approved plans 4.22.20 flattenedC4 XJb
L4 XJb
(_'OG'E5
201 International 1 uildinq Code ( 00
20 International I?e5idential Code (II?0
RECE55ED LIGHTING: (R402.4.4)
* RECE55ED LUMINAIRE5 INSTALLED IN THE BUILDING THERMAL
ENVELOPE SHALL BE TYPE IC -RATED AND CERTIFIED UNDER
A5TM E263 A5 HAVING AN AIR LEAKAGE RATE NOT MORE THAN
2 CFM WHEN TESTED AT A 1.57 P5F PRE55URE DIFFERENTIAL
AND SHALL HAVE A LABEL ATTACHED SHOWING COMPLIANCE
WITH TH15 TEST METHOD. ALL RECESSED LUMINAIRES SHALL
BE SEALED WITH A GASKET OR CAULK BETWEEN THE HOU5ING
AND THE INTERIOR WALL OR CEILING COVERING.
CARBON MONOXIE DETECTOK5:
FOR NEW CONSTRUCTION, AN APPROVED CARBON
MONOXIDE ALARM SHALL BE INSTALLED OUT5IDE OF EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATELY VICINITY OF
THE BEDROOMS IN DWELLING UNITS AND ON EACH LEVEL
OF THE DWELLING AND IN ACCORDANCE WITH THE
MANUFACTURES DIRECTIONS.
SMOKE DETECTOR5:
SMOKE ALARMS SHALL BE I N5TALLED IN THE FOLLOWING
LOCATIONS:
1. IN EACH 5LEEP1 NG ROOM.
2. OUT51 DE EACH SEPARATE 5LEEP1 NG AREA IN THE
IMMEDIATE VICINITY OF THE BEDROOMS.
3. ON EACH ADDITIONAL STORY OF THE DWELLING,
INCLUDING BASEMENTS, BUT NOT INCLUDING
CRAWL5PACE5 AND UNINHABITABLE ATTICS. IN
DWELLI NG5 OR DWELLI NG5 U N ITS WITH SPLIT LEVEL5 AND
WITHOUT AN INTERVENING DOOR BETWEEN ADJACENT
LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER
FLOOR SHALL SUFFICE FOR THE ADJACENT LOWER LEVEL
PROVIDE THAT THE LOWER LEVEL 15 LE55 THAN ONE FULL
STORY BELOW THE UPPER LEVEL.
4. SMOKE DETECT05 TO BE HARWIRE, INTERCONNECTED
WITH BATTERY BACKUP.
Valuation of the Work Notes:
Total
—t—Cedar Si
—
T
ro
:k St <
M
i-st
Fir St -
I
k R K
H001
_ $ 1201000
1
—r%iaerai��—�uuera[ I
N
Walnut -St Yost Park
D— `Y01n l,`,
Spruce St aj'
goWdo'n �4
I y
a
2141h PI SN! D�
°$ o
T
9327 2117th
16th PI SW
/r7—Westgate
Elementary School
Vicinity Map
:�
Wt4w S�v
�o
w
3 a
J
4J W
Q+ t a
5 <
L
' 4Y220th-StII
7 a a
1> ? a
18th St
I t-220th-St-SW
T
14
PROJECT:
PHAYSTH'S INTERIOR REMODEL
INTERIOR REMODEL PER PLAN.
SUBJECT SITE ADDE55:
9327 217TH SIT SW , EDMONDS, WA 98020-3943
LEGAL DESCRIPTION:
WICHSERS DEL MAR ADD NO 6 BLK 001 D-00 -
LOT 1
PARCEL TAX ID #: 00612900100100
U5E CODE: 111 Single Family Residence - Detached
5TRUCTU ICE CLA55: Dwelling
5TRUCTURE TYPE: 1 Story w/Basement
YEAR BU I LT: 1955
Buildin6j Coverage: 5.f.
Main Building 931
Atached Garage 308
Shed/ 5tora�je 270
Total 1 , 509
Lot Size 8,720
% of Lot 17.3
AREA 5UMMARY: Interior Remode
Main Floor = 93 1 5f
Basement = 909 1
Loft = 273
Attached Garage = 308
Total = nKiD&
a CONTACT INFORMATION:
G
OWNER
ACJ Holdings LLC
Bryan Phaysith
Phone: 206-393-2167
i Email: aejholdngs18@gmail.com
CONTRACTOR
Owner
STRUCTURAL DESIGN ENGINEER
Address: 4329147th PI SE
Mill Creek WA 98012
Ken Nguyen Address: 17614 NE 29th St
PHONE: 425-891-5111 Redmond WA 98052
EMAIL : housedesign4u@outlook.com
N0TE9:
* ELECTRICAL OR PLUMBING UNDER SEPARATE PERMIT.
* ALL REPLACED EGRESS WINDOWS AND DOORS REQUIRED INSPECTION.
* EX15TING CEILING, WALL OR FLOOR CAVITIES EXP05ED DURING
CONSTRUCTION PROVIDED THESE CAVITIES ARE FILLED WITH INSULATIONS,
SHALL DE RE -INSULATED A5 FOLLOWS:
2x4 Wall Use R- 15
2xG Wall use R-2 1
Floor Minimum R-30
Attic Ceiling R-49
City
Building
Department
Work Interior Remodel / 909 unfinished basement to conditioned space
Address 9327 217th Street SW
Owner ACJ holdings LLC
Approved Date
Building Official
04/03/2020
Do4-.avoE.*• W. 9 A
Permit Number
BLD2020-0241
CITY OF EDMONDS
BUILDING DIVISION
APPROVED PLAN
V&
02-18-20 REV Al
425-891-5111
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
OBTAIN ELECTRICAL PERMIT FROM
STATE LABOR & INDUSTRIES
APPROVED BY PLANNING
�2z cro
Apr 20 2020
02/12/20
Phaysith's Interior Remodel
9327 217th St SW
Edmonds WA 98020-3943
GENERAL NOTES
DATE
2-12
2020
SHEET
1 21
) -712"
N'rs
NT Enaineers —*— 17614 NE 29th St - Redmond WA 98052 —*— housedesian4u(cboutlook.com
4' AJV
LT AJt
EXTE
Ln
Cu
0
0
M
Ln
CU
0
GAI.,,VL VV/'lLL `VV I LII YL)
(Exiting) LOFT FL
SCALE =1'-0"
GARAGE HALLWAY
(Exiting) LOFT SECTION B
ELECTRICAL LEGEND:
sp Smoke Detector
(Wire —In W/Barrery Back —Up)
o Smoke + Carbon Detector
SCD (Wire —In W/Barrery Back —Up)
5o cFM Exhaust Fan
(Vent to Exterior)
o Recessed 7W LED Light Fixture
Ceiling Mounted Light Fixture
Wall Mounted Light Fixture
$ Switch
$3 3—Way Switch
110V Wall Outlet
220V Wall Outlet
a Cable/Internet & CAT 6E
Telephone
o- Thermostat
Warm Air Supply
Warm Air Supply (ToeKick)
�F Whole House Ventilation
(Vent to Exterior)
ROOFING
CONT. GUTTER & DOWNSPOUT
REAR - EXTERIOR WALL
OOR PLAN
O
NORTH
ROOF GIRDER SEE CALCS. PACKAGE FOR SIZE
(Ex) (2) 2x10 PSL $1IA.0" LAG SCREW AT 24"
14NePR.I}JAK8 — (Ex) 2x CEILING JOIST w/HANGER
AT EACH JOIST
Option 1- SECTION A
SCALE 3/4"-1'-0"
ROOF GIRDER SEE CALCS. PACKAGE FOR SIZE
OGO
O
O
Ln
0
0
0
kD
Ln
0�-
EXISTING WALL TO BE
GARAGE ACCESS
DEMOLISHED
(GARAGE CONCRETE FLOOR AND
EXISTING FIREPLACE &
STAIR LANDING ARE FLUSH)
CHIMNEY WERE REMOVED
Of-
I I
104,00"
202,25"
-
6,50"
Ln
BEDRM 20
KITCHEN
`0
Ln
Ln
00
�
\
\o °
REF
\ u
373,00"
27
w
4F,
LL
o
264,5
w o
0
-
no
Q CO
m
Ln
of
UN -HEATED GARAGE
WINDOW UNDER STAIR
LIVING
CD
Ln
GARAGE
cU
146,25"
221,75"
158,00"
BEDRM 1
31'-1"
CW
COVERED PORCH AT
MAIN ENTRANCE
(Exiting) MAIN FLOOR PLAN
SCALE 4" = 1'-0"
TO FASTEN LVL BEAMS USE (3) ROWS 0
SIMPSON TIES H6 AT EACH END 2" DIA. AT 24" STAGGER EVERY 8"
ALL EXHAUSTS REQUIRED OUTLINE LOFT'S WALL (ABOVE) /
EG
104,00"
BEDRM 2 -
CD
Ln
cv
SD i
14 6.25"
BEDRM 1
!.
(Ex) 2x CEILING JOIST w/HANGER
Option 2 - SECTION
SCALE 3/4"-1'-0" ±-40" GUARDRAIL POSTS
See Detail Sect G
SD
SCD
01
WHF
VENT TO OUTSIDE
7
0 0
o
2.25`,-D 15.50" Ln
XF— '�KI H N `D Ln
co
o REF ipgw
� 31'-1" 9
� —
(4) 1.75"x20" LVL 2.0E
p� 1
cU
264,50"
LIVING
221,75"
CW
n
1�01111■
I m
0
Ln
GARAGE �
Ri
158,00"
COVERED PORCH AT
MAIN ENTRANCE MAIN FLOOR
± 40" GUARDRAIL SCALE 4" =1'-0"
0
NORTH
FIRE -RATED OR SOLID -CORE AND
EQUIPPED WITH A SELF -CLOSING
DEVICE
SCD
PLAN O
N CRTr-
03-16-20 REV 0
02-18-20 REV 1Q
NT Engineers 17614 NE 29th St - Redmond WA 98052 —*— housedesign4u@outlook.com 425-891-5111
PK.NG
45867 W�
4�GISTE
L
02 12 20
Phaysith's Interior Remodel DATE
2
9327 217th St SW 2020
Edmonds WA 98020-3943 SHEEP
PLAN VIEW 2
74%.16"
4' AJV
4' AJt
ELECTRICAL LEGEND:
sp Smoke Detector
(Wire —In W/Barrery Back —Up)
o Smoke + Carbon Detector
sco (Wire —In W/Barrery Back —Up)
50 6F Exhaust Fan
(Vent to Exterior)
CO) Recessed 7W LED Light Fixture
¢ Ceiling Mounted Light Fixture
Wall Mounted Light Fixture
$ Switch
$3 3—Way Switch
110V Wall Outlet
220V Wall Outlet
a Cable/Internet & CAT 6E
Telephone
o- Thermostat
Warm Air Supply
Warm Air Supply (ToeKick)
Whole House Ventilation
wHF (Vent to Exterior)
94%16'
11
0
0
0,11
co
(LJ
E d e e 1 ALL EXHAUSTS REQUIRED
1 e VENT TO OUTSIDE FURR-OUT WALL
See Sect. E
e EG U
a
e d e a d e a d
° e d° e ° e ° d a
5D CFNI
o
0
Ln
° 0, / 125.00"
o
SNACK
BAR
SD p 0
SCD
MASTER BDRM 30 °�° �;' 0
HP
e
° °
.� 8
2 e
0
STORAGE °
W.I.
160,00" 102.5 0 136,0 "
d ° •
e d
N ° d ° < ° e
L
°
1
XX
N e
A
e a
° e e a
Al-
� s
E
1
BASEMENT PLAN
SCALE 4" = V-0"
NORTH
CFM
' 1' 11
■!
e A\
See page 4 WSEC
notes for the Hot
A water tank efficiency
MAKE UP
REQUIRED AS PER
SECTION G2439.5
2015 I RC
SECTION 504.6 2015
IMC
M0
03-16-20 REV 0
02-18-20 REV 10
NT Engineers —*— 17614 NE 29th St - Redmond WA 98052 —*— housedesign4u@outlook.com 425-891-5111
02/12/20
Phaysith's Interior Remodel DATE
2
9327 217th St SW 2020
Edmonds WA 98020-3943 SHEEP
PLAN VIEW 3
C4 XJb
24 XJb
Window, Skylight and Door Schedule
Project Information
Phaysith's Interior Remodel
9327 217th St SW
Edmonds WA 98020-3943
Ref. U-factor
Exempt Swinging Door (24 sq. ft. max.)
Exempt Glazed Fenestration (15 sq. ft. max.)
Vertical Fenestration (Windows and doors)
Component
Description Ref. U-factor
Living
0.27
Foyer
0.27
Bedrm 1
0.27
Bedrm 2
0.27
Kitchen
0.27
Hallway
0.27
Loft
0.27
Master Ed
0.27
Master Ed
0.27
Overhead Glazing (Skylights)
Component
Contact Information
Ken Nguyen
17614 NE 29th St
Redmond WA 98052
Width Height
Ot. Feet Inch Feet Inch
Width Height
Ot. Feet Inch Feet Inch
■■O■E
■■■ME
=MEMO
■■■■■
■■■■■
Sum of Vertical Fenestration Area and UA
Vertical Fenestration Area Weighted U = UA/Area
Width Height
Ot. Feet Inch Feet inch
Sum of Overhead Glazing Area and UA
Overhead Glazing Area Weighted U = UA/Area
Total Sum of Fenestration Area and UA (for heating system sizing calculations)
Area UA
11
111
1 1
III
Area UA
11
AI
'11
I:I
11�
A1�
1 1
AI
11
111
1 1
III
1 1
III
11
111
1 1
III
1 1
III
11
111
11
111
1i
1II
11
111
11
111
1 1
III
11
111
11
111
1 1
III
11
111
11
111
11
111
1 1
III
11
111
1 1
III
1 1
III
11
111
11
111
1 1
III
11
111
1 1
III
1 1
III
11
111
11
111
1 1
III
11
111
1 1
III
218.81 59.06
0.27
Area HA
1 1
III
1 1
III
1 1
ill
1/
1II
11
111
1 1
III
1 1 III
1 III
218.81 59.06
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Project Information Contact Intormation
Phaysith's Interior Remodel Ken Nguyen
9327 217th St SW 17614 NE 29th St
Edmonds WA 98020-3943 Redmond WA 98052
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed. In addition, based on the size of the structure, the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative
All Climate Zones
R-Values
U-Factors
Fenestration U-Factor'
n/a
0.30
Skylight U-Factor
n/a
0.50
Glazed Fenestration SHGe'
n/a
r1a
Ceilingk
49'
0.026
Wood Frame Wall""
21 int
0.056
Mass Wall R-Value'
21/21h
0.056
Floor
301
0.029
Below Grade Wall` m
10/15/21 int + TB
0.042
Slab° R-Value & Depth
1 10, 2 ft
r1a
I aoie K402.1.1 ana I able K41J2.1.3 footnotes incwaea on rage 2.
Date
Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to
achieve the following minimum number of credits:
1. Small Dwelling Unit: 1.5 credits
❑ Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of
fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but
less than 1500 square feet.
p 2. Medium Dwelling Unit: 3.5 credits
All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall
require 2.5 credits.
❑ 3. Large Dwelling Unit: 4.5 credits
Dwelling units exceeding 5000 square feet of conditioned floor area.
❑ 4. Additions less than 500 square feet: .5 credits
Table R406.2 Summary
Ontion Descriution
Credit(sl
1a
Efficient Building Envelope I
0.5
1b
Efficient Building Envelope 1b
1.0
1c
Efficient Building Envelope 1c
2.0
ld
Efficient Building Envelope ld
0.5
2a
Air Leakage Control and Efficient Ventilation 2a
0.5
2b
Air Leakage Control and Efficient Ventilation 2b
1.0
2c
Air Leakage Control and Efficient Ventilation 2c
1.5
3a
High Efficiency HVAC 3a
1.0
3b
High Efficiency HVAC 3b
1.0
3c
High Efficiency HVAC 3c
1.5
3d
High Efficiency HVAC 3d
1.0
4
High Efficiency HVAC Distribution System
1.0
5a
Efficient Water Heating 5a
0.5
5b
Efficient Water Heating 5b
1.0
5c TEfficient
Water Heating 5c
1.5
5d
JEfficiert Water Heating 5d
0.5
6
lRenewable Electric Energy
0.5
Total Credits
*Please refer to Table R406.2 for complete option descriptions
O 0.5
El
0
1200 kwh
1.5
0.0
3.50
For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing.
a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is
less than the label or design thickness of the insulation, the compressed R-value of the insulation from
Appendix Table A101.4 shall not be less than the R-value specified in the table.
b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration.
"10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous
insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the
basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13
cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or
exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-
13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and
basement wall.
d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1.
e There are no SHGC requirements in the Marine Zone.
f Reserved.
g Reserved.
h Reserved.
The second R-value applies when more than half the insulation is on the interior of the mass wall.
'Reserved.
k
For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38.
(Reserved.
' Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a
minimum of R-10 insulation.
a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as
specified in Section R402.1.3.
EFFICIENT BUILDING ENVELOPE I a:
Prescriptive compliance 15 based on Table R402. 1 .1 with the
following modifications:
Vertical fenestration U = 0.28
Floor R-38
51ab on grade K- 10 perimeter and under entire slab
Below grade 51ab R- 10 perimeter and under entire 51ab 1
AIR LEAKAGE CONTROL AND EI=I=ICIENT VENTILATION 2a:
Compliance based on R402.4. 1 .2: Reduce the tested air
leakage to 3.0 air changes per hour maximum
and
All whole house ventilation requirements a5 determined by
Section M 1507.3 of the International Residential Code shall
be met with a high efficiency fan (maximum 0.35 watts/cfm),
not interlocked with the furnace fan. Ventilation systems using
a furnace including an ECM motor are allowed, provided that
they are controlled to operate at low speed in ventilation only
mode.
To qualify to claim this credit, the building permit drawings
shall specify the option being selected and shall 5peclfy the
maximum tested building air leakage and Shall show the
qualifying ventilation system.
NIGH EFFICIENCY HVAC EQUIPMENT 3d:
Al Ductless 5plit System Heat Pumps, Zonal Control: In homes
where the primary space heating system 15 zonal electric
heating, a ductless heat pump system shall be installed
and provide heating to the largest zone of the housing unit.
To qualify to claim this credit, the building permit drawings shall
Specify the option being selected and shall specify the heating
equipment type and the minimum equipment efficiency.
EEEICIENT WATER HEATING 5c:
Water heating system shall include one of the following:
Gas, propane or oil water heater with a minimum Ef= of 0.9 1
or
Solar water heating Supplementing a minimum standard water
heater. Solar water heating will provide a rated minimum savings
of 85 therms or 2000 kWh based on the Solar Rating and
Certification Corporation (5RCC) Annual Performance of G-300
Certified 5olar Water Heating Systems
or
Electric heat pump water heater with a minimum EF of 2.0 and
meeting the standards of NEEA15 Northern Climate pecification5
for Heat Pump Water Heaters
To qualify to claim this credit, the building permit drawings shall
5peclfy the option being selected and shall specify the water
heater equipment type and the minimum equipment efficiency
and, for solar water heating systems, the calculation of the
minimum energy savings.
VENTILATION RATES FOR GROUP R E IVATE DWELLING
0
FLOOR AREA
(SQ.FT)
BE OM
0-1
2-3
4-5
6-7
>7
<
30
45
60
75
90
1501-3000 Ar
45
60
75
90
105
_010 - 00
60
75
90
105
120
4501-6000
75
90
105
120
135
6001-7500
90
105
120
135
150
> 7501
105
120
135
150
165
VENTILATION RATES IN TABLE ARE MINIUM OUTDOOR AIRFLOW
RATES MEASURED IN CFM.
- WHOLE HOUSE VINTILATION SYSTEM IS REQUIRED AND SHALL CONFORMT TO
WAC 51-52-0403.8.6 WHOLE HOUSE VENTILATION WITH EXHAUST FAN SYSTEM
- FRESH AIR SHALL DRAWN IN THROUGH A MIN. OF ONE OPERABLE WINDOW IN
EACH HAVITABLE SPACE.
- FOR ALL DWELLINGS UP TO 5000 SQ FT, 3.5 CREDIT ARE REQUIRED FROM TABLE
406.2 SEE "METHOD OF OBTAINING ENERSY CREDITS" ON SHEET 13.
- HEATING DUCT ARE NOT ALLOWED TO DISPLACE REQUIRED INSULATION WITH
THE EXTERIOR WALLS, FLOOR, AND CEILING.
- DUCTS SHALL BE LEAKED TESTED IN ACCORDANCE WITH RS-33, USING THE MAX.
DUCT LEAKAED TESTED IN ACCORDANCE WITH RS-33, USING THE MAX. DUCT
LEAKAGE RATE SPECIFIED IN SECTION R403.2.2 .
ENERGY CODE COMPLIANCE CHART WITH 3' OF ELECTRICAL PANEL.
A MINIMUM OF 75% OF ALL LIGHTING MUST BE HIGH EFFICIENCY.
WHOLE HOU5E VENTILATION
EACH DWELLING UNIT SHALL DE EQUIPPED WITH A VENTILATION
SYSTEM COMPLYING WITH SECTION M 1507.3.4, M 1507.3.5,
PROVIDE A MINIMUM GO CFM, CONTINUOUSLY OPERATING
SYSTEM FOR A DWELLING UNIT CONSISTS OF 2 TO 3
BEDROOMS AND LE55 THAN 3,000 51. THE FAN 15 TO 5E
o E
MAXIMUM WHF N015E 15 TO DE A MAXIMUM OF 1.0 5ONE.
BEDROOM DOOR SHALL DE UNDERCUT TO A MINIMUM OFY2°
ABOVE THE SURFACE OF THE FINISH FLOOR COVERING.
PROVIDE NOT LE55 THAN 4 SQUARE INCHES OF NET FREE AREA
OF OPENING, SCREENED WITH DAMPER CONTROL FOR EACH
BEDROOM.
A WRITTEN REPORT OF THE AIR LEAKAGE TEST RESULTS, SHALL
BE 51GNED 5Y THE TESTING PARTY AND PROVIDED TO THE
BUILDING INSPECTOR, PRIOR TO CALL FOR FINAL INSPECTION.
NOTE: IF A WINDOW IN EACH HABITABLE ROOM 15 EQUIPPED
WITH A 4 SQUARE INCH MIN. FRESH AIR PORT, THEN
THKU-WALL INLETS A5 SHOWN ON PLANS WILL NOT DE
REQUIRED.
OUTDOOR AIR INLETS SHALL 13E LOCATED 50 A5 NOT TAKE AIR
FROM THE FOLLOWING AREAS:
I. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT
OUTLET, UNLE55 SUCH VENT OUTLET 15 3 FEET ABOVE THE
OUTDOOR AIR INLET.
2. WHERE IT WILL PICK UP OBJECTIONABLE ODORS,
FUMES OR FLAMMABLE VAPORS.
3. A HAZARDOUS OR UNSANITARY LOCATION.
4. A ROOM OR SPACE HAVING ANY FUEL -BURNING
APPLIANCE THEREIN.
5. CL05EK THAN 10 FEET5 FROM A VENT OPENING OR
PLUMBING DRAINAGE SYSTEM UNLE55 THE VENT OPENING 15 AT
LEAST 3 FEET ABOVE TH E Al K I N LET.
G. ATTIC, CRAWL SPACES OR GARAGES.
FENE5TKATION OF PRODUCT RATING
NFRC 100, labeled and certified by the manufacturer
02/12/20
)A"_70
03-16-20 REV 0
02-18-20 REV Al
NT Enaineers 17614 NE 29th St - Redmond WA 98052 housedesian4uCa?outlook.com 425-891-5111
Phaysith's Interior Remodel
9327 217th St SW
Edmonds WA 98020-3943
DETAIL SECTIONS
DATE
2-12
2020
SHEEP I
4 21