APPROVED BLD PLN RESUB 1 - BLD2021-1450+Architectural_Plan+12.8.2021_10.16.49_PM+2561867CODE NOTES All work shall conform to The Edmonds City Code and Community Development Code is current through Ordinance 4232, passed August 24, 2021. ALL WORK SHALL CONFORM TO BUILDING CODES ADOPTED BY THE CITY OF EDMONDS AS OF 2/1/2021 AS AMENDED BY THE STATE OF WASHINGTON BUILDING CODE COUNCIL. 2018 INTERNATIONAL RESIDENTIAL CODE (IRC), 2018 INTERNATIONAL MECHANCIAL CODE (IMC), 2018 INTERNATIONAL ENEGY CODE. RESIDENTIAL II WITH WASHINGTON STATE AMENDMENTS (WESC), 2018 INTERNATIONAL FIRE CODE (IFC), 2018 INTERNATIONAL ELECTRICAL CODE (IEC) 2018 INTERNATIONAL FUEL GAS CODE (IFGC) THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND INSPECTIONS TO COMPLETE THE WORK. PLUMBING AND ELECTRICAL WORK IS DESIGN -BUILD. GENERAL NOTES THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO INITIATING THE WORK. CONTRACTOR TO NOTIFY ARCHITECT IMMEDIATELY IF HE HAS ANY QUESTIONS. DO NOT SCALE ANY DIMENSIONS FROM THE DRAWINGS. VERIFY ALL DIMENSIONS, DATUMS AND LEVELS PRIOR TO CONSTRUCTION. ALL DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. NOTIFY ARCHITECT DESIGN IMMEDIATELY IF CONFLICTS EXIST. VERIFY ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THE CONTRACT AND BY OTHERS. PROVIDE ALL BLOCK -OUTS, BLOCKING, BACKING AND JACKS REQUIRED FOR INSTALLATION. VERIFY LOCATION OF ALL EXISTING UTILITIES; CAP, MARK AND PROTECT AS NECESSARY TO COMPLETE THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES REQUIRED TO PERFORM THEIR WORK. ATTIC VENTILATION: MINIMUM NET AREA SHALL BE NOT LESS THAN 1 S.F. PER 150 S.F. OF ATTIC AREA OR 1 S.F. PER 300 S.F. OF ATTIC AREA IF 1/2 IS IN THE SOFFIT AND 1/2 IS AT LEAST 3' ABOVE THE PLATE LINE FUEL BURNING APPLIANCES SHALL BE ASSURED A SUFFICIENT SUPPLY OF COMBUSTION AIR PER SMC. ALL WARM -AIR FURNACES SHALL BE LISTED AND LABELED BY AN APPROVED AGENCY AND INSTALLED AND VENTED ACCORDING TO SPECIFICATIONS. PROVIDE A MINIMUM CLEAR WORKING SPACE OF 3" MINIMUM ALONG SIDES, BACK AND TOP OF FURNACE WITH 12" MINIMUM CLEARANCE TOTAL SIDE TO SIDE. THE BUILDING SHALL COMPLY WITH WASHINGTON STATE ENERGY CODE. NIGHT SETBACK THERMOSTAT IS REQUIRED. SEAL AND CAULK ALL CRACKS TO PREVENT AIR INFILTRATION. HOT WATER TANK SHALL HAVE TYPE IV PRESSURE RELIEF VALVE TO COMPLY WITH ASHRAE 90A-80 LISTING AND APPROVAL. INSULATE TANK WITH R-19 AND FIT HOT WATER LINES WITH SNAP ON TYPE INSULATION PER WASHINGTON STATE ENERGY CODE. IN UNHEATED AREAS, ELECTRIC FURNACES AND WATER HEATERS SHALL BE SET ON AN INCOMPRESSIBLE INSULATED SURFACE OF R-10 MINIMUM. HOT WATER TANKS LOCATED ABOVE HOT WATER FIXTURE OUTLETS REQUIRE VACUUM RELIEF VALVES. SMC. DUCT SYSTEMS SHALL BE OF METAL PER U.M.C. TABLE 10-A, 10-B AND 10-C OR FACTORY MADE DUCTS COMPLYING WITH U.M.C. STANDARD 10-1. ALL JOINTS AND SEAMS SHALL BE SUBSTANTIALLY AIRTIGHT. DUCTS IN UNHEATED SPACES SHALL HAVE 2" INSULATION MINIMUM OR 1/2" DUCT LINER. ALL EXPOSED EXTERIOR METAL SHALL BE GALVANIZED. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. PRESSURE TREATED WOOD SHALL BE USED FOR WOOD MEMBERS WHICH FORM THE STRUCTURAL SUPPORT OF BALCONIES, PORCHES, ETC. WHEN SUCH MEMBERS ARE EXPOSED TO THE WEATHER PER SBC SLOPE ALL DECKS, WALKS, DRIVEWAYS, AND PATIOS AWAY FROM BUILDING 1/4"/FT MINIMUM. EXTERIOR DOORS SHALL BE PROVIDED WITH CONTINUOUS METAL WEATHER-STRIP, METAL THRESHOLD, CYLINDER LOCK ACCESSED DEAD BOLT WITH THUMB TURN AND 1"THROW AND 1/4" INTO CATCH PLATE. PROVIDE FIRE BLOCKING, DRAFT STOPS AND FIRE STOPS PER SRC ROOF DRAINS AND OVERFLOW DRAINS SHALL COMPLY WITH THE IRC & IMC. ROOF AND FOOTING DRAINS ARE TO BE TIGHT LINED SEPARATELY TO APPROVED DISCHARGE. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY ARCHITECT AND THE STRUCTURAL ENGINEER. DO NOT SIGNIFICANTLY VARY OR MODIFY THE WORK SHOWN, EXCEPT WITH WRITTEN AUTHORIZATION FROM ARCHITECT REPORT ERRORS AND OMISSIONS TO ARCHITECT IMMEDIATELY. THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF ARCHITECT AND MAY BE REPRODUCED ONLY WITH THE WRITTEN PERMISSION OF ARCHITECT AUTHORIZED REPRODUCTIONS MUST BEAR THE NAME OF ARCHITECT. RECEPTACLE OUTLETS: PER 2018 INTERNATIONAL ELECTRICAL CODE (IEC) 1. OUTLETS SHALL BE INSTALLED SO THAT NO POINT ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6 FEET FROM AN OUTLET INCLUDING ANY WALL SPACE 2 FEET OR MORE IN WIDTH. NOTE: WALL SPACE INCLUDES FIXED PANELS, FIXED ROOM DIVIDES SUCH AS RAILINGS AND FREE STANDING BAR -TYPE COUNTERS. 2. WALLS ABOVE COUNTER SPACE ARE REQUIRED TO HAVE AN OUTLET WHEN THE COUNTER IS 12 INCHES OR GREATER IN WIDTH. THEY SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL IS MORE THAN 24 INCHES FROM A RECEPTACLE. 3. AT LEAST ONE WALL RECEPTACLE OUTLET SHALL BE INSTALLED IN BATHROOMS WITHIN 36 INCHES OF THE OUTSIDE EDGE OF EACH LAVATORY BASIN. 4. HALLWAYS OF 10 FEET OR MORE IN LENGTH SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET. MATERIALS &FINISHES LISTED ON INTERIOR &EXTERIOR ELEVATIONS ARE FOR GENERAL INFORMATION &CONVENIENCE OF CONTRACTOR, IN ADDITION TO MATERIALS &FINISHES INDICATED OR SPECIFIED ELSEWHERE IN THE DRAWINGS. N.I.C. EQUIPMENT IS FURNISHED &INSTALLED BY OTHERS. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING INSTALLATION & PERFORMING WORK AS REQUIRED BY DETAILS OR SPECIFICATIONS FOR EQUIPMENT INSTALLATION. FURNISHED BY OTHERS INSTALLED BY CONTRACTOR (F.O.I.C.) EQUIPMENT IS FURNISHED BY OTHERS &INSTALLED AS A PART OF THIS WORK. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK AS REQUIRED FOR INSTALLATION. CONTRACTOR SHALL SEAL AROUND ALL PENETRATIONS FOR FIRE RATED WALLS, INCLUDING BUT NOT LIMITED TO, PIPING, DUCT AND CONDUIT, ETC. WITH FIRE -STOPPING PER CODE REQUIREMENTS. CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE VAPOR BARRIER MEMBRANE AT FLOOR SLAB AND ROOF, WEATHER BARRIER AT WALLS, BACKER ROD, SEALANT, &OTHER APPROVED MEANS SHALL BE APPLIED CONTINUOUSLY AROUND ALL EXTERIOR DOOR &WINDOW OPENINGS & OTHER AREAS OF POTENTIAL AIR INFILTRATION, INCLUDING STRUCTURAL, MECHANICAL, &ELECTRICAL PENETRATIONS. THE CONTRACTOR SHALL REPAIR ANY DAMAGE TO VAPOR BARRIERS, OR REPLACE THEM PRIOR TO COVER, AS APPROVED. CAULK, SEAL OR WEATHER-STRIP ALL OPENINGS IN THE EXTERIOR WALLS, AS APPROPRIATE TO LIMIT AIR LEAKAGE. ALL GLASS DOORS SHALL BE INSULATED SAFETY GLASS. INSULATE WATER HEATERS WITH R-19 MIN. 2018 INTERNATIONAL RESIDENTIAL CODE (IRC This is a review of the codes that are relevant to this project. This review has been abridged and edited to highlight pertinent code issues. Contractor to use this review as reference only. Consult IRC for detailed understanding of the code. R302.1 The interior design temperatures used for heating and cooling load calculations shall be a maximum of 72 degrees F for heating and a minimum of 75 degrees F for cooling. R302.5.1 Opening from garage directly into a sleeping room used for sleeping shall not be permitted. Other other openings between the garage and residence shall be a solid wood door, solid or honeycomb -core steel door, not less than 1-3/8 inches thick or 20 minute fire rated doors, equipped with aself-closer. R302.6 Dwelling -garage fire separation per Table R302.6. Separation from residence and attics min. 1/2" gypsum board on garage side. Separation from all rooms above garage, not less than 5/8" type X gypsum board or equivalent. Structures supporting floor/ ceiling assemblies used for separation required by this section. Not less than 1/2-inch gypsum board. Garages located less than 3 feet from a dwelling unit on the same lot. Not less than 1/2-inch gypsum board applied to the interior side of the exterior walls that are within this area. R302.11 Fire blocking. In combustible construction, fire blocking shall be provided to cut off all concealed draft openings (both vertical and horizontal) and form an effective fire barrier between stories, and between a top story and the roof space R303.1 Natural light: All habitable rooms shall have an aggregate glazing area of not less than 8 percent of the floor area of such rooms. R303.5.1 Intake openings. Mechanical and gravity outdoor air intake openings shall be located a minimum of 10 feet from any hazardous or noxious contaminates, such as vents, chimneys, plumbing vents, streets, alleys, parking lots and loading docks, except as otherwise specified in this code. R303.5.2 Exhaust openings. Exhaust air shall not be directed onto walkways. All exhaust ducts shall terminate outside the building. Terminal elements shall have a least the equivalent net free area of the ductwork. R303.5.2.1 Exhaust ducts. Exhaust ducts shall be equipped with back -draft damper. All exhaust ducts in unconditioned spaces shall be insulated to a minimum of R-4. R303.7 Interior Stairway illumination. Interior stairway illumination shall be provided with an artificial light source to illuminate the landings and treads. Stairway illumination shall receive power from the building wiring. The light source shall be capable of illuminating treads and landings to the levels of not less than 1fnot-candle as measured at the center of treads and landings. There shall be a wall switch at each floor level to control the lighting source where there are six or more risers. R303.8 Exterior stairway illumination. Exterior stairway shall be provided with artificial light source located at the top landing of the stairway. Stairway illumination shall receive power from the building wiring. Exterior stairway providing access to a basement from the outdoor grade level shall be provided with an artificial light source located at the bottom landing of the stairway. R303.10 Required heating. Every dwelling unit shall be provided with heating capable of maintaining a minimum room temperature of 68 degrees F at a point 3 feet above the floor and 2 feet from the exterior walls in habitable rooms, baths and toilet rooms at the design temperature as specified in Table R301.2(1). The installation of portable space heaters shall not be used to to achieve compliance with this section. R307.1 Space required. Toilet, Bath and Shower Spaces. Fixtures shall be space in accordance with Figure R307.1 and per the Uniform Plumbing Code Section 402.5. Toilets shall be 15" from centerline to wall on both sides. Sinks and toilets shall have 21" clearance in front. Showers shall have a min of 24" clear in front of opening. R308.1 Glazing in hazardous locations shall be provided with a manufacturer's designation, the type of glass and the safety glazing standard with which it complies, and that is visible in the final installation. The designation shall be permanently labeled. R308.4.2 Glazing adjacent to doors. Glazing less than 60 inches above the floor within 24" of a closed door shall be considered a hazardous location. R308.4.3 Glazing in windows that meets all of the following conditions shall be considered to be a hazardous location: Windows with a single pane larger than 9 square feet, lower than 18" and higher than 36" above the floor, 4. within 36 inches horizontally of a walking surface. R308.4.7 Glazing at the bottom of a stairway landing less than 36" above the landing and withing 60" horizontal shall be considered a hazardous location. R308.6.2 Permitted glazing in hazardous locations. 2. Fully tempered glass. 3. Heat -strengthened glass, 4. Wired glass. 5. Approved rigid plastics. R309.1 Garage floor surface. Shall be of approved non-combustible. The area of the floor used for parking shall be sloped to a drain or to the main vehicle entry doorway R310.1 Emergency escape and rescue required. Basements, habitable attics and every sleeping room shall have at least one operable emergency escape and rescue opening. They shall open directly into a public way or to a yard providing an unobstructed path wit a width of not less than 63 inches to opens to a public way. See exceptions. R310.2.1 Minimum opening area. Emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet. Grade floor or below grade floor openings shall have a minimum net clear opening of 5 square feet. Net clear height shall be 24 inches minimum, net clear width shall be 20" minimum. R310.2.2 Emergency escape and rescue openings sill height shall not be more than 44 inches above the floor. R311.2 Egress door . At least one egress door shall be provided for each dwelling unit. The egress door shall be side hinged and shall provide a minimum clear width of 32 inches. R311.3 Floor landings at exterior doors. There shall be a landing or floors on each side of each exterior door. The width of each landing shall not be less than the door served and be a minimum of 36 inches. Maximum slope is'/4" per foot. R311.7.2 Stairway Headroom not less than 6'-8" R311.7.5.1. The maximum riser shall be 7 3/a" the minimum tread shall be 10" R311.7.5.3 Nosings. A nosing projecting of not less than 3/4 inch but not more than 1- 1/4" shall be provided on stairways with solid risers. R311.7.6 Landings for stairways. There shall be a floor or landing at the top and bottom of each stairway. The minimum width of in the direction of travel shall be no less than the width of the flight served. R311.7.7 Stairway walking surface. The walking surface of treads and landings or stairways shall be sloped no steeper than one unit vertical in 48 inches horizontal. ( 2 percent slope) R311.7.8 Handrails. Handrails shall be provided on at least one side of each flight of stairs with four or more risers. R311.7.8.1 Handrail height shall be not less than 34 inches and not more than 38 inches. R311.7.8.4 Handrails shall be continuous from the top riser to the bottom riser. R311.7.8.5 The diameter of the handrail shall be from 1 '/4 to 2 inches. R312.1.1 Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are more than 30 inches above the adjacent grade within 36 inches to the edge of the open side. Guards shall not less than 36 inches high. R312.1.3 Guards shall not have openings which allow passage of a sphere 4 inches in diameter. Except at the triangle formed by the tread, riser and the bottom of the rail may not allow a passage of a 6 inch diameter sphere. R312.2.1 Windows that open 6 feet above grade shall be a minimum of 24" above finish floor. Or comply with fall protection per this section. R313.1 An automatic residential fire sprinkler system shall be installed in a townhouse unit. R313.1.1 Automatic fire sprinkler systems. Where installed, the design and installation of residential fire sprinkler system shall be in accordance with Section P2904 or NFPA 13D. R314.2.2. Where alterations or additions requiring a permit occur, where a sleeping room is added or an attached dwelling unit is created each dwelling unit shall be equipped with smoke alarms as required for new dwellings. R314.3 Location of smoke alarms heat detectors and heat alarms. 1. In each sleeping room or sleep loft. 2. Outside each separate sleeping area in the immediate vicinity of the bedrooms. 3. On each story of the dwelling unit including basements and habitable attics. 4. Smoke alarms shall be installed not less than 3 feet horizontally from the door of a bathroom that contains a bathtub or shower. 315.2 For new construction, an approved carbon monoxide alarms shall be installed outside each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. R319. 1 Address numbers. Buildings shall have approved address numbers. Install address numbers in a position that is plainly legible and visible from the street fronting the property. The numbers shall be a minimum of 4 inches high, on contrasting background with a minimum stroke width of/2 inch. Whole House Exhaust Fan Per M 1507 . Per M 1501.1 Exception: exhaust to attic is permitted. � REGI57EREQ M1507.3.4.2 Whole house fans shall have a sone rating of 1.0 or less. aRCHITECT M1507.3.4.4 Outdoor air shall be distributed to each habitable space by individual f�_ i F� � " �� 1 4r � � r it inl . Wh r r it li r r fr m xh in-�-�-f= •..=-=�� outdoo a ets e e out doo a supp es a e sepa ated o e gust po is by doors, ensure air flow by installation of distribution ducts, undercutting doors, installation of grilles, transoms, or similar means. Doors shall be undercut a minimum of 1 /2 inch above the surface of the finish floor covering. Individual room outdoor air inlets shall: v z 1. Have controllable and secure openings; o 2. Be sleeved or otherwise designed so as not to compromise the thermal properties w of the wall or window in which they are place; � 3. Provide not less than 4 square inches of net free area of opening for each habitable w space. Inlets shall be screened or otherwise protected form entry by leaves or other � material. Outdoor air inlets shall be located so as not to take air from the following � areas: � 3.1 Closer than 10 feet from an appliance vent outlet, unless such vent outlet is 3 feet o above the outdoor air inlet. � 3.2 Where it will pick up objectionable odors, fumes or flammable vapors. � 3.3. A hazardous or unsanitary location N 3.4. A room or space having any fuel -burning appliances therein. 3.5 Closer than 10 feet from a vent opening of a plumbing drainage system unless the N vent opening is at least 3 feet above the air inlet. 3.6 Attic, crawl space, or garages. M1507.4 Local exhaust shall be provided in each kitchen, bathroom, water closet laundry room, indoor swimming pool, spa, and other rooms where water vapor or cooking oder is produced and have the minimum exhaust capacity of Table M1507.4 Kitchens 100 cfm intermittent or 25 cfm continuous Bathrooms -Toilet Rooms, laundry rooms, indoor swimming pools and spas: 50 cfm intermittent or 20 cfm continuous. WSEC Washington State Energy Code: Provide a minimum of 4 sq. in. fresh air intake in each habitable room, integrate into windows, or use Panasonic passive inlet vent #FVGKF325. M2005.1 Water heaters shall be installed in accordance with Chapter 5 of the Uniform Plumbing Code. Uniform Plumbing Code -Chapter 5 P507.2 In seismic design categories C,D,E and F, water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of its vertical dimensions. At the lower point a distance of not less than 4 inches shall be maintained from the controls with the strapping. P507.4 Where a water heater is located in an attic, attic -ceiling assembly, floor -ceiling assembly or floor-subfloor assembly where damage results from a leaking water heater, a watertight pan of corrosion -resistant materials shall be installed beneath the water heater with not less than 3/4 of an inch diameter drain to an approved location. P507.5 Discharge from a relief valve into a water heater pan shall be prohibited. PROJECT INFORMATION Owner /Project Location: KENSHU AOKI 19729 81 ST PL W EDMONDS WA 98026 Tax Parcel NO. 6035000-1600 LEGAL DESCRIPTION Section 19 Township 27N Range 4 Quarter NE MAPLEWOOD GROVE LOT 16 PROJECT DECRIPTON: Structural Engineer: RCR ENGINEERS, PLLC 29028 176th AVE SE, Kent, WA 98042 (206) 295 9439 APPROVED BY PLANNING Dec 15 2021 ADDITION TO MASTER BEDROOMS AND BATHROOM SHEET INDEX ARCHITECTURAL A0.1 COVER SHEET, GENERAL NOTE, CODE NOTES AND SHEET INDEX A1.1 SITE PLAN A2.1 FLOOR PLANS A3.1 EXTERIOR ELEVATOINS &LATERAL BRACING / SHEARWALL SCHEDULE ceiling shall not be considered as contributing t0 the minimum required habitable area M1501.1 Outdoor discharge. The air removed by every mechanical exhaust system A4.1 BUILDING SECTION for that room. shall be discharged to the outdoor per M1502. Exception: whole -house fans may A5.1 DETAILS discharge to a private attic. R305.1 Minimum height. Habitable space, hallways, bathrooms, toilet rooms, laundry M1502.1 Clothes dryers shall be exhausted in accordance with manufacturer's STRUCTURAL rooms and portions Of basements containing these spaces shall have a ceiling height S010 STRUCTURAL GENERAL NOTES shall not be less than 7 feet. Bathrooms, toilet rooms and laundry shall have a ceiling instructions. height of not less than 6 feet 8 inches. See exceptions for sloped ceilings and M1502.2 Dryer exhaust systems shall be independent of all other systems and covey S110 STRUCUTAL FOUDANTION AND 1ST FLOOR FRAMING PLANS bathrooms. moisture to the outdoors. ROOF FRAMING PLANS R305.1.1 Basements. Portions Of basements that do not contain habitable space Or M1502.4 Dryer exhaust ducts size and length shall conform to Table M1502.4.4.1 with S210 STRUCTURAL DETAILS hallways shall have a ceiling height of not less than 6 feet 8 inches. Exception: At 4" minimum nominal diameter. beams, girders, ducts or other obstructions, the ceiling height shall be not less than 6 M1503.3 Domestic cooking exhaust equipment shall discharge to the outdoors through feet 4 inches from the finished floor. a duct. The duct shall have a smooth interior surface, shall be air tight, shall be �-•-•-•-•-•-•-•-•-•-•-•-•-•-•-•-•-•-; e ui ed with aback -draft dam er and shall be inde endent of all other exhaust � INTERCONNECTED ; R306.1 Toilet facilities. Every dwelling unit shall be provided with a water closet, q pp p p . lavatory, and a bathtub Or shower. systems. � SMOKE ALARMS AND CO R306.2 Kitchen. Each dwelling unit shall be provided with a kitchen area and every � DETECTORS AREA ; kitchen area shall be provided with a sink. City of Edmonds APPROVED OBTAIN ELECTRICAL ALL WORK SUBJECT ;REQUIREMENT OF THIS ' Building Department PLANS MUST BE PERMIT FROM TO FIELD ;PERMIT IN ACCORDANCE APPROVED Plans ON JOB SITE STATE LABOR & INSPECTION FOR INDUSTRIES CODE COMPLIANCE ;WITH R314.2.2 R304.1 Minimum area. Habitable rooms shall have a floor area of not less than 70 square feet. Exception: Kitchens. R304.2 Minimum dimensions. Habitable rooms shall not be less than 7 feet in any horizontal dimension. Exception: Kitchens. R304.3 Height effect on room area. Portions of a room with a sloping ceiling measuring less than 5 feet or a furred ceiling less than 7 feet from the finished floor to the finished M1401.1 Heating and cooling equipment and appliance shall be installed in accordance with the manufacturer's installation instructions and the requirements of this code. M1401.2 Heating and cooling equipment and appliance shall be located to permit maintenance, servicing and replacement. M1401.3 Sizing. Heating and cooling equipment and appliances shall be sized in accordance with ACCA Manual S based on building loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies. City Of Edmonds Building Department Work ADDITION Address; 19729 81ST PL W Owner ; AKOI ; Approved Date 12/01/2021 Building Official /���/� Permit Number BLD2021-14 RESUB Dec 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT vJ �^ W W /� w � � w w O 0 =z07 Z Z J Q w W � 0 W OzU= Uw�� V A0.1 A fib ------� I I I I I I I I / ' � I I I I I I � I I G UP r= CLOSET -4„ 24'-0" ���'�� ADDITION = 357 SF GROSS 20'x17'-10" ADDITION = 337 SF NET 20'x 16'-10" ALIGN 44'- A 4,1 CRAWL SPACE ACCESS ' 18" X 24" SIDE MIN. I �`+s ,1 �i� 328 SF A 4.1 / CRAWL SPACE SHWR REQUIRED VENTING 328 SF 328/300 = 1.1 SF x 144 = 157 SI 1 7"x8" FOUNDATION 4 VENTS NET FREE AREA = 51 SI LOCATE AS SHOWN 17"x8" FOUNDATION VENT NET FREE AREA = 51 SI 4 VENTS = 204 SI PROVIDED Q1 BATH, LAUNDRY 50 CFM ON SWITCH INTERMITTENT OR 20 CFM CONTINUOUS C M1507,4 MECHANICAL EXHAUST RATES IN BATHROOMS &LAUNDRY ROOMS SHALL BE 5 CFM INTERMITTENT OR 20 CFM CONTINUOUS MINIMUM REQUIRED EXHAUST RATES FOR KITCHENS SHALL BE 100 CFM INTERMITTENT OR 25 CFM CONTINUOUS M1506,3 ALL EXHAUST OPENINGS SHALL TERMINATE NOT LESS THAN 3 FEET FROM PROPERTY LINES; 3 FEET FROM OPERABLE AND NONOPERABLE OPENINGS INTO THE BUILDING AND 10 FEET FROM MECHANICAL AIR INTAKES EXCEPT y�HERE THE OPENING IS 3 FEET ABOVE THE AIR INTAKE. OPENINGS SHALL COMPLY �ITH R303,5.2 AND R303.6 M1507.3.2 (1) CONTROLS ALL VENTILATION SYSTEMS SHALL BE READILY ACCESSIBLE BY OCCUPANT. (5.2) CONTROLS SHALL NOT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES. WINDOW SCHEDI MARK Location W1 Mstr W2 Mstr W3 Mstr. Bath W4 Mstr. Bath 1 LE SIZE Top of Notes opening QTY WIDTH HEIGHT Area Ttl Are Material Type height Sill 2'Ox4'0 3 2 4 8.oD 24.DD Vinyl Single Hung 44" max sill 7'6 4' 3'6" 2'Ox5'6 2 2 5.5 11.00 22.DD 2'Ox1'6 2 1.5 2 3.00 6.00 2'Ox3'10 2 3.83 �15.32 30.64 -TOTAL 37.32 Vinyl Single Hung 44" max sill 7'6 5'6 2' Vinyl Slider Frosted 7'6 1'6 6'0 Vinyl Single Hung T- Safety 7'6 3'10 3'8" M1507.3.4.4 EACH HABITABLE SPACE SHALL BE PROVIDED WITH OUTDOOR AIR INLETS OR OPERABLE WINDOWS WITH OPENABLE AREA OF NOT LESS THAN 4 SQ. INCHES OF NET FREE AREA OF OPENING FOR EACH 10 CFM OF OUTDOOR AIR REQUIRED BY TABLE M1507.7.3.3.(1) WINDOW NOTES: PER IRC R308.4.3 W2 SHALL BE SAFETY GLAZING PER IRC R312.21. WINDOWS WITH OPENINGS LESS THAN 24" ABOVE THE FINISH FLOOR SHALL COMPLY WITH ONE OF FOLLOWING. 1. HAS OPENING OF LESS THAN 4" 2. PROVIDE WINDOW FALL PREVENTION DEVICES THAT COMPLY WITH ASTM F2090 3. PROVIDE WINDOW OPENING CONTROL DEVICES THAT COMPLY WITH R312.2.2 NEC 210.8 GROUND -FAULT CIRCUIT-INTERUPTER (GFCI) PROTECTION SHALL BE PROVIDED FOR ALL RECEPTICLE OUTLETS INSTALLED OUTDOORS, IN GARAGES, CRA�yL SPACES, UNFINISHED BASEMENTS, BATHROOMS, KITCHEN COUNTERTOPS AND ►WITHIN 6 FEET OF THE OUTSIDE EDGE OF THE SINK IN LAUNDRY ROOMS, UTILITY ROOMS AND AT SET -BARS. NEC 210.52(C)(1) RECEPTICAL OUTLETS SHALL BE INSTALLED AT EACH COUNTERTOP AND WORK SURFACE THAT IS 12 INCHES OR �yIDER, RECEPTICAL OUTLETS SHALL BE INSTALLED SO THAT NO POINT ALONG THE VyALL LINE IS MORE THAN 24 INCHES MEASURED HORIZONTALLY FROM A RECEPTIACLE OUTLET IN THAT SPACE. VERIFY IN FIELD ALIGN INTERIOR SOUTH BALL AS NOTED ���� ���� I ��� �� DUPLEX OUTLET 240V OU TLE T EQUIPMENT OUTLET RECESSED CAN FIXTURE WALL MOUNT FIXTURE ROOF VENTING ROOF AREA = 520 SF 520 SF / 300 = 1.73 SF 144x1.73sf=250 SI VENTING REQUIRED 125 SI AT RIDGE 75 SI AT EACH EAVE VENTING PROPOSED 360 SI AT RIDGE 38.5 SI AT EACH EAVE AREA OF 2" DIA HOLE = 3.14 SI 13 75 ��"� X HOLES 7.12 S15 PERR BLOCK ADDITION = 357 SF GROSS 20x17-10 = 3.5 SI PER LF X 1 1 = 38.5 SI ADDITION = 337 SF NET 20'x 16'-10" 2018 Washington State Energy Code -Residential GAF COBRA VENT 3 HAS 18,0 SI � LF X 20 LF = 360 SI Table 046.3 (energy credits) 4. Additions less than 500 sf: 1.5 credits TABLE R406.2 FUEL NORMALIZATION CREDITS Simple Heating System Size: Washington State Maximum Heat Equipment Output 10,018 Btu /Hour 2 For an initial heating system using a heat pump 1.0 that meets federal standards for the equipment Mitsubishi - 12k BTU Cooling +Heating - M-Series Wall Mounted listed in Table C403.3.2(1)C or C403.3.2(2) Air Conditioning System - 23.1 SEER ModeI:MZ-GL12NA TABLE 406.3 $1,605.75 ENERGY CREDITS 1.3 Prescriptive compliance is based on Table R402.1.1 with the following 0.5 modifications: Vertical fenestration U = 0.28 Floor R-38 Slab on grade R-10 perimeter and under entire slab RES U B Below grade slab R-10 perimeter and under entire slab or DeC 09 2021 Compliance based on Section R402.1.4: Reduce the Total conductive UA CITY OF EDMONDS by 5%. DEVELOPMENT SERVICES DEPARTMENT REGISTEREQ ARCHITECT JRMTST pkSTA, cVE RAP`iS � WEST ELEVATION -EXISTING 3. SCALE: 1/4" = 1'-0" MAX_ RInC�F FI FVATInN 4( nF_44� 3 EAST ELEVATION I 6, a I 0 C'V FIN, FLR. T.0 L/� I J I V I I V V TO MATCH EXISTING ADDITION EXIST. 2 NORTH ELEVATION 3. SCALE: 1/4" = 1'-0" 4 SOUTH ELEVATION 3,2 SCALE: 1/4" = 1'-0" AT COURTYARD T.O.P. GRADE RESUB Dec 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT �� r F� A3.'� 3 A5,1 \ II � / s210 CROSS SECTION 3, 7� SCALE: 1 /4" = 1'-0" -_/— - -_ _ Ij� I�E�` �iE .1�- �' i1 f- � � r �� -,7 � I< � _ � i r 1� 2018 Washington State Energy Code —Residential Table 046.3 (energy credits) 4. Additions less than 500 sf: 1.5 credits 5.4 Water heating system shall include one of the following: Electric heat pump water heater meeting the standards for Tier I of NEEA's advanced water heating specification Rheem TM Hybrid Electric is XE80T10H45U0 NEEA Tier 3 https://neea.org 1.5 RESUB Dec 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REGIST>=REQ ARCHITECT JRMTST pkSTA, cVE RAP`iS N O N F� ■ `�y� � REGISTEREQ J�� ARCHI�'ECT JRMTST pkSTA, cVE RAP`iS �C z W >� �� W PVA PRIMER � w 1/2" GWB � 2X6'S AT 16" O.C. ��� o R-21 INSUL. Z 0 ��� EXTERIOR SHEATHING PER o �� WEATHER BARRIER w BEVELED SIDING TO N MATCH EXISTING � ` N 'kV"Y � � /�� -�. I' R-3O BAIT INSUL 00 � ���: D �o ao ��� O � o 0 �` N �M- � ��' N �� RESU � � Dec 09 202 CITY OF EDMONDS ES DEPARTMENT ABBREVIATIONS ARCH. ARCHITECT GENERAL STRUCTURAL NOTES BAL. BALANCE (THE FOLLOWING APPLY UNLESS NOTED OTHERWISE) B. OR BOT. BOTTOM BTWN. BETWEEN BLDG. BUILDING BRG. BEARING C.I.P. CAST IN PLACE C.J. CONSTRUCTION JOINT 1. DESIGN CODE AND STANDARDS CL CENTERLINE a. 2018 IBC CLR. CLEAR b. OTHER DOCUMENTS REFERENCED BY THESE NOTES SHALL BE THE SPECIFIC CMU CONCRETE MASONRY UNIT EDITION REFERENCED BY THE BUILDING CODE SPECIFIED ABOVE, OR IF NOT COL. COLUMN SPECIFIED, SHALL BE THE LATEST EDITION. CONC. CONCRETE 2. DESIGN LOADS C.S.J. CLOSURE STRIP JOINT a. RISK CATEGORY = II EA. EACH b. ROOF LIVE LOAD 25 PSF E.E. EACH END c. SNOW LOAD 25 psf GROUND 25 psf MINIMUM E.F. EACH FACE d. FLOOR LIVE LOAD 40 PSF RESIDENTIAL E.J. EXPANSION JOINT e. LIVE LOAD AT BALCONIES, DECKS AND ROOF DECKS 1.5x(50psf) =75 PSF EL. OR ELEV. ELEVATION f. SEISMIC EQ. EQUAL i. Ss = 1.294, S� = 0.457, SITE CLASS "D" Sds-0.86, Sd1-0.56 E.S. EACH SIDE ii. BASIC SEISMIC FORCE RESISTING SYSTEMS) =LIGHT FRAMED WALLS E.W. EACH WAY SHEATHED WITH WOOD PANELS. F.O.C. FACE OF CONCRETE iii. CS = 0.133, R = 6.5. EQUIVALENT LATERAL FORCE PROCEDURE WAS USED. F.O.S. FACE OF STUD g. WIND LOAD F.O.W. FACE OF WALL i. BASIC WIND SPEED 110 (85 ASD) (MPH). (ASCE 7, 3 SECOND GUST) FTG. FOOTING ii. EXPOSURE B, Wall=18.4psf@ CORNERS LRFD, Ktz=1.0 GA. GAGE iii. IBC LOAD CASES PER SEC. 1605.2 OR 1605.3.1 ONLY Ko = 0.85 GALV. HOT DIP GALVANIZED 3. OSHA STANDARDS THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL G.W.B. GYPSUM WALL BOARD PROVISIONS OF THE CURRENT OSHA STANDARDS. THE GENERAL CONTRACTOR SHALL H. OR HORIZ. HORIZONTAL REVIEW THESE STRUCTURAL DRAWINGS FOR ANY NONCOMPLIANCE WITH OSHA I.B.C. INTERNATIONAL BUILDING CODE STANDARDS, TAKING INTO ACCOUNT THE GENERAL CONTRACTOR'S MEANS AND I.C.C. INTERNATIONAL CODE COUNCIL METHODS. THE GENERAL CONTRACTOR SHALL INFORM ENW OF ANY NONCOMPLIANCE I.F INSIDE FACE SO THE DRAWINGS MAY BE MODIFIED FOR COMPLIANCE PRIOR TO CONSTRUCTION. THE INC. INCLUDING K OR KIP (1000 POUNDS) GENERAL CONTRACTOR IS TOTALLY RESPONSIBLE FOR MEANS AND METHODS AS WELL L.W. LONG WAY AS JOBSITE SAFETY ON THIS PROJECT. N.F. NEAR FACE 4. FOUNDATION &SLABS THE FOUNDATION WAS DESIGNED FOR 1,500 psf. ASSUMED.FOOTINGS AND SLABS SHALL BEAR SOLELY ON UNDISTURBED NATIVE SOILS N.T.S. NOT TO SCALE AND BACKFILL TO BE 95% COMPACTED. ALL EXTEROR FOOTINGS TO BE FOUNDED 18" OC ON CENTER MIN. BELOW FINAL GRADE. FOR CANTILEVERED RETAINIG WALLS WITH ACTIVE O.F. OUTSIDE FACE BACKFILLUSE AN ACTIVE PRESSURE OF 35 PCF (USE NON -EXPANSIVE GRANULAR O.S. OUTSIDE BACKFILL. O.T.O. OUT TO OUT PL PLATE 5. CONCRETE REINF. REINFORCING a. F'c=3000 PSI. @ 28 DAYS 5 SACKS MINIMUM CEMENT PER CUBIC YARD FOR ALL REM. REMAINDER CONCRETE SLABS. CONTRATOR MAY PROVIDE DESIGN MIX TO MEET THE MINIMUM R.O. ROUGH OPENING REQUIREMENTS SECT. SECTIONS b. USE TYPE I/II CEMENT. FOR SPECIAL CONDITIONS ANOTHER TYPE CEMENT MAY BE SIM. SIMILAR REQUIRED. SUBMIT FOR APPROVAL. S.J SHRINKAGE JOINT c. MIXING AND PLACING OF ALL CONCRETE AND SELECTION OF MATERIALS SHALL BE STL. STEEL IN ACCORDANCE WITH THE ACI CODE 318. PROPORTIONING OF AGGREGATE TO SW SHEARWALL CEMENT SHALL BE SUCH AS TO PRODUCE A DENSE WORKABLE MIX WITH 4" SYMM. SYMMETRICAL MAXIMUM SLUMP (UNLESS SUPERPLASTICIZERS ARE USED) WHICH CAN BE PLACED T. TOP WITHOUT SEGREGATION OR EXCESS FREE SURFACE WATER. T.O.B. TOP OF BEAM d. FOR ADMIXTURES, SEE SPECIFICATIONS. T.O.F. TOP OF FOOTING T.O.S. TOP OF STEEL e. 3/4" CHAMFER ALL EXPOSED EDGES, UNLESS INDICATED OTHERWISE ON T.O.S. TOP OF SLAB ARCHITECTURAL DRAWINGS. T.O.W. TOP OF WALL . TYP. TYPICAL AT ALL SIMILAR PLACES 6. REINFORCING STEEL U.N.O. UNLESS NOTED OTHERWISE a. ALL CONCRETE REINFORCING STEEL SHALL BE DEFORMED PER ASTM A615, GRADE V.E.F. VERTICAL EACH FACE 60 (fy=60,000 psi) VERT. VERTICAL b. WELDED WIRE FABRIC (WWF) TO CONFORM WITH ASTM A185. V.F.F. VERTICAL FAR FACE c. LAP CONTINUOUS REINFORCING BARS 44 BAR DIAMETERS, 1'-10" MINIMUM UNLESS VFY VERIFY NOTED OTHERWISE. CORNER BARS (1'-10" BEND) TO BE PROVIDED FOR ALL V.I.F. VERTICAL INSIDE FACE HORIZONTAL REINFORCEMENT. V.N.F. VERTICAL NEAR FACE d. DETAIL STEEL IN ACCORDANCE WITH "ACI MANUAL OF STANDARD PRACTICE OF V.O.F. VERTICAL OUTSIDE FACE DETAILING REINFORCED CONCRETE STRUCTURES". REINFORCING HOOKS TO W.A.B.O. WASHINGTON ASSOC. OF BUILDING OFFICIALS COMPLY WITH STANDARD ACI HOOKS. W/ WITH e. COVER TO MAIN REINFORCEMENT TO BE: W/O WITH OUT i. BOTTOM OF FOOTINGS = 3 INCHES W.H.S. WELD HEAD STUD ii. FORMED SURFACES WEATHER &EARTH FACE = 1-1/2 INCHES @qT AT iii. FORMED SURFACES INTERIOR FACE = 3/4 INCHES 7. REINFORCING STEEL WELDING a. USE ASTM A706 GRADE 60 (fy = 60,000 psi) FOR ANY REINFORCING THAT IS TO BE WELDED. SUBMIT MILL CERTIFICATES. b. FOLLOW PROCEDURES OF ANSI/AWS D1.4-92, "STRUCTURAL WELDING CODE REINFORCING STEEL". c. USE CERTIFIED WELDERS. d. PROVIDE SPECIAL INSPECTION PER CODE. 8. FRAMING LUMBER a. GRADES AND STRESSES SHALL CONFORM WITH THE LATEST EDITION OF "WESTER LUMBER GRADING RULES", WWPA OR "STANDARD NO. 17 GRADING RULES FOR WEST COAST LUMBER", WCLIB. ALL LUMBER S4S AND S-DRY UNLESS NOTED OTHERWISE. b. EACH PIECE SHALL BEAR A VALID GRADE STAMP THAT IS NOT TO BE REMOVED. BOLT HEADS AND NUTS BEARING AGAINST WOOD SHALL HAVE A STANDARD CUT WASHER. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESERVATIVE TREATED. USE STANDARD LENGTH COMMON NAILS FOR ALL NAILING EXCEPT WHERE SHORTER NAILS PROVIDE THE REQUIRED PENETRATION IN DIAPHRAGMS. 9. GLU -LAMINATED WOOD MEMBERS a. GLUM -LAMINATED WOOD BEAMS, COAST REGION DOUGLAS FIR CONFORMING WITH ANSI/AITC A190.1-07 AND AITC 117-10 OF APA-EWS Y117. USE COMBINATION EWS 24V4(DF/DF) Fb=2400PS1, Fvx=190 PSI, FOR SIMPLE SPAN BEAMS AND COMBOINATION EWS 24V8 (DF/DF) Fb=2400PS1, Fvx=190PS1 FOR CANTILEVERED BEAMS. ADHEASIVE TO BE "WET USE". ALL MEMBERS TO FIT SNUG AND TIGHT IN THEIR CONNECTIONS AND DEVELOP FULL BEARING AS INDICATED 10. MANUFACTURED WOOD BEAMS a. MANUFACTURED BY WYWERHAUSER IN ACCORDANCE WITH VAR-1008 &ESR 1387. MATERIALS TO COMPLY WITH ICC ES REPORT NOI. ESR-1387. MICROLAM LVL 2.0E Fb=2750PS1, TIMBERSTRAND LSL 1.3e Fb=1700, PAPRALAM PSL 2.Oe Fb=2900. MEMBERS TO BE MANUFACTURED FREE OF FINGER JOINTS, SCAFS OR MECHANICAL CONNECTIONS. ADHESIVES TO BE WATERPROOF TYPE CONFORMING TO ASTM D-2559. MANUFACTURED IN AN APPRVED PLANT AND IDNETIFIED BY A STAMP INDICATING THE PRODUCT TYPE &GRADE, NER REPORT NUMBER, MANUFACTURORS NAME, PLANT NUMBER AND INDEPENDENT INSPECTION AGENCY'S LOGO. ALL MEMBERS TO FIT SNUG AND TIGHT IN THEIR CONNECTIONS AND DEVELOP FULL BEARING AS INDICATED. 11. WOOD TRUSSES a. DESIGN FOR GRAVITY AND WIND UPLIFT LOADS SHOWN ON PLANS. ACCOUNT FOR HORIZONTAL WIND OR SEISMIC REACTIONS FROM WALLS TO TRUSS CHORDS INDICATED ON DRAWINGS. VERIFY SIZE AND LOCATION OF ALL LOADS DUE TO MECHANICAL, PLUMBING AND ELECTRICAL. SEE PLANS FOR ADDED LOADS SUCH AS PLANTERS ETC. SECTIONS AND PLANS INDICATE ONLY OUTLINES OF TRUSES. MANUFACTURER TO SELECT THE WEB AND CHORD MEMBERS REQUIRED TO CARRY LOADS. b. PLATE MANUFACTURER SHALL BE A MEMBER OF THE TRUSS PLATE INSTITUTE. c. SHOP DRAWINGS TO BE STAMPED BY ONE ENGINEER LICENSED IN THE STAE IN WHICH THE PROJECT IS LOCATED 12. WOOD STRUCTURAL PANELS a. COMFORM WITH THE U.S. DEPARTMENT OF COMMERCE VOLUNTARY PRODUCT STANDARDS. PS1-09, STRUCTURAL PLYWOOD OR PS2-10 PERFORMANCE STANDARD FOR WOOD BASED STRUCTURAL USE PANELS. ALL PANELS RATED EXPOSURE 1. b. ROOF SHEATHING -'/s" CDX 24/0. UNO ON PLANS NAIL WITH 8D COMMON WITH 1 '/2" PENETRATION. c. WALL SHEATHING -'/2 CDX 24/0. UNO ON PLANS NAIL WITH 8D COMMON WITH 1 '/s" PENETRATION. d. FLOOR SHEATHING - 3/4 T&G. GLUE &NAIL WITH 8D COMMON WITH 1 '/2" PENETRATION. 13. 14. SPECIAL INSPECTIONS a. INSPECTIONS ARE TO BE PER THE CODE INDICATED ABOVE AND ARE TO BE BY AN INDEPENDENT TESTING LAB APPROVED PRIOR TO STARTING CONSTRUCTION BY THE BUILDING DEPT. AND THE ARCHITECT. INSPECT ALL SHOP WELDING UNLESS THE SHOP IS CERTIFIED BY THE LOCAL BUILDING DEPARTMENT. b. FOUNDATION: i. SOILS ENGINEER TO INSPECT PILE INSTALLATION. c. CONCRETE: i. TAKE CONCRETE CYLINDERS AS REQUIRED, VERIFY SLUMP AND STRENGTH. SPECIAL INSPECTION IS REQUIRED DURING THE TAKING OF TEST SPECIMENS AND PLACING OF ALL REINFORCED CONCRETE. d. REINFORCING: i. VERIFY ALL REINFORCING IS PLACED IN ACCORDANCE WITH THESE DRAWINGS. CHECK FOR REQUIRED COVER, SIZE, SPACING, LAP AND GRADE. SPECIAL INSPECTION IS REQUIRED DURING THE PLACING OF REINFORCING STEEL. e. WELDING: i. SPECIAL INSPECTION IS REQUIRED DURING ALL STRUCTURAL WELDING. INSPECT ALL FIELD WELDING -VERIFY CERTIFICATION OF WELDERS. CONTRACTOR SHALL PAY FOR REWELDING AND REINSPECTION OF ALL WELDS NOT MEETING SPECS. INSPECTOR SHALL NOTIFY STRUCTURAL ENGINEER OF WELDS NOT MEETING SPECS. f. CONC. &MASONRY EXPANSION ANCHORS i. COPY OF ICC REPORT FOR ANCHORS USED MUST BE AVAILABLE AT JOB SITE. VERIFY ANCHORS IN ACCORDANCE WITH REPORT. g. CONC. &MASONRY ADHESIVE ANCHORS i. COPY OF ICC REPORT FOR ANCHORS AND ADHEASIVE USED MUST BE AVAILABLE AT JOB SITE. VERIFY ANCHORS IN ACCORDANCE WITH REPORT. ii. VERIFY INSTALLERS ARE CERTIFIED FOR HORIZONTAL AND OVERHEAD INSTALLATIONS. a. . 15. SHOP DRAWINGS a. SUBMIT 4 SETS OF PRINTS (U.N.O. BY ARCHITECT) OR ELECTRONIC PDF FILES, OF SHOP DRAWINGS TO ENGINEER FOR REVIEW AFTER CONTRACTOR HAS REVIEWED & STAMPED FOR COMPLIANCE AND PRIOR TO FABRICATION FOR: i. STRUCTURAL STEEL, MISCELLANEOUS STEEL ii. REINFORCING STEEL. iii. WHEN SHOP DRAWING SUPPLIER MAKES A CHANGE FROM THESE DRAWINGS IT IS TO BE CLEARLY FLAGGED AND CLOUDED. CHANGES NOT FLAGGED AND CLOUDED ARE TO BE CONSIDERED AS UNACCEPTABLE EVEN WITHOUT BEING COMMENTED ON IN THE SHOP DRAWING REVIEW PROCESS. THE SUPPLIER OF THE ITEM CONTAINING THE CHANGE SHALL BE RESPONSIBLE FOR CHANGING THE ITEM BACK TO AGREE WITH THESE DRAWINGS. iv. SHOP DRAWINGS ARE AN ERECTION AID, AND STRUCTURAL DRAWINGS SHALL TAKE PRECEDENT OVER THE SHOP DRAWINGS. 16. SPECIAL CONDITIONS a. CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. b. CONTRACTOR SHALL NOTIFY ENGINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION. c. SEISMIC BRACING AND ANCHORAGE OF MECHANICAL OR ELECTRICAL EQUIOMENT AND OTHER MECHANICAL PIPING, FIXTURES, ETC NOT SPECIFICALLY SHOWN ON THE STRUCTURAL, MECHANICAL OR ELECTRICAL DRAWINGS SHALL BE DESIGNED BY A REGISTERENGINER IN THE STATE OF THE PROJECT. 17. STRUCTURAL DRAWINGS a. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS AND ALL OTHER CONTRACT DOCUMENTS FOR BIDDING AND CONSTRUCTION. b. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ALL DISCREPANCIES PRIOR TO BID AND CONSTRUCTION c. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE BUILDING LAYOUT DIMENSIONS AMONG ALL TRADES INCLUDING SHOP FABRICATED ITEMS. X w 0 z Q U :: `_ e t �,��: ':• ►• REGI57EREQ ARCHITECT RESUB Dec 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REGISTI=REQ ARCHI�'ECT A B C A B C JRM�S �otisTA. �yE �,;:`i �_ S I CRAWL SPACE ACCESSI % PLY�D �y/ 8d COM I I I I 18" X 24" SIDE MIN. NAILS @ 6" O.C. EDGES 12" O.C. FIELD 1 ------------------------- 1 � O -------------- -- ------ I 16" FOOTING I \ I I I B_1 I I I I 24" X 24" / I I X 11 1/4" FOOTING H_2 I T-1 TRUSSES @ 24" O.C. B-1 � — B-1 � — g_1 i I 4x6 POST / g-1 B-1 4x8 DF#2 N O EQ. � ®J EQ. ® 9 EQ. i � c; H-2 H-1 2-2X6 DF#2 `� i A5.1 I I J-1 2X10 @ 16 O.C. DF#2 \ � H-2 2-2X6 DF#2 I I B-1 4X10 DF#2 I � H-2 I I \ / I I I I I B-1 I I ------------------------J � H-1 H-1 ' H-1 H-1 --------------------------� 2 — 2 0 0 \ � i � �� � \ �� � �/�"�'-� i 0 0 ��� �hk�`: �� RESUB Dec 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ��F- i l ,. �F } _ �r I �F ii NAIL PER SHEARWALL SCHEDULE v D \\\j\\/\\/\\/\ �"� �. !! �,i►.iii�i �s�r�,�����11'il�q'�,r I�ie�in � j 11 � �' �� �' 1• � • . • . REGISTE{�Ep ARCHITECT `JAM -ES CgkSTA. ��15 Z W W_ W Z O w N N ��� r j' � � ■Y DEPARTMENT