Loading...
powerpact-spec-sheet7.5 kW INCLUDES: • True Power" Electrical Technology • Digital LED Controller • Automatic Transfer Switch with Built -In Priority Load Center • Rugged Galvanneal Steel Rust Resistant Sound Attenuated Enclosure • External Main Circuit Breaker and Control Panel Access • UL 2200 Listed • Rated for winds up to 180 MPH • Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 3 Year Limited Warranty • Listed and Labeled by the Southwest Research Institute allowing installation as close as 18" (457 mm) to a structure.* *Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. https:llassets.swri.org//ibraryIDirectotyOfLiStedProducts/ Constructionlndustry/973_Doc _204_13204-01-01_Rev8.pdf FEATURES GENERAL PowerPactTM Residential Standby Generator -ooled Gas Engine Standby Power Rating Model G006998-1 (Steel - Bisque) - 7.5 kW 60 Hz (Generator with 50 Amp, 8-circuit transfer switch) C �L us LISTED GENERAC O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of O POWERPACT'": Offers an extreme value for those who desire automatic backup GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't power at the most affordable price. stop there. Total commitment to component testing, reliability testing, O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer environmental testing, destruction and life testing, plus testing to applicable network provides parts and service know-how for the entire unit, from the engine CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC to the smallest electronic component. POWER SYSTEMS with the confidence that these systems will provide superior performance. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are J PROTOTYPE TESTED J NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. A"6144 o ISO 9001: 2008 GENERAC' PowerPactTM System - 7.5 kW Engine features and benefits • Generac (OHV) design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • Cast iron cylinder walls Rigid construction and added durability provide long engine life. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field • Skewed stator • Displaced phase excitation • Automatic voltage regulation • UL 2200 listed Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. Produces a smooth output waveform for compatibility with electronic equipment. Maximizes motor starting capability. Regulates the output voltage to ±5% prevents damaging voltage spikes. For your safety. Transfer Switch • Fully automatic Transfers your vital electrical loads to the energized source of power • Remote mounting Mounts near your existing distribution panel for simple, low cost installation. • Flush mountable Can be installed between studs like a standard electrical panel. • UL listed For your safety. Digital Controls • Multiple LED annunciation Provides specific system information without having to open the generator enclosure. • Auto/Off/Manual buttons Select the operating mode. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Utility interrupt delay Prevents nuisance start-ups of the engine, setpoint approximately 5 seconds. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 6 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Cold Smart Start If the ambient temperature is cold, allows the engine to warm up before load is applied • Seven day exerciser Operates engine to prevent oil seal drying and damage between power outages. (Adjustable to bi-weekly or monthly through the Mobile LinkI system - sold separately) • Smart battery charger Maintains battery charge level to ensure starting. • Main line circuit breaker Protects generator from overload. • Multiple protection features Prevents additional damage from occurring within the generator if a fault condition arises. Unit • UL weather protective enclosure Sound attenuated enclosure ensures quiet operation and protection against mother nature. Three panels are remov- able for easy service and maintenance access. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. Installation System 0 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe GENERAC° PowerPactTM System - 7.5 kW Generator specifications Model G006998-1 Rated Maximum Continuous Power Capacity (LP) 7,500 Watts' Rated Maximum Continuous Power Capacity (NG) 6,000 Watts" Rated Voltage 240 Rated Maximum Continuous Load Current — 240 Volts (LP/NG) 31.25 / 25 Main Line Circuit Breaker 35 Amp Phase 1 Number of Rotor Poles 2 Rated AC Frequency 60H7 Power Factor 1.0 Battery Requirement (not included) Group U1, 12 Volts and 300 CCA Minimum Unit Weight (lb/kg) 280 (127.3) Dimensions (L x W x H) in/mm 36 x 27 x 25/915 x 676 x 640 Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load"' 69 Engine Type of Engine GENERAC OHV Number of Cylinders 1 Displacement 420 cc Cylinder Block Aluminum w/ Cast Iron Sleeve Valve Arrangement Overhead Valve Ignition System Solid-state w/ Magneto Governor System Mechanical , Starter 12 VDC Oil Capacity Including Filter Approx.1.2 gt/1.1 L , Operating rpm 3600 Fuel Consumption Natural Gas ft3/hr (m3/hr) 1/2 Load 73 (2.07) Full Load 117 (3.31) Liquid Propane ft3/hr (gal/hr) [I/hr] 1/2 Load 31.6 (0.87) [3.29] Full Load Al kL 51.6 (1.42) [5.37] Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 5-7" water column (6-13 mm mercury) for natural gas,10-12" water column (19-22 mm mercury) for LP gas. For BTU content, multiply ft3/hr x 2500 (LP) or ft3/hr x 1000 (NG). For Megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG) Controls LED Indicators Simple user interface for ease of operation. Mode Switch: Auto Automatic Start on Utility failure. 7 day exerciser. , Off Stops unit. Power is removed. Control and charger still operate. Manual/Test (start) Start with starter control, unit stays on. If utility fails, transfer to load takes place." Engine Start Sequence Cyclic cranking: Engine cranks a maximum of five times at factory set intervals and durations Engine Warm-up 6 sec (30 sec with Cold Smart Start) Engine Cool -Down 1 min Starter Lock -out Starter cannot re-engage until 5 sec after engine has stopped. 2.5 Amp Smart Battery Charger Standard Automatic Voltage Regulator Standard _ Automatic Low Oil Level Shutdown Standard Overspeed Shutdown Standard _ Underspeed Shutdown Standard High Temperature Shutdown Standard _ Overcrank Protection Standard Safety Fused Standard Wiring Error Detection Standard Battery Problem Warning Standard Charger Problem Warning Standard RPM Sensor Loss Shutdown Standard ' Maintenance Indicators (Indicate Break-in and Regular Maintenance is due) Standard `"Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). " Maximum wattage and current are subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 °F) above 16 °C (60 °F). GENERAG' PowerPactTM System - 7.5 kW transfer switch Transfer Switch Features • Electrically operated, mechanically -held contacts for fast, positive connections. • Rated for all classes of load, 100% equipment rated, both inductive and resistive. • 2-pole, 240 VAC contactors. • 60 millisecond transfer time. • NEMA 1 (indoor rated) enclosure is standard. • Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton, and Square D for the most flexible and cost effective install. • Flush mountable. Dimensions Mechanical Dimensions Height Width H1 H2 W1 W2 Depth in 11.5 14.8 11 14.4 4 mm 292 375 280 366 100 Wire Ranges Neutral Lug Ground Lug 2/0 - #14 2/0 - #14 Model G006998-1 No. of Poles 2 Current Rating (Amps) 50 Voltage 120/24010 Utility Voltage Monitor (Fixed)* —Pick-up 80% Dropout 65% Return to Utility* approx.15 sec Exerciser weekly for 12 minutes* Standard ILL Listed Standard Total of Pre -wired Circuits 8 No. 15A120V 5 No. 20 A 120 V 1 No. 20 A 240 V - No. 30 A 240 V 1 No. 40 A 240 V - No. 50 A 240 V - Tandem Breaker Capability __MMIL 8 spaces Circuit Breaker Protected Available RMS Symmetrical 10,000 Fault Current @ 240 Vols Weight (Lb/Kg) I'M 20/9.1 Installation whips included No *Function of Controller GENERAC PowerPactTM System - 7.5 kW available accessories Model # Product Description The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the LP tank's fuel level is an important step in G007005-0 Wi-Fi LP Fuel Level Monitor making sure your generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify when your LP tank is in need of a refill. G006808-1 Cold Weather Kit The cold weather kit is required for PowerPact units installed in regions where the temperature regularly falls below 32 °F (0 °C). Generac's scheduled maintenance kits provide all the hardware necessary to G006806-0 Scheduled Maintenance Kit perform complete routine maintenance on a Generac automatic standby generator. If the generator enclosure is scratched or damaged, it is important to touch-up the G005703-0 Paint Kit paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006664-0 Local Wireless Remote Completely wireless and battery powered, Generac's wireless remote monitor provides you with instant status information without ever leaving the house. 6422 [25.3f dimensions & PCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. 679,6 [26.8f 636 [25.01 LEFT SIDE VIEW GENERAL" Model UPC G006998-1 696471074390 [35.21 FRONT SIDE VIEW Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2018 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. OL6848-E 04/16/18