APPROVED BLD 23023 74TH Ave W Propane Tank Plan and ElevationCity Of Edmonds Building Department --------------------- Work r PROPANE TANK Address 23023 74TH AVE W Owner '------------------------------ZIPPER ------------------------------------------------------ ----------------------------------------------- Approved Date: 1 /22/2021 - ---------------------------------- Building Official w• W d--4;kLacc Permit Number BLD2021-0056 ----------------------- ALL WORK SUBJECT City of Edmonds APPROVED TO FIELD Building Department PLANS MUST BE INSPECTION FOR APPROVED Plans ON JOB SITE CODE COMPLIANCE RECEIVED Jan 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT (E) WOOD DECK 36 SQ.FT. (E) ]SHEDs0 9 11(E) CONCRETEFF c WALKWAY & PATIO 858 SQ.Fr. � � . xs�em•u � Approved by Fire 01/20/2021 AFM ICFGtteI'er Approved per above NFPA 58 standards PROPERTY LINE147.86' S89' 48' 00" E �(E) GRASS jE6 G (E) DWELLING 1748 SQ.FT. 1 I — I I (E) WOOD DECK 176 SQ.FT. I 0 0 i OUT \\ P \ (E) LANDSOPING y/ \� _`,j (E) GRAVEL n� DRIVEWAY / \ 2� P a \ I / C � \ \ I / I\ E) LANDSCAPING \ I � // W / I(E) SHED oN, 40 SQ.Fr. o / (E) WATER SERVICE — EASEMENT �N PROPERTY LINE 117.54' S89' 48' VE 120 GALLON PROPANE TANKS: TWO LOCATED ________ _ UNDER EAVES AT SE .Owner/Applicant to obtain the proper perm CORNER OF HOUSE ;prior to installation. / / / / / / PROPERTY: NORTH 23023 74TH AVENUE W, EDMONDS, WA. 98026-8502 PARCEL NO.: #00488800200403 (R01) N LEGAL DESCRIPTION: LAKE BALLINGER LAND CO SUBDIV 1 BLK 002 D-03 - BEG 296.03FT E OF NW COR IT 4 TPB TH S81 FT M/L TO A FENCE TH S89*48 OOE ALG FENCE LN 1 OOFT M/I TO INTERURBAN R/W TH NLY ALG SD R/W TO N IN IT 4 TH W ALG SD N IN TPB LOT SIZE: 0.26 ACRE(S) (NO CHANGE) ZONING: RS-8 OWNER / CONTACT: JOHN ZIPPER KATHY ZIPPER 23023 74TH AVENUE W. EDMONDS, WA. 98026 / NOTES FOR PROPANE TANK: 1. LOCATION OF TANK: SOUTH SIDE OF HOUSE AT SE CORNER 2. DISTANCE FROM HOUSE: LESS THAN 1 FOOT 3. ELEVATION VIEW: SKETCH SUBMITTED SEPARATELY 4. MOUNTING INFORMATION: FREE STANDING ON CONCRETE PAD 5. LOCATION OF GAS PIPE: PIPE ENTERS CRALWSPACE AT TANK LOCATION, ROUGHLY 2 FEET ABOVE EXTERIOR GRADE • NO EXPOSED SOILS ARE EXPECTED DURING THE COURSE OF CONSTRUCTION. • NO NEW STRUCTURES, DRIVEWAYS, PARKING AREAS, SIDEWALKS, OR PATIOS PROPOSED. • NO AREAS OF DISTURBANCE PROPOSED. PARCEL PLAN / AREA OF PROJECT 2436 SCALE: 1 "=10'-0" 11 A 7 SCALE: 1"=20'-O" MARKUP BY OWNER FOR PROPANE TANK PERMIT SUBMITTAL JAN. 15, 2021 PROJECT INFORMATION: RELATED PERMIT BLD2020-0914 W W la a_ CL N w o 00 v! _ cy) IY Y Q vi LU a- = o co 0 N W STAMP: RES t 2 2020 CITY MONDS DEVELO MEN RVICES PARTMEN SCHEMATIC DESIGN W/26/2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03126/2020 B REV. LAYOUTS 04/16/2020 C REVS PER COMMENTS 0710112020 ,D ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 1Q CITY REVIEW COMMENTS 09/27/2020 DRAWN BY: WMK APPROVED BY: DJMK SHEET TITLE: PARCEL PLAN SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: C-1 .0 • of. - of -, • -4 117 Location of two 44 120 gallon _ .:. ✓ xr , e 't ".. i ivy,, _ � - _:� �*...'/ , ` Y w; " . propane tanks on vent and conduit to = °� 4 concrete pad. Gas be removed and piping into relocated > 5 feet crawispace 2 feet from propane tanks above ground level ELEVATION VIEW OF SE CORNER, 23023 74T" AVE W, EDMONDS WA (Tanks are to be properly (Plans have been 'secured to prevent from 'reviewed for the Tanks movement in a seismic event. I -to be located on a 'concrete pad without Ian .enclosure..