Loading...
REVIEWED BLD-BLD2021-0758+Calculations+6.3.2021_11.29.57_AM+2230298RECEIVED Jun 04 2021 SERVICES BLD2021-0758 ALBERT H. COHEN DESIGN COMPANY, P.S. 330 Dayton Street Suite 6 Edmonds, Washington 98020 425-776-7373 GRAVITY LOAD DESIGN ANALYSIS FOR Schroeder Residence 817 - 7th Ave North Edmonds WA 98020 DESIGN LOADS Roof Live 25 PSF (SNOW), Dead 13 PSF, "Total 38 PSF Floor Live 40 PSF, Dead 10 PSF, Total 50 PSF Sleeping Areas Live 30 PSF, Dead 10 PSF, Total 40 PSF Deck and Balcony Live 60 PSF, Dead 10 PSF, Total 70 PSF 5496 REGISTERED ARCHITECT ALBERT H. COHEN STATE OF WASHINGTON PREPARED 6/2/2021 REVIEWED BY CITY OF EDMONDS € n I DEPARTMENT .......... . . . . . . . .. .L .......................... Albert H Cohen Design Company 330 Dayton St. Suite 6 Edmonds, WA 98020 425-776-7373 BeamChek v2020 licensed to: Albert H Cohen Design Company Reg # 3145-68876 SCHROEDER RESIDENCE DECK BEAM BEAM A Prepared by: AHC Date: 5/27/21 Selection PT 6x 12 DF-L #1 Lu = 0.0 Ft Conditions NDS 2018, Wet Use, Incised Min RParina Area R1= 7.4 in R2= 7.4 in (2.0) DL Defl= 0.07 in Data Attributes Actual Critical Status Ratio Values Adjustments Loads Beam Span 11.5 ft Reaction 1 LL 2588 # Reaction 2 LL 2588 # Beam Wt per ft 15.37 # Reaction 1 TL 3107 # Reaction 2 TL 3107 # Bm Wt Included 177 # Maximum V 3107 # Max Moment 8933'# Max V (Reduced) 2589 # TL Max Defl L / 240 TL Actual Defl L / 590 LL Max Defl L / 360 LL Actual Defl L / 827 Section (in') Shear (in') TL Defl (in) LL Uen 121.23 63.25 0.23 0.17 99.26 28.56 0.58 0.38 OK OK OK OK 82% 45% 41% 44% Fb (psi) Fv (psi) E (psi x mil) Fc! (psi) Reference Values 1350 170 1.6 625 Adjusted Values 1080 136 1.5 419 CF Size Factor 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet+Ci Incised 0.80 0.80 0.95 0.67 Cl Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Uniform LL: 450 Uniform TL: 525 = A Uniform Load A R1 = 3107 R 2 = 3107 SPAN =11.5FT Uniform and partial uniform loads are Ibs per lineal ft. Albert H Cohen Design Company 330 Dayton St. Suite 6 Edmonds, WA 98020 425-776-7373 BeamChek v2020 licensed to: Albert H Cohen Design Company Reg # 3145-68876 SCHROEDER RESIDENCE DECK JOISTS BEAM B Prepared by: AHC Date: 5/27/21 Selection PT 2x 12 HF #2 @ 12 in oc Lu = 0.0 Ft Conditions NDS 2018, Repetitive Use, Wet Use, Incised Min Raarinn Area R 1 = 1.9 in R2= 1.9 in (2.0) DL Defl= 0.10 in Data Attributes Actual Critical Status Ratio Values Adiustments Loads Beam Span 14.5 ft Reaction 1 LL 435 # Reaction 2 LL 435 # Beam Wt per ft 0 # Reaction 1 TL 508 # Reaction 2 TL 508 # Bm Wt Included 0 # Maximum V 508 # Max Moment 1840'# Max V (Reduced) 442 # TL Max Defl L / 240 TL Actual Defl L / 433 LL Max Defl L / 360 LL Actual Defl L / 578 Section (in3) Shear (in 2) TL Defl (in) LL Uen 31.64 16.88 0.40 0.30 28.23 5.69 0.73 0.48 OK OK OK OK 89% 34% 55% 62% Fb (psi) Fv (psi) E (psi x mil) Fc 1 (psi) Reference Values 850 150 1.3 405 Adjusted Values 782 116 1.1 271 CF Size Factor 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.15 Ch Shear Stress N/A Cm Wet+Ci Incised 0.80 0.776 0.855 0.67 Cl Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Uniform LL: 60 Unitorm I L: ru = H Uniform Load A R1 = 508 R2 -�508 SPAN =14.5FT Uniform and partial uniform loads are Ibs per lineal ft.