FIR2021-0088+Fire_Sprinkler_Plan+8.4.2021_1.49.06_PM+2339343Swedish Edmonds 3000# NORMAL WEIGHT CONCRETE HILTI HDIp-TZ DROP IN ANCHOR (E) BRANCHLINE❑ 1"ARM OVER LENGTH VARIES DER N FPA 13 - 9.2.3.5.2. WHERE rH E MAXIMUM STATIC OR -LOWING PRESSURE EXCEEDS 100 PSI, THE CUMULATIVE 1ORIZONTAL LENGTH OFAN JNSUPPORTED ARM -OVER TO A SPRINKLER OR SPRINKLER DROP SHALL NOT EXCEED 12" FOR STEEL PIPE. 1" DROP LENGTH VARIES 48" VICFLEX ASSEMBLY ACT / GYP BRACKET CEILING TILES CONCEALED PENDENT SPRINKLER VICFLEX DETAIL I LU I I I No changes to the ceiling in this room , I I No changes to the ceiling in this room GWB @ 9-0 No changes to the ceiling in this room Soiled 110 I I ❑ %'R ❑ o r'_ GWB @ 9-0 � OR Room #5 , 4 GWB @ 9-0 b OR Room #1 ❑ Existing Soffit @ 6-6 , I Existing Soffit @ 5 ❑ �❑ No changes to the ceiling in this room ❑ I No changes to the ceiling in this room , Rl R ❑ GWB @9-0----- OR Room #6 I Clean Core 109 , GWB @ 9-0 ACT @ 8'-0 OR Room #2 o I ❑ I No changes to the ceiling in this room � No changes to the ceiling in this room ❑ I ❑ ❑ IF]I 4 , GWB @ 9-0 GWB @ 9-0 OR Room #3 OR Room #7 t�� r Existing Soffit @ 6-6 Existing Soffit @ V-6 I io No changes to the ceiling in this room 2'-9 8'-0 L 4'-9 � I I No changes to the ceiling in this room I I I GWB @ 9-0 OR Room #8 OR Room #4 I Existing heads to be turned up for coverage during construction. New pendant sprinklers on flex drops to be set in new act from I existing outlets. I I I �— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Approved by Fire 08/18/2021 AFM fC-F�ttarer Inspections required prior to cover and after for final FLOOR PLAN SCALE: NTS V a, 7 E E SurLseFiiiy Center Scope of Work: 1. Relocate 10 pendant sprinklers to conform to the tenant improvement and provide required coverage per N FPA 13, 2916 and the City of Edmonds. 2. Max head spacing 225 sq ft for Light Hazard -Hospital 3. Unobstructed non-combustible construction- I B General Notes 1. All design and installation is in accordance with N FPA 13 2916 and the City of Edmonds.. 2. All material and equipment to be new and U L listed or FM approved. 3. New Black Schedule 40 Steel Pipe. 4. 1" Threaded pipe and fittings. 5. Piping dimensions are cut length. 6. Hangers and method of hanging to be in accordance with N FPA 13 2916. i. Joining of pipe and fittings, threaded and welded shall be in accordance with NFPA13,016. 8. Owner to provide adequate heat to prevent pipe from freezing in areas protected by wet pipe sprinkler system. 9. Structural adequacy of the building to support the sprinkler piping is the responsibility of the owner and/or structural representative. 213th PI SW 213th PI SW �A Different Mix, Bartending and Service... y 0 SEAWE Edmonds - 215th St SW 215th St SW 215th St Syy Aldercrest Health v & Rehab Center ►� 1ak� Swedish Cardiac Rehabilitation - Edmonds O 0 Swedish 21 fith St sw It Edmonds Campus Sherman Optical 0 Optician 19, rn D 11 At 4Z1 cui AMIN, !D QSeattle Skin & Laser QPuget Sound Dermatology W n v Q Cogir of Edmonds aD Assisted Living and... 216th St sw Swedish Urgent Care - Edmonds 19 Q Q Edmonds Center For Outpatient Swedish Rac Center at Ed FIR2021-0088 OVERHEAD PIPING PLAN I SCALE: 1/B" = 1'-0 SITE PLAN = VICINITY MAP �I SCALE: NTS I SCALE: NTS 21 O 4 B SCALE - 1/B" = 1'-13"