Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD2017-0550 REMAINING INSPECTIONS_762795170
RECEIVED NEW PERMIT: Aug 16 2022 BLD2022-1023 CITY OF Inspection Results DEVELOPMENT SEDMOERVCES DEPARTMENT flow 121 5th Ave, Edmonds Washington - Phone: (425) 771-0220 PERMIT ID: BLD20170550 REVIEWED Type: 02 - Addition BY Address: 1140 7TH AVE S, EDMONDS Parcel: 00619400800300 CITY OF E D M O N D S Contact: TYLER & CATHERINE KIMBROUGH 1077 - E-Engineering Final 1112 - B-Foundation Drainage 1114 - B-Isolated Footings/Piers 1146 - B-Insulation/Energy 1158 - B-Building Final 1001 - E-Erosion Control/Mobilization INSPECTED DATE: 08/09/2017 INSPECTOR: RIVERA COMMENT: Erosion control is adequate at this time. 1101 - B-Preconstruction meeting INSPECTED DATE: 08/07/2017 COMMENT: 1106 - B-Setbacks INSPECTED DATE COMMENT: 1108 - B-Footings INSPECTED DATE COMMENT: 08/28/2017 Per survey. INSPECTOR: LAWLER INSPECTOR: DGARRISON 09/06/2017 INSPECTOR: DGARRISON All areas except at garage door left side and retaining wall per A.2.2. INSPECTED DATE: 08/28/2017 COMMENT: Columns and patio. 1110 - B-Foundation Wall INSPECTOR: DGARRISON PERMIT STATUS: tS6tkff)-- Applied: 04/25/2017 Issued: 07/18/2017 Expires: 07/18/2020 Final: INSPECTION COMPLETE: NO INSPECTION COMPLETE: NO INSPECTION COMPLETE: NO INSPECTION COMPLETE: NO INSPECTION COMPLETE: NO INSPECTION COMPLETE: NO ACTION: PARTIAL INSPECTION INSPECTION COMPLETE: YES ACTION: INSPECTION COMPLETE INSPECTION COMPLETE: YES ACTION: INSPECTION COMPLETE INSPECTION COMPLETE: NO ACTION: PARTIAL INSPECTION ACTION: PARTIAL INSPECTION INSPECTION COMPLETE: YES 7/20/2022 11:50:33 AM Page 1 of 4 INSPECTED DATE: 08/15/2018 INSPECTOR: MTHOMPSON COMMENT: Approved INSPECTED DATE: 09/12/2017 INSPECTOR: DGARRISON COMMENT: Retaining wall at back porch. INSPECTED DATE: 09/06/2017 INSPECTOR: DGARRISON COMMENT: Back and front except retaining wall per A.2.2. INSPECTED DATE: 08/28/2017 INSPECTOR: DGARRISON COMMENT: Partial at back. 1126 - B-Plumb Rough In INSPECTED DATE: 09/04/2018 INSPECTOR: ECARTER COMMENT: Approved INSPECTED DATE: 12/29/2017 INSPECTOR: MTHOMPSON COMMENT: Under ground basement bath ok to cover 1128 - B-Gas Test/Pipe INSPECTED DATE: 11/02/2018 INSPECTOR: MTHOMPSON COMMENT: Approved with Gas Pipe Test Affidavit 1130 - B-Mechanical Rough In INSPECTED DATE: 11/09/2018 INSPECTOR: MTHOMPSON COMMENT: Approved 1132 - B-Exterior Wall Sheathing INSPECTED DATE: 09/06/2018 INSPECTOR: ECARTER COMMENT: Approved INSPECTED DATE: 09/05/2018 INSPECTOR: ECARTER COMMENT: Partial, back of of the house under the co reed deck only INSPECTED DATE: 02/13/2018 INSPECTOR: MTHOMPSON COMMENT: All except above and below deck in back of the house INSPECTED DATE: 02/07/2018 INSPECTOR: MTHOMPSON COMMENT: Check and re -nail per shear wall schedule ACTION: INSPECTION COMPLETE ACTION: PARTIAL INSPECTION ACTION: PARTIAL INSPECTION ACTION: PARTIAL INSPECTION INSPECTION COMPLETE: YES ACTION: INSPECTION COMPLETE ACTION: PARTIAL INSPECTION INSPECTION COMPLETE: YES ACTION: INSPECTION COMPLETE INSPECTION COMPLETE: YES ACTION: INSPECTION COMPLETE INSPECTION COMPLETE: YES ACTION: INSPECTION COMPLETE ACTION: PARTIAL INSPECTION ACTION: PARTIAL INSPECTION ACTION: CORRECTION NOTICE 7/20/2022 11:50:33 AM Page 2 of 4 1133 - B-Roof Sheathing INSPECTED DATE: 06/18/2018 INSPECTOR: MTHOMPSON COMMENT: Approved INSPECTED DATE: 06/18/2018 INSPECTOR: MTHOMPSON COMMENT: Approved 1135 - B-Window Flashing INSPECTED DATE: 06/18/2018 INSPECTOR: MTHOMPSON COMMENT: Approved 1136 - B-Shear Nailing INSPECTED DATE: 09/05/2018 INSPECTOR: ECARTER COMMENT: Retrofit hold downs approved 1140 - B-Height Verification INSPECTED DATE: 11/09/2018 INSPECTOR: MTHOMPSON COMMENT: Need new letter INSPECTED DATE: 11/02/2018 INSPECTOR: MTHOMPSON COMMENT: Rewrite letter to show max height and actual height 1142 - B-Framing INSPECTION COMPLETE: YES ACTION: INSPECTION COMPLETE ACTION: INSPECTION COMPLETE INSPECTION COMPLETE: YES ACTION: INSPECTION COMPLETE INSPECTION COMPLETE: NO ACTION: PARTIAL INSPECTION INSPECTION COMPLETE: NO ACTION: CORRECTION NOTICE INSPECTION COMPLETE: YES INSPECTED DATE: 11/09/2018 INSPECTOR: MTHOMPSON ACTION: INSPECTION COMPLETE COMMENT: Approved INSPECTED DATE: 11/05/2018 INSPECTOR: MTHOMPSON ACTION: CORRECTION NOTICE COMMENT: 1. Strap beam to beam and A35 upper beam to beam 2. Basement bedroom strap post to beam on West end. Provide an A35 East end with 16 gauge strap on cut plates 3. Fire block furred wall in laundry room 4. Ok to insulate INSPECTED DATE: 11/02/2018 INSPECTOR: MTHOMPSON ACTION: CORRECTION NOTICE COMMENT: 1. Seal all penetrations in top and bottom plates 2. Fire block above fridge cubby 3. Provide truss uplift connections 4. Strap top plate at heat duct master bath 5. Strap post to beam at master bedroom door 6. Fire block all soffits in basement 7. Have approved plans on site and organized 1144 - B-Wall Insulation/Caulk INSPECTION COMPLETE: YES 7/20/2022 11:50:33 AM Page 3 of 4 INSPECTED DATE: 11/09/2018 INSPECTOR: MTHOMPSON ACTION: INSPECTION COMPLETE COMMENT: Approved 1150 - B-Sheetrock Nail INSPECTION COMPLETE: YES INSPECTED DATE: 11/13/2018 INSPECTOR: ECARTER ACTION: INSPECTION COMPLETE COMMENT: Approved 7/20/2022 11:50:33 AM Page 4 of 4