APPROVED PLN BLD BLD2021-1507+Site_Plan+10.20.2021_12.34.42_PM+2473833A C E F G H J L M I N 2 J 4 5 0 7 MITSUBISHI ELECTRIC TRANE HVAC US: CITY MULTI VRF OUTDOOR UNIT SCHEDULE System Tag Tag Reference M-Net Address Model Number Modules Nominal Cooling Capacity (BTU/h) Nominal Heating Capacity (BTU/h) Cooling Efficiency IEER/EER [SEER] Heating COP @ 47°F [HSPF] Nom System Connected Capacity (% of NOM) Design Cooling Outdoor Temp DB (°F) Design Heating Outdoor Temp WB (°F) Retig Pipe Dim High/Low Pressure (inch) (See Note 4) Corrected Cooling Total Capacity (BTU/h) Corrected Heating Capacity (BTU/h) Sound Pressure (dBA) Electrical -Per Module Notes / Options 208/230 or [460V] Voltage / Phase MCA 208/230 or [460V] RFS MOCP System 1 CU-1 N/A MUZ-GL09NA-Ul 9,000.0 10,900.0 [24.60000038146 97] [12.8] 100.0% 85.0 20.2 1/4/3/8 9,821.9 9,264.1 48/50 208/230V / 1- phase 9 15 15 1, 2, 3, 4, 5 Notes & Options: 1 Nominal cooling capacities are based on indoor coil EAT of 80/67'F (DBIWB), outdoor of 95°F (DB) 2 Nominal heating capacities are based on indoor coil EAT of 70°F (DB), outdoor of 43°F (WB) 3 Efficiency values for EER, IEER, COP are based on AHRI 1230 test method for mixture of ducted & non -ducted indoor units. 4 For systems with multiple modules, refrigerant pipe dimensions indicate total system combined piping downstream of module twinning. 5 Added field charge listed is in addition to factory charge, this must be updated based upon final as -built piping layout. MITSUBISHI ELECTRIC TRANE HVAC US: CITY MULTI VRF INDOOR UNIT SCHEDULE Cooling Design Entering Temp Heating Design Entering Temp Corrected Capacity Refrig Pipe Dim Peak Fan Airflow Max Fan ESP Setting Sound Pressure Per Fan Speed Cooling Diversity Heating Diversity Nominal Cooling Nominal Heating DB/WB ff) / DB/WB ff) / Full/Partial (See Cooling Total Cooling Sensible Full/Partial (See Heating Capacity LiquidiSuction (cf-n) i [Design 208V/230V (IN 208V/230V Power Cooling Power Heating Electrical System Tag Room Name Tag Reference Model Type Capacity (BTU/h) Capacity (BTU/h) [Water in temp] [Water in temp] Note 5, 6) Capacity (BTU/h) Capacity (BTU/h) Note 5, 6) (BTU/h) (inch) gpm G(US)/min] WG) (dBA) Voltage / Phase 208V/230V (kW) 208V1230V (kW) MCA/MFS Notes / Options 19-22-30-37- Elevator Machine 43/19-22-30-37- 208/230V/1- Powered by System 1 Room FU-1 MSZ-GL09NA-Ul Wall -Mounted 9,000.0 10,900.0 80.0/67.0 70.0 FULL DEMAND 9,821.9 8,316.1 FULL DEMAND 9,264.1 3/8 / 1/4 406 43 phase Outdoor 1, 2, 3, 4, 5, 6 Notes & Options: 1 Nominal cooling capacities are based on indoor coil EAT of 80/67°F (DB/WB), outdoor of 95°F (DB) 2 Nominal heating capacities are based on indoor coil EAT of 70°F (DB), outdoor of 43°F (WB) 3 See outdoor unit schedule for outdoor ambient conditions, connected capacity, and other factors associated with corrected capacities 4 See schematic piping/control diagram for indication of required indoor unit remote controllers, system controllers, and integration devices. 5 Full demand corrected capacity includes de -rate associated with indoor vs. outdoor connected capacity indicated on outdoor unit schedule for associated system. Partial corrected capacity assumes sufficient diversity exists such that the connected capacity de -rate does not apply. It is the designer's responsibility to ensure "Diamond System Builder" is set in the appropriate output capacity setting (full demand!partial demand) prior to generating this schedule. 6 It is recommended to always base heating corrected capacity on full demand. PARKING COMMONS COMMONS 0 RESTROOM SHOWER COURTYARD CORRIDOR SAUNA MECHANICAL PARKING 9 LOWER LEVEL MACHINE ROOM MECH PLAN SCALE: 1 /8" = 1' W COMMONS COURTYARD LOBBY STAIR 50, 1 TO SW PUGET DR ELEVATOR MACHINE RM PARKING MOUNT INDOOR UNIT AT T AFF. SEAL ALL LINESET PENETRATIONS IN MR AND COURTYARD WALL WITH APPROVED LUMINESCENT FIRE STOP. LINESET WILL LINE HIDE WHERE VISIBLE INDOORS ELECTRICAL RESIDENT STORAGE OUTDOOR UNIT TO BE MOUNTED ON CONCRETE WALL COURTYARD AT V ABOVE GRADE. COURTYARD GRADE WELL BELOW STREET AND SIDEWALK GRADE. HEDGE F AND TREES AT STREET LEVEL COMPLETELY BLOCK VIE ENTIRE COURTYARD AND PROPOSED OUTDOOR UNIT F FOOT AND STREET TRAFFIC. OUTDOOR UNIT LOCATION VISUAL FROM STREET SCALE: N/A 2 City Of Edmonds Building Department Work MECHANICAL Address 1414 9TH AVE N Owner SUNDSTONE CONDOS Approved Date 11 /10/2021 Rllildinn C)ffirial Er & Cvi4rhw Permit Number BLD2021-1507 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PI.ANS MUST BE ONJOB SITE SCOPE OF WORK: FOR THE PURPOSE OF ELEVATOR MODERNIZATION: INSTALL SPLIT UNIT AIR CONDITIONING FOR THE EXISTING ELEVATOR MACHINE ROOM. SIZE THE UNIT FOR PROPER COOLING AND AS STATED ON THE EQUIPMENT SCHEDULE. INSTALL CONDENSER UNIT EQUIPMENT WALL MOUNTED IN THE COURTYARD BUILDING EXTERIOR PER THIS PLAN. ENERGY CODE ECONOMIZER C403.5 EXCEPTION 11 TAKEN. MECHANICAL CODE: 2018 KEY LEGEND AND COMPONENT LIST SYMBOL DESCRIPTION QTY PART # MANUFACTOR MOUNTING SPEC EXIS NEW CONDENSER UNIT MUZ-GL09NA-U1 MITSUBISHI WALL MOUNT ROOF LEVEL FU-1 INDOOR FAN UNIT MSZ-GL09NA-U1 MITSUBISHI 7'AFFTO BOTTOM LINE SET 18, 3/8" / 1/4" 3/8" / 1/4" CONDENSATE DRAIN 18, 5/8" TUBING FROM FAN UNIT CONDENSATE PUMP 554530 LITTLE GIANT AT INDOOR FAN UNIT 0 5' 10' 20' 30' GRAPHIC SCALE 4 ro� a5pers 5t .sr qu N"EerL� We Iody Ln 5Z4 b ftt& S[ c m �Dr per+ L n i Pugett414 9fth Ave Pugec Way N 524 �VICINTY MAP SCALE: NOT TO SCALE APPROVED BY PLANNING 11 / 17/2021 X �o��ii rl JTY Blake PI o�. A :w 192nd 5t SW o L cx b1 A 5. U C ¢+ Ft 524 Q 3 Virwland )m sY 196th St SW 5$4 e M a4�� . V 0 200th St SW Z o m > cn w CE i5 Ir w o_ 0 z > O w W N H OCO Q N � O 0 0 N Q co -JO((o J = 0 U) N 0� -.> co co t `O U O N T- w CO J X wm O D- CL O I-- r, Q cc H- z O U z O O Q N z w 0 0 0 z 00 V ErwM W oQ� J Z O-) C) O w It z r O I".ft O2 ♦ /� LL 0 r♦ —.1a U_ LU Z Q co Cw G RECEIVEID Nov 04 2021 CITY OF EDMONDS Cr DEVELOPMENT SERVICES w DEPARTMENT o_ O U) z m m z w 6i a z w z 07 w APPROVED BY: ER DRAWN BY: ER DATE: 10/20/21 JOB# SUNDSTONE DWG. NO.: M-01