Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED SITE PLAN 4.24.20
11 i - _- I .P Nothing in the permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action. APPROVED BY PLANNING Apr 24 2020 ZOW RS-12 --- ComerNFig&I�,N SobakA t*ed * W" . Froo 25' S= 28' Sides 10,_-_.._.w. E= 11' / W= 55' Rev 25' N= 97' OdieC 25' 24' 3" * Actual setbacks are to the proposed addition 320 XISTING WATER SERVICE- so � 322 kT11^0 1 \ 1 1 \ 1 1 aU: \ \ \ 4E \ EXIS�G 12-' STORM \ \ 316 DRAIN \ \ OUTFALL IE- 5' \ CB \ EXISTING 8" STOR \ \0 \ \ 308 ` I 310 6" STORM DRAIN / \ 312 314 \ \ EXISTING DECK Q ! 230 sf ���2 p F C- / 316 ` ! EXISTING 18" STORM DRAIN i RESIDENCE \ TH PLACE SW ING HOUSE \ 566 sf DOWNSPOUT / \ \ VV JI \ 1> EXISTING GARAGE p l FFE 318.5 J EXISTING SANITARY SERVICE \ EXISTING TRENCH DRAIN \ - TIE INTO NEW \ \ \ \ ATUM 318.0 �9. \ STORAGE CONCRETE p� 23 sf WALK 1� 0 a / / ROOF OVERHANG SHALL NOT ! CONCRETE EXTEND MORE THAN 30" INTO 'GARAGE / ! BUILDING SETBACK FFE 318.0 OV RED NTR ! 6' STORM DRAIN ! � / / ��5 � wF�SFMF �F ! � c319 BOW O ! SEGMENTAL BLOCK RETAINING WALL \ ! - MAX. HEIGHT = 3'-0" WALL MAY / \ / NOT ENCROACH INTO DRAINAGE -REMO 4 / EASEMENT - SEE ECDC SETION ! 18.40.020 FOR PROHIBITED 8" FI ! ROCKERIES. / 0 N�6 sU1tc l h4tu,� FvtoM 22 2%' F DJAV m" pcn441TTW- OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL. AND DRAINAGE 320 N i RA ft S SS1 MR LOCATING ALL ON -SITE UTILITIES. LEGAL DESCRIPTION STEELE PARK BLK 000 D-00 LOT 2 TGW EQ & LIND INT IN TR 100 ASSESSOR'S PARcEL NO 00757200000200 SITE DATA'�.,�' SITE AREA: 12,200 sf ZONING: RS12 J LOT COVERAGE: 35% FRONT SETBACK 25', SIDES 10' AND REAR 25' <1 z HEIGHT: 25' 0 LLI CODES C�'1 2015 SRC UJ Y r 2015 WASHINGTON STATE ENERGY CODE (WSEC)"" Q BUILDING DATA L rs OCCUPANCY: R3 BUILDING TYPE: VB SCOPE OF WORK ADDITION TO EXISTING SINGLE FAMILY RESIDENCE INCLUDING A GARAGE WITH SECOND FLOOR OVER GARAGE AND INFILL OF EXISTING CRAWLSPACE TO CREATE NEW BASEMENT. BUILDING AREA,© GREENWALK DESIGNS L-C. FIEGISTOM EXISTING FIRST FLOOR: 1,190 SF Ile EXISTING SECOND FLOOR: 830 SF SECOND FLOOR ADDITION: 567 SF O• aAAhIIE ' TOTAL LIVING SPACE: 2,587 SF s A-M OF WASH! ' COVERED GARAGE ENTRY 16 SF EXISTING GARAGE: 476 SF EXISTING DECK: 230 SF GARAGE & STOR ADDITION: 565 SF TOOTAL GARAGE/ENTRY AREA: 1,057 SF � p2o�tys�� nruv�-rvl�y:�q a s�G�-� L OT COVERAGE MAXIMUM LOT COVERAGE 35% BUILDING FOOTPRINT 1,190 SF GARAGE & STOR. 1,041 SF EXISTING DECK: 230 SF V COVERED PORCH 39 SF TOTAL BUILDING AREA 2,500 SF W o 2,500 / 12,200= 207. LOT COVERAGE _0 Cn 09 BUILDING HEIGHT CO 0- a W -a PROJECT DIRECTORY BUILDING HEIGHT ALLOWED 25' '9-0 C6 A 317.0 0 OWNER: RANDY B 318.0 W Z 6805 157th C 319.0 O th PPI SW D 318.0 2 M EDMONDS, WA 98028 318.0 O ARCHITECT: w GREENWALK DESIGNS MAXIMUM SLOPED ROOF HEIGHT = 343.0' Q 12731 39th AVE. NE SEATTLE, WA 98125 SHEET INDEX MM (206) 550-9296 A1.1 SITE PLAN - COVER NOTES STEVE BARNES AC1 GENERAL NOTES sbarnes@cornerstonearch.com A2.1 FIRST FLOOR PLAN - WINDOW TYPES - NOTES STRUCTURAL ENGINEER: A2.2 SECOND FLOOR PLAN - WALL TYPES - STAIR DETAILS A3.1 EXTERIOR ELEVATIONS PETERSON, STREHLE, MARTINSON, INC. A3.2 EXTERIOR ELEVATIONS 2200 SIXTH AVE., SUITE #601 A4.1 BUILDING SECTIONS SEATTLE, WA 98121 A4.2 BUILDING SECTIONS (206) 622-4580 A6.1 ROOF PLAN - DETAILS S1 STRUCTURAL NOTES FOUNDA1ON DETAILS DAVID STUBBS S2 FIRST FLOOR FRAMING & FOUNDATION PLAN - DETAILS S3 SECOND FLOOR FRAMING PLAN - DETAILS S4 ROOF FRAMING PLAN R ATIV"EVI 1ON TO ANY 1.1111"Pr -_ WSEC 2015 PRESCRIPTIVE ENERGY Y RbQUWS'EF'AAATE PERMIT CODE COMPLIANCE ADDITION: 1.5 CREDITS REQUIRED PER WSEC R406.2 OPTION 1d (EFFICIENT BUILDING ENVELOPE) - 0.5 ENERGY CREDIT VERTICAL FENESTRATION U=0.24 APPROVED BY ENGINEERING OPTION 2a (AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION) - 0.5 ENERGY CREDIT -� REDUCED AIR LEAKAGE TO 3.0 AIR CHANGES PER HOUR MAXIMUM. HIGH EFFICIENCY Date: 3 'Z/z0zo WHOLE HOUSE FAN (MAXIMUM 0.35 WATTS/CFM) IN LAUNDRY ROOM ON TIMER NOT Pm Pazr_R1T6CT STU6INTERFACED WITH FURNACE FAN. i GISTINXl ftM6`5 IMPE1'WIVK5 SLAVtC-P< ,JIArtM n-""OPP 0%Sc0A1L64Z> -ru 6�cIS7I&) 7 OPTION 5a (EFFICIENT WATER HEATING) - 0.5 ENERGY CREDIT C_rs - * PYdol:bse� �rniv►�s� ,s SHOWERHEAD AND KITCHEN SINK FAUCETS RATED AT 1.75 GPM OR LESS, LAVATORY UIqbM 7-VW saf-t� FAUCETS RATED AT 1.0 GPM OR LESS wwPc.-*_�T SySrE*t TOTAL: OPTION 1 d+2a+5a = 1.5 CREDITS NORTH SITE PLAN SITE SCALE: 1"= 10'-0" 6 " a II char ge to I 'J 4 r,,a ? IUD C-ly .hp Is caUi ",J O � Q r O W W CD 0 Z U I W _J W W O 0- O � 1 _ (� Z N � ~ W O N O C/) W � w Q 0 W