Loading...
approved Calc Package 3.20.20ST Engineemp Tel: 425-891-5111 17614 NE 291" St; Redmond, WA 98052 DESIGN CALCULATIONS Phaysith's Interior Remodel 9327 217t" St SW Edmond WA 98020=3943 Revision #2 03/18/20 a" O R T CM MEMBER REPORT PASSED Level, #6 Door Header 2 piece(s) 2 x 6 Hem -Fir No. 2 Overall Length: 4' 7" 4' I 0 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1320 @ 2" 4253 (3.50") Passed (31%) 1.0 D + 1.0 L (All Spans) Shear (Ibs) 888 @ 9" 1650 Passed (54%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 1301 @ 213 1/2" 1393 Passed (93%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.060 @ 2' 3 1/2" 0.106 Passed (L/854) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.078 @ 2' 3 1/2" 0.213 Passed (L/652) 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/480) and TL (L/240). • Top Edge Bracing (Lu): Top compression edge must be braced at 4' 7" o/c based on loads applied, unless detailed otherwise. • Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 4' 7" o/c based on loads applied, unless detailed otherwise. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Total 1 - Stud wall - SPF 3.50" 3.50" 1.50" 312 1008 1320 Blocking 2 - Stud wall - SPF 3.50" 3.50" 1 1.50" 312 1008 1320 Blocking • rsiocKmg raneis are assumea to carry no ioaas appnea airecay aoove tnem ano the run ioaa is appneo to the memoer Deing oesignea. Vertical Loads Location (Side) Tributary Width Dead (0.90) Floor Live (1.00) Comments 0 - Self Weight (PLF) 0 to 4' 7" N/A 4.2 1 - Uniform (PSF) 0 to 4' 7" (Front) 11' 12.0 40.0 Default Load System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Ken Nguyen ForteWEB Software Operator Job Notes Ken Nguyen NT Engineers (425) 891-5111 housedesign4u@outlook.com 3/19/2020 12:58:52 AM UTC ForteWEB v2.4, Engine: V8.0.1.4, Data: V7.3.2.0 Weyerhaeuser File Name: Edmonds Interior Remodel Page 1 / 1