REVIEWED-BLD2022-0179+Structural_Calculations+2.8.2022_1.41.16_PM+2668846RECEIVED Feb 10 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Junejo Residence 8516 184" St SW Edmonds, WA Prepared for: Nazia Junejo Job #: 10952-2021-04 Date: February 8, 2022 BLD2022-0179 REVIEWED BY CITY OF EDMONDS E BUILDING DEPARTMENT SEATTLE 2124 Third Ave, Suite 100, Seattle, WA 98121 0 206.443.6212 ssfengineers-com Iorc,NEE-1-A TACOMA 934 Broadway, Suite 100, Tacoma, WA 98402 0 253.284,9470 Criteria Sheet Codes Project Location Structural IBC 2018 Street & Number 8516184th St SW Loading ASCE 7-16 City: Edmonds State: WA Wood: NDS 2018 ZIP: 98026 Steel: AISC 360-16 Concrete: ACI318-14 Latitude: 47.8321 N Masonry: TMS 402/602-16 Longitude:-122.3489 W Ground Elevation 345 ft Occupancy Category Risk Catpnorv, a ASCF 7 Tahlp 1.5-1 Seismic Load Summary: Analysis Procedure: Equivalent Lateral Force Procedure Lateral System: Light -frame (wood) Walls Sheathed with Wood Structural Panels Rated for Shear Resistance R: 6.50 Ca 4 Base Shear V = 4 kips Do 2.5 Ss= 1.302 S1= 0.461 SDS= 1.00 SDI= 0.57 Cs 0.154 IE 1.0 Story Information # Stories Above Grade (Including Mezzanine Levels) 1 Horizontal and Vertical Irregularities: Is the building a "Regular Structure"? (No horizontal or vertical irregularities) Yes Wind Load Summary: f$' o 14wda Be Ch Par I �V SAWw w Park f 7 o ii: i:o.k. Lynnwood JI I Ii PdC YJ :SS Fdmonds @SEgbF Map data (D2022 V= 98 KZT 1.00 Exposure = B Dead Loads: Roof Floor Roofing 1 psf Finish Floor 2 psf 1/2" Sheathing 1.8 psf 3/4" Sheathing 2.7 psf Rafters @ 24" oc 2 psf Joists @ 16" oc 2.5 psf Misc./Mech. 1.5 psf Misc 2 psf Ceiling Finish 2.8 psf 9.2 psf 9 psf Use 10 psf Use 10 psf Add 5 psf for Seismic 14 psf Live Loads: Snow 25 psf Floor 40 psf Soils: Soils Report Provided? No To be approved by the authority having jurisdiction, per 11.8.2 exception. Allowable Bearing 1500 psf Active 55/35 pcf (Restrained/Unrestrained) Sliding,µ 0.3 Seismic Surcharge 8H Passive 250 pcf 0 STRUCTURAL ENGINEERING Junejo Residence Criteria DATE PROJ. # DESIGN SWJ SHEET 1 E 0 w m G (+7 WE Seismic Design ASCE 7-16 Seismic Analysis Equivalent Lateral Force Procedure Seismic Force Resisting System Per Bearing Wall Systems Table 12.2-1 System I Light-frame (wood) Walls Sheathed with Wood Structural Panels Rated for Shear Resistance Type: Seismic Design Cat. D Risk Category II Site Class D (Default) Diaphragm Flexibility Flexible Ss 1.302 g S, 0.461 g R 6.50 Cd 4.0 no 2.5 le 1.00 hn 10.5 ft Ct 0.02 x 0.75 Ta 0.12 sec T 0.12 sec To 0.11 sec Ts 0.57 sec TL 6.00 sec 1.20 Fv 1.84 SMS 1.56 g SM1 0.85 g Ds 1.000 g SM 0.565 g Cs 0.154 Controls 0.745 0.010 Cs, design 0.154 Bldg. Weight 27.0 k V C W , II, or III, or IV per Table 1.5-1 assumed default soil properties, per 11.4.3. ?% in 50 yr, Latitude & Longitude lookup in 50 yr, Latitude & Longitude lookup fable 1.5-2 fable 12.8-2 fable 12.8-2 Building Period Per Alternate Analysis q.12.8-7 T (sec) Per Geotech Report fable 11.4-1 fable 11.4-2 F q.11.4-1 q.11.4-2 q.11.4-3 q.11.4-4 q.12.8-2 Eq. 12.8-3 need not exceed, T < Tt q.12.8-5 or12.8-6 minimum Section 11.4.8 Exception 2 Applied s 4.2 k Eq.12.8-1, Strength Level Base Shear V = Cs s,iW 2.9 k Eq.12.8-1 ASD Base Shear Vertical Distribution ASD o= 1 k= 1.000 Section 12.8.1.3 Exceptions Regular Structure Yes 5 5 Stories above grade Yes T 5 0.5s Yes p =1.0 Yes Not Site Class E or F Yes Risk Category I or II Yes IT all exceptions are met, DDS may De to Ken as 1, but not less than 0.7*(Calculated SDs) T. = Cthn Eq. 12.8.7 SMS = F.SS Eq. 11.4-1 SM1 = F„S1 Eq. 11.4-2 SDS = 2/3 SMS Eq. 11.4-3 SD1 = 2/3SM1 Eq. 11.4-4 CS = (SDS Eq. 12.8-2 CS T RIISD1 Eq. 12.8-3 CS = D1 T T L) Eq. 12.8-4 CS >_ 0.044SDSIe Eq. 12.8-5 CS >_ 0.01 Eq. 12.8-5 CVX = wxh,, 1 wxhk Eq. 12.8-12 F = Ei xF`/ n WP x Eq. 12.10-1 PxEi_X wr Fpx >_ 0.2SDSIewpx Eq. 12.10-2 Fpx <_ 0.4SDSIeWpx Eq. 12.10-3 Level h, (ft) W, (k) h,k (ft) W,h k Story Shear ASD Diaphragm Force (p not included) C x (%) Fx (k) SV (k) Fpxcaic Fpx.mi. F,max Fpx.d-q. Y-F,/F. 2 1 10.5 1 27 10.5 284 1.000 1 2.9 2.9 2.9 1 3.8 1 7.6 1 3.8 1.30 E 1 27.0 1 284 1 1 2.91 Junejo Residence Seismic Criteria STRUCTURAL ENGINEERING DATE 21312022 PROJ. # DESIGN SWJ SHEET 2 r+D Wind Design - MWFRS ASCE 7 Chapter 27 - Directional Procedure Design Method ASD Location and Building Dimensions Wind Coefficients Exposure B V= 98 mph Ka 0.85 Table 26.6-1 Kh= 0.57 Table 26.10-1 KQ 0.99 Table 26.9-1 G= 0.85 26.9.4 Transverse Wind Pressures L/B = 0.41 h/L = 0.38 Pressure Coefficients from Fiaure 27.3-1: Bldg Face Cp Windward Wall 0.8 Leeward Wall -0.50 Windward Roof -0.8 /-0.18 Leeward Roof -0.40 Wall Pressures (Unfactored): Calculate Kzt? Yes Kzt 1.00 Roof Type Gable Roof Angle - TransverseDir 10 degrees Roof Angle - Long Dir 0 degrees Ground to top of roof 11.75 ft Bot of roof to top of roof 2.5 ft Mean Roof Height, h 10.5 ft Short Plan Dimension 28 ft Long Plan Dimension 69 ft Parapet? No Ground to top of parapet ft Average l? rapetHeightl ft Velocity Pressure at Mean Roof He, qh = 11.9 psf ASD Roof Pressures (Unfactored) ASD Ht K, q vans mans .ens Ps 0-15 0.57 11.76 8.00 5.04 9.6 15-20 0.62 12.80 8.70 5.04 9.6 20-25 0.66 13.62 9.26 5.04 9.6 25-30 0.7 14.45 9.82 5.04 9.6 30-40 0.76 15.69 10.67 5.04 9.6 41-50 0.81 16.72 11.37 5.04 9.8 51-60 0.85 17.54 11.93 5.04 10.2 61-70 0.89 18.37 12.49 5.04 10.5 71-80 0.93 19.19 13.05 5.04 10.9 81-90 0.96 19.81 13.47 5.04 11.1 91-100 0.99 20.43 13.89 5.04 11.4 Wind Base Shear 3.89 kips Junejo Residence Wind Criteria STRUCTURAL ENGINEERING Windward Leeward Horiz Proj (psf) Max in -1.8 -8.1 1 -4.0 4.80 DATE 21312022 PROJ. # DESIGN SWJ SHEET 3 ti cn 15'-9" C (?) L(3 )- - - - CI ) "N61TUDINAft v Lti Is•�-S 1s Mm- Li rF 3qZ`� 3 C, Vv b o/UNIGINEERING RUCTURAL Junjejo PROJECT C3 6gq� L f 3\C1 2& 1 -iRgNSy�Y-��i ('�l lW AND (I) CZ �/ I z13`43 19�1b�e L« .v, 010 Tor 'FR or SvJ M -I-LH �ysb 6) �33U;Q 53.3 OM L� 7�6 3�i Z `ice Lvb `v io NpV2 2215 2/1 /22 DATE 10952-2021-04 PROD# SWJ DESIGN I SHEET Beam B1 GL 3 1/2 x 18 W= 455 plf R= 5,517 Ibs L= 24.25 ft M= 33,446 ft-Ibs b= 3.50 in Fb= 2,124 psi d= 18.00 in Fv= 115 psi E= 1800 ksi A= 1.16 in Cv= 0.98 <_1.0 1 1 1/ 252 W 0 Beam B2 Typ Roof Rafter - 2x10 W= 70 plf R= 490 Ibs L= 14 ft M= 1,715 ft-Ibs b= 1.50 in Fb= 962 psi d= 9.25 in Fv= 47 psi E= 1300 ksi A= 0.47 in Cv= 1 1.00 <_1.0 I 1 1/ 357 D W Beam B3 (2) 2x8 HDR - Max Span W= 280 plf R= 1,120 Ibs L= 8 ft M= 2,240 ft-Ibs b= 3.00 in Fb= 1,023 psi d= 7.25 in Fv= 66 psi E= 1300 ksi A= 0.21 in Cv= 1 1.00 151.0 1 1 1/ 461 0 W STRUCTURAL ENGINEERING 2124 Third Avenue. Suite 100. Seattle. WA 98121 www.swensonsayfaqet.com Office: 206.443.6212 Fax: 206.443.4870 Project: Junejo Date: 02/08/22 Project #: Design: SWJ Sheet: