FIR2022-0129+Fire_Alarm_Equipment_Specification_Sheets+12.2.2022_8.48.18_AM+3248238SILENT
KNIGHT
FIRE SYSTEMS®
EXISTING FIRE PANEL
FEATURES:
• Eight zones, 6 Style A (class B) and 2 Style D (class
A). 8 Expander Zones are Style A (class B). Zones
are interchangeable using the Model 7181 Zone
Converter.
• UL, FM, MEA (BSA), CFM Listed and Approved.
• Event memory.
• Fuseless design can reduce service time.
• Field selectable, 12 or 24 VDC power supply.
• Six amp current output at 12 volts, five amps at
24 volts.
• Compatible with 2- and 4- wire smoke detectors as
well as water flow and sounding devices.
• ANSI Cadence Pattern Output.
• Four programmable (Style Y) supervised signal
circuits, including steady, pulse and temporal.
• Programmable smoke verification, pre -alarm delay,
and cross -zoning can minimize false alarms.
• Four general purpose relays (Form C 24 volts at 2.5
amps resistive).
• Built-in approved digital communicator with UL
required priorty reporting.
• Flexible programming capabiities including up/
downloading and use of remote annunciator. No
"desktop" programmer required.
• Accu-ZoneO diagnostics facilitate local and
remote troubleshooting.
• Individual zone Walk Test.
DESCRIPTION:
The Model 5207 is an all -in -one fuseless local fire
evacuation control panel and digital
communicator designed for applications requiring
manual fire alarm, automatic fire alarm and water flow
for sprinkler system supervision. The basic unit offers
fire alarm for one to eight zones, expandable to 16 with
the optional 5210 expansion module. It is compatible
with both two- and four -wire smoke detectors. Compact,
easy to install and service, it delivers the features you'd
expect to find in fire systems costing much more.
During normal operation, the 5207 constantly checks
smoke and other sensing devices for fire conditions. It
also conducts system checks to determine if any troubles,
COMMERCIAL
FIRE ALARMS
5207
or system problems, exist. If the 5207 encounters a fire
or trouble condition, it sends a report to a central
monitoring station (if applicable), and, typically, sounds
an audible/visual warning in the local area.
The 5207's microprocessor constantly runs programs to
check inputs and carry out other routine functions. If the
program ever stops running, a watchdog circuit will
detect it and reset microprocessors to resume normal
operations.
The Model 5207 conducts an automatic self -test every
24 hours —at a time you select —and sends a report to
the central station (if applicable).
Other features of the system include English -language
remote annunciation simplifying "Step Programming" of
custom options. Remote downloading of system
configurations can eliminate the expense of sending out
a service technician for reprogramming. System provides
a built-in fire drill procedure. The exclusive Accu-Zone`"
feature measures and displays zone voltages, so you
can set up and test the system without separate testing
equipment. Fuseless circuit board design eliminates
one of the most likely causes for service calls.
PROGRAMMING
ANNUNCIATION
5521
On -site programming is available through the optional
Model 5521 Desktop Programmer or through any
remote annunciator.
Remote programming can be accomplished through the
use of 5521 programmer and 5530 modem, or through
the use of an IBM or compatible personal computer and
the Model 5541 Downloading Software (requires the
Model 5530 Downloading Modem).
More than 60 programmable options are available for
customizing system configurations and end -user
features, including zone type (fire, panic, tamper,
sprinkler, water, heat, cold, local); zone options (pre -
alarm delayed, smoke verification delayed, zone disable);
and zone location descriptions. Programmable dialer
options include total number of reporting attempts, Touch-
ToneO or rotary dialing, one or two telephone lines.
Several time delayfeatures, including numberof seconds
to alarm in pre -alarm, smoke delay conditions, number
of hours before loss of AC hours report, and 24-hourtest
time, can be programmed.
ZONE EXPANSION
The optional Model 5210 Zone Expander doubles the
number of zones available to the 5207 from 8 to 16. The
5210 adds eight additional style A (class B) zones to the
5207, enabling use of both two- and four -wire
smoke detectors.
Voltage Ranges: Using 24-VDC power: 17.8-27.4 VDC
Using 12-VDC power: 8.5-11.8 VDC.
5210
The 5207 includes an annunciator inside the cabinet. Its
six LEDs (for alarm, trouble, silenced, AC/low battery,
event memory, time set/reporting) are visible without
opening the cabinet. The annunciator allows for easy
operation of all functions. Itfeatures dual seven -segment
display and 14 uniquely assigned function keys. Keys
are: ENTER, CLEAR, SILENCE, SHUNT and 0-9 used
forALARM RESET, CLEARALARM MEMORY, DIALER
RESET, REQUEST DOWNLOAD, DISPLAY MEMORY,
TEST, DISPLAY TROUBLES, SET DATE and
SET TIME.
Remote annunciation is available through the Model
5230. This four -wire, 16-zone remote annunciator is
easy to operate. Its fourteen function keys can perform
the same operations as the main system annunciator,
including silencing, resetting, and displaying of alarms,
troubles and alarm memory. Use of access codes
prevents unwanted tampering. In addition the Model
5230 can be used to program all programmable options
for both the local control and digital communicator.
Features include LCD display, backlighting, English -
language annunciation.
Up to seven 5230s can be attached to one 5207. Standby
current draw per 5230 is 60 mA, alarm current is 120 mA.
5230
COMMUNICATIONS/REPORTING
The 5207 is equipped with a UL listed digital dialer
which has the ability to seize the telephone line(s) to
report alarms and troubles to a central station. It can
supervise the telephone lines and activate a trouble -
alert if aline failure is sustained for 45 seconds or longer.
Other communications/reporting features include: Built-
in ring detector; re -try if communication failed; fail -to
communicate output; one or two phone lines option; up
to four phone number capability (plus computer phone
for downloading); Touch -Tone and rotary compatible.
The 5207 is compatible with all major reporting
formats including SIA (security industry standard), SK,
FSK, SK 4/2, Radionics BFSK. Format selectable by
account number.
SPECIFICATIONS
ELECTRICAL SPECIFICATIONS:
• Primary AC: 120 VRMS at 60 HZ, 2A
• Total Accessory Load: 5A at 24 VDC
6A at 12 VDC
INDICATOR LIGHTS:
• AC/DC POWER (Green) - On when system is running
on AC power; flashes when using DC.
• ALARM (Red) - On for supervisory alarm; flashes for
fire alarm.
• TROUBLE (Yellow) - On when trouble condition exists.
• SILENCED (Yellow) - On when alarm or trouble has
been silenced but not yet cleared.
• EVENT MEMORY (Yellow) - On when an alarm
condition has been reset.
• SET MODE/REPORT (Yellow) - On when system is in
test or program mode, including Date/Time set mode.
Flashes when system is reporting.
MECHANICAL SPECIFICATIONS:
• Dimensions: 16 in. W x 26.4 in. H x 4 in. D
(40.6cm W x 67cm H x 10.2cm D)
• Weight: 25 lbs. (11.4 kg.)
• Color: Red
TELEPHONE REQUIREMENTS:
• FCC Registration No.: AC6USA-65475-AL-E
• Type of Jack: RJ31X (2 required)
APPROVALS:
• UL Listed
• FM Approved
• CFM Approved
• New York City MEA (formerly BSA)
• NFPA - Central Station Reporting
- Local Protective Signaling System
- City Box
- Polarity Reversal
- Proprietary Protective Signaling System
OPTIONAL ACCESSORIES
Model 4180 Status Display Module
Provides 16 outputs to give alarm and trouble conditions
by zone. Two units can be connected to annunciate all
16 zones on a 5207 control. Can be used to drive LED
or graphic annunciators. (Non -supervised)
Model 7181 Fire Zone Convertor
Converts Style A zones to Style D and vice versa.
1.; 16401.9 @baser@
5220 Direct Connect Module
Used for City Box and polarity reversing direct
wire applications.
• • T
5530 Downloading Modem
SIA format modem for remote programming of 5207.
5541 Downloading Software
For remote programming with IBM PC and compatible
computers. Can be used with 5207. Requires 5530
modem. Software/modem package may be ordered
as a 5561.
5260 Printer Interface
Allows connection of a standard computer printer to
provide a printed record of 5207 system activity. Simple
plug-in connection. (Printer not supplied.)
ARCHITECT/ENGINEER SPECIFICATIONS
The contractor shall provide a complete electrically supervised
fire alarm and communications system. The system shall
contain a fire alarm control/communicator and panel to
supervise and operate heat and smoke detection devices,
alarm signal devices, visual annunciators and an integral
digital communicator to transmit fire alarm and supervisory
signals to a central station. The control/communicator shall be
UL Listed or FM approved for use under NFPA 71, 72A, 7213,
72C and 72D standards. It shall provide power and control for
eight supervised detection zones, foursupervised alarm signal
circuits and a dual digital communicator. The control/
communicator shall be expandable to sixteen supervised
detection zones and shall be able to communicate to a central
station in SIA, SK FSK1, SK 4/2 or Radionics BFSK formats.
The control/communicator shall be Model 5207 or
approved equal.
There shall be two Style D and six Style A detection zones.
They shall accommodate heat detectors, products of
combustion detectors, manual pull stations, sprinkler flow
switches and gate valve supervisory switches intermixed as
desired and permitted by NFPA 71, 72A, 7213, 72C, and 72D.
Products of combustion detection may be either two- or four -
wire and shall be cross listed by UL for use on the system. The
detection zones shall be programmed to (1) be cross zoned so
that two individual zones must sense products of combustion,
(2) automatically reset a detector to verify that smoke exists,
(3) see a single detector in alarm —before the alarm is sounded
and a signal is transmitted to the central station.
There shall be four 1 amp supervised (Style Y) alarm signal
circuits. They shall cause the bells/horns to ring steady/
pulsing/temporal throughout the premises until reset or
silenced. Two 1 amp outputs can be combined to provide one
2 amp output.
The control shall be equipped with four auxiliary relays that
L.. •1 , ' 1L LM d
��.
If Ni -
I wed 1 IMS -) -
Imc L1O.LSL1I
shall be programmed to operate on (1) pre -alarm, (2) tamper
alarm, (3) special alarm, (4) fire alarm, (5) trouble, (6) no -
silence, (7) alarm by specific zone (1-16). The relays shall
remain energized until the panel is silence reset or the trouble
condition is cleared, unless "no -silence" is selected.
The control/communicator shall have an integral annunciator
to indicate sequentially zones in alarm, zones in trouble, and
system functions. LEDs shall augment the display to make
clear to an operator the system status. An integral touchpad
shall be provided to operate, set up, and interrogate the
system. Vital operations such as alarm silencing or reset shall
be simple and obvious to an operator. Authorization pass
codes may or may not be used.
The control/communicator shall have the capability to supervise
two telephone lines, seize the phone line, and send the alarm
signal on one or both lines without the addition of any more
equipment. It shall sound a local trouble signal if the telephone
service is interrupted for longer that 45 seconds and it shall
transmit a signal indicating the loss of phone line service to the
central station over the remaining phone line. A signal shall
also be transmitted indicating the restoral of phone service.
The control/communicator shall be able to report the loss of
either phone line without regard to which phone line failed first.
If both lines fail, a local signal shall sound.
The control/communicator shall have the ability to send a test
signal to the central station every 24 hours. The test signal
shall be able to be transmitted at a specific time of day or night
by setting a program within the panel.
The alarm signals transmitted to the central station shall
indicate which of the eight zones is in alarm and which zones
are in trouble, depending on which format is used. Restoral
from alarm or trouble shall also be transmitted by zone. The
control/communicator shall be capable of communicating to
Silent Knight, Radionics orAdemco central station receivers.
iL0.'I u�M,N�
�[K4 b24� •�na
ar[ toyrna F+4 c,urn
�Xp
COYW N"IW L w L�XF.Y
.GLf� 5:L
---
MODEL 5207 BLOCK DIAGRAM - TYPICAL INSTALLATION
7750 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN
SILENT
1-800-446-6444 or in Minnesota (612) 493-6435 AMERICA
KNIGHT FAX: (612) 493-6475
Form #150376 (Rev 9/96)
13FIRE SYSTEMS®
mow► w' ES-4�
,fSECURITY
CORPORATION INNOVATION
7707 Fire Subscribers
IntelliNet
Introducing a Newer,
Smarter Alarm
aes-corp.com
NEW COMMUNICATOR
Communications Platform
New Feature Highlights
• Leverages state of the art technology
• Applies advanced security protection
• Offers flexible power and configuration options
• Engineered for backward compatibility with legacy systems
• Enables future ready capabilities
• Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD
display, and Menu/Silence button
• Improves functionality with an adaptive Graphic User Interface (GUI) for programming via
smartphones, tablet and PCs
• Plus many more...
no u1
NFPA' LISTED
Key Benefits that Make 2.0 the Best Alarm Monitoring Solution Ever
• Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private
licensed wireless networks
• Protects subscriber units against unauthorized access and rogue activity with a password protected
Dealer Code
• Makes programming and streamlined troubleshooting easy with user friendly interface
• Adds integrated supervision of AES-IntelliPro full data module
• Provides versatile power options:
(1) Direct from the Fire Alarm Control Panel (FACP) without requiring an electrician onsite and without
Subscriber backup battery
(2) Directly from the FACP with Subscriber backup battery; or
(3) Traditional installation with plug in Class 2 low power transformer
• Allows for enhancement upgrades and an expanded number of new features to be added easily with
highly flexible and scalable alarm communications infrastructure
• Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and
UL standards
Enhanced Wireless Fire Alarm Monitoring
Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation
universal wireless communicators that provide advanced security protection for any new or existing alarm
monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data
module option, they are the ideal drop -in replacement for Plain Old Telephone Service (POTS) lines.
The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides
an instant visual of the subscriber status. The user friendly GUI makes it easy to program AES subscriber units
via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or
having to use a handheld programmer. Additional knockouts make it easier to mount for faster installation.
IntelliNet 2.0 Private Wireless Mesh Radio Network
°] Burglary ° _
Subscriber -—-—- —— — — — — ——
+mt B
r I
�I, I �
ej Fire r r I
Subscriber I I
I r AES•Nelwerk MoiwBemene System
----- °
B — — — — — ' ' — _ Primary AES-MWMIt Rt ,Nl,
1 I
Ay Alarm I I I
Panel I r Secondary AE S•MuIfINet Receluer
I
B I ' B •C Alarm Automation
A -
�——————— — —— — —— QIPLinks
Customer Location Mesh Radio Technology I Central Monitoring Station
Alarrn panel & AES Subscriber Multi -Path AES-7rrlel iNel® Network Primary & Secondary AES-MuldNe1 Syslern
sends critical evern signal delivers alarm signals via smart routing, receives transmission in 1-3 seconds
The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity,
POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add -on accessory board.
AES subscribers' intelligent software automatically detects new hardware and devices to reduce installation time.
An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming. A
laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers
will not work with 2.0 units. The forward compatible design allows for feature add-ons, engineered to adapt
seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for
faster installation time.
The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians
to get in, out, and on to the next install.
Visit our Fire Marshal Resources web page for official NFPA and UL Listings:
http://aes-corp.com/products/fire/fire-marshal-resources/
How to Order
7707 Fire
IntelliNet 2.0 Fire Subscribers
2.0 PREMIUM (UL & ULC Listed, Available Now!)
IntelliNet 2.0 Fire Subscriber, 8 Zone, 8 Supervised Zones, with integrated onboard
7707P-88
Local Annunciator, Red Enclosure
IntelliNet 2.0 Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794AAES-IntelliPro
7707P-88-ULP
and integrated onboard Local Annunciator, Red Enclosure
IntelliNet 2.0 Fire Subscriber, 4 Zone, 4 Supervised Zones, with integrated onboard
7707P-44
Local Annunciator, Red Enclosure
IntelliNet 2.0 Fire Subscriber, 4 Zone, 4 Supervised Zones with 7794A AES-IntelliPro
7707P-44-ULP
and integrated onboard Local Annunciator, Red Enclosure
2.0 FEATURE ADD (Pending UL Review)
IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies
7707P-88-M
(MCT), Red Enclosure
IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated
7707P-88-ULP-M
onboard Local Annunciator plus MCT, Red Enclosure
IntelliNet 2.0 Fire Subscriber, 4 Zone with Multiple Communication Technologies
7707P-44-M
(MCT), Red Enclosure
IntelliNet 2.0 Fire Subscriber, 4 Zone with 7794A AES-IntelliPro, and integrated
7707P-44-ULP-M
onboard Local Annunciator plus MCT, Red Enclosure
7707M-UPG
IntelliNet 2.0 Fire MCT Software Upgrade
2.0 ACCESSORIES
Standalone AES-IntelliPro Fire full data module add -on accessory board with
7794A
firmware for new IntelliNet 2.0 units only, cannot be used in legacy units
77-WiFi
AES certified WiFi adapter
Legacy• •-
7706-ULF
Integrated Fire Monitoring System, Red Enclosure
Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro (7794 full data module,
7788F-ULP-P
7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure
Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro,
7788F-ULP
Red Enclosure
7788F
Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure
Legacy Fire Subscriber, 4 Zone with 7795 AES-IntelliPro (7794 full data module,
7744E-ULP-P
7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure
Legacy Fire Subscriber, 4x4 Zone, 4 Supervised Zones with 7794 AES-IntelliPro,
7744F-ULP
Red Enclosure
Legacy Fire Subscriber, 4x4 Zone, 4 Reversing Polarity, 4 Supervised Zones,
7744F
Red Enclosure
LEGACY ACCESSORIES
Standalone AES-IntelliPro Fire full data module add -on accessory board for legacy
7794
units only, please see 7794A above for IntelliNet 2.0 version
Technical Specifications
7707 Fire
DIMENSIONS
13"H x 8.5"W x 4.5"D
(33cmH x 21.5cmW x 11.4cmD)
WEIGHT
5.8 Ibs (2.6 kilograms)
excluding battery
13 Ibs (5.9 kilograms) with
10 Ah battery
RADIO FREQUENCY
Standard Frequency Range:
450-470 MHz
Contact AES for other UHF
and VHF frequencies
ANTENNA
2.5 dB tamper resistant antenna
included, mounts on enclosure
Optional remote mounting
antenna available
POWER INPUT
AC SOURCES
Class 2 transformer
40VA, 120V AC primary
ELK ELK-TRG1640, MG Electronic
Sales MGT1640, and AES 1640 are
UL Listed for use (not included)
1.75A, maximum input
current value
16.5V AC, nominal output value
DC SOURCES
External regulated power supply,
24V DC, rechargeable backup
battery in Subscriber
1.3A, input current
Regulated power supply from FACP
AUX power, 24V DC, UL Listed FACP
with backup battery in FACP
1.3A, input current
Contact Us
BACKUP BATTERY
10-12 Ah, UL recognized lead acid
gel cell, size based on subscriber
configuration
ALARM SIGNAL INPUTS/ZONES
8 individually programmable
E.O.L. type zone inputs
4+4: 4 reverse polarity input and
4 individually programmable
E.O.L. type zone inputs
Optional 7794A AES-IntelliPro for
full data via Contact ID, Pulse,
Modem Ile and Modem IIIa2
UL LISTINGS
UL 864 loth Edition
Standard for Control Units and
Accessories for Fire Alarm Systems
ULC S559-04 1st Edition
Equipment for Fire Signal
Receiving Centres and Systems
TROUBLE OUTPUT—ACK
DELAY/ANTENNA CUT
Form C relay, fail secure, rated 24V
DC 1A resistive
RESET BUTTON
Located on main circuit board
OPERATING TEMPERATURE
32 to 120OF (0 to 49°C)
STORAGE TEMPERATURE
14 to 140OF (-10 to 60°C)
RELATIVE HUMIDITY
0 to 93%, non -condensing
RECHARGE CAPABILITY
Will charge 12V battery size
from 10-12 Ah
PORTS
Ethernet for configuration and
communication
USB access for
software upgrade
REMOTE ANNUNCIATOR
AES Model 7740
Remote Annunciator, supervised
COMPATIBLE RECEIVERS
7705i AES-MultiNet Receiver
CONFIGURATION INTERFACE
Web browser capable device
accessible via smartphone, tablet,
laptop, or PC
CURRENT CONSUMPTION
Standby with charged backup
battery: 175 mA
Standby + charging backup battery:
200 mA
Transmitting: 1.2 A (typical
transmission is 1/3 second length)
POWER OUTPUT
2 or 5 Watts
Factory set
ENCLOSURE MATERIAL
Steel with paint finish
FINISH COLOR
Red
VISUAL INDICATORS
Front panel LCD
(2 x 20 alphanumeric character
backlit display)
Power and Trouble LEDs
(ALM Trouble Tx, Rx, WA)
For pricing and availability or to learn more about IntelliNet 2.0, please call your local
AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com.