FIR2023-0021+Fire_Alarm_Equipment_Specification_Sheets+3.10.2023_2.16.27_PM+3414724FIR2023-0019 Honeywell 5ILENT'' KNIGHT [POU1I11 Addressable Fire Alarm Control Panels Addressable Fire Alarm Control Panel The 6700 is an addressable fire alarm control panel (FACP) that is a direct replacment for the 5700 FACP. The 6700 can be configured to achieve a point capacity of up to 100 points. It has one built-in signaling line circuit (SLC), which can support 50 System Sensor' (SK) sensors and 50 SK modules or 50 Hochiki° (SD) devices. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single -point communications. The 6700 also has a built-in, dual -line POTS and IP communicator with additional cellular options available. The 6700 system can be enhanced by adding modules such as the 6860 remote annunciator which also has four programmable function buttons to help automate tasks and reduce time spent atthe panel. SWIFT° wireless compatibility provides options for wireless detection through a Class A mesh network. It is ideal for hard -to -wire locations, buildings where new wiring is not allowed, orto provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard -wired 6700 compatible devices. SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. The 6700 also has a form-C trouble relay, two programmable form-C relays, along with powerful features such as drift compensation, pre - trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and calibration trouble alert. FEATURES & BENEFITS • Capable of providing up to 100 points to satisfy smaller installation needs • Connect up to 17 panels on one site with convenient single - point access using the SK-NIC Network Interface Card. Connected panels can have mixed compatible FACP models • Convenient field-upgradeable firmware • Built-in dual path POTS and IP communications with optional cellular models available for reliable backup reporting • 6860annunciatorwith a 4 x 40 large display • Four user - programmable buttons minimize time spent executing complex or routine tasks • Built-in USB interface for convenient and quick programming 6700 RECEIVEI Mar 10 2023 CITY OF EDMOND$ DEVELOPMENTSERVICE$ DEPARTMENT The 6700 supports a variety of devices, including the 6860, 5860, and 6855 remote annunciators, 5824 serial parallel printer interface module (for printing system reports), the 5496 NAC expander, 5895XL power module, and SK or SD devices. • Programmable date setting for automatic and convenient Daylight Saving Time changes • JumpStart° auto programming reduces installation time • 125 software zones and 125 output groups for flexible design options SIGNAL LINE CIRCUIT (SLC) The 6700 SLC loops support multiple device types, maintenance alerts, and a built-in sensor test to comply with NFPA 72 calibration testing requirements. INDICATOR LIGHTS • General Alarm (Red): Flashes if in alarm; solid when alarm is silenced • Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced • System Trouble (Yellow): Flashes if a trouble condition exists; solid when trouble is silenced • System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared • System Power (Green): Flashes forAC failure; solid when power systems are normal USERINTERFACE The 6700 built-in 4 x 20 annunciator with 80 character LCD display and large easy -to -use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built- in or remote annunciator. System operations can be initiated with a mechanical firefighter's key or a valid 4- to 7-digit operator's code. PROGRAMMING The 6700 system offers several options to simplify and speed-up programming. JumpStart° auto programming minimizes programming required to start a new system. The built-in keypad, or the 6860, 5860 or 6855 remote annunciators give you on -site access to current system programming. Programming can also be accomplished using the Windows° -based Honeywell Fire Software Suite (HFSS) program. SOFTWARE TOOLS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows° software system configuration toolto create a detailed Bill of Material (BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires PC running Microsoft' Windows°. ADDITIONAL INFORMATION Twisted -unshielded pairwire is recommended. The 6700 also has 13 preset notification cadence patterns (including ANSI 3.41). AGENCY LISTINGS AND APPROVALS NPFA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non -coded) signaling services • UL Listed: S2766 • CSFM 7165-0559:0501 • FDNY COA# 6250 101:7ol4:711,1411.11d01:1LvJAd DIZZ' 6700: Addressable Fire Alarm Control Panel. (Red cabinet) ld•]kkv,1]eAdW11=Fe12RlIRIII /e1i 6860: 4x40 LCD remote fire annunciator (4 lines and up to 160 characters) per system; four programmable buttons 5860: 4x20 LCD remote fire annunciator. 5860 is gray; 586OR is red 6855:4x20 LCD remote fire annunciator 5865-3 or 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). The 5865-4 has key switches for silence and reset, and a system trouble LED. 5880: The 5880 LED / 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6700 COMPATIBLE DEVICES AND ACCESSORIES See the data sheets listed below for a complete listing of the SK, SD or SWIFT devices. 53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614, 350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories, visit www.sitentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. Page 2 of 4 — 3516073 9/26/2018 SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135OF fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T. Reflected beam smoke detector with testfeature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended airspeed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (135°F), white SK-HEAT-ROR: Fixed rate of rise detector (135°F) SK-HEAT-ROR-W: Fixed rate of rise detector (135°F), white SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-HEAT-HT-W: Fixed high temperature thermal detector (19019, white SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector, white SK-PHOTO-T. Photoelectric smoke detector with thermal (135°F fixed temperature) SK-PHOTO-T-W: Photoelectric smoke detector with thermal (135°F fixed temperature), white SK-PHOTOR: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detector with remote test capability, white SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2:Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module B300-6(-IV): 6" base for SK-W Series B210LP: 6" mounting base B501(-BL,-IV,-WHITE):4"flangeless base B501:4" Flangeless mounting base B200S(-IV,-WH): Intelligent sounder base B200S: Intelligent sounder base 13200S-LF(-IV,-WH): Low -Frequency intelligent sounder base B200S-LF: Low -frequency intelligent sounderbase 13224RB(-IV,-WH): Relay base B224RB: Relay base B224131(-IV,-WH): Isolator base B224B1: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6" base SD505-61B: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch and LED indicator for theSD505-DUCTR SD505-DUCT:Addressable Duct Smoke Detector. SD505-DUCTR:Addressable Duct Detector housing with relay base. SD505-HEAT: Absolute temperature heat detector. Trip point range from 1350E-150OF(OOC-370C). SD500-LIM: Addressable Line isolator module SD500-MIM:Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA:Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: "R" indicates red; "W" denotes white. For a complete listing of Silent Knight AV devices go to www.sitentknight.com. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime HRL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Photoelectric smoke detector WSK-PHOTO-T. Wireless Multi -criteria photoelectric smoke detectorwith thermal detection (1350F fixed temperature) and 3510W 4" base WSK-HEAT: Wireless Heat, (1351Ffixed temperature) and B510W 4" base WSK-HEAT-ROR: Wireless heat, ROR (135°F fixed temperature) and B510W 4" base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module W-USB: SWIFT Tools USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 5496: A 6 amp notification power expander with four power -limited notification appliance circuit outputs. 5883: Relay interface. Provides 10 Form C relays. 5824: Serial/Parallel printer interface module for printer connection. 5895XL: Power supply with six Flexput° circuits, and two Form C relays. Max. 16 per system. 5815RMK: Remote mounting kit. Dimensions 10 3/8"W x 10-3/16"H x 3"D COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock/key* CELL -MOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP-2: Remote reporting via the Internet. Requires a VisorAlarm® receiver at the central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications linkforthe 6700 SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber -Optic Multi Mode, transmitter and receiver SK-FSL: Fiber -Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too large to fit in the FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406mm W x 254mm H x 152mm D). SK-SCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. Page 3 of 4 — 351607:13 9/26/2018 6700 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS (NACs) Flexput°, Honeywell', Overall Dimensions: 12.71" W x 15.12" H x 3.33" D Two programmable circuits which can be JumpStart°, Silent Knight®, SWIFT°, and System Weight: 15 lbs. programmed individually as: Sensor' are registered Color: Red NACs: 2.5A C 27.4VDC per circuit, power -limited trademarks of Honeywell (with a panel maximum current of 2.5A) International Inc. Auxiliary Power Circuits: 2.5A C� 27.4VDC per ENVIRONMENTAL circuit, power -limited Hochiki° is a registered Operating Temperature: 32°Fto 120°F (01Cto trademark of Hochiki 49°C) Corporation. Microsoft® Humidity:0 to 93% relative humidity(non- Supports Class B (Style 4) and Class A (Style 6 or 7) and Windows° are configuration for the SLC registered trademarks of condensing) Microsoft Corporation. ELECTRICAL WIRING: Seethe product manual for wiring details This document is not 6700 Primary AC: 120 VAC C 60 Hz,1.5A Total intended to be used for installation We Accessory Load: 2.5A C� 27.4 VDC power -limited try tokeep our product Standby Current: 165mA information up -to Alarm Current: 310mA date and accurate. We Battery Charging Capacity: 7 to 35AH cannot cover all specific Battery Size: 7AH max. allowed in control panel applications or anticipate all requirements. All cabinet. Larger capacity batteries can be housed in specifications are subject RBB accessory cabinet. to change without notice. For Technical Support, call 800-446-6444. Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 Honeywell 800-328-0103 EN 3e1607 I e I osila SILENT' www.sitentknight.com © 2018 Honeywell International Inc. IQtiTIGI-TF