BLD2021-0668+Manufacturer_Specifications_and_Installation_Instructions+5.13.2021_2.15.13_PM+2195728LG370N1 K-A 9 370W The LG NeON° 2 is LG's best selling solar module and one of the most powerful and versatile modules on the market today. The cells are designed to appear all lack at a distance, and the performance warranty guarantees 90. Yo of labeled power output at 25 years. C UL US Features Enhanced Performance Warranty zsn LG NeON° 2 Black has an enhanced performance warranty. After 25 years, LG N§ON° 2 Black is guaranteed at least 90. / of initial performance. 25-Year Limited Product Warranty 25yrs The NeON° 2 Black is covered by a 25-year limited product warranty. In addition, up to $450 of labor costs will be covered in the rare case that a module needs to be repaired or replaced. Solid Performance on Hot Days + Roof Aesthetics i ++ L® LG NeON° 2 Black performs well on hot LG NeON° 2 Black has been designed with days due to its low temperature coefficient. aesthetics in mind using thinner wires that appear all black at a distance. When you go solar, ask for the brand you can trust: LG Solar About LG Electronics USA, Inc. �� LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy storage systems. The company first embarked on a solar energy source research program in 1985, supported by LG Group's vast experience in the semi -conductor, LCD, chemistry and materials industries. In 2010, LG Solar successfully — released its first MonoX® series T the market, which is now available in 32 countries. The NeON® (previous MonoX® NeON), NeON82, NeON®2 BiFacial won the 'lntersolar AWARD" in 2013, 2015 and 201 , which demonstrates LG's leadership and innovation in the solar industry. Llfe's Good LG NeON°2 Black LG370N1 K-A General Data Cell Properties (Material/Type) Monocrystalline/N-type Cell Maker LG Cell Configuration Cells ( x 10) Number of Busbars 12EA Module Dimensions (L x W x H) 1,740mm x 1,042mm x 40 mm Weight 18. Ig Glass (Material) Tempered Glass with AR coating Backsheet(Color) Black Frame (Material) Anodized Aluminium Junction Box (Protection Degree) IP with 3 Bypass Diodes Cables (Length) 1,100mm x 2EA Connector (Type/Maker) MC 4/MC Certifications and Warrantv Certifications* IEC 215gq1/-1-1/2:201 IE 730-1/2:201 , UL 1730-1:2017, UL 730-2:2017 ISO 9001, ISO 14001, ISO 50001 OHSAS18001 Salt Mist Corrosion Test IEC 701:2012 Severity Ammonia Corrosion Test IEC 71 : 013 Module Fire Performance Type 2 (UL 730) Fire Rating Class C (UL 790, ULC/ORD C 1703) Solar Module Product Warranty 25 Year Limited Solar Module Output Warranty Linear Warranty* *Improved: 1"year 98.5%, from 2-24th year: -0.33%/year down, 90. %at year 25 Temperature Characteristics NMOT* IT] 42 ± 3 Pmax [Y.PC] -0.35 Voc [Y.PC] -0.2 Isc [Yorc] 0.03 *NMOT (Nominal Module Operating Temperature): Irradiance 800 W/m', Ambient temperature 20°C, Wind speed 1 m/s, Spectrum AM 1.5 Flprtriral Prnnerties (NMOT) Model LG370N 1 K-A Maximum Power (Pmax) [W] 277 MPP Voltage (Vmpp) [V] 33.3 MPP Current (Impp) [A] 8.32 Open Circuit Voltage (Voc) [V] 39A Short Circuit Current (Isc) [A] 8.81 IN Curves 12.0 1000W 10.0 800W 8.0 600W 6.0 40OW 4.0 20OW 2.0 0.0 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 voltage [N] Electrical Properties (STC*) Model LG370N1 K-A Maximum Power (Pmax) [W] 370 MPP Voltage (Vmpp) [V] 35.5 MPP Current (Impp) [A] 10.43 Open Circuit Voltage (Voc t 5%) IV] 41.9 Short Circuit Current (Isc t 5%) [A] 10.9 Module Efficiency [%] 20.4 Power Tolerance [%] 0­3 *STC (Standard Test Condition): Irradiance 1000 Won', cell temperature 25°C, AM 1.5 Measurement Tolerence of Pmax:t 3% ODeratina Conditions Operating Temperature IT] -40 -+85 Maximum System Voltage IV] 1,000 (UL/IEC) Maximum Series Fuse Rating [A] 20 Mechanical Test Load* (Front) [Pa/psf] 5,400 Mechanical Test Load* (Rear) [Pa/psf] 4,000 *Based on IEC 1215-2 , 01 JTest Load - Design Load Safety Factor (1.5)) Mechanical Test Loads OOPa/5,40OPa based on IEC 215:2005 Packaging Configuration Number of Modules per Pallet [EA] 25 Number of Modules per 40' Container [EA] 0 Number of Modules per 53' Container [EA] 850 Packaging Box Dimensions (L x W x H) [mm] 1,790 x 1,120 x 1,213 Packaging Box Dimensions (L x W x H) [in] 70.5 x 44.1 x 47.8 Packaging Box Gross Weight [kg] 500 Packaging Box Gross Weight [lb] 1,102 Dimensions (mm/inch) 1002.0 / 39.4 (Distance between Grounding & Mounting Holes) 175.0/6.9 i6-8.0 x3.0/0.3 x 0.1 Drain 8-04.3 Junction Box Groundin E 8- 8.5 x 12.0 Mounting Holes 1100 / 43.3 Cable Length x - x in 9 5 LG Electronics USA, Inc. Product specifi?tions are subject to change without notice. Solar Business Division LG37CN1 K-A .pdf L 2000 Millbrook @riv@a 020221 Lincolnshire, IL (j0 9 Life s Good www.lg-solarcom © 2021 LG Electronics USA, Inc. All rights reserved. 40.0 / 1.55 Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US ® solar -..= •000 ® solar- d G f O • a a 0 E9 � Optimized installation with HD -Wave technology / Specifically designed to work with / Extremely small power optimizers / Record -breaking efficiency / Built-in module -level monitoring / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for / Optional: Revenue grade data, ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5% accuracy) / UL1741 SA certified, for CPUC Rule 21 grid compliance solaredge.com solar=@@ Single Phase Inverter Wit HID -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211 - 240 - 264) AC Output Voltage Min.-Nom.-Max. - ✓ ✓ - ✓ Vac (183 - 208 - 229) AC Frequency (Nominal) 59.3 - 60 - 60.50) Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output - 16 - 24 - - 48.5 A Current @208V GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Yes Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 7750 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(1) 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(I) - 9 - 13.5 - - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600kn Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency gg 99 @ 240V 98.5 @ 208V Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(') Rapid Shutdown - NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG 3/4' minimum / 14-6 AWG 3/4" minimum /14-4 AWG Range DC Input Conduit Size / # of Strings / AWG Range 3/4" minimum / 1-2 strings / 14-6 AWG 3/4" minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / (HxWxD) mm Weight with Safety Switch 22110 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -25 to +600(-40`F / -40'C option)(') "F / °C Protection Rating NEMA 4X (Inverter with Safety Switch) 0) For other regional settings please contact SolarEdge support m A higher current source may be used; the inverter will limit its input current to the values stated (11 Revenue grade inverter P/N: SExxxxH-US000NNC2 (4) For power de -rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf "1 -40 version P/N: SExxxxH-US000NNU4 O SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/201MOVENG NAM. Subject to change without notice. Ril Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 0 MO IN m PV power optimization at the module -level / Specifically designed to work with SolarEdge inverters / Up to 25% more energy / Superior efficiency (99.5%) / Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading / Flexible system design for maximum space utilization / Fast installation with a single bolt / Next generation maintenance with module - level monitoring / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) / Module -level voltage shutdown for installer and firefighter safety solaredge.com solar -•• Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 INPUT Rated Input DC PowerM 320 340 370 400 405 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 60 1250 83(2) Vdc MPPT Operating Range 8 - 48 8-60 8 - 80 8-60 12.5 -105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 11.75 11 14 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category 1II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1 ± 0.1 Vdc Optimizer STANDARD COMPLIANCE EMC FCC Part15 Class 3, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0 , UV Resistant ROHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 129 x 153 x 27.5 / 5.1 x 6 x 1.1 129x153x33.5 /5.1x6x1.3 129x153x29.5 /5.1x6x1.16 129x159x49.5/5.1x6.3x1.9 129x162x59/ 5.1x6.4x2.3 mm /in Weight (including cables) 630 / 1.4 750 / 1.7 655 / 1.5 845 / 1.9 1064 / 2.3 gr / lb Input Connector p MC431 Single or dual MC43x4) MC40) Input Wire Length 0.16 / 0.52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0.9 / 2.95 1.2 / 3.9 m / ft Operating Temperature Range(') -40 - +85 / -40 - +185 -C / `F Protection Rating IP68 / NEMA6P Relative Humidity 0 -100 % (1) Rated power of the module at STC will not exceed the optimizer "Rated Input DC Power". Modules with up to +5% power tolerance are allowed (2) NEC 2017 requires max input voltage be not more than 80V (3) For other connector types please contact SolarEdge (4) For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals. (5) For ambient temperature above +85°C / +185°F power de -rating is applied. Refer to Power Optimizers Temperature De -Rating Technical Note for more details. Minimum String Length P320, P340, P370, 8 10 18 (Power Optimizers) P400, P401 P405, P485, P505 6 8 14 Maximum String Length (Power Optimizers) 25 25 5018I 5700 (6000 with Maximum Power per String SE7600-US - SE11400- 5250 60000) 1275001) W US) Parallel Strings of Different Lengths or Orientations Yes (6) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string-sizing-na.pdf (7) It is not allowed to mix P405/P485/P505 with P320/P340/P370/P400/P401 in one string (8) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (9) For 208V grid: it is allowed to install up to 7,200W per string when the maximum power difference between each string is 1,000W (10) For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W V SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. T Ito�Us Ro H S Al ,ot�ertrademarks mentioned herein are trademarks oftheir respective owners. Date: 07/2020/VO2/ENG NAM. Subject to change without notice.CC_ Intertek I RON RI DGE Class A Fire Rating Background All roofing products are tested and classified for their ability to resist fire. Recently, these fire resistance standards were expanded to include solar equipment as part of the roof system. Specifically, this requires the modules, mounting hardware and roof covering to be tested together as a system to ensure they achieve the same fire rating as the original roof covering. These new requirements are being adopted throughout the country in 2016. IronRidge Certification IronRidge was the first company to receive a Class A Fire Rating —the highest possible rating —from Intertek Group plc., a Nationally Recognized Testing Laboratory. IronRidge Flush Mount and Tilt Mount Systems were tested on sloped and flat roofs in accordance with the new UL 1703 & UL 2703 test standards. The testing evaluated the system's ability to resist flame spread, burning material and structural damage to the roof. Refer to the table below to determine the requirements for achieving a Class A Fire Rating on your next project. Flush hMMount LJ_J_J Tilt Mount Any Slope Test Setup Solar Modules Solar modules are given a Type classification based on their materials and construction. Mounting System Mounting is tested as part of a system that includes type -tested modules and fire -rated roof covering Roof Covering Roof covering products are given a Fire Class Rating of A, B or C based on their tested fire resistance. Burning Brand Test 10,00 A burning wooden block is placed on module as a fan blows at 12 mph. Flame cannot be seen on underside of roof within 90 minutes. Spread of Flame Test Flame at southern edge of roof is aimed up the roof as a fan blows at 12 mph. The flame cannot spread 6 feet or more in 10 minutes. Type 1, 2, & 3 <_ 6 Degrees I Type 1, 2, & 3 Class A Class A 'Class A rated PV systems can be installed on Class A, B, and C roofs. Frequently Asked Questions What is a "module type"? The new UL1703 standard introduces the concept of a PV module type, based on 4 construction parameters and 2 fire performance parameters. The purpose of this classification is to certify mounting systems without needing to test it with every module. What roofing materials are covered? All fire rated roofing materials are covered within this certification including composition shingle, clay and cement tile, metal, and membrane roofs. What if I have a Class C roof, but the jurisdiction now requires Class A or B? Generally, older roofs will typically be "grandfathered in", and will not require re -roofing. However, if 50% or more of the roofing material is replaced for the solar installation the code requirement will be enforced. Where is the new fire rating requirement code listed? 2012 IBC: 1509.7.2 Fire classification. Rooftop mounted photovoltaic systems shall have the same fire classification as the roof assembly required by Section 1505. Where is a Class A Fire Rating required? The general requirement for roofing systems in the IBC refers to a Class C fire rating. Class A or B is required for areas such as Wildland Urban Interface areas (WUI) and for very high fire severity areas. Many of these areas are found throughout the western United States. California has the most Class A and B roof fire rating requirements, due to wild fire concerns. Are standard mid clamps covered? Mid clamps and end clamps are considered part of the PV "system", and are covered in the certification. More Resources Installation Manuals Visit our website for manuals that include UL 2703 Listing and Fire Rating Classification. Gcl — .. _....�uyt.uuii. What attachments and flashings are deemed compatible with Class A? Attachments and their respective flashings are not constituents of the rating at this time. All code -compliant flashing methods are acceptable from a fire rating standpoint. What mounting height is acceptable? UL fire testing was performed with a gap of 5", which is considered worst case in the standard. Therefore, the rating is applicable to any module to roof gap. Am I required to install skirting to meet the fire code? No, IronRidge achieved a Class Afire rating without any additional racking components. What determines Fire Classification? Fire Classification refers to a fire -resistance rating system for roof covering materials based on their ability to withstand fire exposure. Class A - effective against severe fire exposure Class B - effective against moderate fire exposure Class C - effective against light fire exposure What if the roof covering is not Class A rated? The IronRidge Class A rating will not diminish the fire rating of the roof, whether Class A, B, or C. What tilts is the tilt mount system fire rated for? The tilt mount system is rated for 1 degrees and up and any roof to module gap, or mounting height. Engineering Certification Letters We offer complete engineering resources and pre -stamped certification letters. I RON RI DGE FlashFoot2 The Strongest Attachment in Solar IronRidge FlashFoot2 raises the bar in solar roof protection. The unique water seal design is both elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist -on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. Twist -On Cap FlashFoot2's unique Cap design encapsulates the lag bolt and locks into place with a simple twist. The Cap helps FlashFoot2 deliver superior structural strength, by aligning the rail and lag bolt in a concentric load path. a Single Socket Size A custom -design lag bolt allows you to install FlashFoot2 with the same 7/16" socket size used on other Flush Mount System components. / Three -Tier Water Seal FlashFoot2's seal architecture utilizes three layers of protection. An elevated platform diverts water away, while a stack of rugged components raises the seal an entire inch. The seal is then fully-encapuslated by the Cap. FlashFoot2 is the first solar attachment to pass the TAS-100 Wind -Driven Rain Test. M Water -Shedding Design An elevated platform diverts water away from the water seal. Installation Features ElAlignment Markers Quickly align the flashing with chalk lines to find pilot holes. URounded Corners Makes it easier to handle and insert under the roof shingles. 0 Reinforcement Ribs Help to stiffen the flashing and prevent any bending or crinkling during installation. Benefits of Concentric Loading 1200 FlashFoot2 1000 Traditional solar attachments have a horizontal offset between the rail and lag 800 Flash Foot :v> •Leading Competitor bolt, which introduces leverage on the lag ro 600 bolt and decreases uplift capacity. 400 FlashFoot2 is the only product to align the 200 rail and lag bolt. This concentric loading design results in a stronger attachment for o 1 2 the system. Rail -to -Lag Offset (in) Testing & Certification Structural Certification Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7. • Low -Cost Competitor Water Seal Ratings Water Sealing Tested to UL 441 Section 27 "Rain Test" and TAS 100-95 "Wind Driven Rain Test" by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. 3 // I RON RI DGE XR Rail Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs XR Rails are IronRidge offers compatible with a range of tilt leg OFlashFoot and �� options for flat other pitched roof ■�■ roof mounting attachments. applications. Corrosion -Resistant Materials All XR Rails are made of marine -grade aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. i XR10 XR10 is a sleek, low -profile mounting rail, perfectly matched to regions without snow. It achieves 6 foot spans, while also staying light and economical 6' spanning capability Moderate load capability Clear anodized finish Internal splices available Rail Selection ■ XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans. 8' spanning capability Heavy load capability Clear & black anodized finish Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans 12 feet or more for commercial applications. 12'spanning capability Extreme load capability • Clear anodized finish • Internal splices available The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. 100 120 None 140 XR10 160 100 120 10-20 140 160 100 120 30-40 140 160 50-70 160 160 80-90 1m�& Rail Span 89 XR1000 0 2014 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0 f&,� I RON RI DGE UFO Family of Components Simplified Grounding for Every Application The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails. All system types that feature the UFO family —Flush Mount, Tilt Mount and Ground Mount —are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both t module and the rail, resulting in many parallel groundinc paths throughout the system. This leads to safer and me reliable installations. Stopper Sleeve The Stopper Sleeve snaps onto the UFO, converting it into a bonded end clamp. e.; Splice sear-anuing screws ro ror a secure connection. No bonding strap needed. / Grounding Lug ® �� ingle Grounding Lug connects an entire row of PV modules to the grounding conductor. Universal Fastening Object (UFO) The UFO securely bonds solar modules to XR Rails. It comes assembled and lubricated, and can fit a wide range of module heights. Bonded Attachments The bonding bolt attaches and bonds the L-foot to the rail. It is installed with the same socket as the rest of the system. I RON RI DGE Flush Mount System Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior ® Pre -stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance ® Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty ® Entire system and components meet �� Twice the protection offered by newest effective UL 2703 standard. competitors. System Diagram ---------------- ----------- 41 ---------------- --- ------------------- -------- 8 -------- --- -------- OUFO C Stopper Sleeve • Grounding Lug Bonded Splice Ground Wire 4 Approved Enphase microinverters can provide equipment grounding of IronRidge systems, eliminating the need for grounding lugs and field installed equipment ground conductors (EGC). A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL Certification The IronRidge Flush Mount, Tilt Mount, and Ground Mount Systems have been listed to UL 2703 by Intertek Group plc. UL 2703 is the standard for evaluating solar mounting systems. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. 0 Go to IronRidge.com/UFO XR Rails UFO/Stopper I d Bonded Splice L V Grounding Lugs 1 per Row XR1000 Only N/A 1 per Row 1 per Array Microinverters Enphase - M250-72, M250-60, M215-60, C250-72 & Power Darfon - MIG240, MIG300, G320, G640 Optimizers SolarEdge - P300, P320, P400, P405, P600, P700, P730 Fire Rating Class A Class A N/A Modules Tested or Evaluated with over 400 Framed Modules Refer to installation manuals for a detailed list. XR Rails O XR10 Rail i A low -profile mounting rail for regions with light snow. • 6' spanning capability • Moderate load capability • Clear & black anod. finish XR100 Rail The ultimate residential solar mounting rail. • 8' spanning capability • Heavy load capability • Clear & black anod. finish Clamps & Grounding O — UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear & black finish Attachments O FlashFoot2 Flash and mount XR Rails with superior waterproofing. • Twist -on Cap eases install • Wind -driven rain tested • Mill & black finish Resources Stopper Sleeves _L Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • 6 different sizes • Clear & black anod. finish Slotted L-Feet XR1000 Rail Bonded Splices A heavyweight mounting All rails use internal splices rail for commercial projects. for seamless connections. • 12' spanning capability • Extreme load capability • Clear anodized finish Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Bonding Hardware Wi� Drop -in design for rapid rail Bond and attach XR Rails attachment. to certified attachments. Secure rail connections Slot for vertical adjusting Clear & black anod. finish esign Assistant -- o from rough layout to fully - ngineered system. For free. o to IronRidge.com/design • T & Square Bolt options • Nut uses 7/16" socket • Assembled & lubricated • Self -drilling screws • Varying versions for rails • Forms secure bonding Microinverter Kits Mount Mls or POs to XR Rails. • Bonds devices to rails • Kit comes assembled • Listed to UL 2703 Flush Standoffs Raise Flush Mount System to various heights. • Works with vent flashing • 4" and 7" lengths • Ships assembled NABCEP Certified Training 0�GSR �o`b� NABCEP Earn free continuing education credits, while learning more about our systems. Go to Iron Ridge.com/training 0 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.20