Loading...
REVIEWED BLD2021-1081+Manufacturer_Specifications_and_Installation_Instructions+7.29.2021_11.41.41_AM+2328548CITY OF EDMONDS nwoi nonnoniT coo�ni REVIEWED BY Indoor Unit: DEPARTMENT MSZ-HM12NA Outdoor Unit: MUZ-HM12NA Wireless Remote Controller CITY OF EDMONDS I�olllllllllllllliilillllli���, E`E"� ���al�Illlllllllllllul�l�' GENERAL FEATURES • Four fan speed options: Low, Medium, High, Super -high • Anti -mold filter • INVERTER -driven compressors and electronic LEVs provide higher efficiency with controlled power usage • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • Cooling operation range: 14° F to 115' F • Heating operation range: -4° F to 75° F • Multiple control options available: - Hand-held Remote Controller (provided with unit) - kumo cloud® smart device app for remote access - Third -party interface options - Wired or wireless controllers • 12-hour timer • ECONO COOL mode • AUTO restart • Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Maximum Capacity Btu/h 12,200 Rated Capacity Btu/h 12,000 Minimum Capacity Btu/h 3,800 Cooling Maximum Power Input W 1,300 Rated Power Input W 1,210 Moisture Removal Pints/h 2.5 Sensible Heat Factor 0.77 Power Factor % 95 / 95 Maximum Capacity Btu/h 14,500 Rated Capacity Btu/h 12,200 Heating 47°F2 Minimum Capacity Btu/h 4,500 at Maximum Power Input W 1,220 Rated Power Input W 990 Power Factor % 93 / 93 Maximum Capacity Btu/h 9,000 Heating 17°F3 Rated Capacity Btu/h 7,600 at Maximum Power Input W 990 Rated Power Input W 800 Heating 5°F4 Maximum Capacity Btu/h 7,440 at Maximum Power Input W 820 SEER 18.0 EERI 9.9 Efficiency HSPF (IV) 10.0 COP at 47°FZ 3.61 COP at 17°F in Maximum Capacity3 2.66 COP at 5°F in Maximum Capacity4 2.66 ENERGY STAR® Certified (ENERGY STAR products are third -party certified by an EPA -recognized Certification Body.) NO Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Electrical Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote Controller Wireless Type Recommended Fuse/Breaker Size A 15 Recommended Wire Size (Indoor - Outdoor) AWG 14 MCA A 1 MOCP A 15 Blower Motor Full Load Amperage A 0.76 Indoor Unit Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 399-321-237-170 Airflow Rate at Cooling, Wet CFM 364-286-201-134 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Airflow Rate at Heating, Dry CFM 406-321-237-170 Sound Pressure Level (Cooling) dB(A) 45-37-30-22 Sound Pressure Level (Heating) dB(A) 43-37-30-22 Drain Pipe Size In. (mm) 5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.OY 9.2/0.2 Unit Dimensions W: In. (mm) 31-7116 (798) D: In. (mm) 9-1/8 (232) H: In. (mm) 11-5/8 (295) Package Dimensions W: In. (mm) 33-1/2 (850) D: In. (mm) 12 (300) H: In. (mm) 14 (350) Unit Weight Lbs. (kg) 22 (10) Package Weight Lbs. (kg) 26 (11.5) Indoor Unit Operating Cooling Intake Air Temp (Maximum / Minimum)* °F 90 DB, 73 WB / 67 DB, 57 WB Temperature Range Heating Intake Air Temp (Maximum / Minimum) °F 80 DB / 70 DB MCA A 9 MOCP A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Airflow Rate CFM 1,151 / 1,225 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Coolingi dB(A) 49 Sound Pressure Level, Heating2 dB(A) 51 Compressor Type DC INVERTER -driven Twin Rotary Compressor Model KNB073FRVMC Outdoor Unit Compressor Rated Load Amps A 6.2 Compressor Locked Rotor Amps A 7.7 Compressor Oil Type // Charge oz. FV50S // 9.1 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Optional Unit Dimensions W: In. (mm) 31-1/3 (800) D: In. (mm) 11-1/5 (285) H: In. (mm) 21-5/9 (550) Package Dimensions W: In. (mm) 37 (940) D: In. (mm) 14-15116 (380) H: In. (mm) 24-13/16 (630) Unit Weight Lbs. (kg) 73 (33) Package Weight Lbs. (kg) 79 (36) Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling Air Temp (Maximum / Minimum)* °F 115 / 14 Outdoor Unit Operating Cooling Thermal Lock -out / Re -start Temperatures** °F -1 / 3 Temperature Range Heating Air Temp (Maximum / Minimum) °F 75 / -4 Heating Thermal Lock -out / Re -start Temperatures** °F -9 / -4 Refrigerant Type R410A Charge Lbs, oz 1,12 Gas Pipe Size O.D. (Flared) In. (mm) 3/8 (9.52) Liquid Pipe Size O.D. (Flared) In. (mm) 1/4 (6.35) Piping Maximum Piping Length Ft. (m) 65 (20) Maximum Height Difference Ft. (m) 40 (12) Maximum Number of Bends 10 Notes AHRI Rated Conditions 'Cooling (Indoor H Outdoor) °F 80 DB, 67 WB H 95 DB, 75 WB (Rated data is determined at a fixed 2Heating at 47°F (Indoor H Outdoor) °F 70 DB, 60 WB H 47 DB, 43 WB compressor speed) 3Heating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB H 17 DB, 15 WB Conditions 4Heating at 5*F (Indoor H Outdoor) °F 70 DB, 60 WB H 5 DB, 4 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Anti -allergy Enzyme Filter ❑ MAC-408FT-E Backlit, Wall -mounted, Wireless Controller ❑ MHK1 Portable Central Controller Wired MA Controllers ❑ MCCH1 ❑ PAR-33MAA Simple MA Controller' ❑ PAC-YT53CRAU Touch MA Controller) ❑ PAR-CT01 MAU-SB Wired Remote Sensor ❑ M21-EAA-307 Wireless Temperature and Humidity Sensor ❑ PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 ❑ MOS1 System Control Interface ❑ MAC-3331F-E Wireless Interface ❑ PAC-USWHS002-WF-1 Thermostat Interface ❑ PAC-US444CN-1 kumo station ❑ PAC-WHS01 HC-E USNAP Interface ❑ PAC-WHS01UP-E IT Extender ❑ PAC-WHS011E-E BACnet® and MODBUS® Interface ❑ PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers ❑ RCMKP1CB Blue Diamond Sensor Extension Cable —15 Ft. ❑ C13-103 Blue Diamond Alarm Extension Cable —6.5 Ft. ❑ C13-192 Blue Diamond MultiTank —collection tank for use with multiple pumps ❑ C21-014 Blue Diamond Rubber Foot Pads ❑ F10-010 Mini Condensate Pump —230 volt application ❑ S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor ❑ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 Btu/h [recommended] ❑ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] ❑ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 Btu/h ❑ X85-003 Fascia Kit for MicroBlue Pump — mounts the MicroBlue and sensor directly beneath the indoor unit ❑ T18-016 Drain Pan Level Sensor ❑ DPLS2 (30A/600WUL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 (30A/600WUL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W 1 Requires MAC-3331F-E 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide ❑ MAC-881 SG Drain Socket ❑ MAC-860DS Optional Defrost Heater ❑ MAC-640BH-U Hail Guard ❑ HG-B4 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD-400P Condensing Unit Mounting Pad 16" x 36" x 3" ❑ ULTRILITE1 Outdoor Unit Stand —12" High ❑ QSMS1201 M Outdoor Unit Stand —18" High ❑ QSMS1801 M Outdoor Unit Stand — 24" High ❑ QSMS2401 M Heavy Duty Wall Mounting Bracket —Coated Steel ❑ QSWB2000M-1 Heavy Duty Wall Mounting Bracket —316 Series Stainless Steel ❑ QSWBSS 15' x 1/4" x 15' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-15 30' x 1/4" x 30' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-30 50' x 1/4" x 50' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-50 65' x 1/4" x 65' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-65 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. t IIIMMMEmmEmil 9-1/8 3/16 Indoor u 3/4 I-15/16 24-3/8 _5-I/8i 22-1/�_11116 2-3/16 1-15/16 7/I6xl Oblona hol Air in Unit: inch Insulation o1 - 3/8 O.D c' Liquid line o1/4 19 - 11/16 (Flared connection o1/4) a Gas line o3/8 16 - 15/16 (Flared connection: 03/8 (09/12 kBtu/h), o1/2 (15 kBtu/h)) Drain hose Insulation 01-1/8 O.D Connected part o5/8 O.D Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. REQUIRED SPACE *1 4 in. or more when front and sides of the unit are clear 15-3/4 v Air in Drain hole 01-21/32 - o a Air in 1-0 m o oN m.c "2-holes x13/16 ac Lr FORM# MSZ-HM12NA / MUZ-HM12NA - 201903 4/n or\ more tno�ee*?' Cd a� U Unit: inch /I/ emote 14 /n o- 1 �r m V orc, '2 When any 2 sides of left, right and rear of the unit are clear 11/16 Liquid refrigerant pipe joint Refrigerant pipe (flared) o 1/4 N N Gas refrigerant pipe joint N Refrigerant pipe (flared) o 3/8 (09/12 kBtu/h) rn m 1/2 (15/18 kBtu/h) J-I I/- 6-23/32 4 MITSUBISHI /_ ELECTRIC COOLING & HEATING 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Eta . Intertek Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.