Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD2021-1507+Manufacturer_Specifications_and_Installation_Instructions+10.20.2021_12.34.59_PM+2473835
TV AkNUSUBSK k R -,TW Changes for the Seller Project Name: Project Number: Comment: REVIEWED BY CITY OF EDMONDS Sundstone Condos Sundstone Edmonds HVAC for elevator modernization BLD2021-1507 RECEIVED Nov 04 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 4.1.1.1 Mk:iubisld ELcclrie Di—d5yM—gui Id.1 10)J2}120xx 0ii21 V.LL All, MITSUBISHI ELECTRIC US, Inc. WHI r-1 TF ariges for the Setter Table rf Contents UnitQuantities.......................................................................... 1 SystemImages.......................................................................... 2 Centralized System - 1, System 1 Equipment Detailed Schedules ............................................... 3 Outdoor Unit Schedules Indoor Unit Schedules Equipment Submittals.............................................................. 4 MIT UBI HI ELECTRIC I US, Inc. Quantities -F Model M1 stock controller ` 1 MUZ-GL09NA-U1 Nk1 MSZ-GL09NA-U1 Description Wireless remote controller R410A MandS Series Outdoor Unit Wall -Mounted Indoor Unit Refrigerant Piping Materials WNumber of Bends 18 _- 4 _ 18 _- 4 Price Included with Indoor Unit Centralized System - 1 : System 1 Piping Diagram Image (Design View) MUZ GLfl9NA-U1 Model Number Pipe Qia_ Liquid f Gas �� Glg_Total (Sens_) Pipe Length (Elbows) Htg_Total Group ! RuQm f Tag Ref. MSZ-GL09NA-U 1 9.822 BTUlh 6.316 BTU1h Est Cooling Discharge Air Tem 60.7 114 f 3!8 � ) 9 r9 P� n y 18 Oft ( 4 ) 9.264 BTUlh Est Heating Discharge Asir Temp= 91.2 NIA f 1 f Elevator Machine Room f FU-1 MITSUBISHI ELECTRIC TRANE HVAC US: CITY MULTI VRF OUTDOOR UNIT SCHEDULE System Tag Tag Reference M-Net Address Model Number Modules Nominal Cooling Capacity BTU/h Nominal Heating Capacity BTU/h Cooling Efficiency IEER/EER SEER Heating COP @ 47°F HSPF Nom System Connected Capacity (% of NOM Design Cooling Outdoor Temp DB °F Design Heating Outdoor Temp WB °F Refrig Pipe Dim High/Low Pressure (inch) See Note 4 Corrected Cooling Total Capacity BTU/h Corrected Heating Capacity BTU/h) Sound Pressure (dBA) Electrical -Per Module Notes / Options 208/230 or 460 Voltage/ Phase MCA 208/230 or 460V) RFS MOCP System 1 CU-1 N/A MUZ-GL09NA- U1 9,000.0 10,900.0 [24.60000038146 97] [12.81 100.0 % 85.0 20.2 1/4/3/8 9,821.9 9,264.1 48/50 208/230V / 1- phase 9 15 15 1,2 3, 4, 5 Notes & Options: 1 Nominal cooling capacities are based on indoor coil EAT of 80/67°F (DB/WB), outdoor of 95°F (DB) 2 Nominal heating capacities are based on indoor coil EAT of 70°F (DB), outdoor of 43°F (WB) 3 Efficiency values for EER, IEER, COP are based on AHRI 1230 test method for mixture of ducted & non -ducted indoor units. 4 For systems with multiple modules, refrigerant pipe dimensions indicate total system combined piping downstream of module twinning. 5 Added field charge listed is in addition to factory charge, this must be updated based upon final as -built piping Iayou MITSUBISHI ELECTRIC TRANE HVAC US: CITY MULTI VRF INDOOR UNIT SCHEDULE Cooling Design Entering Temp Heating Design Entering Temp Corrected Calpaci Refrig Pipe Dim Peak Fan Airflow Max Fan ESP Setting Sound Pressure Cooling Diversity Heating Diversity Nominal Cooling Nominal Heating DB/WB (°F) / DB/WB (OF) / Full/Partial (See Cooling Total Cooling Sensible Full/Partial (See Heating Capacity Liquid/Suction (cfm) / [Design 208V/230V (IN Per Fan Speed Power Cooling Power Heating Electrical System Tag Room Name Tag Reference Model Type Capacity BTU/h Capacity BTU/h [Water in temp] [Water in temp] Note 5, 6 Ca aci BTU/h Capacity BTU/h Note 5, 6 BTU/h inch m G US /min WG 208V/230V (dBA) Voltage / Phase 208V/230V kW 208V/230V kW MCA/MFS Notes / Options 19-22-30-37- Elevator Machine 43/19-22-30-37- 208/230V/1- Powered by System 1 Room FU-1 MSZ-GL09NA-U1 Wall -Mounted 9,000.0 10,900.0 80.0167.0 70.0 FULL DEMAND 9,821.9 8,316.1 FULL DEMAND 9,264.1 3/8/1/4 406 43 phase Outdoor 1, 2, 3, 4, 5, 6 Notes & Options: 1 Nominal cooling capacities are based on indoor coil EAT of 80/67°F (DB/WB), outdoor of 95°F (DB) 2 Nominal heating capacities are based on indoor coil EAT of 70°F (DB), outdoor of 43°F (WB) 3 See outdoor unit schedule for outdoor ambient conditions, connected capacity, and other factors associated with corrected capacities 4 See schematic piping/control diagram for indication of required indoor unit remote controllers, system controllers, and integration devices. 5 Full demand corrected capacity includes de -rate associated with indoor vs. outdoor connected capacity indicated on outdoor unit schedule for associated system. Partial corrected capacity assumes sufficient diversity exists such that the connected capacity de -rate does not apply. It is the designer's responsibility to ensure "Diamond System Builder" is set in the appropriate output capacity setting (ful demand/partial demand) prior to generating this schedule. 6 It is recommended to always base heating corrected capacity on full demand. Job Name: Sundstone Condos System Reference: HVAC for elevator modernization I Date: 10/20/2021 1 IF F Indoor Unit: MSZ-GL09NA-U1 Wireless Remote Controller e Outdoor Unit: MUZ-GL09NA-U1 ACCESSORIES: Indoor Unit ❑ Condensate Pump (BlueDiamond X87-711/721; 115/23OV) ❑ Condensate Pump (Sauermann S130-115/230; 115/230V) ❑ Anti -Allergy Enzyme Filter (MAC-408FT-E) ❑ Drain Pan Level Sensor (DPLS2) Outdoor Unit ❑ Outdoor Mounting Pad (ULTRILITEI) ❑ Drain Pan Heater (MAC-640BH-U) ❑ 3-1/4" Mounting Base [Pair] (DSD-400P) ❑ Drain Pan Socket (MAC-860DS) ❑ Air Outlet Guide (MAC-889SG) 4 Wall Mounting Bracket (QSWB2000M-1) Controls ❑ Wireless Controller (MHK1) ❑ Wired Remote Controller PAR-32MAA (Requires MAC-3331F-E) ❑ Wireless Interface for kumo cloud TM (PAC-USWHS002-WF-1) ❑ Thermostat Interface (PAC-US444CN-1) SPECIFICATIONS: - Capacity.um Cooling' Btu/h Minimum 3,600 Maxim 12,200 Heating at 470 F2 Btu/h 4,500 15,900 Heating at 170 F3 Btu/h - 10,200 Heating at 5° F4 Btu/h - 8,100 ' Cooling I Indoor: 801 F(270 C)DB / 670 F(190 C)WB; Outdoor: 95o F(350 C)DB / 75o F(24o C)WB' 3 Heating at 470F I Indoor: 700 F (210C)DB / 60o F (160C)WB; Outdoor: 470 F (80C)DB / 43o F (60C)WB' 3 Heating at 171 F I Indoor: 700 F(210 C)DB / 60o F(160 C)WB; Outdoor: 170 F(-80 C)DB / 150 F(-90 C)WB' 4 Heating at 50 F I Indoor: 700 F (210C)DB / 60o F(160C)WB; Outdoor: 50 F(-150C) DB / 5o F(-150 C)WB Rating Conditions per AHRI Standard: Operating Conditons (Indoor Intake Air Temp.) (Max./ Min.) Cooling' 900 F (320 C) DB / 670 F (190 C) DB Heating 80° F (270 C) DB 1700 F (210 C) DB •.(Outdoor Cooling5 115 F (460 C) DB / 140 F (-10° C) DB Heating 75° F (240 C) DB / -4° F (-20° C) DB" s Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. " System cuts out at -90 F (-270 C) to avoid thermistor error and automatically restarts at -4o F (-200 C). • Yes ENERGY STAR products are third -party certified by an EPA -recognized Certification Body. Electrical Power Requirements Indoor / Outdoor I A 1 1/ 9 Indoor Blower Motor (ECM) F.L.A. 0.76 Blower Motor Output W 30 SHF / Moisture Removal 0.820 / 1.5 pt./h Field Drainpipe Size O.D. In.(mm) 5/8 (15) Airflow• Indoor DRY 145-170-237-321-399 WET 109-134-201-286-364 (Cooling) CFM Indoor DRY 145-170-237-321-406 (Heating) Outdoor 1,229 / 1,172 RefrigerantR410A; 2 1b. 5 oz. Refrigerant Piping (Flared) Liquid (High Pressure) In.(mm) 1/4 (6.35) Gas (Low Pressure) 3/8 (9.52) Max. Total Refrigerant 40 (12) Pipe Length (Height Diff.) Ft. (m) Max. Total Refrigerant 65 (20) Pipe Length (Length.) Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. I M MSZ-GL09NA-U1 MUZ-GL09NA-U1 A. oil irrr r ItoEl - 1� REQUIRED SPACE '1 4 in. (100 mm) or more when front and sides of the unit are clear m m 4 in Drain hole 01-21/32(GLoannlseA) 11 Drain hale 01-5/16 (GLovivisNAH) Air in m 'Yr�y1-9/16 �1 A' out 2-holes 3/8x13/16 Unit: in. (mm) 7/16xl3/I6 Oblona hole Air in Insulation o1 - 3/8 O.D a Liquid line o1/4 19 - 11/16 (Flared connection o1/4) E Gas line o3/8 16 - 15/16 (Flared connection: o3/8 (GL06109/12NA), o1/2 (GL15NA)) Drain hose Insulation o1-1/8 0.13 Connected part o5/8 O.D Qo mml "/ ago<`mo�e Z °�mO e '2 When any 2 sides of left, right and rear of the unit are clear Liquid refrigerant pipe joint Refrigerant pipe (flared) a 1/4 Gas refrigerant pipe joint Refrigerant pipe (flared) o 3/8 l � o,a Arc o' ' I Unit: in. (mm) MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www..mmehhna ac.com lie FORM# MSZ-GL09NA-U1 / MUZ-GL09NA-U1 - 201611 Intertek Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. LittleGUNT VCMX ■ Designed for automatic collection and removal of condensate from air conditioning, refrigeration and dehumidification equipment when gravity drainage is not possible or practical. Also suitable for high efficiency oil and gas -fired condensing furnace and condensing boiler equipment. ■ External test/run lever ■ Slim footprint ■ Vertical centrifugal pump design ■ Stainless steel motor shaft ■ Automatic start and stop operation ■ Galvanized steel "quick install" wall mount bracket ■ Some models equipped with external, float activated switch for automatic high- level water detection (overflow detection switch) ■ For models with overflow detection switch: dual function NO and NC operation (set to NO from factory for equipment shut down connection) ■ Models equipped with overflow detection switch include two 5" switch lead wires ■ 3/8" O.D. barbed %-turn quick release, locking discharge adapter with built-in check valve ■ Rubber feet for vibration/noise dampening ■ `Anti -sweat" tank sleeve included on select models and available separately for all others ■ 3-1-1/8" diameter inlet openings, two fitted with removable cap plug (3 + 1 inlet openings for models without overflow detection switch) ■ Recessed tank sump ■ Oil resistant tank and check valve ■ Thermally protected, fan cooled motor ■ Maximum water temperature:140 OF ■ 6', 3-conductor cable with grounded 3-prong plug ■ Some models include 20' x 3/8" I.D. vinyl discharge tubing ■ 3-year warranty 0CP Us All models NXTGEN'" NXTGEN'" with Tubing NXTGEN'" with Anti -Sweat Sleeve VCMX-20ULS VCMX NumberItem Part 154390 Feet, Rubber (4 pack554520,554530, 925047 554550, 554551, 554521, 554531) Cover, Motor 154425 Float Arm Assembly 154460 Check Valve, 3/8" 154724 Overflow Detection Switch Assembly 599136 (554530,554550,554551, 554542, 554531) Anti -sweat Sleeve and Bracket 599138 (554542) Bracket, Tank (554520,554530,554550, 154483 554551,554521,554531) B 0 A C ZAI-M974 Model VCMX-20UL 6.5" 165.1mm 10.2" 259.1 mm 4.8" 121.9 mm D 3.4" 86.4 mm VCMX-20ULS 6.5" (165.1mm) 10.2" (259.1 mm) 4.8" (121.9 mm) 3.4" (86.4 mm) VCMX-20ULST 6.5" (165.1mm) 10.2" (259.1 mm) 4.8" (121.9 mm) 3.4" (86.4 mm) VCMX-20ULS-C 6.8" (172.7mm) 10.3" (261.6 mm) 5.1" (129.5 mm) 3.4" (86.4 mm) up PTO , myr -M I Flow - Liters/Hour 0 75 150 225 25 5 0 0 115V. 60 Hz 230V, 60 Hz 300 375 7.5 20 40 60 80 Flow - Gallons/Hour 5 _+ 0 100 Housing/Tank Cover ABS Motor Cover ABS Volute ABS Tank Polypropylene Impeller Polypropylene Switch Float ABS Check Valve Acetal C PF D Franklin Electric Hotline:1.800.701.7894 1 www.littlegiant.com