Loading...
REVIEWED-BLD2022-0894+Structural_Analysis_or_Calculations+7.8.2022_9.51.34_AM+2976873I.L. GROSS .............................................. STRUCTURAL REVIEWED ENGINEERS BY CITY OF EDMONDS RECEIVED BUILDING DEPARTMENT''- Jul 11 2022 ............................................... CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-0894 CAMPBELL - SERKE REMODEL 1 6 10 Qt" AVE N E::)M0NPS1 ,IAA Structural calculations for Permit submittal For Y4001:)cRAFTERS CONSTRUCTION MAY 200 2022 23914 5&h Ave W. - Suite # 200 Mountlake Terrace, WA 98043 Ph. (206) 623-0769 • (425) 640-7333 #. n a F OL Fp-^-M 1 N to H dF- av e OPAY W t:;-W-fp- r R� HDR v�l�- I-trI4 tom.! YUAW TA 1,65w � 1r� �.2 -fx1a (ter WL.,F-V) LN L. 3 .:> A. -71 lzs 0 J S T D IlZ N dT VP�RI t ED yc` 2n i FLU r-FAMi NCB -Zf— SHEET TITLE 0 SCALE DATE GCp PROJECT DESIGNED BY I.L. GROSS �y iN S�IC NCI NERS N$ CLIENT CHECKED SHEET www.ilgross.com I.L. GROSS STRUCTURAL ENGINEERS 23914 56TH AVE W - STE 200 MILT, WA 98043 www.ilgross.com Project Title: CAMPBELL-GERKE REMODEL Engineer: Project ID: Project Descr: Multiple SII'1'lple Beam Project File: CAMPBELL.ec6 LIC# : KW-06016108, Build:20.22.3.16 I.L. GROSS STRUCTURAL ENGINEERS (c) ENERCALC INC 1983-2022 Description : FRAMING Wood Beam Design: ROOF (a) BAY Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 2x6, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 RLM Load Combinations, Major Axis Bending Wood Species : Douglas Fir -Larch Wood Grade: No.2 Fb - Tension 900.0 psi Fc - Prll 1,350.0 psi Fv 180.0 psi Ebend- xx 1,600.0 ksi Density 31.210 pcf Fb - Compr 900.0 psi Fc - Perp 625.0 psi Ft 575.0 psi Eminbend - xx 580.0 ksi AAnalied Loads Beam self weight calculated and added to loads Unif Load: D = 0.0160, Lr = 0.0250 k/ft, Trib= 2.0 ft Design Summary Max fb/Fb Ratio = 0.105. 1 fb : Actual : 149.57 psi at 1.500 ft in Span # 1 Fb: Allowable: 1,420.77 psi Load Comb: +D+Lr Max fv/FvRatio = 0.071 : 1 fv : Actual : 16.00 psi at 2.550 ft in Span # 1 Fv: Allowable: 225.00 psi Load Comb: +D+Lr Max Reactions (k) D L Lr S W E Left Support 0.05 0.08 Right Support 0.05 0.08 Wood Beam Design: HDR ((D BAY WDW .•. ... _��" H Transient Downward 0.003 in Total Downward 0.005 in Ratio 9999 Ratio 7803 LC: Lr Only LC: +D+Lr Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 4x12, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 RLM Load Combinations, Major Axis Bending Wood Species : Douglas Fir -Larch Wood Grade : Select Structural Fb - Tension 1,500.0 psi Fc - Prll 1,700.0 psi Fv 180.0 psi Ebend- xx 1,900.0 ksi Density 31.210 pcf Fb - Compr 1,500.0 psi Fc - Perp 625.0 psi Ft 1,000.0 psi Eminbend - xx 690.0 ksi AApolied Loads Beam self weight calculated and added to loads Unif Load: D = 0.0160, Lr = 0.0250 k/ft, Trib= 4.0 ft Unif Load: D = 0.0180, L = 0.040 k/ft, Trib= 7.50 ft Unif Load: D = 0.0150 k/ft, Trib= 8.0 ft Design Summary Max fb/Fb Ratio = 0.799 : 1 fb : Actual : 1,274.99 psi at 5.000 ft in Span # 1 Fb: Allowable: 1,595.50 psi Load Comb: +D+L Max fv/FvRatio = 0.540 : 1 fv : Actual : 97.22 psi at 9.067 ft in Span # 1 Fv: Allowable: 180.00 psi Load Comb: +D+L Max Reactions (k) D L Lr S W E Left Support 1.64 1.50 0.50 Right Support 1.64 1.50 0.50 H Transient Downward 0.086 in Total Downward 0.180 in Ratio 1395 Ratio 667 LC: L Only LC: +D+L Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: I.L. GROSS STRUCTURAL ENGINEERS Project Title: CAMPBELL-GERKE REMODEL 23914 56TH AVE W - STE 200 Engineer: MILT, WA 98043 Project ID: www.ilgross.com Project Descr: Multiple Simple Beam Project File: CAMPBELL.ec6 LIC# : KW-06016108, Build:20.22.3.16 I.L. GROSS STRUCTURAL ENGINEERS (c) ENERCALC INC 1983-2022 Wood Beam Design: JOISTS (@ BAY WDW with HEAVY RANGE Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 1.75x9.25, Microllam LVL, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 RLM Load Combinations, Major Axis Bending Wood Species : iLevel Truss Joist Wood Grade: TimberStrand LSL 1.55E Fb - Tension 2,325.0 psi Fc - Prll 2,050.0 psi Fv 310.0 psi Ebend- xx 1,550.0 ksi Density 45.010 pcf Fb - Compr 2,325.0 psi Fc - Perp 800.0 psi Ft 1,070.0 psi Eminbend - xx 787.82 ksi Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.0160, Lr = 0.0250 k/ft, Trib= 2.0 ft Unif Load: D = 0.0180, L = 0.040 k/ft, Trib= 1.330 ft Unif Load: D = 0.20 k/ft, -2.50 to 0.0 ft, Trib= 1.330 ft 1 Point: D = 0.210 k @ -2.50 ft Design Summary Max fb/Fb Ratio = 0.470. 1 fb : Actual : 823.75 psi at 0.000 ft in Span # 2 Fb: Allowable: 1,752.53 psi Load Comb: +D+L Max fv/FvRatio = 0.260 : 1 fv : Actual : 80.67 psi at 1.738 ft in Span # 1 Fv: Allowable: 310.00 psi Load Comb: +D+L Max Reactions (k) D L Lr S w E Left Support 1.46 0.33 0.31 Right Support -0.04 0.15 0.14 Wood Beam Design: JOISTS (@ BAY WDW D 0.2660 p 1.75x9.25 1.75x925 2.50 ft 6.50 ft H Transient Downward 0.008 in Total Downward 0.090 in Ratio 9999 Ratio 664 LC: L Only LC: D Only Transient Upward -0.003 in Total Upward -0.028 in Ratio 9999 Ratio 2804 LC: L Only LC: D Only Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 1.75x9.25, Microllam LVL, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 RLM Load Combinations, Major Axis Bending Wood Species : iLevel Truss Joist Wood Grade: TimberStrand LSL 1.55E Fb - Tension 2,325.0 psi Fc - Prll 2,050.0 psi Fv 310.0 psi Ebend- xx 1,550.0 ksi Density 45.010 pcf Fb - Compr 2,325.0 psi Fc - Perp 800.0 psi Ft 1,070.0 psi Eminbend - xx 787.82 ksi Ayplied Loads Beam self weight calculated and added to loads Unif Load: D = 0.0160, Lr = 0.0250 k/ft, Trib= 2.0 ft Unif Load: D = 0.0180, L = 0.040 k/ft, Trib= 1.330 ft Unif Load: D = 0.250 k/ft, Trib= 1.330 ft 1 Point: D = 0.210 k @ -2.50 ft Design Summary Max fb/Fb Ratio = 0.451 • 1 fb : Actual : 923.68 psi at 0.000 ft in Span # 2 Fb: Allowable: 2,049.92 psi Load Comb: +D+L Max fv/FvRatio = 0.326 : 1 fv : Actual : 101.02 psi at 2.500 ft in Span # 1 Fv: Allowable: 310.00 psi Load Comb: +D+L Max Reactions (k) D L Lr S w E Left Support 2.47 0.29 0.27 Right Support 0.50 0.08 0.08 1.75x9.25 1.75x9.25 1* 2.50 ft 4.50 ft H Transient Downward 0.004 in Total Downward 0.062 in Ratio 9999 Ratio 966 LC: L Only LC: +D+0.750Lr+0.750L Transient Upward 0.000 in Total Upward -0.005 in Ratio 9999 Ratio 9999 LC: LC: D Only I.L. GROSS STRUCTURAL ENGINEERS Project Title: CAMPBELL-GERKE REMODEL 23914 56TH AVE W - STE 200 Engineer: MILT, WA 98043 Project ID: www.ilgross.com Project Descr: Multiple Simple Beam Project File: CAMPBELL.ec6 LIC# : KW-06016108, Build:20.22.3.16 I.L. GROSS STRUCTURAL ENGINEERS (c) ENERCALC INC 1983-2022 Wood Beam Design: HDR OVER KITCHEN WDW Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 3.5x7.25, VersaLam, Fully Unbraced Using Allowable Stress Design with ASCE 7-16 RLM Load Combinations, Major Axis Bending Wood Species : iLevel Truss Joist Wood Grade: MicroLam LVL 2.0 E Fb - Tension 2600 psi Fc - Prll 2510 psi Fv 285 psi Ebend- xx 2000 ksi Density 42.01 pcf Fb - Compr 2600 psi Fc - Perp 750 psi Ft 1555 psi Eminbend - xx 1016.535 ksi Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.0140, Lr = 0.0250 k/ft, Trib= 10.0 ft Unif Load: D = 0.0160, L = 0.040 k/ft, Trib= 7.50 ft Unif Load: D = 0.0150 k/ft, Trib= 8.0 ft Design Summary Max fb/Fb Ratio = 0.840. 1 fb : Actual : 2,152.24 psi at 4.000 ft in Span # 1 Fb: Allowable: 2,563.50 psi Load Comb: +D+L Max fv/FvRatio = 0.487 : 1 fv : Actual : 138.70 psi at 0.000 ft in Span # 1 Fv : Allowable: 285.00 psi Load Comb: +D+L Max Reactions (k) D L Lr S W E H Left Support 1.55 1.20 1.00 Right Support 1.55 1.20 1.00 ■� �• L.q, .,� s Transient Downward 0.125 in Ratio 767 LC: L Only Transient Upward 0.000 in Ratio 9999 LC: Total Downward 0.333 in Ratio 287 LC: +D+0.750Lr+0.750L Total Upward 0.000 in Ratio 9999 LC: dE4.6.e. 4r�M tNC7 b b�� hi 6t +rs vol. jolevTs " P spy to Ps �- DE, ro r%P- LL w P C.,-T J pKTs 2K 122 RF *-I (F 2` 2x � *s & I&;"r T nt� 27 1'L ,-zw l a I i;116 • Vic, D.O9 TAr = l Lv`�oli p .4t; �X12 Prr-:W-Z 67'3�k. SHEET TITLE SCALE DATE PROJECT DESIGNED BY V �G I.L. GROSS 6- STRUCTURAL ENGINEERS CLIENT CHECKED SHEET www.ilgross.com I.L. GROSS STRUCTURAL ENGINEERS 23914 56TH AVE W - STE 200 MILT, WA 98043 www.ilgross.com Project Title: CAMPBELL-GERKE REMODEL Engineer: Project ID: Project Descr: Multiple Simple Beam Project File: CAMPBELL.ec6 LIC# : KW-06016108, Build:20.22.3.16 I.L. GROSS STRUCTURAL ENGINEERS (c) ENERCALC INC 1983-2022 Description: NEW DECK FRAMING Wood Beam Design: WEST JOISTS CLEAR SPAN Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 2x12, Sawn, Defined Brace Locations, 1st at 5.0 ft, 2nd at 10.0 ft, 3rc Using Allowable Stress Design with ASCE 7-16 RLM Load Combinations, Major Axis Bending Wood Species : Hem -Fir Wood Grade: No.1 Fb - Tension 975.0 psi Fc - Prll 1,350.0 psi Fv 150.0 psi Ebend- xx 1,500.0 ksi Density 26.840 pcf Fb - Compr 975.0 psi Fc - Perp 405.0 psi Ft 625.0 psi Eminbend - xx 550.0 ksi AAnalied Loads Beam self weight calculated and added to loads Unif Load: D = 0.010, L = 0.060 k/ft, Trib= 1.0 ft Design Summary Max fb/Fb Ratio = 0.943. 1 fb : Actual : 679.66 psi at 7.000 ft in Span # 1 Fb: Allowable: 721.06 psi Load Comb: +D+L Max fv/FvRatio = 0.271 : 1 fv : Actual : 39.44 psi at 13.067 ft in Span # 1 Fv: Allowable: 145.50 psi Load Comb: +D+L Max Reactions (k) D L Lr S W E Left Support 0.09 0.42 Right Support 0.09 0.42 D(0.010) L 0( 060) 2x12 14.0 ft H Transient Downward 0.217 in Total Downward 0.265 in Ratio 774 Ratio 635 LC: L Only LC: +D+L Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Wood Beam Design: WEST JOISTS - INTERIOR SUPPORT Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 2x8, Sawn, Defined Brace Locations, 1st at 5.0 ft, 2nd at 10.0 ft, 3rd Using Allowable Stress Design with ASCE 7-16 RLM Load Combinations, Major Axis Bending Wood Species : Hem -Fir Wood Grade: No.2 Fb - Tension 850.0 psi Fc - Prll 1,300.0 psi Fv 150.0 psi Ebend- xx 1,300.0 ksi Density 26.840 pcf Fb - Compr 850.0 psi Fc - Perp 405.0 psi Ft 525.0 psi Eminbend - xx 470.0 ksi AApolied Loads Beam self weight calculated and added to loads Unif Load: D = 0.010, L = 0.060 k/ft, Trib= 1.330 ft Design Summary Max fb/Fb Ratio = 0.662. 1 fb : Actual : 532.08 psf at 3.500 ft in Span # 1 Fb: Allowable: 804.20 psi Load Comb: +D+L Max fv/FvRatio = 0.263 : 1 fv : Actual : 38.27 psi at 6.417 ft in Span # 1 Fv: Allowable: 145.50 psi Load Comb: +D+L Max Reactions (k) D L Lr S W E Left Support 0.05 0.28 Right Support 0.05 0.28 D 0.01330 L 0.07980 2x8 7.0 ft H Transient Downward 0.078 in Total Downward 0.093 in Ratio 1080 Ratio 906 LC: L Only LC: +D+L Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: I.L. GROSS STRUCTURAL ENGINEERS Project Title: CAMPBELL-GERKE REMODEL 23914 56TH AVE W - STE 200 Engineer: MILT, WA 98043 Project ID: www.ilgross.com Project Descr: Multiple Simple Beam Project File: CAMPBELL.ec6 LIC# : KW-06016108, Build:20.22.3.16 I.L. GROSS STRUCTURAL ENGINEERS (c) ENERCALC INC 1983-2022 Wood Beam Design: EAST JOISTS Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 2x12, Sawn, Defined Brace Locations, 1st at 5.0 ft, 2nd at 10.0 ft, 3rc Using Allowable Stress Design with ASCE 7-16 RLM Load Combinations, Major Axis Bending Wood Species : Hem -Fir Wood Grade: No.1 Fb - Tension 975.0 psi Fc - Prll 1,350.0 psi Fv 150.0 psi Ebend- xx 1,500.0 ksi Density 26.840 pcf Fb - Compr 975.0 psi Fc - Perp 405.0 psi Ft 625.0 psi Eminbend - xx 550.0 ksi Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.010, L = 0.060 k/ft, Trib= 1.330 ft Design Summary Max fb/Fb Ratio = 0.836 : 1 fb : Actual : 603.42 psi at 5.750 ft in Span # 1 Fb: Allowable: 721.55 psi Load Comb: +D+L Max fv/FvRatio = 0.284 : 1 fv : Actual : 41.32 psi at 0.000 ft in Span # 1 Fv: Allowable: 145.50 psi Load Comb: +D+L Max Reactions (k) D L L-r S w E H Left Support 0.09 0.46 Right Support 0.09 0.46 Wood Beam Design: TYP BEAM D(0.01330) L(0.07980) 2x12 11.50 ft Transient Downward 0.131 in Ratio 1050 LC: L Only Transient Upward 0.000 in Ratio 9999 LC: Total Downward 0.158 in Ratio 870 LC: +D+L Total Upward 0.000 in Ratio 9999 LC: Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 4x12, Sawn, Defined Brace Locations, 1st at 5.0 ft, 2nd at 10.0 ft, 3rc Using Allowable Stress Design with ASCE 7-16 RLM Load Combinations, Major Axis Bending Wood Species: Hem -Fir Wood Grade: No.2 Fb - Tension 850 psi Fc - Prll 1300 psi Fv 150 psi Ebend- xx 1300 ksi Density 26.84 pcf Fb - Compr 850 psi Fc - Perp 405 psi Ft 525 psi Eminbend - xx 470 ksi Ayplied Loads Beam self weight calculated and added to loads Unif Load: D = 0.010, L = 0.060 k/ft, Trib= 7.0 ft Design Summary Max fb/Fb Ratio = 0.822. 1 fb : Actual : 646.70 psi at 4.000 ft in Span # 1 Fb: Allowable: 786.39 psi Load Comb: +D+L Max fv/FvRatio = 0.399 : 1 fv : Actual : 58.10 psi at 0.000 ft in Span # 1 Fv: Allowable: 145.50 psi Load Comb: +D+L Max Reactions (k) D L Lr S W E H Left Support 0.31 1.68 Right Support 0.31 1.68 D 0.070 L 0.420 4x12 8.0 ft Transient Downward 0.080 in Ratio 1198 LC: L Only Transient Upward 0.000 in Ratio 9999 LC: Total Downward 0.095 in Ratio 1012 LC: +D+L Total Upward 0.000 in Ratio 9999 LC: I.L. GROSS STRUCTURAL ENGINEERS Project Title: CAMPBELL-GERKE REMODEL 23914 56TH AVE W - STE 200 Engineer: MILT, WA 98043 Project ID: www.ilgross.com Project Descr: Wood Column Project File: CAMPBELL.ec6 LIC# : KW-06016108, Build:20.22.3.16 I.L. GROSS STRUCTURAL ENGINEERS (c) ENERCALC INC 1983-2022 DESCRIPTION: DECK PORCH POSTS Code References Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used : ASCE 7-16 RLM General Information Analysis Method Allowable Stress Design Wood Section Name 4x4 End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber Overall Column Height 8 ft Wood Member Type Sawn (Used for non -slender calculations) Exact Width 3.50 in Allow Stress Modification Factors Wood Species Hem -Fir Exact Depth 3.50 in Cf or Cv for Bending 1.50 Wood Grade No.2 Area 12.250 inA2 Cf or Cv for Compressioi 1.150 Fb + 850 psi Fv 150 psi Ix 12.505 inA4 Cf or Cv for Tension 1.50 Fb - 850 psi Ft 525 psi ly 12Cm :Wet Use Factor .505 in 4 1.0 Fc - Prll 1300 psi Density 26.84 pcf Ct : Temperature Fact 1.0 Fc - Perp 405 psi Cfu : Flat Use Factor 1.0 E : Modulus of Elasticity ... x-x Bending y-y Bending Axial Kf : Built-up columns 1.0 NDS 15.3.2 Basic 1300 1300 1300 ksi Use Cr: Repetitive ? No Minimum 470 470 Brace condition for deflection (buckling) along columns : X-X (width) axis: Unbraced Length for buckling ABOUT Y-Y Axis = 8 Y-Y (depth) axis : Unbraced Length for buckling ABOUT X-X Axis = 8 Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weight included : 18.266 Ibs * Dead Load Factor AXIAL LOADS ... Axial Load at 8.0 ft, D = 0.640, L = 3.40 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio = 0.7043 : 1 Maximum SERVICE Lateral Load Reactions. . Load Combination +D+L Top along Y-1 0.0 k Bottom along Y-Y 0.0 k Governing NDS Forumla Comp Only, fc/Fc' Top along X-)� 0.0 k Bottom along X-X 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections ... At maximum location values are . Along Y-Y 0.0 in at 0.0 ft above base Applied Axial 4.058 k for load combination : n/a Applied Mx 0.0 k-ft Applied My 0.0 k-ft Along X-X 0.0 in at 0.0 ft above base Fc: Allowable 470.346 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio = 0.0 : 1 Bendina Compression Tension Load Combination +0.60D Location of max.above base 8.0 ft Applied Design Shear 0.0 psi Allowable Shear 240.0 psi Load Combination Results Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location +D+L 1.000 0.315 0.7043 PASS 0.0 ft 0.0 PASS 8.0 ft D Only 1.150 0.277 0.1127 PASS 0.0ft 0.0 PASS 8.0 ft +D+0.750L 1.150 0.277 0.5492 PASS 0.0 ft 0.0 PASS 8.0 ft +0.60D 1.600 0.204 0.06601 PASS 0.0 ft 0.0 PASS 8.0 ft Maximum Reactions Note: Only non -zero reactions are listed. X-X Axis Reaction k Y-Y Axis Reaction Axial Reaction My - End Moments k-ft Mx - End Moments Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top +D+L 4.058 +D+0.750L 3.208 I.L. GROSS STRUCTURAL ENGINEERS 23914 56TH AVE W - STE 200 MILT, WA 98043 www.ilgross.com Project Title: CAMPBELL-GERKE REMODEL Engineer: Project ID: Project Descr: Woof) Column _ _ Project File: CAMPBELL.ec6 DESCRIPTION: DECK PORCH POSTS Maximum Reactions Note: Only non -zero reactions are listed. X-X Axis Reaction k Y-Y Axis Reaction Axial Reaction My - End Moments k-ft Mx - End Moments Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top +0.60D 0.395 L Only 3.400 Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance D Only 0.0000 in 0.000ft 0.000 in 0.000ft +D+L 0.0000 in 0.000ft 0.000 in 0.000ft +D+0.750L 0.0000 in 0.000ft 0.000 in 0.000ft +0.60D 0.0000 in 0.000ft 0.000 in 0.000ft L Only 0.0000 in 0.000ft 0.000 in 0.000ft Sketches c 0 CO 4 3.50 in 1 +X 4.040k 4.OIOk