Loading...
BLD2021-0668+Specifications+5.13.2021_2.15.22_PM+2195732Required Setbacks from Ridge: 18.1 Maximum Mount Spacing: 72" "All Roof Type: Comp Roof Slope: 230 B" Array Tilt : Flush Array Azimuth(s): 90°,180°,270°, Roof Area: 4955 ft2 Array Area 742 ft2 Array to Roof Coverage 15% * * *Roof Attachments/ Fastners: see pg. G5 Equip. BOM * Module and Rail Selection Guide LG-370C11C-V5 40 x 66.9 Clamp Zone "A" 0-4.7" Clamp Zone "B" 7.9-15.7" Mods per Row Rail typel+ rail type2 (8)Portrait, (1)row (2)14', (2)14' (6)Portrait, (2)rows (2)14', (2)split 14' (3)Portrait, (3)rows (2)14', (2)Portrait, (4)rows (2)split 14', (1)Landscape, (1)row (2)split 14', 4 'k A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OFA&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U a � M Lr) 0 d7� U)U)00 r�UQ V p ��00 vi O O�N-0 . O l0 0 N O O L �� E ao % 00w REVISIONS Rev. #: Date: 1 May 06, 2021 Designed by: Thomas N Project Manager: Nathan Bennett (805) 350-1823 Current Date:Mav 06, 2021 14%—L 1"I%—L%—I A2 Roof Layout -------------- --� String 1 + 14 modules String 2 14 modules String 3 <F:J 10 modules 0 Equipment Schedule 0 I I I C I w I z z 0 U - J U. Ref. Category Equipment QTY 1 Modules LG-370N1K-A6 38 2 Optimizers P370 SolarEdge Optimizer 38 3 Jbox Jbox 4 41 Inverters Solar Edge SE11400H 1 5 MeterBase MeterBase-125A 4 Jaw w/ 3.5" AWCAP 1 Meter Landis Gyr EA110000-OP29 240V 1 6 Disconnect 60A 240V 2 Pole I Heavy Duty, Fuse, Lockable 1 DisconnectFuse FLNR - 60 A Fuses for Disconnect (qty 1 /pole) 1 nitoring TE'lectricalWork SolarEdge Consumption Monitoring (2p2OA breaker) 1 EV Charger outlet (nema 14-50) 1 0 Conductor Schedule I Line O Load �-------� I Located less than 10' I from net meter and I less than 10' from tap I I �L--------- 5 Customer Owned Production Meter 0 IA I I i I I I, L---.4 #6 GEC 1 Neutral Bar w/ bonding jumper ■ = A & R Scope `,'I' _ I = Existing or A&RSOLAR Others Scope 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 — Supply Side Connection 705.11 (Existing) O Main Service Panel (1ph 240V Service) Main Breaker: 200A Bus Rating:200A Service entrance conductors 4/0 XHHW-2 (L1 & L2) 2/0 XHHW-2 (N) I nuerter Specs Watts W Output LAI AC Voltage #of Inverters OCPD Solar Edge SE11400H 11400 47.5 240 1 60 ****N/A**** 0 0 0 0 0 ****N/A**** 0 0 0 0 0 Module Specs Watts w Imp Vmp Voc Isc LG-370N 1K-A6 370 10.43 35.5 41.9 10.96 Temp. Adjusted 0 0 32.4 45.4 0 Summary Distance (ft) Current @125% Operating Voltage Voltage Drop Volt. Drop (total) A (2)#10 CU, (1)#6 EGC, PV Wire 60OV, AIR 50 18.75A 400V 0.40% 1.19% B (6)#10 CU, (1)#10 EGC, THWN-2, 0.75"EMT(min) 50 18.75A 400V 0.400o C (2)#6 CU, (1)#10 N, (1)#10 EGC, THWN-2, 0.75"EMT(min) 10 59.38A 240V 0.19% D (2)#6 CU, (1)#6 N, (1)#6 GEC, THWN-2, 1"PVC(min) 10 59.38A 240V 0.19% General Notes: Utility: Snohomish PUD 1. EGC Where exposed to physical damage will be #6AWG Bare CU 2. If installing conduit on the roof, maintain greater than 7/8" above the surface 3. NEC 690.12: Rapid Shutdown initiated by loss of Grid or AC Disconnect THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. a Ln > � O AM W Lr) 00 V �0TI Ln C^N-0 DON O L NO E ao O 00w REVISIONS Rev. #: Date: 1 May 07, 2021 Designed by: Thomas N Project Manager: Nathan Bennett (805) 350-1823 Current Date:Mav 07, 2021 E1 Single Line PV Electrical Calculations Inverter Specs Watts W Output AC - Voltage # of Inverters OCPD Total AC Comb. EGC AC LAI out.(A) OCPD Solar Edge SE11400H 11400 47.50 240 1 60 47.5 60 410 r Ampe ****N'A**** 0 0.00 0 0 0 ****NSA**** 0 0.00 0 0 0 Module Specs Wats IMP Vmp Voc Isc Temp. Coef V(oc) DC Volt LG-370N1K-A6 370 10.43 35.5 41.9 10.96 -0.26 #10 I Max V( Max , Temp. Adjusted 32.4 -r-1 45.4 Optimizer? P370 SolarEdge Optimizer Max current output: 15A, Max Voltage: 480V Equipment Solar Edge SE11400H ****N/A**** ****N/A**** Mppt Input 1 2 3 1 2 3 1 2 3 Module LG-370N1K-A6 ****SELECT**** ****SELECT**** # Modules per String 14 10 0 0 0 0 0 0 0 #Strings 2 1 0 0 0 0 0 0 0 # of Mods per group 28 10 0 0 0 0 0 0 0 # of Mods/inverter 38 0 0 # of Inverters 1 0 0 Total # of Modules 38 Ref. Conductor Description A (String) to Jbox B Jbox to Inverter C Inverter to Disconnect D Disco. to Interconnect E F G H Inverter 4ppt input -age (Imp) age (Vmp) iltage(DC) Imps (DC) Array Specs (Adiusted for Temperature) Solar Edge SE11400H ****N/A**** ****N/A**** 1 2 3 1 2 3 1 2 3 12.96 9.26 0.00 0.00 0.00 0.00 0.00 0.00 0.00 400.0 400.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 480.0 480.0 0.0 1 0.0 1 0.0 1 0.0 1 0.0 1 0.0 1 0.0 15.00 15.00 1 0.00 1 0.00 0.00 1 0.00 0.00 1 0.00 0.00 Max Array Power(STC): 14.06 kW DC Max Continuous AC Power: 11.4kW AC Interconnection Calcs Main Breaker 200 Bus Bar 200 Max PV OCD AI Iowed 40 PV OCPD Device Used 60 Tap or Breaker? Tap stance AL CU Wire Gauge �_ (QTY) Phase Neutral Neutral EGC (AWGy Wire Type Conduit Min. Conduit 90°C Rating Temp Correct Fill Derate Derated Ampacity ft � Conductors AWG L� L� Type 50 Cu #10 2 N/A N/A #6 PV Wire 600V AIR N/A 40 1 100% 40.00 50 CU #10 6 N/A N/A #10 THWN-2 EMT 0.75" 40 1 80% 32.00 10 CU #6 2 #8 1 #10 THWN-2 EMT 0.75" 75 1 100% 75.00 10 Cu #6 2 #6 1 #6 THWN-2 PVC 1" 75 1 100% 75.00 Site Conditions ASHRAE Site: Seattle Low Temp(°F) 19 High 2%Temp (°F) 84 High 0.4%Temp (°F) 91 75°C I Current I Operating_ I Voltage &*41./��. A&RSOL-AR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U a �� Lrn�o V) Lr) 00 +� V)Q V ��� J vi C^N-0 C)ON O L �O E ao O 00w 30 18.8 400 0.40% 30 18.8 400 0.40% 65 59.4 240 0.19% 65 59.4 1 240 1 0.�1% REVISIONS Rev. #: Date: May 07, 2021 Designed by: Thomas N Project Manager: Total Voltage Drop: 1.19% Nathan Bennett (805) 350-1823 Current Date:May 07, 2021 E2 Electrical Calculations Typical Placards A) NEC 2020 690.13 & 691.15 B) NEC 2020 705.12 (13)(3)(2) C) Utility Requirement D) Utility Requirement (Commercial Only) D) A&R Solar Requirement (Residential Customer -Owned) E) A&R Solar Requirement * if combiner used F) NEC 2020 690.13 (B) I) NEC 2020 690.31 (D)(2) K) NEC 2020 690.13 (B) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE SOLAR "OFF" POSITION TO ELECTRIC PV PANELS SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY L) NEC 2020 690.56 (C) *Used with Micro Inverters or DC Optimizers O) A&R Solar Requirement * if multiple inverters IAWARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM P) NEC 2020 705.12(C) & 690.59 R) AHJ Requirement * if combiner used S) NEC 2020 230.85(1) T) NEC 2020 230.85(3) NEC 690.54 H) NEC 690.53 NEC 6.54 Custom Placards PLACARD SPECS Q)TY Letter Height.1/8" Maintain1f4" border 1 Inverter Ra�k#eed Breaker Red J White Letter Keight. 118" MEI! eta€n 114" border 1 Saiar Edge SE11400H Red f White Letter Height. 1/8" (1) fi2r each MaintaFn 1/4' border I DisronnLit or upstream Red f White Ioadrenters. &M-1IPi. A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OFA&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U a Lrn�o d7� u 00 ro U) V p ��TI vi O�N-0 .rM%O O l0 N O O L �� E la o LU REVISIONS Rev. #: Date: 1 1 May 06, 2021 Designed by: Thomas N Project Manager: Nathan Bennett (805) 350-1823 Current Date:May 06, 2021 G4 Placards J) NEC 2020 690.56 (C)(2) Category Equipment QTY Notes Solar Equipment �- Modules LG-37CN1K-A6 38 A&RSOLAR Optimizers P370 Sol arEdge Dptirnizer 36 3211 Martin Luther King Jr Way S. Inverters Solar Edge SE114WH 1 Seattle, WA 98144(206)707-9937 Monitoring Solal-Ed�e Consumption Monitoring {2p20A breaker 1 Electrical Equipment )box J b o x 4 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT J� r } ` s i �7 C 5 E J� �,� f�+ r5 Vletel-Base Meteriiase-125A4Jaw w/3_5"AYYi�AP I CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS `,� C y �y �y���y�,-yy �y �y �} �y �} �y� r Meter Landfs Gyr EA 11G000-OP29 240Y 1 DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. Usconnect 60A 24GV 2 Pole i Heavy Duty, Fuse, Lockable 1 DH222N€ K UsconnectFuse FLNR- 60A Fuses for Disconnect (qty 1/pole) 1 ElectricalWork EV Cha rge r o utl et nerna 14-50) 1 U a M� Ln�0 `n 00 (U < V p ��00 T vi C�N-0 Solar Racking 'O fu c) O IronRldge Racking BOM L NON '--� E Des-cript on QTY 0 a o co w XR1D0B1ackr17' 4 X R100 BI a ck r 14' 17 Kit, XFUDC Bonded SpIi-ce BOSS 6 Universal Module CIamp, Black 98 Stopper Sleeve 40mm 44 Grounding Lug, LOIN Profhie 11 REVISIONS Square -Bolt Bond[ ngAttach ment.Hardware 74 Rev. #: Date: 1 May 07, 2021 1/4 x 314 Microlnverter Bonding Hardware, T-Boll 3S End Caps, 10 sets(package� XR100 3 IronRidge Flash Foot2, Black (Spacing: 72"i 74 Fastener- 5}16 x 4_75" Lag(lncluded) � 1 f rnount� Designed by: Thomas N Project Manager: System Welghts Nathan Bennett (805) 350-1823 Racking Weight(lbs) 336 Current Date:May 07, 2021 Total IrSfolght(lbs) 1591 ti We 26 G5 Equipment DeadLoad(PSF) 2.55 BOM