s per FACP • Available in red or light gray • Support for simultaneous use of multiple 5860s • RS-485 interface to panel • Operation and appearance is identical to 5860 built-in annunciator • On -board piezo sounder audibly indicates alarms, troubles, and supervisories • Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions • Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) • UL listed, complies with NFPA 72 • CSFM approved Electrical Specifications Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Max Per System: 8 Mechanical Specifications Physical 9.1" W x 7.4" H x 1.5" D (23.1 W x 18.8 H x 3.8 D cm) Shipping Weight: 2.8 Ibs (1.3 kg) Color 5860R: Red 5860: Gray 5860 Environmental Operating Temperature: 320F — 120°F (0°C — 49°C) Humidity: 10% — 93% non - condensing Compatibility The 5860 is compatible with the following FACP's: • 5820XL Addressable Fire Control Panel • 5820XL-EVS FACP with Emergency Voice System • 5808 Addressable Fire Control Panel • 5700 Addressable Fire Control Panel Listings NFPA 72; UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol. IX; FM Approved 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. i c Ordering Information 5860R Remote Annunicator four line LCD annunciator with 20 characters per line. Red. 5860 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring for surface mounting. 5860TG Gray Trim Ring for surface mounting. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350224 Rev F subject to change without notice. For more information, contact Silent Knight © 2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com Honeywell SILENT' IrINIGMT SK-PHOTO-W Series Intelligent Plug -In Photoelectric Smoke Detector Honeywell Silent Knight SK-PHOTO-W Series plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (5710 fixed temperature thermal sensing on the SK-PHOTO T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DNR Series duct detector housings. FEATURES) & BENEFIT: • New modern profile for • Dual LED design improved aesthetics provides 3600 viewing • 5tabEe communication angle technique with noise immunity • Low standby current • Two -wire SLC connection • Optional remote, single- gang LED accessory • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Built-in tamper - resistant feature • Seated against back pressure • Expanded color options • SEMS screws for wiring of the separate base SK-PHOTO-W • Optional relay, isolator, and sounder bases • Plugs into separate base for ease of instattation and maintenance DETECTOR SPACING AND APPLICATIONS Honeywell recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72, System Smoke Detector Application Guide, document A05-1003, is available at systemsensor.com INSTALLATION The SK-•PHOTO-W Series plug-in detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. NOTE: - Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class °B") wiring. - When using relay or sounder bases, consult the installation sheet for device limitations between isolator modules and isolator bases. ORDERING INFORMATION SK-PHOTO-W: Photoelectric smoke detector, white. SK-PHOTO-R-W: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, white. SK-PHOTO T-W: Photoelectric smoke detector with thermal sensing, white. INTELLIGENT BASES 13300-6: White, standard flanged low -profile mounting base. B300-6-BP: Bulk pack of B300-6, package contains 10. B300-6-IV: Ivory, standard flanged low -profile mounting base. B501-WHITE: White, standard European fl.angetess mounting base. Ul-. listed. B501-BL: Black, standard European flangeless mounting base. UL listed. B501-IV: Ivory, standard European flangeless mounting base. UL listed. B20OS-WH: White, Intelligent, programmable sounder base. B20OS-IV: Ivory, Intelligent, programmable sounder base. B200SR-WH: White, Intelligent sounder base for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base for retrofit applications. B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base. B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications. B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications. B224RB-WH: White, plug-in System Sensor relay base. B224RB-IV: Ivory, plug-in System Sensor relay base. B224BI-WH: White, plug-in System Sensor isolator detector base. B224BI-IV: Ivory, plug-in System Sensor isolator detector base. ACCESSORIES CK300: Color Kit (includes cover and trim ring), white, 1.0-Pack. CK300-IV: Color Kit (includes cover and trim ring), ivory,l0-Pack. CK300-BL: Color Kit (includes cover and trim ring), black,l0-Pack. M02-04-01: Detector test magnet. M02-09-00: Telescoping test magnet. RA10OZ: Remote LED annunciator SMB600: Surface Mounting Kit (flanged). TR300: Replacement trim ring for B300-6, white. TR300-IV: Replacement trimring for B300-6-IV, ivory. SK-PHOTO-W Series Detector Technical Specifications PHYSICAL Height: 2.0" (51mm) installed in B300-6 base Diameter: 6.2" (156mm) installed in B300- 6 base 4.1" (104 mm) installed in B501 base Weight: 3.4 oz (95 g) ENVIRONMENTAL Operating Temperature range: Photo: 320F to 122°F (0°C to 50°C) Photo with Thermal: 32°F to 100°F (0°C to 38°C) UL listed Velocity range: Photo/Photo with Thermal: 0 to 4,000 fpm (0 to 20 m/sec) (suitable for installation in ducts) Humidity: 10%to 93% non -condensing Thermal Ratings: Fixed Temperature Set point: 1350F(570C) ELECTRICAL RATINGS Voltage Range: 15 to 32VDC peak Operating Current @ 24VDC: 200l A (one communication every 5 seconds with green LED blink on communication) Maximum Current: 4.5mA `@ 24VDC (one communication every 5 seconds with amber LED solid on). For more information Learn more about Honeywell Silent Knight and other products byvisiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 COMPATIBILITY The SK-PHOTO-W series detectors are compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressabte fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system AGENCY LISTINGS AND APPROVALS For exact certification listings for each model, please reference the respective agency Web site. UL listed: S6173 FM approved CSFM: 7272-0559:0523 Doc 3516341 Rev A 104/18 @ 2018 Honeywell International Inc. For a complete listing of ali compliance approvals and certifications, please visit www.sitentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight System Sensor' and Honeywell" are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, ca11BOO 446-6444. a Honeywell SH-FNT' KNIGHT' SK-HEAT-W Series Intelligent Thermal (Heat) Detector Honeywell Silent Knight SK-HEAT-W Series intelligent thermal detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the SK-HEAT-W Series ideal for both system operation and building design. The point ID address, set using rotary decimal switches, provide specific detector locations. The series includes a 1351F/570C fixed temperature, rate -of -rise and a 1901F/881C fixed high -temperature detectors. These i thermal detectors provide effective, intelligent property protection in a variety of applications. FEATi` RES & BENEFITS • Sleek and stylish contemporary design • Advanced thermat technology for fast response • Fixed temperature model (SK-HEAT-W) factory preset to 135°F(57°C) • Rate -of -rise model (SK-HEAT-W-ROR), 15°F(8.3°C)per minute • High temperature modet(SK-HEAT.- W-HT) factory preset to 190OF (88cQ • Addressable by device • Two -wire SLC connection • Visible LEDs 'blink" every time the unit is addressed • Buitt-In tamper resistant feature • 3601-field viewing angle of the visual alarm indicators (two bi-color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. • Integral communications and built-in device -type identification • Remote test feature from the panel SK-HEAT-W • Built-in functional test switch activated by external. magnet • Walk test with address display (an address of 121 will blink the detector LED 12- (pause)-1) • Low standby current • Designed for directsurface or electrical box mounting • Seated against back pressure • Plugs into separate base for ease of installation and maintenance • SEMS screws for wiring of the separate base • Optional remote, single- gang LED accessory APPLICATIONS INTELLIGENT BASES ACCESSORIES Use thermal detectors for protection of property. For further information, refer to manual 156-6541, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications INSTALLATION TheSK-HEAT-W Series plug-in intelligent thermal detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector Mount base (all base types) on an electrical backbox which is at least 1..5" (3.81 cm) deep. NOTE: Because of the inherent supervision provided by the SLC loop, end -of -tine resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. - When using relay or sounder bases, consult the installation sheet for device limitations between isolator modules and isolator bases. NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. ORDERING INFORMATION SK-HEAT-W: Thermal heat detector, 135°F fixed, white. SK-HEAT-ROR-W: Thermal heat detector, 135OF rate of rise, white. SK-HEAT-HT-W: Thermal heat detector, 190OF high temp, white. B300-6: White, standard flanged tow-profite mounting base. B300-6-BP: Bulk pack of B300-6, package contains 10. B300-6-IV: Ivory, standard flanged low -profile mounting base. B30OA-6-IV: Ivory, standard flanged tow -profile mounting base. UL_ listed. B501-WHITE: White, standard European ftangetess mounting base. UL listed. B501-BL: Black, standard European flangeless mounting base. UL listed. B501-IV: Ivory, standard European flangeless mounting base. UL listed. B20OS-WH: White, Intelligent, programmable sounder base. B20OS-IV: Ivory, Intelligent, programmable sounder base. B200SR-WH: White, Intelligent sounder base for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base for retrofit applications. B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base. B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications. B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications. B224RB-WH: White, plug-in System Sensor relay base. B224RB-IV: Ivory, plug-in System Sensor relay base. B224BI-WH: White, plug-in System Sensor isolator detector base. B224B1-IV: Ivory, plug-in System Sensor isolator detector base. CK300: Color Kit (includes cover and trim ring), white, 10-Pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-Pack. CK300-BL: Color Kit (includes cover and trim ring), black,10-Pack. M02-04-01: Detector test magnet. M02-09-00: Telescoping test magnet. RA10OZ: Remote LED annunciator SMB600: Surface Mounting Kit (flanged). TR300: Replacement trim ring for B300-6, white. TR300-IV: Replacement trimring for B300-6-IV, ivory.. SK-HEAT-W Series Detector Technical Specifications PHYSICAL Height: 2.0" (51mm) installed in B300-6 base Diameter: 6.2" (156mm) installed in B300-6 base 41" (.1.04 mm) installed in B501 base Weight: 3.4 oz (95 g) ENVIRONMENTAL Operating Temperature range: Heat -Fixed temperature: -4°F to 100°F (-20°C to 38°C) Heat -Rate of Rise (ROR): -4°F to 100OF (-20°C to 38' ) Heat -High Temperature: 4°F to 150OF (-20°C to 66°C) Humidity: 10%to 93% non -condensing Thermal Ratings: Fixed Temperature Set point: 1350F (570C) Rate -of -Rise Detection: 151F/min. (8.31C/min High Temperature Heat: 190°F (880C)Etectrical Ratings ELECTRICAL RATINGS Voltage Range: 15 to 32VDC peak Standby current (max. avg.): 200uA @ 24 VDC (one communication every 5 seconds with LED enabled). LED current (max.): 4.5mA L 24 VDC ("ON"). For more information Learn more about Honeywell Silent Knight and other products byvisiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 COMPATIBILITY The SK-HEAT-W series detectors are compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system AGENCY LISTINGS AND APPROVALS For exact certification listings for each model, please reference the respective agency Web site. UL listed: S2101 FM Approved CSFM: 7270-0559:0511 Doc 351637 1 Rev A 104/18 © 2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.sitentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight', System Sensor' and Honeywell" are registered trademarks of iioneywetl International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support. ca11800-446 6444, !-A 1711 �e � SILENT SK-Pull-SA and SK-Pull-DA 3:h, KNIGHT by Honeywell Intelligent Pull Stations The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only my now one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition • Dual -color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Meets ADA requirement for 5 Ibs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® • Reliable analog communications for trouble -free operation • Braille text on station handle • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • Rotary address switches for fast installation • UL Listed, including UL 38, Standard of Manually Actuated Signaling System SK-Pull-SA SK-Pull-DA Compatibility The SK-Pull-SA and SK-Pull-DA are compatible with the following IntelliKnight FACP's: 5600 5700 5808 5820XL Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans, Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. Wiring SK-Pull-SA & SK-Pull-DA Pull Stations Specifications Physical Height: 5.5" (14 cm) Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC Average Operating Current (LED flashing): 300 pA Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Operating Temperature 320 — 120OF (0°C — 49°C) Humidity: 10% — 93% non -condensing Accessories BG-TR Optional trim ring. SB-1/0 Surface backbox SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com MADE IN AMERICA FORM# 350135 Rev B © 2012 Honeywell International Inc. Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela to Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices • Compatible with MDL3 sync module • Listed for wall mounting only Agency Listin s SIGNALING 61 <F fM�: LISTED APPROVED S5512 FM approved except 71254653*M S4011 ter ALERT models 7135-1653:05M 3057363,3057072 The System Sensor L4orles offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double -gang back box. L-Series compact products shall mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit- Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR' 2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6"L x 4.7"W x 1.91"D (143 mm L x 119 mm W x 49 mm D) Compact Wall -Mount Dimensions (including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7-W x 1.25-D (143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" L x 3.45" W x 1.25" D (133mm L x 88mm W x 32mm D) 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 UL Max. Horn Current f 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non -Temporal High 43 47 54 Non -Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3A KHz Temporal Low 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Current fStrobe,8-17.5 DC input Volts 15cd 30cd 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non -Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3. 1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non -Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non -Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non -Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1 K Non -Temporal High 104 131 177 204 230 264 326 3.1 K Non -Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data riorn anal morn ZStrobe . 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 ' Settings 9 and 10 are not available on the 2-wire horn strobes L-Series Dimensions 3.46 _ 1.25 �i0o444 r� 5.27 �o Compact Strobe J Horn Strobe ._....._ 4.70 ........_ .... .........__ 1.91 ...................'. i'--- — 1.25 5.67 Strobe t Horn Strobe L-Series Ordering Information .. Wail Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P26WL 2-Wire, Compact Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT 3.46 00000 0 0 00000000000 00000000000 000 5.27 Q0°p°0p°p°p°° o°e°o°°°°°o° o°n®°o°°0°0®0 °°°°°aoa®°°°° e°ro°®o�e�are .... o Compact Horn _ 4.70 IRYA Horn 1.25 1.25 ModelDescription Horns HRL Horn, Red HWL Horn, White HGRL Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wail Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover All -ALERT models have "ALERT" marking on cover SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 02017 System Senses. Phone: 800-SENSOR2 • Fax: 630-377-6495 Produce specifications moect to change AtwII raUce. Visitsymm stesenw.co for cunent pmdtmt information, including the latest version of this data sheet. SENSOR' www.systemsensor.com AVDS8650.i• 03/17 SYS iso Indoor Selectable - Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on ceiling units: 15, 30. 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only Aaencv Listinas SIGNALING Uctto APPROVED ."- S552 FM approved except 71Y5-1653:t1509 54011 for ALFAT models 7135-1653:05M 30,57383 The System Sensor L•Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings: automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series ceiling -mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double - gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the SynceCircuit- Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the SynceCircuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor SynceCircuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling -Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVD588800 UL Current Draw Data Candela ^1115) 8-17.5 Volts DC 16-33 Volts DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 Max. Current Draw (mA RMS), 2-Wire StrobeUL Horn DC input 8-17.5 Volts 15cd 30cd 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non -Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non -Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non -Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non -Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non -Temporal High 108 135 179 200 225 255 289 3.1 K Non -Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data norn ano morn• 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 _ 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 AVDS86F= L-Series Dimensions 6.83 — 2.47 1.37 Ceiling -Mount Horn Strobes Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information t, - Ceiling Horn Strobes PC2RL 2-Wire. Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White 6.92 2.50 O TR O O o 0 0 O 00 O o Q o 0 Ceiling Surface Mount Back Box DescriptionModel Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White SYSTEM @2017 System Sensor 3825 Ohio Avenue • St. Charles, IL 60174 Prodocts{wcificationssubi A to chance wrtwut notice.. Visit ystamsenscccom SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 twcunentproductinto,,,'AVDS86dincthelatas versiono'thisdafasheet. AVDSRAAO? • 03/?7 Outdoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlerle Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field -selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from —40°F to 151'F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Listed for ceiling or wall mounting Agency Listings SfGNAL1IN. ti (9 LISTED IF ne MEA 7300-1663:167 (outdoor strobes) approved 7125-1653: 188(horn strobes. 54011 (chimes, horn strobes. horns) APPROVED Pp chime strobes) 8359.3 (outdoor and alert strobes) 307.3572 ;JEA452-U E 7135-1653:189 (horns, chimes) • 0 A r S t t S SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40°F to 151 °F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/-inch top and bottom conduit entries and 3/-inch knock -outs at the back. A screw -in NPT plug with an O-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40'F to 151 °F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangez 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6"L x 4.7-W x 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7-W x 1.3"D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7-L x 5.1 "W x 2.0"D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S. PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AMS01201 UL Current Draw Data Candela 8-17.5 Volts DC FWR 16-33 Volts DC FWR Standard 15 123 128 66 71 Candela 15(75 142 148 77 81 Range 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela 150 NA NA 246 220 Range 177 NA NA 281 251 UL Max. Horn Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non -Temporal High 57 56 69 75 Non -Temporal Medium 42 50 60 69 Non -Temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 185 NA NA 286 258 Max. Current Draw (mA DC input RMS), 2-Wire 8-17.5 Volts 15 Horn 15175 Strobe,UL 16.33 Volts 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low Max. Current Draw (mA DC Input 132 RMS), 2-Wire 16-33 Volts 135 150 154 Horn Strobe,UL 177 80 High Candela 185 90 105 161 FWR Input 184 16-33 Volts 135 150 202 177 211 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strob- Output Horn Tones and Sound Output Data 8 175 16-33 Switch Sound Volts Volts Position Pattern dB DC FWR DC FWR 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR Listed Candela Candela rating at-40'F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 1177 185 1185 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 91. Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS01201 SpectrAlert Advance Diagrams Wall -Mount Horn Strobes LVEM erproof Back Box w Waif -Mount Horn Strobe with Plastic Weatherproof Back Sox SpectrAlert Advance Ordering Information DescriptionModel Wall Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wail Strobes SRK*f Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High old, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*f Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRK' Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: * Add %P" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add %R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. SYSTEM 02012 System Sensor /� 3825 Ohio Avenue • St. Charles, IL 60174 Productsfoamifioation.wbjecttochangeVmhoutnotice. visitsystemsansorxom SENSOR' Phone: 800-SENSOR2 • Fax: 630-377-6495 for anent prmitstinformation. including the latest version of this data sheet. AVDS01201 * V12 SILENT SK-Relay KNIGHT by Honeywell Intelligent Relay Module The SK-Relay Module is intended for use in intelligent, two -wire systems where the individual address of each module is selected using the built in rotary switches. For more information about the IntelliKnight system, or to locate you nearest source, please call 800-328-0103. Description The SK-Relay is an addressable relay module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK-Relay allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The SK-Relay contacts can be used for virtually any normally open or normally closed application. Each SK- Relay is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the SK-Relay, the relay is triggered by the FACP. Features • Two sets of Form C contacts • Rotary address switches for fast installation • Contacts are rated for a variety of amps (see Specifications) • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Relay programming is completely flexible —can be mapped to zone conditions • Polling LED visible through the cover plate • Attractive ivory cover plate • SEMS screws for easy wiring • UL Listed SK-Relay Installation The SK-Relay mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight Compatibility The SK-Relay is compatible with the following IntelliKnight FACP's: 5820XL 5820XL-EVS 5808 5700 5600 (Rev 2.0 or higher) Model SK-Relay Intelligent Relay Module To Next Device + 0O o V Relay Common 2 • •;:. • Normally Closed 2 • Sr + Normally Open 2 ►'• _ Relay Common 1 • ;'` a Normally Closed 1 • •` s Module Does Not Supervise [1 O f7 Controlled Circuits v V Specifications Physical Height: 4.65" Width: 4.25" Depth: 1.1" Shipping Weight: 6.3 oz (196 g) Electrical Operating Voltage: 15 — 32 VDC Current Draw: 6.5 mA max (LED on) Operating Current: 230 pA (LED flashing) direct poll 255 pA (LED flashing) group poll If Any Wiring to Terminals 3 — 9 is Not Power Limited, the CB600 Barrier is Required. The CB600 Includes a Non -Power Limited Label, Which Must Be Placed Over the Power Limited Terminal Information on the Name Plate Label. — From Compatible FACP + or Previous Device Normally Open 1 Wiring the SK-Relay Module End -of -Line Resistance: not used Standby Current: 300 pA max @ 24 VDC (one communication every 5 sec with LED enabled) LED Current: 5.5 mA (with LED latched on) SLC Loop Resistance: 400 max. Relay Contact Ratings 3.0A @ 30 VDC resistive 0.9A @ 110 VDC resistive 0.9A @ 125 VAC resistive 0.5A @ 125 VAC inductive (PF = .35) 0.7A @ 75 VAC inductive (PF = .35) SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA KNIGHT to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350127 Rev D subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: © 2013 Honeywell International Inc. (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please Call 800-446-6444. www.silentknight.com AC E kflv � SRD ACE-11 System Record Documents X BY SPACE AGE ELECTRONICS w FEATURES • 18 gauge cold rolled steel S�N..0 construction with red powder coat and white lettering • Dimensions are 12" wide x 13" tall and 2 1/4" deep LISTED • Stainless steel piano hinge • Two key ring hooks to hold system keys Business card holder for key contacts • Slide tab allows user to select USB-C or Micro USB connector to download from 8GB digital flash memory • DCD Computer Desk Kit (sold separately) holds enclosure door open at a 90 degree angle with a snap on cable for a convenient working surface in the field. Includes velcro strap for securing your laptop. Store important system documents in a secure location with a cabinet built specifically to meet the requirements of NFPA 72 7.7.2.4. The number one goal at Space Age is to manufacture code compliant solutions, and the SRD is just that. NFPA 72 7.7.2.1 states, "With every new system, a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises." The SRD includes our innovative 8GB flash drive slide tab that allows the user to select a USB-C or Micro USB connector to access records electronically (See NFPA 72 7.5.6.7). SPECIFICATIONS The SRD System Record Documents Box shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a powder coat finish. The cover shall be permanently screed with 1" high lettering "SYSTEM RECORD DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and there will be a 12" stainless steel piano hinge. The SRD will have a minimum of 8 gigabyte digital flash memory drive with a slide tab that allows user to select USB-C or Micro USB connector for uploading and downloading information. The enclosure will supply 4 mounting holes. Inside will accommodate standard 8 1/2" x 11" manuals and document records. A legend sheet will be attached to the door for system required documentation, key contacts and system information. The enclosure shall also provide 2 key ring holders with a location to mount standard business cards for key contact personnel. CUSTOM COLORS AND BRANDING AVAILABLE Pg. 1 /2 DIMENSIONS 2.35 ------ -_� ................T.. 12.59 13.00 t.. ORDERING INFORMATION I P/N# SS000689 SRD System Record Documents Box - Red P/N# SS000690 SRD System Record Documents Box - Red with your custom screened logo P/N# SSU01689 SRD System Record Documents Box - Black P/N# SSU01690 SRD System Record Documents Box - Black with your custom screened logo P/N# SS000616 DCD Computer Desk Kit www.lsae.com I toll free 1.800.486.1723 1 fax 508.485.4740 © Copyright 2018 Space Age Electronics, Inc. I This document subject to change without notice I LT10641 I Rev. E Nmom * AM Pg. 2/2