Project Information
�
���
zoo
N � �
���
�
W �
J
M
�n cn
A_aalicant
Anne +John Turnbull
Owner
Anne +John Turnbull
Aaent of owner and main contact
Loren Hill
206-910-7438
Loren.Hill@gmail.com
Assessors Parcel Number
00527800001400
Property Description
MUNGER ADD NO 2 BLK 000 D-00 -LOT 14
Property Address
7928 227 PL SW
EDMONDS, WA
98026
Project Description � O
Scope of work to include moving front door and pouring new concrete infill floor
slab. In addition, non bearing interior walls to be removed and an upgrade of O
bathroom and an added new 1/2 bath. Existing windows to be replaced as noted
on elevations. /
Code Notes
Zoning:
Set back:
Front Yard
Side Yard
Rear (Corner Lot)
Lot Coverage allowed
Existing House and eaves
New propoposed porch roof
Shed
Total lot coverage =
Building Height Allowed
Height Calculations:
Average Grade = 401.73'
Max Height = 426.73'
Lot Size
Building Area:
Heafed.�
House Floor Area:
Unheated.•
Attached Garage:
Buildina Code:
��
25 Feet
7.5 Feet
7.5 Feet
35 percent of total lot area
1,442 SF
160 SF
130 SF
25 Feet
A = 401.7', B = 401.7, C = 402.0', D = 401.5'
10,019 SF
Existing
992 SF
240 SF
Regulating Code: 2015 IRC as amended by the State of Washington
and the City of Edmonds
2015 Washington State Energy Code
Occupancy: R-3, Single Family Residence
Construction Type: V-N
Seismic Zone: 3
Wind Exposure: Exposure B
Energy/Mechanical:
Energy Code Compliance: New construction will adhere to 2015 Washington State Energy Code.
When porttions of existing interior
cavities are opened, best effort will be used to comply
with Energy Code
Building Envelope: Ceiling: (vaulted)
Ceiling: (attics)
Exterior Walls:
Below -Grade Wall
Under Slab -on -grade:
Floors over Unconditioned Space:
Window and Door Headers insulated min. R-10
Exterior Doors: Doors with raised sill U-Factor= 0.20 per manufacturer.
Glazing: See window schedule sheet A3
R-38
R-49
R-21
R-10/15/21 Int. + TB
R-10
R-30
O
J
J
Z
N
O
J �
as
t
ti �
N p
N Z
N �
O� �
ti p
W
PARCEL #
00527800001400
�
�
N
J
O
�
�
�
m
L(')
CD
�
�
�
z
�
�'
E
�
w
�
w
�o
�
�
�
�
�
a
a �
� O
adz
W W
H Q
to O
C�
EX. EX.
DS. DS.
2 \ ROOF PLAN
SCALE 1/4" = 1'-0"
0 4 8
0 o i o
`T
1 \ FLOOR PLAN
SCALE 1 /4" = 1'-0"
0 4 8
0 o i o
`T
O `�
0
p zrn
� wQ�
� Q��
C� o LLi o
Z J �
_ ��°'
Ur Q �
M W O
J �n c�
O
O
2
O
�/ � �
I.L �
J
O � Q
s �
a ti �
N p
J N Z
� O
J��
ti p
� w
Z
H
PARCEL #
00527800001400
�
o
N
�
J
�
o
M
l!')
ri
CV
�
m
Z
�
�
0
w
�--�
a
(A
�
oa
Z
O�
�a
WINDOW SCHEDULE
LOCATION
DESCRIPTION
TYPE
SIZE WxH -FRAME
AREA SF
U-VALUE
NOTES:
ID.
� � , -
VGA
N 1
NOT USED
N2
EX . OP
rinse ries
3'-8"
0.3
VERIFY EGRESS
N3
EXIST. OPNG.
Trinsic Series
SLIDER
6'-0"X3'-8"
0.3
VERIFY EGRESS
S1
EXIST. OPNG.
Trinsic Series
SLIDER
6'-0"X3'-8"
0.3
VERIFY EGRESS
S2
EXIST. OPNG.
Trinsic Series
SLIDER
2'-10"X2'-2"
0.3
SAFETY GLASS
§�,
--
-,-
S4
NOT USED
S5
NOT USED
E 1
NOT USED
TOTAL
x.
D2
SOLID FRONT DOOR W/ LITES
3'-0"X7'-0"
KEY:
Trinsic Series =Mil uard Trinsic Series Vin I Window and Doors with SunCoat Low-E2 lass
Tuscan Series =Mil uard
Trinsic Series Vin I Window and Doors with SunCoat Low-E2 lass
S =SOUTH
N =NORTH
W =WEST
E =EAST
WINDOW SCHEDULE
GRADE
<�
SILL
NORTH ELEVATION
0❑ o0
3 \ SOUTH ELEVATION
A3
n
s
SCALE 1 /4" = 1'-0"
o a
0 0 � o
SCALE 1 /4" = 1'-0"
o a a
0 0 � o
� �o
� w°
QQ�
� 030
= z��
N
M W �
J �n cn N,
O
O
i �
N
O
J �
�aa
s�
a ti v�
N p
J N Z
J�o
tip
W
Z
PARCEL #
00527800001400
�
o
N
J
�
o
M
�
cYi
N
�
m
z
�
�
�
w
�
�o
�
�
�
�
>
W
�
a
°C
OQ
z
OJ
�a
■ \�I
GENERAL STRUCTURAL NOTES
(THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE PLANS)
CRITERIA
1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE
DRAWINGS, SPECIFICATIONS & THE INTERNATIONAL BUILDING CODE (2015 EDITION).
FLOOR LIVE LOAD (RESIDENTIAL) 40 PSF
ROOF SNOW LOAD (Pf ) 25 PSF
EARTHQUAKE:
LAT. /LONG.
47. 793 /-122.341
SEISMIC IMPORTANCE FACTOR (Ie)
1.0
SE I SM I C USE GROUP.
I
MAPPED SPECTRAL RESPONSE (Ss/S1).
1.26g/0.49g
SPECTRAL RESPONSE COEF. (SDS/SD1)
0.84g/0.49g
SEISMIC FORCE RESISTING SYSTEM:
PLYWOOD SHEAR WALLS
DESIGN BASE SHEAR .
0.28k
SEISMIC RESPONSE COEFICIENT (Cs).
0.130
SE I SM I C DESIGN CATEGORY.
D
RESPONSE MODIFICATION FACTOR (R)
6.5
ANALYSIS PROCEDURE .
.EQUIVALENT LATERAL FORCE
REFERENCE: USGS NATIONAL SEISMIC HAZARD MAPPING PROJECT, 2008 DATA
3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL
DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS
AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CON-
DITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CON-
STRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST
VERIFIED. CONTRACTOR SHALL DETERMINE THE LOCATION OF ALL ADJACENT
UNDERGROUND UTILITIES PRIOR TO COMMENCING EXCAVATION. THE CONTRACTOR SHALL
BRING ALL CONFLICTS AND DISCREPANICES TO THE ATTENTION OF THE ARCHITECT
AND STRUCTURAL ENGINEER.
5. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY
DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION
AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. EXISTING
REINFORCING SHALL BE RETAINED UNDAMAGED WHERE NOTED ON THE PLANS.
DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING
STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON
EXISTING FLOOR SYSTEMS TO 40 PSF. ALL NEW OPENINGS THROUGH EXISTING
CONCRETE OR MASONRY WALLS, SLABS AND BEAMS SHALL BE ACCOMPLISHED BY SAW
CUTTING WHEREVER POSSIBLE.
6. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND
STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN
ACCORDANCE WITH THE PLANS.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE
METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK.
THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL
AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE
SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CON-
TRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE,
CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES OF THE OWNER, CON -
CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE.
8. SPECIAL INSPECTION OF EPDXY GROUTED INSTALLATIONS SHALL BE PROVIDED IN
ACCORDANCE WITH SECTIONS 109 AND 1704 OF THE INTERNATIONAL BUILDING CODE
AND THE PROJECT SPECIFICATIONS BY A QUALIFIED TESTING AGENCY DESIGNATED
BY THE ARCHITECT, AND RETAINED BY THE BUILDING OWNER. THE ARCHITECT,
STRUCTURAL ENGINEER, AND BUILDING DEPARTMENT SHALL BE FURNISHED WITH
COPIES OF ALL INSPECTION AND TEST RESULTS.
�elxlll�lla►1[1L11
9. FOUNDATION NOTES: ALLOWABLE SOIL PRESSURE AND LATERAL EARTH PRESSURE ARE
ASSUMED AND THEREFORE MUST BE VERIFIED BY A QUALIFIED SOILS ENGINEER. IF
SOILS ARE FOUND TO BE OTHER THAN ASSUMED, NOTIFY THE STRUCTURAL ENGINEER
FOR POSSIBLE FOUNDATION REDESIGN.
FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW ADJACENT
FINISHED GRADE. UNLESS NOTED OTHERWISE, FOOTINGS SHALL BE CENTERED BELOW
COLUMNS OR WALLS ABOVE. BACKFILL BEHIND ALL RETAINING WALLS WITH FREE
DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE.
ALLOWABLE SOIL PRESSURE 2,000 PSF
LATERAL EARTH PRESSURE . 35 PCF
CONCRETE
10. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORD-
ANCE WITH ACI 301. CONCRETE SHALL ATTAIN A 28DAY STRENGTH OF F'C = 2,500
PSI AND MIX SHALL CONTAIN NOT LESS THAN 5-1/2 SACKS OF CEMENT PER CUBIC
YARD AND SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS.
THE MINIMUM AMOUNTS OF CEMENT AND MAXIMUM AMOUNTS OF WATER MAY BE CHANGED
IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE STRUCTURAL ENGINEER AND
THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CON-
CRETE. THE CONCRETE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT,
FINE AND COARSE AGGREGATE, WATER AND ADMIXTURES AS WELL AS THE WATER CE-
MENT RATIO, SLUMP, CONCRETE YIELD AND SUBSTANTIATING STRENGTH DATA IN
ACCORDANCE WITH ACI 301. REVIEW OF MIX SUBMITTALS BY THE ENGINEER OF
RECORD INDICATES ONLY THAT INFORMATION PRESENTED CONFORMS GENERALLY WITH
CONTRACT DOCUMENTS. CONTRACTOR OR SUPPLIER MAINTAINS FULL RESPONSIBILITY
FOR SPECIFIED PERFORMANCE.
19. GLUED LAMINATED MEMBERS SHALL BE FABRICATED IN CONFORMANCE WITH ASTM AND
AITC STANDARDS. EACH MEMBER SHALL BEAR AN AITC IDENTIFICATION MARK AND
SHALL BE ACCOMPANIED BY AN AITC CERTIFICATE OF CONFORMANCE. ALL SIMPLE
SPAN BEAMS SHALL BE DOUGLAS FIR COMBINATION 24FV4, FB = 2,400 PSI, FV =
165 PSI. ALL CANTILEVERED BEAMS SHALL BE DOUGLAS FIR COMBINATION 24FV8,
FB = 2400 PSI, FV = 165 PSI. CAMBER ALL SIMPLE SPAN GLULAM BEAMS TO 2,000'
RADIUS, UNLESS SHOWN OTHERWISE ON THE PLANS. ALL COLUMNS SHALL BE DOUGLAS
F I R COMBINATION N0. 5, FC = 2400 PSI, E = 2. 0 X 10E6 PSI .
20. PLYWOOD SHEATHING SHALL BE GRADE C-D, EXTERIOR GLUE OR STRUCTURAL II,
EXTERIOR GLUE IN CONFORMANCE WITH APR STANDARDS. ORIENTED STRAND
BOARD OF EQUIVALENT THICKNESS, EXPOSURE RATING AND SPAN RATING MAY BE
USED IN LIEU OF PLYWOOD.
ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR
ENTRAINED WITH AN AIRENTRAINING AGENT CONFORMING TO ASTM C260, C494, AND
C618. TOTAL AIR CONTENT SHALL BE IN ACCORDANCE WITH TABLE 19.3.2.1 OF THE 21
ACI 318.
11. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1),
GRADE 60, FY = 60,000 PSI. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185.
12. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORD-
ANCE WITH ACI 318. LAP ALL CONTINUOUS REINFORCEMENT 40 BAR DIAMETERS
OR 2'0" MINIMUM. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTER-
SECTIONS. LAP CORNER BARS 40 BAR DIAMETERS OR 2'0" MINIMUM. LAP
ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS.
13. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS:
A. FOOTINGS AND OTHER UNFORMED SURFACES, EARTH FACE . .3"
B. ALL OTHER SURFACES . . 1 1/2"
14. NON -SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND
SHALL BE MIXED AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S
PUBLISHED RECOMMENDATIONS. GROUT STRENGTH SHALL BE AT LEAST EQUAL TO
THE MATERIAL ON WHICH IT IS PLACED (3000 PSI MINIMUM).
ANCHORAGE
15. EXPANSION BOLTS INTO CONCRETE AND GROUTED MASONRY UNITS SHALL BE
"STRONG -BOLT" ANCHORS AS MANUFACTURED BY THE SIMPSON COMPANY AND
INSTALLED IN STRICT ACCORDANCE WITH ICC ESR 1771, INCLUDING MINIMUM
EMBEDMENT REQUIREMENTS.
16. EPDXY -GROUTED ITEMS SPECIFIED ON THE DRAWINGS SHALL BE GROUTED WITH
"SET-XP" HIGH STRENGTH EPDXY AS MANUFACTURED BY THE SIMPSON COMPANY
AND INSTALLED IN STRICT ACCORDANCE WITH ICC ESR 2508.
17. TITEN HD ANCHORS SPECIFIED ON THE DRAWINGS SHALL CONSIST OF "TITEN HD"
HEAVY DUTY SCREW ANCHORS AS MANUFACTURED BY THE SIMPSON COMPANY AND
INSTALLED IN STRICT ACCORDANCE WITH ICC ESR 2713.
I�i�[IIIl11
18. FRAMING LUMBER SHALL BE KILN DRIED OR MC-15, AND GRADED AND MARKED IN CON-
FORMANCE WITH WCLIB STANDARD GRADING RULES FOR WEST COAST LUMBER N0. 17,
LATEST EDITION. FURNISH TO THE FOLLOWING MINIMUM STANDARDS:
JOISTS: (2X MEMBERS) HEM -FIR N0. 2
MINIMUM BASE VALUE, FB = 850 PSI
(3X & 4X MEMBERS) DOUGLAS FIR N0. 1
MINIMUM BASE VALUE, FB = 1000 PSI
A. ROOF SHEATHING SHALL BE 1/2" (NOM.) WITH SPAN RATING 24/0.
B. FLOOR SHEATHING SHALL BE 3/4" (NOM.) WITH SPAN RATING 40/20.
C. WALL SHEATHING SHALL BE 1/2" (NOM.) WITH SPAN RATING 24/0.
REFER TO WOOD FRAMING NOTES BELOW FOR TYPICAL NAILING.
ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -
TREATED WITH AN APPROVED PRESERVATIVE OR (2) LAYERS OF ASPHALT IMPREGNATED
BUILDING PAPER SHALL BE PROVIDED BETWEEN UNTREATED WOOD AND CONCRETE OR
MASONRY. ALL WOOD EXPOSED TO WEATHER WITHOUT THE ADEQUATE PROTECTION OF
A ROOF OR EAVE SHALL BE AN APPROVED WOOD OF NATURAL RESISTANCE TO DECAY
OR PRESSURE TREATED. SUCH MEMBERS INCLUDE HORIZONTAL MEMBERS SUCH AS
GIRDERS, JOISTS, AND DECKING; OR VERTICAL MEMBERS SUCH AS POSTS, POLES,
AND COLUMNS.
22. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE"
BY SIMPSON COMPANY, AS SPECIFIED IN THEIR MOST RECENT CATALOG. EQUIVALENT
DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC
APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF
FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONNECTOR STRAPS
CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS OR BOLTS IN EACH MEMBER.
ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS
UNDER THE HERDS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. UN-
LESS NOTED OTHERWISE, ALL NAILS SHALL BE COMMON. ALL SHIMS SHALL BE SEA-
SONED AND DRIED AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. HANGERS
IN DIRECT CONTACT WITH PRESERVATIVE -TREATED WOOD SHALL BE EITHER STAINLESS
STEEL (SST300), POST HOT -DIPPED GALVANIZED(HDG) OR GALVANIZED WITH A MINI-
MUM OF 1.850Z ZINC PER SQUARE INCH (ZMAX). UNLESS NOTED OTHERWISE, ALL
LUMBER JOISTS SHALL BE CONNECTED TO FLUSH BERMS WITH "LUS" SERIES JOIST
HANGERS, AND ALL TJI JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "ITT"
OR " I UT" SERIES JOIST HANGERS.
23. NAILS -NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING
SPECIFICATIONS:
SIZE LENGTH DIAMETER
6D 2" 0. 113"
8D 2-1/2" 0. 131"
10D 3" 0. 148"
12D 3-1/4" 0. 148"
16D 3-1/2" 0. 162"
IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT
NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION)
FOR REVIEW AND APPROVAL. NAILS SHALL BE DRIVEN FLUSH TO FACE OF
SHEATHING WITH NO COUNTERSINKING PERMITTED.
24. WOOD FRAMING NOTESTHE FOLLOWING APPLY UNLESS OTHERWISE SHOWN:
A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED
TO THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE. MINIMUM
NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO TABLE 2304.10.1 OF
THE INTERNATIONAL BUILDING CODE. UNLESS NOTED OTHERWISE, ALL NAILS
SHALL BE COMMON. COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS
WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. PROVIDE WASHERS UNDER
THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD.
B. WALL FRAMING: ALL STUD WALLS SHOWN AND NOT OTHERWISE NOTED SHALL BE
2X4 STUDS @ 16" O.C. AT INTERIOR WALLS AND 2X6 @ 16" O.C. AT EXTERIOR
WALLS. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS
AND AT EACH SIDE OF ALL OPENINGS. TWO 2X8 HEADERS SHALL BE PROVIDED
OVER ALL OPENINGS NOT OTHERWISE NOTED. SOLID BLOCKING FOR WOOD COL-
UMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. WALLS SHALL
HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE
TO EACH STUD WITH TWO 16D NAILS, AND TOENAIL OR END NAIL EACH STUD TO
BOTTOM PLATE WITH TWO 16D NAILS. FACE NAIL DOUBLE TOP PLATE WITH 16D
AT 12" O.C. AND LAP MINIMUM 4'-0" AT JOINTS AND PROVIDE SIX 16D NAILS
AT 4" O.C. EACH SIDE OF JOINT. ALL STUD WALLS SHALL HAVE THEIR LOWER
WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16D NAILS AT 12" O.C.
STAGGERED OR BOLTED TO CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS (WITH
7" M I N I MUM EMBEDMENT) @ 4' 0" 0. C. UNLESS I ND I CATED OTHERWISE. I ND I V I -
DUAL MEMBERS OF BUILTUP POSTS SHALL BE NAILED TO EACH OTHER WITH
16D @ 12" O.C. STAGGERED. REFER TO THE PLANS AND SHEAR WALL SCHEDULE
FOR REQUIRED SHEATHING AND NAILING. WHEN NOT OTHERWISE NOTED, PROVIDE
GYPSUM WALLBOARD ON INTERIOR SURFACES NAILED TO ALL STUDS, TOP AND
BOTTOM PLATES AND BLOCKING WITH NAILS AT 7" O.C. USE 5D COOLER NAILS
FOR 1/2" GWB AND 6D COOLER NAILS FOR 5/8" GWB. WHEN NOT OTHERWISE
NOTED, PROVIDE 1/2" (NOM.) APA RATED SHEATHING (SPAN RATING 24/0) ON
EXTERIOR SURFACES NAILED AT ALL PANEL EDGES (BLOCK UNSUPPORTED EDGES),
TOP AND BOTTOM PLATES WITH 8D @ 6" O.C. AND TO ALL INTERMEDIATE STUDS
AND BLOCKING WITH 8D @ 12" O.C. ALLOW 1/8" SPACING AT ALL PANEL EDGES
AND ENDS.
C. FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS AROUND ALL OPENINGS IN
FLOORS OR ROOFS UNLESS OTHERWISE NOTED. PROVIDE SOLID BLOCKING AT ALL
BEARING POINTS. TOENAIL JOISTS TO SUPPORTS WITH TWO 16D NAILS. ATTACH
TIMBER JOISTS TO FLUSH HEADERS OR BEAMS WITH METAL JOIST HANGERS IN
ACCORDANCE WITH TIMBER CONNECTOR NOTE. NAIL ALL MULTIJOIST BEAMS TO-
GETHER WITH 16D @ 12" O.C. STAGGERED. UNLESS OTHERWISE NOTED ON THE
PLANS, ROOF AND FLOOR SHEATHING SHALL BE LAID UP WITH STRENGTH AXIS
PERPENDICULAR TO SUPPORTS AND NAILED WITH 8D NAILS @ 6" O.C. TO FRAMED
PANEL EDGES AND OVER STUD WALLS AS SHOWN ON PLANS AND @ 12" O.C. TO
INTERMEDIATE SUPPORTS. PROVIDE APPROVED PLYWOOD EDGE CLIPS CENTERED
BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR
SHEATHING EDGES SHALL HAVE APPROVED TONGUEANDGROOVE JOINTS OR SHALL
BE SUPPORTED WITH SOLID BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL
EDGES AND ENDS OF ALL ROOF AND FLOOR SHEATHING. TOENAIL BLOCKING TO
SUPPORTS WITH 16D @ 12" O.C. UNLESS OTHERWISE NOTED. AT BLOCKED FLOOR
AND ROOF DIAPHRAGMS PROVIDE FLAT 2X BLOCKING AT ALL UNFRAMED PLYWOOD
PANEL EDGES AND NAIL WITH EDGE NAILING SPECIFIED.
Harriott Valentine Engineers Inc.
1932 First Avenue, Suite 720
Seattle, Washington 98101-2447
tel 206 624 4760 fax 206 447 6971
www.harriottvalentine.com
54220 �����
`d��°��
���� ��� o�r�ona
Project Contact
Jack Hupp
tel 206 624 4760 ex. 36
fax 206 447 6971
jhupp@harriottvalentine.com
Project Architect
LGH Studio
5319 2nd Ave NW
Seattle. WA 98107
Project
Turnbull Remodel
7928 227th PI SW
Edmonds, WA 98026
Issue Date Issue Description
05/30/19 Permit
STRUCTURAL LIGHT FRAMING: DOUGLAS FIR N0. 2
(INCL. 3X AND 4X POSTS) MINIMUM BASE VALUE, FB = 900 PSI
Building Department Approval
BEAMS AND STRINGERS: DOUGLAS FIR N0. 1
(INCL. 6X AND LARGER) MINIMUM BASE VALUE, FB = 1350 PSI
POSTS AND TIMBERS: DOUGLAS FIR N0. 1
(6X6 AND LARGER ) MINIMUM BASE VALUE, FC = 1000 PSI
STUDS, PLATES & MISC. FRAMING: DOUGLAS FIR OR HEM -FIR STANDARD GRADE
2X6 STUDS AND PLATES: HEM -FIR N0.3/ STUD GRADE
2X AND 3X T & G DECKING HEM -FIR COMMERICAL DEX,
MINIMUM BASE VALUE, FB = 1350 PSI
Drawing Title
GENERALSTRUCTURAL
NOTES
Drawing Number
S1.0
J
w
0
O
w
J
J
m
z
o �o
o ���
M
Q
� ��o
= Z � �
N
M W �
J �n cn
O
O
O
a
J
J
m
Z
GC
N
O
J �
as
��
ti�
N p
N Z
N �
o� �
tip
w
PARCEL #
00527800001400
�
rn
o
N
J
o
M
�
�
ri
N
�
m
L(j
CD
�
�
W
�
W
Z
�
�
�
_�
>
_�
>
�o
d
�
�
W
�
W
�
a
J
J
�
H
V
�
W
GC
�
H