Loading...
FIR2021-0088+Fire_Sprinkler_Equipment_Specification_Sheets+8.4.2021_1.48.56_PM+2339340t••••••. cosco '0000o" Fire Protection FIRE PROTECTION MATERIAL SUBMITTAL SWEDISH EDMONDS 21610 76TH AVE W EDMONDS WA 98026 Fire Protection Contractor Cosco Fire Protection 4308 South 1315t PI. Tukwila, Washington 98168 (206) 438-3360 Fax: (206) 438-3356 JOB # 25SS8817 ---------------------------� WASHINGTO-N STATE ■ CERTIFICATE OF COMPETENCY ■ FIRE PROTECTION SPRINKLER SYSTEMS ■ Jeffrey David Johnson ■ 7915-1015-C Level N ■ Cosco Fire Protection, Inc. ■ COSCOFP110NM 00 � o G ■ ■ Expires ■ Signature 12/31/21 ; .. • •• •.. 0 00 00 0.. ::*0000. .�0••00' SECTIONS COSCO Fire Protection TABLE OF CONTENTS 1. PIPE AND FITTINGS a. Schedule 40 Pipe b. Mechanical Tee c. Threaded Fittings d. VicFlex 2. SPRINKLER HEADS a. VK3021 3. HANGERS a. All Thread Rod b. Ring Hangers 0000000. cosco ' • • •• • •' Fire Protection SECTION 1. PIPE AND FITTINGS FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: • ASTM A135, Type E, Grade A (Schedule 10) • ASTM A795, Type E, Grade A (Schedule 40) • NFPA 13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6" receives a proprietary mill coating to ensure a clean, corrosion -resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot -dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. PROJECT: ENGINEER: LOCATIONS: ❑ BLACK 700 South Dock Street info@wheatland.com - Sharon, PA 16146 wheatland.com P 800.257.8182 Follow us on Twitter: F 724.346.7260 @WheatlandTube SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES in. mm in. mm in. mm Ibs./ft. kg/m CRR* Lift 1 �/4 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 1 �/2 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 2�/2 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. * The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES in. mm in. mm in. mm Ibs./ft. kg/m CRR* Lift 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 11/4 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 1'/2 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. * The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 7.0). UL C U` FM APPROVED CONTRACTOR: SPECIFICATION REFERENCE: COMMENTS: ❑ HOT -DIP GALVANIZED DATE: SYSTEM TYPE: WFS-051516 Wheatland Tube A DIVISION OF ZEKELMAN INDUSTRIES CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Ilia 11 ' Irl W.'� nn �_t � ICI FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 x 1/2Y50 x 15 mm through 8 x 47200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Size r x Branch N,-,mna' Size No. Pressure@ DiameterStyle Max.Work Hole 920 Dimensions V*# V T Approx. Weight Each Female Inc hes 2 x /2 (a) a or psi +0.13 • •0 920N 500 1.50 Inches Inches mm mm 2.00 2.53 Inches Inches Inches mm mm mm _ 1.61 5.35 Inc mm 2.75 kg kg 3.1 50 15 3450 38.1 51 64 41 136 70 1.5 3/4 (a) a 920N 500 1.50 1.97 2.53 _ 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 41 136 70 1.5 1 (a) a g20N 500 1.50 1.85 2.53 _ 1.61 5.35 2.75 3.0 25 3450 38.1 47 64 41 136 70 1.4 1 Y4 (a) to 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 11/2 (a) to g20N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 21/2 x 1/2 (a) §a 920N 500 1.50 2.21 2.74 _ 1.82 5.64 2.75 3.0 65 15 3450 38.1 56 70 46 143 70 1.4 3/4 (a) §a 920N 500 1.50 2.18 2.74 _ 1.82 5.64 2.75 3.0 20 3450 38.1 55 70 46 143 70 1.4 920N 500 2.06 2.74 _ 1.82 5.64 2.75 1 (a) §n 1.50 2.9 25 3450 38.1 52 70 46 143 70 1.4 1 V4 t (a) a 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 1 /2 t (a) a 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 1/2(a) 76.1 x 920N 300 1.50 2.22 2.75 _ 2.25 6.46 3.18 3.9 _ 15 2065 38.1 56 70 57 164 81 1.8 3/4 (a) 920N 300 1.50 2.19 2.75 _ 2.25 6.46 3.18 3.9 20 2065 38.1 56 70 57 164 81 1.8 1 (a) 920N 300 1.50 207 2.75 _ 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 57 164 81 1.7 1'/4 (a) a 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 920N 500 2.28 3.00 3.31 1.92 6.29 3.25 3.5 1 1/2 (a) a 2.00 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 3 Y2 (a) a x 920N 500 1.50 2.52 3.05 _ 2.28 6.15 2.75 3.4 _ 80 15 3450 38.1 64 78 58 156 70 1.6 3/4 (a) o 920N 500 1.50 2.49 3.05 _ 2.28 6.15 2.75 3.4 20 3450 38.1 63 78 58 156 70 1.6 1 (a) 920N 500 1.50 2.38 3.06 _ 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 58 156 70 1.6 1'/4 (a) to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32 (b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 920N 500 2.78 3.50 3.56 2.28 6.15 3.25 4.1 1 1/2 (a) to 2.00 3.8 40 (b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2 (a) n 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3 /2 x 2 920N 500 2.50 3.00 _ 3.75 2.44 6.72 3.88 _ 3.8 90 50 3450 63.5 76 95 62 171 99 1.8 TABLE CONTINUED ON PG. 3 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2'h" BSPT clearly on order. § Vds approved for fire protection services n LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_2 ✓ctaulic° REV-0 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical -TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 x 1/2750 x 15 mm through 8 x 47200 x 100mm St, le Max. Work Approx. Size No. Pressure@ Dimensions Weight Each Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. mm 920N kPa 00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 2 4 V2 (a) 0 x 920N 500 1.50 3.03 3.56 _ 2.69 1 7.01 2.75 3.7 _ 100 15 3450 38.1 77 90 68 178 70 1.8 3/4 (a) 0 920N 500 1.50 3.00 3.56 _ 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 68 178 70 1.8 1 (a) 0 920N 500 1.50 2.88 3.56 _ 2.69 7.01 2.75 3.6 25 3450 38.1 73 90 68 178 70 1.8 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 1 Y4 (a) to 920N 500 32 (b) 3450 44.5 78 96 102 68 178 1 76 1.9 1.8 1'/2 (a) to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40 (b) 3450 50.8 83 102 102 68 178 1 83 2.0 1.9 2 (a) to 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 50 3450 63.5 83 102 102 68 178 1 99 2.3 2.1 2'/2 (a) t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 1 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 _ 4.00 2.69 7.34 4.63 _ 6.4 3450 69.9 73 102 68 186 118 2.9 3 (a) t 920 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 1 1/4(a)❑ 108.0 x 920N 500 1.75 3.08 3.78 _ 2.63 7.64 3.05 5.0 _ 32 3450 44.5 78 96 67 194 78 2.3 1'/2 (a)o 920N 500 2.00 3.28 4.00 _ 2.63 7.64 3.25 5.0 40 3450 50.8 83 102 67 194 83 2.3 2 (a) 920N 500 2.50 3.25 4.00 _ 2.63 7.64 4.00 4.0 50 3450 63.5 83 102 67 194 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 3450 69.9 73 102 102 67 194 109 3.6 3.5 3 (a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 5 1 Y2 (a) t 920 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 125 x 40 3450 1 50.8 102 121 121 80 246 94 3.4 3.4 2 (a) t 920 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 50 3450 63.5 102 121 121 80 246 111 3.7 3.6 2'/2 (a) t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm o 920 500 2.75 3.75 _ 4.75 3.16 9.70 4.63 _ 8.0 3450 69.9 95 121 80 246 118 3.6 3 (a) t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 4.50 _ 80 246 135 3.8 4.0 2 133.0 x 920N 500 2.50 3.75 3.17 8.00 3.88 8.0 _ 50 3450 63.5 95 114 81 203 99 3.6 3 920 500 3.50 3.81 5.00 _ 3.00 9.46 5.31 8.0 _ 80 3450 88.9 97 127 76 240 135 1 3.6 TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another t Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2112" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV 0 ✓ctsulic® 11.02_3 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS �Yr Z� V I I W GROOVED OUTLET �Y�Z� V T FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 x 1/2Y50 x 15mm through 8 x 47200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Style Max. Work Approx. Size No. Pressure@ Dimensions Weight Each al Size 920 Diameter T** Thd. Grv. W y Z d..7G hes or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs: Lbs. m 920N kPa -0.00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 3 1 Y2 t 139.7 x 920N 500 2.00 3.78 4.50 _ 3.30 8.23 3.25 7.0 40 3450 50.8 96 114 84 209 83 3.2 920N 500 4.50 _ 3.30 8.23 3.88 2 t 2.50 1 3.75 9.0 50 3450 63.5 95 114 I 84 1 209 99 4.1 6 1 1/4(a) x 920N 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 150 32 (b) 3450 44.5 112 130 130 96 232 83 2.3 2.2 920N 500 4.40 5.13 5.13 3.79 9.15 3.25 5.4 1 Y2 (a) to 2.00 5.1 40 (b) 3450 I 50.8 112 130 130 96 232 83 2.4 2.3 2 (a) tp 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 15 2 Y2 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 76.1 mmn 920 500 2.75 4.15 _ 5.21 3.69 10.51 4.63 _ 8.4 3450 69.9 105 132 94 267 118 3.8 3 (a) t 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 4 (a) to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 500 2.00 97 146 137 94 267 159 4.6 4.6 _ 1 1/2 (a) 159.0 x 920N 4.41 5.13 _ 3.63 9.40 3.25 7.8 40 3450 50.8 112 130 92 239 83 3.5 2 (a) 920N 500 2.50 4.38 5.13 _ 3.63 9.40 3.88 8.0 50 3450 63.5 111 130 92 239 99 3.6 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 108.Omm 920 500 4.50 4.45 _ 5.38 3.63 9.40 6.12 _ 10.0 3450 114.3 113 137 92 239 155 4.5 4 920 500 4.50 3.81 5.75 _ 3.63 9.40 6.25 18.0 _ 100 3450 114.3 96.80 146 92 239 159 8.2 TABLE CONTINUED ON PG. 5 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2/2" BSPT clearly on order. § Vds approved for fire protection services A LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_4 ✓ctaulic° REV-0 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical -TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS IGI 11 1. NE '- F rl 701 ` 1 u Ivl FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 x 1/2750 x 15 mm through 8 x 47200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. Sty le Max. Work Approx. Size No. Pressure@ Dimensions Weight Each Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. mm 920N kPa 00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 4 1 165.1 x 500 920N 1.50 3.88 4.56 - 3.79 9.34 2.75 8.0 _ 25 3450 38.1 99 116 96 237 70 3.6 920N 500 3.79 9.34 3.25 8.4 1 /4n 1.75 4.43 5.13 _ 32 3450 44.5 113 130 96 237 83 3.8 1 /2 (a) to 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 2 (a) t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 3 (a) t o 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 3450 88.9 110 I 140 130 92 267 135 4.6 3.8 4 (a) to 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 3450 I 114.3 97 146 137 92 267 159 4.8 3.8 8 2 (a) t x 920 F 500 1 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 50 3450 I 69.9 138 157 159 122 316 114 5.3 5.3 2 /2 (a) t 920 500 2.75 5.07 6.19 6.19 431 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 76.1 mm n 920 500 2.75 5.25 _ 6.25 431 12.42 4.56 _ 11.6 3450 69.9 133 159 122 316 116 5.3 3 (a) to 920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 80 3450 88.9 135 165 165 122 316 I 135 5.7 5.3 4 (a) to 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings: (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2/2" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV 0 ✓ctsuliiic® 11.02_5 [y_At7:101►&11212109WM:[I]4291111111111UC1111111141&1 11.02 Mechanical -TO Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical -TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. 4z Cv and Kv Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for Cv,K Values: �P = Qz Where: OP = Q2 Where: O C zz Q= Flow (GPM) 2 Q= Flow W/hr) K 4P = Pressure Drop (psi) V AP = Pressure Drop (Bar) Q = C x AP C = Flow Coefficient Q = K, x pp K =Flow Coefficient Exaggerated for clarity t Hazen -Williams coefficient of friction is 120. * Pipe with a wall thickness of 0.165in./4.2mm. 1" FireLock- Innovative Groove System (IGS) outlet www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11�'itaullC� 11.02_6 REV-0 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical -TO Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size Outlet Size Pipe Agency Rated Working Pressures — psi/kPa Nominal Si e DiameterApproval Actual Outside Vds lnchers/mm Inches/mm Inches/mm Schedule LIL LILC (Style 920) (Style 920N) 21 /2 - 6 2.875 - 6.625 All 10, 40 400 400 400 290 232 362 65 - 150 73.0 - 168.3 2.875 - 4.500 All DF 2755 2755 2755 1999 1599 2496 21/2 - 4 300 300 300 290 232 362 65 - 100 73.0 - 114.3 2065 2065 2065 1999 1599 2496 21/2 - 4 2.875 - 4.500 All SF 300 300 300 290 232 362 65 - 100 73.0 - 114.3 2065 2065 2065 1999 1599 2496 6 6.625 3, 4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30, 40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 1 10,40 400 145 200 219.1 10 2755 1000 8 8.625 3,4 300 250 145 200 219.1 30, 40 2065 1724 1000 145 8 8.625 3,4 300 300 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super -Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic -Tap II hole cutting tool is designed for use with the Style 931 Vic -Tap II Mechanical-T unit, 4 - 8"/100 - 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic -Ball Valve. The Vic -Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500psi/3450kPa. The Style 931 Vic -Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 57125mm, 67150mm and 87200 mm diameter pipe. The Style 931 comes with a 21/2765mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. _I 1 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV 0 ✓ctaulic® 11.02_7 SPF/RNVIL' DUCTILE IRON THREADED FITTINGS Z ANVIL FIG. 3201 90' Elbow I I I I I I A' I I FIGURE I Nominal Size Maximum Dimension A Approx. Wt. Each Working Pressure In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 500 1.50 0.62 20 3450 38.10 0.28 1 t/4 500 1.75 0.90 32 3450 44.45 0.41 1 /2 500 1.94 1.20 40 3450 49.276 0.54 2 500 2.25 1.85 50 1 3450 57.15 1 0.84 ♦ — Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 iDus <S> ;TED APPROVED Approval Details and Limitations, iebsite at www.anvilintl.com or i Anvil', Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: ❑ Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL MALLEABLE IRON THREADED FITTINGSNvi Class 150 (Standard) FIG. 3105R Reducing Tee 2 3 1 1x2x3 FIGURE 3105R - REDUCING TEE Nominal Size Dimensions Approx. 1 1 2 1 3 A B C Wt. Each In. (mm) In. (mm) In. (mm) In. (mm) Lbs. (kg) 'A 0.97 0.97 0.98 0.24 8 24.64 24.64 24.89 0.11 3/8 1.04 1.04 1.03 0.27 '/2 '/2 10 26.42 26.42 26.16 0.12 15 15 3/4 1.22 1.22 1.20 0.37 20 30.99 30.99 30.48 0.17 1 1.36 1.36 1.26 0.49 25 34.54 34.54 32.00 0.22 '/2 1.20 1.12 1.22 0.38 '/2 15 30.48 26.16 28.45 0.17 15 3/4 1.31 1.22 1.31 0.45 20 33.27 28.45 33.27 0.20 '/4 1.05 1.05 1.08 0.36 3/4 8 26.67 26.67 27.43 0.16 20 3/8 1.12 1.12 1.13 0.39 3/4 10 28.45 28.45 28.70 0.18 20 '/2 1.20 1.20 1.22 0.43 15 30.48 30.48 30.99 0.20 1 1.45 1.45 1.37 0.62 25 36.83 36.83 28.45 0.28 '/4 1 1.50 1.18 1.50 0.63 8 25 38.10 29.97 38.10 0.29 '/2 1.26 1.12 1.36 0.48 1 15 32.00 28.45 34.54 0.22 25 '/2 3/4 1.37 1.22 1.45 0.56 15 20 34.80 28.45 34.54 0.25 1 1.50 1.36 1.50 0.67 25 38.10 34.54 38.10 0.30 C VI. US FM LISTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.anvilintl.00m or contact an Anvil® Sales Representative. Dimensions: Fittings: ASME B16.3 Unions: ASME B16.39 Bushings/Plugs: ASME B16.14 Material: ASTM A-197 Finish: Black or Hot Dip Galvanized per ASTM Al53 Class A Threads*: NPT per ASME B1.20.1 Pressure Ratings: Fittings: ASME B16.3 Unions: ASME B16.39 Bushings/Plugs: ASME B16.14 Pressure Testing: All malleable iron fittings are tested for through wall porosity using an air under water process. Agency Approvals: All malleable iron fittings and unions are UL/ULC Listed and FM Approved. * British Standard threading per BS 21 available upon request. PROJECTO•APPROVAL Project: ❑ Approved Address: ❑Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPHMI-1.15 SPF/RNVIL MALLEABLE IRON THREADED FITTINGSNvi Class 150 (Standard) FIG. 3105R Reducing Tee 1 x 2 x 3 FIGURE ■REDUCIPJG TEE Nominal Size Dimensions Approx. 1 1 2 3 A B IC Wt. Each In. (mm) In. (mm) In. (mm) In. (mm) Lbs. (kg) '/2 1.26 1.20 1.36 0.53 15 32.00 30.48 34.54 0.24 3/4 3/4 1.37 1.31 1.45 0.61 20 20 34.80 33.27 36.83 0.28 1 1.50 1.45 1.50 0.71 25 38.10 36.83 38.10 0.32 3/8 1.18 1.18 1.27 0.57 10 29.97 29.97 32.26 0.26 1 '/2 1.26 1.26 1.36 0.62 25 15 32.00 32.00 34.54 0.28 3/4 1.37 1.37 1.45 0.69 1 20 28.45 28.45 36.83 0.31 1'A 1.67 1.67 1.58 0.94 32 42.42 42.42 40.13 0.43 1'/2 1.80 1.80 1.65 1.07 40 45.72 45.72 41.91 0.49 2 2.02 2.02 1.73 1.45 50 51.31 51.31 43.94 0.66 1 1.58 1.36 1.67 0.82 '/ 25 40.13 34.54 42.42 0.37 1'A 1.75 1.53 1.75 0.95 32 44.45 38.86 44.45 0.43 3/4 1.45 1.31 1.62 0.75 20 36.83 33.27 41.15 0.34 3/ 1 1.58 1.45 1.67 0.87 20 25 40.13 36.83 42.42 0.39 1'/4 1'A 1.75 1.62 1.75 1.00 32 44.45 41.15 44.45 0.45 '/2 1.34 1.26 1.53 0.74 15 34.04 32.00 38.86 0.34 3/4 1.45 1.37 1.62 0.82 1 20 36.83 28.45 41.15 0.37 1 1.58 1.50 1.67 0.94 25 40.13 38.10 42.42 0.43 1'A 1.75 1.67 1.75 1.08 32 44.45 42.42 44.45 0.49 FIGURE ■REDUCIPJG TEE Nominal Size Dimensions Approx. 1 2 3 A B ( Wt. Each In. (mm) In. (mm) In. (mm) In. (mm) Lbs. (kg) 3/8 1.26 1.26 1.44 0.78 10 32.00 32.00 36.58 0.35 '/2 1.34 1.34 1.53 0.84 15 34.04 34.04 38.86 0.38 3/4 1.45 1.45 1.62 0.92 1'/4 1'/4 20 36.83 36.83 41.15 0.42 32 32 1 1.58 1.58 1.67 1.04 25 40.13 40.13 42.42 0.47 1'/2 1.88 1.88 1.82 1.34 40 47.75 47.75 46.23 1 0.61 2 2.10 2.10 1.90 1.65 50 53.34 53.34 48.26 0.75 '/2 1'/2 1.94 1.66 1.94 1.24 15 40 49.28 42.16 49.28 0.56 3/4 1.50 1.26 1.69 0.86 3/4 20 38.10 32.00 42.93 0.39 20 1'/2 1.94 1.75 1.94 1.29 40 49.28 44.45 49.28 0.59 1 1.65 1.50 1.80 1.08 25 41.91 38.10 45.72 0.49 1 1'A 1.82 1.67 1.88 1.23 25 32 46.23 42.42 47.75 0.56 1'/2 1.94 1.80 1.94 1.35 40 49.28 45.72 49.28 0.61 3/4 1.52 1.45 1.75 1.04 20 38.61 36.83 44.45 0.47 1 1.65 1.58 1.80 1.17 1'/2 25 41.91 40.13 45.72 0.53 40 1'/4 1'A 1.82 1.75 1.88 1.32 32 32 46.23 44.45 47.75 0.60 1'/2 1.94 1.88 1.94 1.45 40 49.28 47.75 49.28 0.66 2 2.10 2.10 1.90 1.82 50 53.34 53.34 48.26 0.83 '/2 1.41 1.41 1.66 1.04 15 35.81 35.81 42.16 0.47 3/4 1.52 1.52 1.75 1.14 20 38.61 38.61 44.45 0.52 1'/2 1 1.65 1.65 1.80 1.27 40 25 41.91 41.91 45.72 0.58 1'A 1.82 1.82 1.88 1.43 32 46.23 46.23 47.75 0.65 2 2.16 2.16 2.02 1.89 50 54.86 54.86 51.31 0.86 SPF7MI-1.15 SPF/RNVIL MALLEABLE IRON THREADED FITTINGSNvi Class 150 (Standard) FIG. 3105R Reducing Tee 1 x 2 x 3 FIGURE 3105R - REDUCING TEE Nominal Size Dimensions Approx. 1 1 2 T 3 A B C Wt. Each In. (mm) In. (mm) In. (mm) In. (mm) Lbs. (kg) '/2 2 2.25 1.88 2.25 1.89 15 50 57.15 47.75 57.15 0.86 3/4 2 2.25 1.97 2.25 1.93 20 50 57.15 50.04 57.15 0.88 1 1.81 1.75 1.87 1.39 1 25 45.97 44.45 47.50 0.63 25 2 2.25 2.02 2.25 2.00 50 57.15 51.31 57.15 0.91 1'A 1.90 1.75 2.10 1.64 32 48.26 44.45 53.34 0.74 1'/4 1'/2 2.02 1.88 2.16 1.80 32 40 51.31 47.75 54.86 0.82 2 2.25 2.10 2.25 2.09 50 57.15 53.34 57.15 j.95 1 1.73 1.65 2.02 1.57 25 43.94 41.91 51.31 0.71 2 1'A 1.90 1.82 2.10 1.71 50 1 '/2 32 48.26 46.23 53.34 0.78 1'/2 2.02 1.94 2.16 1.88 40 51.31 49.28 54.86 0.85 2 2.25 2.16 2.25 2.21 50 57.15 54.86 57.15 1.00 '/2 1.49 1.49 1.88 1.53 15 37.85 37.85 47.75 0.69 3/4 1.60 1.60 1.97 1.63 20 40.64 40.64 50.04 0.74 1 1.73 1.73 2.02 1.78 2 25 43.94 43.94 51.31 0.81 1'A 1.90 1.90 2.10 1.97 50 32 48.26 48.26 53.34 0.89 1'/2 2.02 2.02 2.16 2.12 40 51.31 51.31 54.86 0.96 2'/2 2.60 2.60 2.39 3.15 65 66.04 66.04 60.71 1.43 FIGURE 3105R - REDUCING TEE Nominal Size Dimensions Approx. 1 2 3 A B ( Wt. Each In. (mm) M In. (mm) In. (mm) In. (mm) Lbs. (kg) 1/4 1.74 1.74 2.32 2.67 20 44.20 44.20 58.93 1.21 1 1.87 1.87 2.37 2.84 25 47.50 47.50 60.20 1.29 2'/2 2'/2 l'A 2.04 2.04 2.45 3.09 65 65 32 51.82 51.82 62.23 1.40 1'/2 2.16 2.16 2.51 3.29 40 54.86 54.86 63.75 1.49 2 2.39 2.39 2.60 3.65 50 60.71 60.71 66.04 1.66 2 2 2.52 2.25 2.89 3.88 50 50 64.01 57.15 73.41 1.76 3/4 1.87 1.87 2.61 3.72 20 47.50 47.50 66.29 1.69 1 2.00 2.00 2.66 3.96 25 50.80 50.80 67.56 1.80 3 1'A 2.17 2.17 2.74 4.23 80 3 32 55.12 55.12 69.60 1.92 1'/2 2.29 2.29 2.80 4.45 80 40 58.17 58.17 71.12 2.02 2 2.52 2.52 2.89 4.90 50 64.01 64.01 73.41 2.22 21/2 2.83 2.83 2.99 5.69 65 71.88 71.88 75.95 2.58 2 2.74 2.74 3.41 7.52 50 69.60 69.60 86.61 3.41 4 4 21/2 3.05 3.05 3.51 8.51 100 100 65 77.47 77.47 89.15 3.86 3 3.30 3.30 3.60 9.25 80 83.82 83.82 91.44 4.20 SPF7MI-1.15 SPF/RNVIL' DUCTILE IRON THREADED FITTINGS Z ANVIL FIG. 3221R Reducing Coupling FIGURE 3221R - REDUCING COUPLING Nominal Size Maximum Dimension A Approx. Wt. Each Working Pressure In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 x /2 500 1.69 0.39 25 x 15 3450 42.92 0.18 1 x 3/4 500 1.69 0.53 25 x 20 3450 42.92 0.24 — Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 C UL US <S> LISTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil', Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: ❑ Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL' MALLEABLE IRON THREADED FITTINGS Z &NV L Class 150 (Standard) FIG. 3124 Cap rF,,4 E��� FIGURE I • Nominal Size Dimension A Approx. Wt. Each In. (mm) In. (mm) Lbs. (kg) '/8A 0.53 0.03 6 13.46 0.01 'AA 0.63 0.05 8 16.00 0.02 3/8A 0.74 0.07 10 18.80 0.03 '/2 0.87 0.11 15 22.10 0.05 3/4 0.97 0.18 20 24.64 0.08 1 1.16 0.30 25 29.46 0.14 1'A 1.28 0.44 32 32.51 0.20 1'/2 1.33 0.55 40 33.78 0.25 2 1.45 0.85 50 36.83 0.39 2'/2 1.70 1.49 65 43.18 0.68 3 1.80 2.20 80 45.72 1.00 3'/2 1.90 3.02 90 48.26 1.37 4 2.08 3.79 100 52.83 1.72 6 2.55 8.77 150 64.77 3.98 A - Supplied in Steel only (Black and Galvanized). C UL US FM LISTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.anvil,nti.com or contact an Anvil' Sales Representative. Dimensions: Fittings: ASME B16.3 Unions: ASME B16.39 Bushings/Plugs: ASME B16.14 Material: ASTM A-197 Finish: Black or Hot Dip Galvanized per ASTM Al53 Class A Threads*: NPT per ASME B1.20.1 Pressure Ratings: Fittings: ASME B16.3 Unions: ASME B16.39 Bushings/Plugs: ASME B16.14 Pressure Testing: All malleable iron fittings are tested for through wall porosity using an air under water process. Agency Approvals: All malleable iron fittings and unions are UL/ULC Listed and FM Approved. * British Standard threading per BS 21 available upon request. PROJECT Project: ❑ Approved Address: ❑ Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/MI-1.15 Victaulic° VicFle)Jm Sprinkler Fittings ✓ctaullcg Series AH2 and AH2-CC Braided Flexible Hoses 10.85 Vic Series AH2 Series AH2-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component • Series AH2 1"/DN25 Nominal ID Braided Hose: 31, 36, 48, 60, 727790, 915, 1220, 1525, 1830mm. Note: length includes adapter nipple and 5.75/140 mm straight reducer. • Series AH2-CC 1"/DN25 Nominal ID Braided Hose: 31, 36, 48, 60, 727790, 915, 1220, 1525, 1830 mm. Note: length includes captured coupling and 5.75/140 mm straight reducer. • Sprinkler Reducers: • Sprinkler Connections: 1/2 and 3/4715 and 20mm • Straight Lengths: 5.75, 9, 137140, 230, 330 mm • 90' Elbows: • Short (typically used with concealed sprinklers) • Long (typically used with recessed pendent sprinklers) • Low Profile Short (for use with Style AB5, AB11, AB12, ABBA and ABMM Bracket) • Low Profile Long (for use with Style AB5, AB11, AB12, ABBA and ABMM Bracket) • Inlet Connections: • P725 mm Grooved IGS • P725mm NPT or BSPT adapter nipples for attaching to pipe and fittings outlined in NFPA standards. • 3/4720mm NPT or BSPT adapter nipples available for VdS. • 1 1/47 32 mm BSPT adapter nipples available for LPCB. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. 1 �ctauliic® victaulic.com 1.0 PRODUCT DESCRIPTION (Continued) • Brackets: • Style A131 for suspended and hard -lid ceilings and sidewalls, allows installation before most ceiling tiles in place • Style A132 for suspended and hard -lid ceilings and sidewalls, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style A133 for surface mount applications, wood, metal and block walls, or ceilings • Style A134 for hard -lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style A135 for hard -lid ceilings and sidewalls, allows for vertical sprinkler adjustment • Style A137 for suspended and hard -lid ceilings • Style A137 Adjustable for suspended and hard -lid ceilings • Style A138 for hard -lid ceilings with CD 60/27 profile metal studs (regionally available) • Style A139 for hard -lid ceilings with hat furring channel grid systems • Style AB10 for Armstrong@ TechZoneTM ceilings • Style AB11 for lay -in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 90' low profile elbows) • Style AB12 for suspended and hard -lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 47100mm. • Style ABBA bracket for suspended, exposed, and hard -lid ceilings • Style ABMM bracket for surface mount and stand off -mount applications, wood, metal and block walls, or ceilings and hard -lid ceilings Maximum Working Temperature • 225°F/1070C Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) • 1.4 MPa (CCCf Approved) Connections • To adapter nipple (inlet) via • 1725.4mm Grooved IGS • 1725.4mm NPT or BSPT male thread • 3/4/20 mm BSPT male thread (VdS only) • 11/4732 mm BSPT male thread (LPCB only) • To sprinkler head (outlet) via 1/2" or 3/4/15 mm or 20 mm Minimum Bend Radius • 7"/178mm (FM/CCCf Approval) • 2751 mm (cULus Listed) • 3776.2 mm (VdS/LPCB Approved) Maximum Allowable Sprinkler K-Factors • FM (1/2"/15 mm reducer) K5.6/8,1 (S.I.), (3/4/20 mm reducer) K14.0/20,2 (S.I.) • cULus (1/2715 mm reducer) K8.0/11,5 (S.I.), (3/4 /20 mm reducer) K14.0/20,2 (S.I.) • VdS/LPCB (V2715mm reducer) K5.6/8,1 (S.I.), (3/4"/20mm reducer) K8.0/11,5 (S.I.) 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. virtaulir_rnm 2 ✓ctaUliic' victaulic.corn 2.0 CERTIFICATION/LISTINGS FM C uU en oS vds LPCB �(( CNHaI %N NOTE • The UicFlex Series AH2 Hose has been tested and evaluated by Spears@ for acceptable use with Spears@ CPVC Products and is therefore covered under the Spears@ FlameGaurd@ Installer Protection Plan. 3.0 SPECIFICATIONS — MATERIAL Series AH2 • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (1/2 Y15 mm or 3/4720 nrl Carbon Steel, Zinc -Plated • Low Profile Elbows: Ductile Iron, Zinc -Plated Brackets: Carbon Steel, Zinc -Plated Series AH2-CC • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Coupling Retainer Ring: Polyethelene • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (1/2 Y15 mm or 3/4720 nrl Carbon Steel, Zinc -Plated • Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: • Orange enamel (North America, Asia Pacific). • Red enamel (Europe). • Hot dipped galvanized. Gasket:' • Grade "E" EPDM (Type A) Fire Lock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. • Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. • Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. vid4midir rnm 3 ✓ctal lac' victaulic.com 4.0 DIMENSIONS Product Details - Series AH2 Braided Hose 2 B 5 1 6 7 3 4 C B Hose Length Dimensions Hose Length inches mm A inches mm B inches mm 31/790 25.3/641 31/790 36/915 31.3/794 36/915 48/1219 42.3/1073 48/1220 60/1525 54.3/1378 60/1525 72/1830 66.3/1683 72/1830 Series AH2-CC Braided Hose 1 6 8 34 A _ B Hose Length inches mm A inches mm B inches mm 31/790 24.5/622 29.8/757 36/915 29.5/749 34.8/884 48/1219 41.5/1054 46.8/1189 60/1525 53.5/1359 58.8/1494 72/1830 65.5/1664 70.8/1798 Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Adapter Nipple 6 Braid 7 Collar/Weld Fitting 8 Sleeve Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Captured Coupling 6 Braid 7 Collar/Weld Fitting 8 Sleeve 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com il ✓ctauliic' victaulic.com 4.0 DIMENSIONS (Continued) Standard Reducer 5.757140 mm straight reducer Optional Reducers HMWEE��111 9.0"/229 mm straight reducer 13.07330 mm straight reducer 2.62"/ 66.5 mm 4.83"/ 122.7 mm Short 90' elbow reducer 2.62/ 66.5 mm 6.57"/ 166.9 mm Long 90' elbow reducer NOTE • The Short 90' elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. • FM/VdS Approved only. Low Profile 1.4"/ 36 mm 0 4.597 1 116 mm 1.4"/ 36 mm Short 90' elbow reducer Long 90° elbow reducer NOTE • Style AB11: When low profiles elbows are used with the Style AB11 bracket, the Low Profile Short Elbow is typically used with concealed sprinklers while the Low Profile Long Elbow is typically used in the installation of recessed pendent sprinklers. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. vid4midir rnm 5 ✓ctsulic' vir+nl Jir rnm 4.1 DIMENSIONS WcRex Brackets Style AB1 • Suspended Ceilings • Hard -Lid Ceilings (FM Only) Item Description 1 24"/610 mm or 48'71219 mm Square Bar 2 Patented Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved, cULus listed Style AB2 • Suspended Ceilings • Hard -Lid Ceilings Item Description 1 24V 10 mm or 48'71219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved, cULus listed Style AB3 • Surface Mount Applications • FM/LPCB Approved 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. vir+midir rnm 0 ✓ct:auliic' victaulic.com 4.2 DIMENSIONS VicFlex Brackets Style AB4 • Hard -Lid Ceilings with Hat furring channel grid system Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket for Hat Furring Channel NOTE • Both sizes FM/VdS/LPCB Approved, cULus listed. Style AB5 • Hard -Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved, cULus listed. Style AB7 • Suspended Ceilings • Hard -Lid Ceilings Item Description 1 24"/610 mm or 48'/1219 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved. Style AB7 Adjustable • Suspended Ceilings • Hard -Lid Ceilings Item Description 1 700 mm or 1400 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket (adjustable) NOTE • Both sizes FM/VdS/LPCB Approved. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. vit4midir rnm 7 ✓ctsulic' victaulic.com 4.3 DIMENSIONS VicFlex Brackets Style AB8 • Hard -Lid Ceilings Item Description 1 700 mm or 1400 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved. Style AB10 • Suspended ceilings • Armstrong® TechZoneTM Item Description 1 6'7152 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE • FM/VdS/LPCB Approved, cULus listed. Style AB11 • Suspended ceilings • Hard -Lid ceilings Item Description 1 24V 10 mm or 48'71219 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE • FM/VdS Approved, cULus listed. Style AB12 • Suspended ceilings • Hard -Lid ceilings Item Description 1 Style AB12 Bracket Body 2 #2 Square Drive Set Screw NOTE • FM/VdS Approved. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. vid4midir rnm i ✓ctauliic' victaulic.com 4.3 DIMENSIONS (CONTINUED) VicFlex Brackets Style ABBA • Floor -above mount • Cantilever mount • Temporary mount in exposed ceilings Item Description 1 Style ABBA M unting Plate 2 Style ABBA Square Bar Cap Screw, Serated Flange, M6 x 1 x 20, 3 T25 Torx Drive Recessed 4 Style ABMM Bracket Body Cap Screw, Serated Flange, M6 x 1 x 15.24, 5 T25 Torx Drive Recessed Style ABMM • Surface mount • Stand-off mount Item Description 1 Style ABMM Bracket Body Cap Screw, Serated Flange, M6 x 1 x 15.24, 2 T25 Torx Drive Recessed 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 9 ✓ctaUliic' victaulic.com 4.4 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB1 Bracket A Bracket See Chart Assembly 21/8"/60 mm 2"A6768 mm Style AB1 max, hole max. hole 2"/51 mm 21/s"/60 mm E 4.4"/ min. hole min. hole 113mm 1.7"/43 mm Typical ceiling grid am Finished See note ceiling face 247610 mm or V27 V38 48"/1219 mm on Pendent Cpntpr Hose Clearance Chart Straight Reducer Long Elbow Short Elbow V2707 V3802 V2707 V3802 3/4" 1/2" 3/a" 1/2' V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess 3/4' Max Recess 1/2" Max Recess 3/4" Max Recess 1/2' Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm "R" Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 _ "A" Minimum Required 8.6 10.1 9.6 11.1 13.6 15.1 5.8 5.8 Installation 218 269 244 281 345 383 147 147 Space NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 0 2019 Victaulic Company. All rights reserved. vid4midir rnm 10 ✓ctauliic' 4.5 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket p= Stud 1�11 oeYrr .11l d 1f A See Chart 1.8 2'Md768 mm RV/60 mm R.760 mm 45 mm max. hole max. hole max. hole RV/60 mm 2751 mm 2751 mm a min. hole min. hole min. hole 1 I I I f Finished ceiling Hose Clearance Chart Straight Reducer V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 3/4" 1 20mm 1/2' 1 13mm 3/4" 1 20mm 3/4" 1 20mm 1h" 1 13mm 3/4" 1 20mm 3/4" 1 20mm 1/2" 1 13mm 3/4" 1 20mm Max Recess" Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R" Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 "A" Minimum Required 6.2 7.6 6.1 7.2 8.6 7.1 11.2 12.6 11.1 Installation 158 193 155 183 218 180 285 320 282 Space "R" Minimum Bend Radius "A" Minimum Required Installation Space Hose Clearance Chart Long Elbow Short Elbow V2707 V2709 V3802 3/4" 1 20mm 3/4!' 1 20mm 1/2" 1 13mm Max Recess Sidewall Max Recess inches inches inches mm mm mm 3.3 3.6 3.3 84 91 84 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 11 ✓ctaulil virtni lir rnm 4.6 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB4 Bracket 00 A 23/8760 mm 2%768 mm See Chart max. hole max. hole 2751 mm 23/8"/60 mm min. hole min. hole /sVI5.9mm Typical Typical finished ceiling tile ceiling face See note Typical 167406 mm - 7/8"/23 mm V27 V38 24"/610 mm on Center Typical pendent ceiling and Hose Clearance Chart Straight Reducer Long Elbow Short Elbow V2707 V3802 V2707 V3802 3/4' 1/i' 3/a" 3hil V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess 3/4" Max Recess 1/2" Max Recess 34,' Max Recess MY' Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm "R"Minimum 2.0 3.0 3.0 7.0 7.0 Bend Radius 50 80 80 175 175 _ "A" Minimum Required 8.8 10.2 9.8 11.2 13.8 15.2 8.0 5.9 Installation 224 259 249 285 351 386 203 150 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 12 ✓ctSU1ilc' virtaldir rnm 4.7 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB5 Bracket See Chart Bracket Assembly R.760 mm 21N768 mm 23W760 mm StylfAB� 7 max. hole max. hole max. hole mm2751 mm R.760 mm 2751 mm min. hole min. hole min. hole m 2x4" ii ii iMetalstud IAl/ Finished 15.9 mm ceiling face Drywall 16"/406 mm Stud C/C V27 V38 V27 Pendent Sidewall Hose Clearance Chart Straight Reducer "V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 3/4" 1 20mm 1/2" 1 13 mm 3/4" 1 20mm 3/4" 1 20mm 1/2" 1 13 mm 3/4" 1 20mm 3/4" 1 20mm 1/2' 1 13 min 3/a" 1 20mm Max Recess" Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R" Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 "A" Minimum Required 6.0 7.7 6.1 7.0 8.7 7.1 11.0 12.7 11.1 Installation 158 196 155 178 221 180 279 323 282 Space Hose Clearance Chart Long Elbow V2707 V3802 V2709 3/4"120mm 1/2"113mm 3/a"120mm Max Recess Max Recess Sidewall inches inches inches mm mm mm "R" Minimum _ Bend Radius "A" Minimum Required 3.5 4.9 3.6 Installation 89 124 91 Space Low -Profile Long Elbow Short Elbow V3802 V3802 1/i' 1 13 mm 1/2" 1 13 mm Max Recess Max Recess inches inches mm mm 2.9 3.3 74 84 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 13 ✓ctsulic' victaulic.com 4.8 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) 21/8760 mm 21Y,6'/68 mm 11 Bracket max. hole max. hole Assembly 2751 mm 28/8760 mm A Style AB I min. hole min. hole See Chart 3.r 76 mm rr {r 1.7743 mm Finished Typical 5/8"/15.9 mm ceiling face ceiling grid Typical ceiling the See Note 247610 mm or V27 V38 4871219 mm on center Pendent Hose Clearance Chart Low -Profile Low -Profile Long Elbow Short Elbow V2707 V3802 3W 120mm 1h" 1 13mm Max Recess" Max Recess inches inches mm mm "A"Minimum Required 4.0 3.9 Installation 102 99 Space NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 14 ✓ctauliiic' 4.9 DIMENSIONS Clearances Style AB12 and ABBA Bracket Suspended Ceiling Grid with Recessed Sprinkler with Low Profile Short Elbow Squat Yi 3 Typical Ceiling V2707 h"/12.7 mm MAX. RECESS Low Profile Low Profile Dimension Short Elbow Lone Elbow Suspended Ceiling Grid with Recessed Sprinkler and Straight 5.75/140 mm Reducer Square I Nominal le 14"/355.6 V. 3 W"_ V2707 W/19 mm MAX. RECESS Standard Standard Standard Short Elbow I Lone Elbow Straieht Reducer 3/a'/19mm 3/a%19mm 3/a'/19mm 3/a'/19mm 3/4'/19mm Recessed* Concealed Recessed Concealed Recessed Concealed Recessed Concealed Recessed Concealed inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm Minimum Required 4.0 5.5 5.6 7.2 5.9 7.5 7.7 9.3 15.0 16.6 A Installation Space 101.6 139.7 142.2 182.9 149.9 190.5 195.6 236.2 381.0 421.6 Distance from Top of B Typical Ceiling Tile to 0.5 2.0 1.5 1.5 1.5 1.5 3.0 3.0 3.0 3.0 Bottom of Gate 12.7 50.8 38.1 38.1 38.1 38.1 76.2 76.2 76.2 76.2 * Adjustability will be limited Style ABMM Bracket Stand-off Dimensions 56 mm i 3.93Y 2.94"/ 100 mm /p 75 mm 0.28"/ 13.947O m� O i 100mm 7mm 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 15 ✓ctsulic' victaulic.com 4.10 DIMENSIONS Clearances Style A133 and ABMM Bracket Surface Mount Application with Recessed Sprinkler 2751 mm min. hole Hose Clearances inches inches inches inches inches inches inches inches inches inches Dimension mm mm mm mm mm mm mm mm mm mm WallThickness 2 4 6 8 10 2 4 6 8 10 "A" 50 100 150 200 250 50 100 150 200 250 Outlet Length 5.75 1 9 1 13 5.75 9 13 9 13 13 13 5.75 9 13 5.75 9 13 9 13 13 13 "B" 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 146.1 228.6 330.2 146.1 228.E 330.2 228.6 330.2 330.2 330.2 Hose Clearance 11.6 14.8 18.8 9.6 12.8 16.8 10.8 14.8 12.8 10.8 12.6 15.8 119.8 10.6 13.8 17.8 11.8 15.8 13.8 11.8 T" 294 376 1 478 243 325 427 275 376 325 1 275 319 402 1503 268 351 452 300 402 351 300 Bend Radius 7 8 "R" 1 200 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 16 ✓ctalulic' victaulic.com 5.0 PERFORMANCE — FRICTION LOSS DATA c@us Series AH2 and AH2-CC Braided Hoses with Straight 5.757140 mm Reducers LISTED Style AB1, AB2, AB4, AB5 and AB10 Brackets Maximum Equivalent Length Number of of 1733.7 mm 90' Bends at 2751 Trim Sch. 40 Pipe (C=120) Bend Radius inches/mm inches/mm/type feet/meters 31/790 1/z"/15/Straight 16/4.9 4 4 3/4"/20/Strai ht 17/5.2 36/915 1/2"/15/Straight 21 /6.4 5 3/4"/20/Straight 23/7.0 5 48/1220 1/z"/15/Straight 32/9.8 8 3/4"/20/Strai ht 37/11.3 8 60/1525 1/z"/15/Straight 46/14.0 10 3/4"/20/Straight 46/14.0 10 72/1830 1/z'/15/Straight 55/16.8 3/4"/20/Straight 53/16.2 12 12 c & us Series AH2 and AH2-CC Braided Hose with 90' Low Profile Elbows LISTED Style AB11 VicFlex Bracket Maximum Equivalent Length Number of of 1733.7 mm 90' Bends at 2751 Trim Sch. 40 Pipe Bend Radius inches/mm inches/mm feet/meters 31 /790 1/z'715 24/7.3 4 4 3/4'720 24/7.3 36/915 1/z"/15 26/7.9 5 5 3/4"/20 28/8.5 48/1220 1/z"/15 43/13.1 8 3/4'720 42/12.8 8 60/1525 1/z"/15 49/14.9 10 3/4"/20 50/15.2 10 72/1830 1/z"/15 65/19.8 12 3/4'720 63/19.2 12 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 17 ✓ctauliic' victaulic.com 5.0 PERFORMANCE — FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2751 mm center line bend radius Length of Stainless Steel Flexible Outlet 1 2 3 4 5 6 7 8 9 10 11 12 Hose Size Bend Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends inches/ inches/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ mm mm meters meters meters meters meters meters meters meters meters meters meters meters 1/2"/15 8.5/2.6 11.0/3.4 13.0/4.0 16.0/4.9 N.A N.A N.A N.A N.A N.A N.A N.A 31/790 3/4720 10.0/3.0 12.5/3.8 14.0/4.3 17.0/5.2 N.A N.A N.A N.A N.A N.A N.A N.A 1/2 /15 13.5/4.1 16.0/4.9 18.0/5.5 19.0/5.8 21.0/6.4 N.A N.A N.A N.A N.A N.A N.A 36/915 3/4'720 14.0/4.3 17.0/5.2 19.5/5.9 20.0/6.1 23.0/7.0 N.A N.A N.A N.A N.A N.A N.A 1/2 /15 15.5/4.7 17.0/5.2 19.5/5.9 20.0/6.1 21.0/6.4 22.0/6.7 28.0/8.5 32.0/9.8 N.A N.A N.A N.A 48/1220 3/4720 17.0/5.2 19.0/5.8 21.5/6.6 24.5/7.5 26.0/7.9 27.0/8.2 30.0/9.1 37.0/11.3 N.A N.A N.A N.A 1/2 /15 1 21.5/6.6 24.0/7.3 27.0/8.2 28.5/8.7 30.0/9.1 31.0/9.4 37.0/11.3 42.0/12.8 44.0/13.4 46.0/14.0 N.A N.A 60/1525 3/4720 23.0/7.0 24.0/7.3 28.0/8.5 29.5/9.0 30.5/9.3 31.0/9.4 38.0/11.6 42.0/12.8 44.0/13.4 46.0/14.0 N.A N.A 1/2/15 30.0/9.1 32.0/9.8 36.5/11.1 37.5/11.4 40.5/12.5 41.0/12.8 42.0/12.8 46.0/14.0 49.0/14.9 52.0/15.8 54.0/16.5 55.0/16.8 72/1830 3/4720 32.0/9.8 32.5/9.9 35.0/10.7 35.5/10.8 40.0/12.3 40.5/12.3 41.0/12.5 46.0/14.0 50.0/15.2 51.0/15.5 52.0/15.8 53.0/16.2 NOTES: • Values for use with 5.757140mm straight reducers. How to use this Design Guide: • For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. • It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 10 ✓ctsulic' victaulic.com 5.1 PERFORMANCE - FRICTION LOSS DATA FM Series AH2 and AH2-CC Braided Hoses Style AB1, AB2, AB3, AB4, ABS, AB7, AB7 Adj., ABB, AB1O, AB12, ABBA and ABMM WcFlex Brackets Length of Stainless Steel Flexible Hose inches/mm K-Factor Imperial/S.I. Outlet Size inches/mm/type Equivalent Length of 1"133.7mm Sch. 40 Pipe feet/meters Maximum Number of 90' Bends at 7/178mm Bend Radius 31 /790 5.6/8.1 /2 '"/15/Straight 13.8/4.2 2 '/2 715/90* Elbow 23.5/7.1 36/915 5.6/8.1 '/2"/15/Straight 16.6/5.1 2 Y2'715/90* Elbow 25.6/7.8 48/1220 5.6/8.1 '/2"/15/Straight 23.4/7.1 3 '/2'715/90* Elbow 30.7/9.3 60/1525 5.6/8.1 Y2"/15/Straight 30.2/9.2 4 '/2"/15/90° Elbow 35.9/10.9 72/1830 5.6/8.1 Y2"/15/Straight 37.0/11.3 4 '/2"/15/90° Elbow 41.1/12.5 31/790 8.0/11.5 3/4"/20/Strai ht 16.8/5.1 2 3/4"/20/90° Elbow 16.8/5.1 36/915 8.0/11.5 3/4"/20/Strai ht 20/6.0 2 3/4"/20/90° Elbow 19.7/6.0 48/1220 8.0/11.5 3/4"/20/Strai ht 27.8/8.4 3 3/4"/20/90° Elbow 26.6/8.1 60/1525 8.0/11.5 3/4"/20/Strai ht 35.7/10.9 4 3/4"/20/90° Elbow 33.6/10.2 72/1830 8.0/11.5 3/4"/20/Strai ht 43.5/13.2 4 3/4"/20/90° Elbow 40.6/12.2 31/790 11.2/16.1 3/4"/20/Strai ht 16.5/5.0 2 3/4"/20/90° Elbow 17.8/5.4 36/915 11.2/16.1 3/4"/20/Strai ht 19.5/5.9 2 3/4"/20/90° Elbow 20.7/6.3 48/1220 11.2/16.1 3/4"/20/Strai ht 26.7/8.1 3 3/4"/20/90° Elbow 27.9/8.5 60/1525 11.2/16.1 3/4"/20/Strai ht 33.9/10.3 4 3/4"/20/90° Elbow 35/10.7 72/1830 11.2/16.1 3/4"/20/Strai ht 41.3/12.5 4 3/4"/20/90° Elbow 42.2/12.8 31/790 14.0/20.2 14.0/20.2 3/4"/20/Strai ht 14.9/4.5 2 3/4"/20/90° Elbow 15.5/4.72 36/915 3/4"/20/Strai ht 19.4/5.9 2 3/4"/20/90° Elbow 19.6/5.9 48/1220 14.0/20.2 3/4"/20/Strai ht 30.3/9.2 3 3/4"/20/90° Elbow 29.5/8.9 60/1525 14.0/20.2 3/4"/20/Strai ht 33.9/10.3 4 3/4"/20/90° Elbow 34.1/10.4 72/1830 14.0/20.2 3/4"/20/Strai ht 37.5/11.4 4 3/4"/20/90° Elbow 38.6/11.7 FM NOTES: • The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • EXAMPLE: A 48-inch hose installed with two 30' bends and two 90' bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 19 ✓ctsulic' victaulic.com 5.2 PERFORMANCE - FRICTION LOSS DATA FM Series AH2 Braided Hose with 90' Low Profile Elbows Style AB5, AB11, AB12, ABBA and ABMM WcFlex Bracket Length of Stainless Steel Flexible Hose K-Factor inches/mm Imperial/S.I. Outlet Size inches/mm Equivalent Length of 1'733.7mm Sch. 40 Pipe feet/meters Maximum Number of 90' Bends at 7/178mm Bend Radius 31 /790 5.6/8.1 1/2715 13.7/4.2 2 36/915 5.6/8.1 1/2"/15 17.0/5.2 2 48/1220 5.6/8.1 1/2 715 25.0/7.6 3 60/1525 5.6/8.1 1/2715 33.0/10.1 4 72/1830 5.6/8.1 1/2 715 41.1 /12.5 4 31 /790 8.0/11.5 3/4"/20 13.6/4.14 2 36/915 8.0/11.5 3/4"/20 16.9/5.2 2 48/1220 8.0/11.5 3/4"/20 27.8/8.5 3 60/1525 8.0/11.5 3/4"/20 32.6/9.9 4 72/1830 8.0/11.5 3/4"/20 40.6/12.4 4 31 /790 11.2/16.1 3/4"/20 13.7/4.2 2 36/915 11.2/16.1 3/4"/20 17.0/5.2 2 48/1220 11.2/16.1 3/4"/20 24.9/7.6 3 60/1525 11.2/16.1 3/4"/20 32.9/10.0 4 72/1830 11.2/16.1 3/4"/20 40.9/12.5 4 31 /790 14.0/20.2 3/4"/20 13.5/4.1 16.8/5.1 2 36/915 14.0/20.2 3/4"/20 2 48/1220 14.0/20.2 3/4"/20 24.7/7.5 3 60/1525 14.0/20.2 3/4"/20 32.7/9.9 4 72/1830 14.0/20.2 3/4"/20 40.7/12.4 4 FM NOTES: • The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • EXAMPLE: A 48-inch hose installed with two 30' bends and two 90' bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 20 ✓ctsulic' 5.3 PERFORMANCE - FRICTION LOSS DATA VdS Series AH2 and AH2-CC Braided Hose Style AB1, AB2, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB11 and AB12 Brackets Length of Stainless Steel Outlet Flexible Hose Size mm/inches mm/inches 15 mm/1/2" 31 /790 AL 20 mm/3/4" 15 mm/1/2" 36/915 20 mm/3/4" 15 mm/1/2" 48/1220 20 mm/3/4" 15 mm/1/2" 60/1525 20 mm/3/4" 15 mm/1/2" 72/1830 20 m m/3/4" VDS CEILING MANUFACTURERS LIST AB1, AB2, AB7, AB10 ,AB11 AB4 AB5, AB8 1. AMF No specific approval 1. Hilti 2. Armstrong 2. Knauf 3. Chicago Metallic 3. Lafarge 4. Dipling 4. Lindner S. Durlum 5. Rigips 6. Geipel 7. Gema-Armstrong 8. Hilti 9. Knauf 10. Lafarge 11. Linder 12. Odenwald 13. Richter 14. Rigips 15. Rockfon Pagos 16. Suckow & Fischer 17. USG Donn Series AH2 and AH2-CC Braided Hose LPCB Style AB1, AB2, AB3, AB4, AB5, AB7, AB8, and AB10 Brackets Length of Equivalent Length Maximum Stainless of steel pipe Number of Steel according to 90' Bends at Flexible Outlet EN 10255 ON 25 3'776.2 mm Hose Size (33,7 x 3,25) Bend Radius mm/inches mm/inches/type meters/feet 790/31 15 mm/1/2"/Strai ht 1.8/6.0 2 20mm/3/4"/Strai ht 15 mm/1/2"/Strai ht 915/36 3.6/11.9 3 20mm/3/4"/Straight 15 mm/1/2"/Strai ht 1220/48 4.3/14.0 3 20mm/3/4"/Strai ht 15 mm/1/2"/Strai ht 1525/60 4.1 /13.6 3 20mm/3/4"/Strai ht 15 mm/1/2"/Strai ht 1830/72 5.5/18.1 3 20mm/3/4"/Strai ht Equivalent Length of Maximum Number steel pipe according to of 90' Bends at EN 10255 ON 25 3776.2 mm Bend (33,7 x 3,25) Radius meters/feet meters/feet 5.5/18.0 3 6.4/21.0 3 8.5/27.9 3 10.7/35.1 4 4 Series AH2 Braided Hose Style AB1, AB2, AB3, AB4, AB5, AB7, AB8, AB10 and AB12 Brackets Length of Flexible Equivalent Length of Hose 1"/33.7 mm Sch. 40 Pipe mm inches Straight Configuration Bend Configuration 790 0.87 2.70 31 2.9 8.9 915 1.00 2.80 36 3.3 9.2 1220 2.23 4.66 48 7.3 15.3 1525 2.90 6.5 60 9.5 21.3 1830 3.31 7.16 72 10.9 23.5 CCCF NOTE • Friction loss data is in accordance with GB5135.16 tested at a flow rate of 114 liters per minute (30 gallons per minute). 10.85 5839 Rev AG Updated 07/2019 0 2019 Victaulic Company. All rights reserved. victaulic.com 21 ✓ctauliic' victaulic.com 6.0 NOTIFICATIONS A WARNING ®o • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Always verify that the piping system has been completely depressurized and drained immediately prior to installa- tion, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. • It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. • The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 22 ✓ctauliic' victaulic.com 7.0 REFERENCE MATERIALS — CHARACTERISTICS WcFlex Maximum Load Values Series AH2 Hose with 24" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m Ib N Ib/linearft N/linearm 31 /790 2.6 5.2 23 2.6 on 38 36/915 0 9 5.5 25 2.8 40 48/1220 2 6.3 28 3.1 46 1 60/1525 5 7.0 31 3.5 51 1 72/1830 8 7.7 34 3.9 57 1 Series AH2 Hose with 48" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m Ib N Ib/linearft N/linearm 31 /790 2.6 6.1 27 1.5 22 0.8 36/915 9 6.4 29 1.6 23 48/1220 2 7.2 32 1.8 26 1 60/1525 5 7.9 35 2.0 29 1 72/1830 8 8.7 39 2.2 32 1 Total Load is defined as the sum of the weights of the following: • water -filled flexible sprinkler hose with threaded end fittings, including a typical fire sprinkler • bracket assembly (any applicable Victaulic bracket model of the relevant associated size) ASTM C 635: Suspension System Load -Carrying Capabilities (excerpted) Suspension System Actual Length ft/m Min. Allowable Uniform Load Ib/linearft N/linearm Direct Hung Light 5.0 75.7 Intermediate 12.0 181.0 Heavy 16.0 241.7 SUMMARY: All direct -hung suspension system duty classifications per ASTM C 635 are able to withstand the maximum water -filled weight of the WcFlex sprinkler hose and bracket. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 23 ✓ctauliic' victaulic.corn 7.0 REFERENCE MATERIALS — CHARACTERISTICS (CONTINUED) Flexible Hose In -Plane Bend Characteristics One Bend I \ I I \ I I Minimum bend radius I I I 90. I _—�— Two Bends fi OR Minimum I bend radius Minimum bend radius Minimum bend radius Three Bends OR Minimum bend radius NOTE For out -of -plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. I-VicFlex-AB1-AB2-AB10 I-VicFlex-AB3 I-VicFlex-AB4 I-VicFlex-AB7 I-VicFlex-AB8 I-VicFlex-AB12 I-VicFlex-ABBA -VicFlex-ABMM Minimum bend radius ,imum d radius User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products for a particular end -use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations. instructions. Nothing in this or any other document, nor any verbal recommendation, Installation advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to -VICFLEX-AB1-AB2-AB10, I-VICFLEX-AB4, or waive any provision of Victaulic Company's standard conditions of sale, installation I-VICFLEX-AB7, or I-VICFLEX-AB8 for the product you are installing. Handbooks are guide, or this disclaimer. included with each shipment of Victaulic products for complete installation and assembly Intellectual Property Rights data, and are available in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such Trademarks material, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms "Patented" or "Patent Pending" refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. virtmrrlir rnm 24 ✓ctsulic' 0000000. cosco ' • • •• • •' Fire Protection SECTION 2. SPRINKLER HEADS Page 1 of 5 VK3021 QUICK RESPONSE 4 I W PENDENT SPRINKLER (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION The Viking VK3021 Quick Response Pendent Sprinkler is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Chart. 2. LISTINGS AND APPROVALS C &US UL Listed: Category VNIV F M FM Approved: Classes 2017, 2015, 2043 APPROVED Refer to the Approval Chart and Design Criteria for requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to: 175 psi (12 bar) water working pressure. Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" NPT (15 mm BSPT) Nominal K-factor: 5.6 U.S. (80.6 metric*) Glass -bulb fluid temperature rated to -65 °F (-55 °C) Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass CW602N, UNS-C84400 or QM Brass Deflector: Stainless Steel UNS S30400 Pip Cap Shell - Stainless Steel UNS-S44400 Pip Cap Disc - Stainless Steel UNS-S30100 Belleville Spring - Nickel Alloy Pip Cap Seal - Polytetrafluoroethylene (PTFE) Compression Screw: Brass CW612N, CW508L, UNS-C36000 or UNS-C26000 Shipping Cap: Polyethylene Bulb: Glass, nominal 3 mm diameter Finishes and Temperatures: WARNING: Cancer and Reproductive Harm- www.P65Warnings.ca.gov Finish Brass Chrome White Polyester Black Polyester ENT -- Suffix A F M-/W M413 JN Temperature 135 °F 57 °C 155 °F 68 °C 175 °F 79 °C 200 °F 93 °C 286 °F 141 °C Open Suffix A B D E G Z Ordering Information: (Refer to Table 1 and the current Viking List Price Book.) 4. INSTALLATION Refer to appropriate NFPA, FM Global, and/or any other applicable installation standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler reaches its operating temperature, the heat -sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK3021 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_020616 19.06.10 Rev 19.5 Replaces Form No. F_020616 Rev 19.1 (Revised FM Design Criteria; removed NP-4 Escutcheon; added new wnrech PN 22940) Page 2 of 5 VK3021 QUICK RESPONSE 4 I IQ PENDENT SPRINKLER (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TABLE 1: ORDERING INFORMATION Instructions: Using the sprinkler base part number, .. the suffix for the desired.. Size the suffix for the desired Temperature Rating. 1: Finishes 2: Temperature Ratings Sprinkler Description Suffix, Nominal Rating Bulb Color Max. Ambient Ceiling Suffix Base Part NPT BSPT No. Inch mm I Temperature 19917 1/2 -- Brass A 135 °F (57 °C) Orange 100 °F (38 °C) A 19929 -- 15 Chrome F 155 °F (68 °C) Red 100 °F (38 °C) B White Polyester 4,6 M-/W 175 °F (79 °C) Yellow 150 °F (65 °C) D Black Polyester 4.6 M-/B 200 °F (93 °C) Green 150 °F (65 °C) E ENT 4,5,6 JN 286 °F (141 °C) Blue 225 °F (107 °C) G Open -- -- Z Example: 19917MB/W = VK3021 with White Polyester Finish and 155 °F (68 °C) Nominal temperature rating. This sprinkler is to be installed into an area with a maximum ambient temperature of 100 °F (38 °C) meaning if the area will experience temperatures above the maximum ambient rating, you shall use a higher temperature -rated sprinkler. Accessories Sprinkler Wrenches (see Figure 1): A. Installer Wrench: Part No. 22055 (available since 2017). B. Cabinet Wrench: Part No. 20901 M/B (available since 2017). C. Recessed Socket Wrench: Part No. 20951 M/B2 (available since 2017). D. Straight Wrench: Part No. 22940MB Sprinkler Cabinet: A. Up to 6 sprinklers: Part number 01724A (available since 1971). B. 6-12 Sprinklers: Part number 01725A (available since 1971). Footnotes 1 Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. z. Requires a 1/2" ratchet which is not available from Viking. 3. Based on NFPA 13, NFPA 13R, and NFPA 131). Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 4. UL Listed as corrosion resistant. 5. FM Approved as a corrosion proofing coating for installation in corrosive environments. e. The corrosion resistant and corrosion proofing coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. A B C d( Figure 1: Sprinkler Wrenches 7/16" (11 mm) Nominal Pipe Engagement 1/2" I 1/2" NPT 15 mm BSPT 1-15/16" (49 mm) Figure 2: Sprinkler Dimensions Form No. F_020616 19.06.10 Rev 19.5 Page 3 of 5 C N4 I [a VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com APPROVAL CHART Finish(es)� Viking Quick Response Pendent Sprinkler Temperature(s)lA1 X KEY VK3021 K5.6 (80.6 metric) Escutcheon(s),Ifapplicable Maximum 175 PSI (12 Bar) WWP Thread Size Listings and Approvalsz Sprinkler Base Part Number' NPT BSPT UL FM Inch mm 19917 112 -- Al, B2X, B3Y Al, B2X, 133Y 19929 -- 15 Al, B2X, 133Y Al, B2X1 B3Y Approved Temperature Rating Code: A = 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141 °C) B = 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) Approved Finish Code: 1 = Brass, Chrome, White Polyester 3,4, Black Polyester 3,4, and ENT4,5 2 = Brass, Chrome, White Polyester 3.4, and Black Polyester 3.4 3 = ENT4.5 Approved Escutcheon Code: X = Installed with Viking Recessed Escutcheons Models NP-1, NP-2, and NP-3, or Viking Standard Surface Mounted Escutcheons Y = Installed with Viking Model NP-1 Recessed Escutcheon OR Standard Surface Mounted Escutcheons Footnotes I Base Part number is shown. For complete part number, refer to Viking's current price schedule. 2 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 3 Other colors are available upon request with the same Listings and Approvals as the standard colors. 4 cULus Listed as corrosion resistant. 5 FM Approved as corrosion proofing for corrosive environments. DESIGN CRITERIA - UL cULus Listing Requirements: The Viking VK3021 Quick Response Pendent Sprinkler is cLILus Listed as indicated in Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray Pendent sprinklers shall be followed. IMPORTANT: Always refer to Form No. F 091699 - Care and Handling of Sprinklers. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking Technical Data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. DESIGN CRITERIA - FM FM Approval Requirements: The Viking VK3021 Quick Response Pendent Sprinkler is FM Approved as quick response Non -Storage Pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM Installation guidelines may differ from UL and/or NFPA criteria. IMPORTANT: Always refer to Form No. F 091699 - Care and Handling of Sprinklers. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking Technical Data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_020616 19.06.10 Rev 19.5 Page 4 of 5 C VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6; The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. Install the escutcheon inner ring onto the sprinkler threads. f 2. Carefully slide the wrench" sideways 3. Install the sprinkler and escutcheon around the protective cap then push assembly into the pipe fitting. Be sure upwards to engage with the sprinkler the escutcheon outer ring contacts wrench flats. the surface of the finished ceiling. Figure 3: Recessed Installation (with Recessed Socket Wrench) **A 1/2" ratchet is required (not available from Viking). 1. Install the escutcheon inner ring 2. Carefully slide the wrench sideways onto the sprinkler threads. around the protective cap then push upwards to engage with the sprinkler wrench flats. -- - t t 3. Install the sprinkler and escutcheon assembly into the pipe fitting. Be sure the escutcheon outer ring contacts the surface of the finished ceiling. A Figure 4: Recessed Installation (with standard Installer's Wrench) Form No. F_020616 19.06.10 Rev 19.5 Page 5 of 5 VK3021 QUICK RESPONSE 4 I W PENDENT SPRINKLER (K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. Install the escutcheon onto the sprinkler threads. r' Allow Al�i`� Model NP-1 Recessed Escutcheon i Max. 1-7/16" (37 mm) 2. Carefully slide the wrench** sideways around the protective cap then push upwards to engage with the sprinkler wrench flats. LA Figure 5: Installation (with Straight Wrench) 2-1/8" (54 mm) Ceiling opening si. Minimum: 2-5/16" (5f Maximum: 2-1/2" (64 Ceiling opening size: Minimum: 2-5/16" (59 mm) Maximum: 2-1/2" (64 mm) Min. 13/16" (21 mm) 3. Install the sprinkler and escutcheon assembly into the pipe fitting. Be sure the escutcheon contacts the surface of the finished ceiling. zS 2-1/8" (54 mm) Max.1-3/4" Aw (44 mm) �Ale— 16" rim) Standard Surface -Mounted Escutcheon Figure 6: Installation Dimensions with Viking Escutcheons Model NP-2 or NP-3 Thread -On Recessed Escutcheon (NP-3 Outer ring has a larger diameter) Min. 15/16" (24Imm) W Form No. F_020616 19.06.10 Rev 19.5 Replaces Form No. F_020616 Rev 19.1 (Revised FM Design Criteria; removed NP-4 Escutcheon; added new wnrech PN 22940) 0000000. COSCO ' • • •• • •' Fire Protection SECTION 3. HANGERS Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) B3205L - Threaded Rod (right & left hand threads) Size Range: 3/8"-16 thru 3"-4 rod Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F (399'Q Finish: Plain or Electro-GaIvan ized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish (9) TOLCD- TL Specify Length 'L' TL �\ A Thread Size Standard Design Load Thread Size Thread Length TL 650°F (343°C) 7501(399°C) Part No. A in. (MM) Lbs. (M) Lbs. (M) B3205-3/8 x 'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x T' 1/2'-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x 'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x 'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 x 'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) For larger sizes consult full line pipe hanger catalog ATR - All Threaded Rod -120" (3.05m) Lengths (TOLCO Fig. 100) Fig. 99 - All Threaded Rod Cut To Length Size Range: 3/8"-16 thru 11/2"-6 rod in 120" lengths or cut to length Material: Steel Maximum Temperature: 750°F (399'Q Finish: Plain or Electro-GaIvan ized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Part No. - Size x Length ATR Fig. 99 Threads Per Inch Recommended Load Lbs. (M) Approx. Wt./100 Ft. Lbs. (kg) ATR 1/4' x 120 99-1/4" x length 20 240 (1.07) 12 (5.44) ATR 3/8" x 120 99-3/8" x length 16 730 (3.24) 29 (13.15) ATR 1/2" x 120 99-1/2" x length 13 1350 (6.00) 53 (24.04) ATR 5/8" x 120 99-5/8" x length 11 2160 (9.60) 89 (40.37) ATR 3/4" x 120 99-3/4" x length 10 3230 (14.37) 123 (55.79) ATR 7/8" x 120 99-7/8' x length 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. by E:t•N Line Revised412812014 94 Fire Protection Solutions by Fig. 2 — Adjustable Band Hanger Size Range — Size 21/2" thru 6" pipe. Material — Carbon Steel, Pre -Galvanized Function — Recommended for the suspension of non -insulated pipe or insulated pipe with Fig. 220 shield. Fig. 2NFPA accommodates the reduced rod schedule of the National Fire Protection Association Pamphlet 13. Approvals — Factory Mutual Engineering approved. Underwriters Laboratories Listed. Conforms to Federal Specification WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Finish — Pre -Galvanized Note — Available in Stainless Steel materials. Order By — Figure number, pipe size and material Dimensions • Weights Pipe Max. Rec. Approx. Size Rod Size A B C Load Lbs. wt./100 21/2 1/2" 53/4 41/4 15/8 600 41 3 1/2' 6 41/8 11/4 600 45 31/2 1/2' 73/8 51/4 21/8 600 52 4 5/8` 73/8 5 15/8 1000 59 5 5/8*" 9 61/8 21/4 1250 97 6 3/4— 93/8 61/2 17/8 1250 139 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com