Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD2021-1698+Manufacturer_Specifications_and_Installation_Instructions+12.15.2021_1.55.29_PM+2575150
Honeywell I Generators 10/14/18 kW Air- Cooled Generator Sets Standby Power Rating Model G007179-0 (Aluminum - Dark Gray) -10 kW 60 Hz Model G007229-0 (Aluminum - Dark Gray) -14 kW 60 Hz Model G007230-0 (Aluminum - Dark Gray) -18 kW 60 Hz INCLUDES BLD2021-1698 REVIEWED BY CITY OF EDMONDS • Innovative engine design and rigorous testing: Honeywell generators use Generac's industry leading G-Force engine lineup for added peace of mind and reliability for when you need it most. The G-Force series of engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. • Precision Power'" Electrical Technology: Superior harmonics and sine wave form produce less than 5%Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic and microchip based appliances, such as variable speed HVAC. • Solid -State, Frequency Compensated Voltage Regulation: This state- of-the-art, power maximizing regulation system is the standard on all Honeywell models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at± 1%. • Single Source Service Response: Our extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electrical component. • Honeywell Transfer Switches: The Honeywell generator line is offered with its own transfer systems and controls fortotal system compatibility. • 18 in (457 mm) Offset: Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in (457 mm) to a structure.* *Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. FEATURES & BENEFITS • Precision Power- • Standard Wi-Fi' • Flexible Fuel Line Electrical Technology Remote Monitoring Connector • Two -Line Multilingual • Electronic Governor • WhisperCheck'"' Digital LCD Controller Exercise (English, Spanish, •System and Status & Maintenance Interval • Sound Attenuated French, Portuguese) LED Indicators Enclosure • Natural Gas or LP Gas Operation • 5 Year Premium Limited Warranty • Capabilityto be installed within 18 in (457 mm) of a building* RECEIVED Dec 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT * Only if located away from doors, windows, and fresh air intakes, unless otherwise directed by local codes. ** US version is ETL or UL listed only. 10/14/18 kW Standby Generator Technical Specifications ENGINE WhisperCheck—: Greatly reduces sound output and fuel consumption during selectable weekly, bi- weekly, or monthly exercise. Generac G-Force design: Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life. "Spiny-lok" cast iron cylinder walls: Rigid construction and added durability provide long engine life. Electronic ignition/spark advance: These features combine to assure smooth, quick starting every time. Full pressure lubrication system: Pressurized lubrication to allvital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. Low oil pressure shutdown system: Shutdown protection prevents catastrophic engine damage due to low oil. High temperature shutdown: Prevents damage due to overheating. GENERATOR Test criteria: Prototype tested; system torsional tested; NEMA MG1-22 evaluation; motor starting ability. Revolving field: Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. Skewed stator: Produces a smooth output waveform for compatibility with electronic equipment. Displaced phase excitation: Maximizes motor starting capability. Automatic voltage regulation: Regulating output voltage to ± 1%; prevents damaging voltage spikes UL 2200 Listed: Foryour safety. I,1.7:3I11=111I21:{°AAOd1191912121=leidkTJki'1 Free with every Honeywell home standby generator. Ability to view generator status: Monitor your generator with a smartphone, tablet, or computer at anytime via the Mobile Link application for complete peace of mind. Ability to view generator Exercise/Run and Total Hours: Review the generator's complete protection profile for exercise hours and total hours. Ability to view generator maintenance information: Provides maintenance information foryour specific model generator when scheduled maintenance is due. Monthly report with previous month's activity: Detailed monthly reports provide historical generator information. Ability to view generator battery information: Built-in battery diagnostics display current state of the battery. Weather information: Provides detailed local ambient weather conditions for generator location. TRANSFER SWITCH Sold separately. SYNC— 3.0 CONTROLS AUTO/MANUAL/OFF illuminated buttons: Select the operating mode and provide easy, at a glance status indication of any condition. Two-line plain text multilingual LCD: Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences. Sealed, raised buttons: Smooth, weather -resistant user interface for programming and operations. Utility voltage sensing: Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up of standard voltage. Generator voltage sensing: Constantly monitors generator voltage to ensure the cleanest power delivered to the home. Utility interrupt delay: Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of five seconds by a qualified dealer. Engine warm-up: Ensures engine is readyto assume the load, setpoint approximately five seconds. Engine cool -down: Allows engine to cool prior to shutdown, setpoint approximately one minute. Programmable exerciser: Operates engine to prevent oil seal drying and damage between power outages by running the generator for five minutes every other week. Also offers a selectable setting for weekly or monthly operation, providing flexibility and lower fuel costs to the owner. Smart battery charger: Delivers charge to the battery onlywhen needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. Electronic governor: Maintains constant 60 Hz frequency. UNIT SAE aluminum weather protective enclosure: Sound attenuated enclosure provides quiet operation and weather protection, able to withstand winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front panel for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. Enclosed critical grade muffler: Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Small, compact, attractive: Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure. INSTALLATION SYSTEM 14 in (35.6 cm) flexible fuel line connector: Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. Integralsedimenttrap: Meets IFGC and NFPA54 installation requirements. 10/14/18 kW Standby Generator Technical Specifications Rated maximum continuous power capacity (LP) Rated maximum continuous power capacity (NG) Rated voltage Rated maximum continuous load current- 240V(LP/ NG) Total Harmonic Distortion Main line circuit breaker Phase Number of rotor poles Rated AC frequency Power factor Battery requirement (not included) Unit weight (lb / kg) Dimensions (L x W x H) (in / cm) Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load** Sound output in dB(A) at 23 ft (7 m) with generator in WhisperCheck'' low speed exercise Exercise duration Engine type Number of cylinders Displacement Cylinder block Valve arrangement Lifter type Ignition system Governor system Compression ratio Starter Oil capacity including filter Operating rpm Fuel consumption Natural gas: ft3/hr (m3/hr) 1/2 load Full load Liquid propane: ft3/hr (gal/hr) [L/hr] 1/2 load Full load Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fu column (2.49-2.99 kPa) for LP gas. For BTU content, multiple ft3/hrx 2,500 (LP) x 37.26 (NG). 10,000 Watts* 14,000 Watts* 18,000 Watts* 9,000 Watts* 14,000 Watts* 17,000 Watts* 240 41.7/37.5 58.3/58.3 75.0/70.8 Less than 5% 45amp 60amp 80amp 1 2 60 Hz 1.0 12 volts, Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum 338/153 385/175 420/191 48x25x29/121.8x63.8x73.2 61 65 65 57 55 55 5 min GENERAC G-FORCE GENERAC G-FORCE 800 SERIES 400 SERIES 1 2 460 cc 816 cc Aluminum w/ cast iron sleeve Overhead valve Solid Hydraulic Solid-state w/ magneto Electronic 9.5:1 12 VDC Approx 1.1 qt / 1.0 L Approx. 2.2 qt / 2.1 L 3,600 101(2.86) 195 (5.52) 169 (5.52) 127 (3.60) 256 (7.25) 247 (6.99) 36 (0.97) [3.66] 66 (1.81) [6.87] 62 (1.70) [6.45] 54 (1.48) [5.62] 112 (3.07) [11.611 110 (3.02) [11.441 �l inlet — 3.5-7.0 in water column (0.87-1.74 kPa) for natural gas,10-12 in water orft3/hr x 1,000 (NG). For Megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr 10/14/18 kW Standby Generator Technical Specifications Two-line plain text multilingual LCD Mode buttons: AUTO MANUAL OFF Ready to Run/Maintenance messages Engine run hours indication Programmable start delay between 2-1500 seconds Utilityvoltage loss/Return to utility adjustable (brownout settings) Future set capable exerciser/Exercise set error warning Run/Alarm/Maintenance logs Engine start sequence Starter lock -out Smart battery charger Charger fault/missing AC warning Low battery/battery problem protection and battery condition indication Automatic voltage regulation with over and under voltage protection Under-frequency/overload/stepper overcurrent protection Safety fused/fuse problem protection Automatic low oil pressure/high oiltemperature shutdown Overcrank/overspeed (C 72 Hz)/rpm sense loss shutdown High engine temperature shutdown Internal fault/incorrect wiring protection Common externalfault capability Field upgradable firmware Rating definitions - Optional Standby: Applicable forsupplying backup powerfortl overload capability is available for this rating. (All ratings in accordance with BS55. * Maximum kilovolt amps and current are subjected to and limited by such factors condition, etc. Maximum power decreases approximately 3.5%for each 1,000 ft (: TF (161C). **Sound levels are taken from the front of the generator. Sound levels t� parameters.. Simple user interface for ease of operation Automatic start on utility failure. Weekly, Bi-Weekly, or Monthly selectable exerciser Start with starter control, unit stays on. If utility fails, transfer to load takes place. Stops unit. Power is removed. Controller and charger still operate. Standard Standard Standard (dealer programmable only) From 140-171 V / 190-216 V Standard 50 events each Cyclic cranking:16 sec on, 7 sec rest (90 sec maximum duration) Starter cannot re-engage until 5 sec after engine has stopped Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard e duration of the utility power outage when correct maintenance is performed. No .4, IS03046, UL2200, and DIN6271). s fuel BUT/megajoule content, ambient temperature, altitude, engine power and 104.8 m) above sea level and approximately 1%for each 10 TF (6 TC) above 60 ken from other sides of the generator may be higher depending on installation 10/14/18 kW Standby Generator Available Accessories Kim �IJMIONHA11., G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. The recommended26R wet cell battery is for use with all air-cooled standby product.. G007101-0 Battery Pad Warmer The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0 °F (-18 °C). (Not necessary for use with AGM -style batteries.) G007102-0 Oil Warmer The oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 0 °F (-18 °C). G007103-1 Breather Warmer The breather warmer is for use in extreme cold weather applications. For use with Sync` controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single Contact Kit large electrical load the user may not need. G006160-0 Touch -Up Paint Kit If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to correctly maintain or touch-up a generator enclosure. G006482-0 -10 KW Scheduled Maintenance Kit Scheduled maintenance kits provide all the items necessary to perform complete G007216-0 -14/18 KW routine maintenance on a Honeywell automatic standby generator (oil not included). G007005-0 Wi-Fi® LP Fuel Level Monitor The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the LP tank fuel level is an important step in verifying the generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify the user when the LP fuel tank is in need of a refill. G007001-0 - 50 AMP Smart Management Module Smart Management Modules (SMM) are used to optimize performance of a standby G007006-0 -100 AMP generator. It manages large electrical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using SMM's can reduce the overallsize and cost of the system.. G007169-0 - 4G LTE Mobile Link°Cellular The Mobile Linkfamily of Cellular Accessories allows users to monitorthe status of the G007170-0 - WI-FI/ Accessories generator from anywhere in the world, using a smartphone, tablet, or PC. Easily access ETHERNET information such as the current operating status and maintenance alerts. Users can connect an account with an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. Dimensions and UPCs Generac Power Systems, Inc. S45 W29290 Hwy 59 Waukesha, WI.53187 1.855.GEN.INFO www.honeywellgenerators.com G007179-0 696471077209 G007229-0 696471082593 G007230-0 696471082807 ©Generac Power Systems, Inc. All rights reserved. Specifications subject to change without notice. The Honeywell trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representation orwarranties with respecttothis product.This product is manufactured by Generac Power Systems, Inc., Waukesha, WI.53189. A0000973580 I RevA 1 10/2020. Honeywell