Loading...
REVIEWED BLD2022-1311+Manufacturer_Specifications_and_Installation_Instructions+9.29.2022_3.19.00_PM+3137176RECEIVED Sep 29 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 .d Fig. 1 — Size 12K Fig. 2 — Sizes 18K-58K Product Data NOTE: Images are for illustration purposes only. Actual models may differ slightly. TABLE OF CONTENTS INDUSTRY LEADING FEATURES / BENEFITS ........................ I MODEL NUMBER NOMENCLATURE ....................................... 3 STANDARD FEATURES AND ACCESSORIES .........................4 DIMENSIONS................................................................................. 5 CLEARANCES................................................................................ 7 SPECIFICATIONS.........................................................................8 COMPATIBILITY........................................................................... 8 APPLICATION DATA................................................................... 9 WIRING...........................................................................................10 AIRFLOWDATA..........................................................................11 SOUND PRESSURE.......................................................................11 SOUND PRESSURE TESTING METHOD ................................... I I ELECTRICAL DATA.....................................................................12 FAN AND MOTOR SPECIFICATIONS........................................12 WIRING DIAGRAMS.....................................................................13 GUIDE SPECIFICATIONS.............................................................18 BLD2022-1311 INDUSTRY LEADING FEATURES / BENEFITS A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT The 40MBFQ series ductless system are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires. The fan coil can be mounted on the floor, against the wall on all the sizes 12-58 and mounted on the ceiling on the sizes 18-58. This selection of fan coils permits creative solutions to design problems such as: • Add-ons to current space (an office or family room addition) • Special space requirements • When changes in the load cannot be handled by the existing system • When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork • Historical renovations or any application where preserving the look of the original structure is essential. The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork. The compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels. V v��'K cp'�'� Specifications subject to change without notice. LOW SOUND LEVELS BUILT-IN RELIABILITY When noise is a concern, the ductless systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork. SECURE OPERATION If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since outdoor units can be installed close to an outside wall, coils are protected from vandals and severe weather. FAST INSTALLATION This compact ductless system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping need to be run between the indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the ductless systems the equipment of choice, especially in retrofit situations. SIMPLE SERVICING AND MAINTENANCE Removing the top panel on the outdoor units provides immediate access to the control compartment, providing a service technician access to check the unit's operation. In addition, the draw-thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent. On all indoor units, service and maintenance expense is reduced due to easy -to -use cleanable filters. In addition, these console systems have extensive self -diagnostics to assist in troubleshooting. Ductless system indoor and outdoor units are designed to provide years of trouble -free operation. The console indoor units include protection against freeze-up and high evaporator temperatures on heat pumps. The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over -current protection and the high temperature protection. INDIVIDUAL ROOM COMFORT Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year-round comfort can be provided with heat pumps. ECONOMICAL OPERATION The ductless system design allows individual room heating or cooling when required. There is no need to ran large supply -air fans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted moving air through ducts. EASY -TO -USE CONTROLS The console units have microprocessor -based controls to provide the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between user and the unit. ACCESSORIES Customizing these ductless systems to your application is easily accomplished. Adding a condensate pump accessory to the console fan coil provides installation flexibility. OPTIONAL WIRED CONTROLLER AGENCY LISTINGS All systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute), and ETL. 2 Specifications subject to change without notice. 40MBFQ-03PD MODEL NUMBER NOMENCLATURE 40 = FAN COIL UNIT INDOOR FAN COILTYPE F = CONSOLE NOMINAL CAPACITY 12-1TON 24-2TONS 36-3TONS 48-4TONS 58-5TONS INDOOR UNIT 40 MB F Q �TIFIFr Use of the AHRI Certified TM Mark indicates a manufacturer's paniclpation in the program For verification of certification for individual products, go to www.ahrld irectory.org. m 3 40MBFQ-03PD Specifications subject to change without notice. 3 STANDARD FEATURES AND ACCESSORIES Ease Of Installation Mounting Brackets S Low Voltage Controls S Floor Mounting Installation (Sizes 12 - 58) S Ceiling Installation (Sizes 18 - 58) S Comfort Features Microprocessor Controls S Wired Remote Control A Wireless Remote Control S Wi-Fi Remote Control (Sizes 18 - 58 Only) A Automatic Up -Down Air Sweep S Air Direction Control S Auto Restart Function S Cold Blow Protection On Heat Pumps S Freeze Protection Mode On Heat Pumps S Turbo Mode S Silence Mode S Auto Changeover On Heat Pumps S Follow Me S Energy Saving Features Sleep Mode S Stop/Start Timer S 460 F Heating Mode (Heating Setback) S Safety And Reliability Indoor Coil Freeze Protection S Aluminum Hydrophilic pre -coated fins S Indoor Coil High Temp Protection in Heating Mode S Ease Of Service And Maintenance Cleanable Filters S Diagnostics S Liquid Line Pressure Taps S Application Flexibility Condensate Pumps A Legend S - Standard A - Accessory Accessories ORDERING NO. DESCRIPTION FOR MODELS 53DS-900---118 Condensate Pump (230v) All Sizes KSACN0101AAA Wired Remote Control All Sizes KSACN0401AAA Wired Remote Control 7 Day Programmable compatible with indoor units starting with serial number 0217V10001 Size 12 KSACN0501AAA Wired Remote Control 7 Day Programmable Sizes 18 - 58 KSAIF0401AAA Wi-Fi Kit Sizes 18 - 58 Only KSAIC0301230 24V Interface Kit 208/230V All Sizes* 53DS-900---008 Insulated 25' Line Set -1/4"x 1/2" Sizes 12 and 18 NOTE: 24V Interface compatible with all the sizes except sizes 12 and 58. Starting with Serial Number 1419V10001 the sizes 12 and 58 are shipped with the compatible control board. Indoor Units Fig. 3 — Condensate Pump Accessory On the console fan coils, the condensate pump has a lift capability of 12 ft. (3.6 m) on the discharge side with the pump mounted in the fan coil or 6 ft. (1.8 m) on the suction side if the pump is remote mounted. The pump is recommended when an adequate drain line pitch cannot be provided, or when the condensate must move up to exit. 4 Specifications subject to change without notice. 40MBFQ-03PD DIMENSIONS 1.00 (25) Drain pipe Hanging arm 1 8.27 (210) Unit: in (mm) Fig. 4 — Indoor Unit 12K UNIT SIZE 12K DEPTH IN (MM) 8.27 (210) WIDTH IN (MM) 27.56 (700) HEIGHT IN (MM) 23.62 (600) WEIGHT -NET LB (KG.) 32.41 (14.7) 40MBFQ-03PD Specifications subject to change without notice. DIMENSIONS (CONT) 1.57in (40MM) Drain Discharge Port 4.7in (120MM) Outside Air Intake HANG c Co 1.3 in (33 mm) WI ARM WIDTH Fig. 5 — Indoor Unit Sizes 18K-58K 9 ANT PIPE HOLE E E 0 N N C W E E N N N R DEPTH UNIT SIZE 18K 24K 36K 48K 58K HEIGHT in (mm) 9.2 ) 9.25 (235) 9.25 (235) 9.25 (235) 9.25 (235) WIDTH in (mm) 42.05 (1068) 42.05 (1068) 50.59 (1285) 64.96 (1650) 64.96 (1650) DEPTH in (mm) 26.57 (675) 26.57 (675) 26.57 (675) 26.57 (675) 26.57 (675) WEIGHT- NET Ibs (kg) 55.12 (25) 58.42 (26.5) 69 (31.3) 83.78 (38) 110 (50) ARM WIDTH in (mm) 38.7in (983mm) 38.7in (983mm) 47.2in (1200mm) 62in (1565mm) 62in (1565mm) 6 Specifications subject to change without notice. 40MBFQ-03PD CLEARANCES j >_4in (100mm) mr, Fig. 6 — Clearance for 12K 40MBFQ-03PD Specifications subject to change without notice. SPECIFICATIONS EAT P MP SIZE 12 18 24 36 48 58 SYSTEM Indoor Model 40MBFQ12--3 4 BF -3 40MBFQ24 --- 3 40MBFQ36--3 40MBFQ48--3 40MBFQ58 --- 3 Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 208/230-1-60 208/230-1-60 2081230-1-60 2081230-1-60 208/230-1-60 Electrical power Supply Indoor unit powered from outdoor unit MCA A. 0.29 1.0 1.0 1.23 0.85 1.48 Wireless Remote Controller (°F/°C Convertible) Standard Standard Standard Standard Standard Standard Controls Wired Remote Controller (°F/°C Convertible) Optional Optional Optional Optional Optional Optional O erat- p Cooling Indoor DB Min - Max °F (°C) 63-90 (17-32) 63-90 (17-32) 63-90 (17-32) 63-90 (17-32) 63-90 (17-32) 63--90 (17-32) Ong Range Heating Indoor DB g Min -Max °F(°C) 32-86 (0-30) 32-86 (0-30) 32-86 (0-30) 32-86 (0-30) 32-86 (0-30) 32-86 (0-30) Pipe Connection Size - Liquid in (mm) 1/4 (6.35) 1/4 (6.35) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) Piping Pipe Connection Size - Suction in (mm) 1/2 (12.7) 1/2 (12.7) 5/8 (16) 5/8 (16) 5/8 (16) 3/4 (19) Face Area (sq. ft) Sq. Ft. 2.1 2.1 2.5 3.2 4.1 8.1 Indoor No. Rows 2 2 3 3 3 4 Coil Fins per inch 19 19 19 19 19 19 Circuits 2 2 7 9 8 12 Unit Width in (mm) 27.56 (700) 42.05 (1068) 42.05 (1068) 50.59 (1285) 64.96 (1650) 64.96 (1650) Unit Height in (mm) 23.62 (600) 26.57 (675) 26.57 (675) 9.25 (235) 9.25 (235) 9.25 (235) Unit Depth in (mm) 8.27 (210) 9.25 (235) 9.25 (235) 26.57 (675) 26.57 (675) 26.57 (675) Net Weight Ibs (kg) 32.41 (14.7) 55.12 (25) 58.42 (26.5) 69 (31.3) 83.78 (38) 110 (50) No. of Fan Speeds 3 3 3 3 3 3 Indoor Airflow (lowest to highest) CFM 220/250/280 420/485/550 600/710/760 638/917/1037 1000/1120/1350 796/1029/1385 Sound Pressure (lowest to highest) dB(A) 34/41/45 39/44/47 46/50/52 43/49/54 52/54/57 46/49/55 Air Throw Data ft(m) 23 (7) 26 (8) 26 (8) 33 (10) 39 (12) 39 (12) Moisture Removal Pint/h (L/h) 2.64 (1.25) 2.96 (1.4) 4.44 (2.1) 8.03 (3.8) 12.05 (5.7) 12.47 (5.9) Field Drain Pipe Size O.D. in (mm) 1 (25.4) 1 (25.4) 1 (25.4) 1 (25.4) 1 (25.4) 1 (25.4) *Performance may vary based on the compatible outdoor units. See the respective pages for performance data. COMPATIBILITY INDOOR UNIT 40MBFQ12 ... 3 40MBF018 --- 3 40MBFQ24 --- 3 40MBFQ36 --- 3 40MBFQ48 --- 3 40MBFQ58 --- 3 OUTDOOR UNIT SINGLE ZONE 38MAQB12R--3 38MAQB18R--3 38MAQB24R--3 38MBRQ36A--3 38MBRQ48A--3 38MBRQ58A--3 OUTDOOR UNIT MULTI -ZONE 38MGRQ18B--3 38MGRQ24C--3 38MGRQ30D--3 38MGRQ36D--3 38MGRQ48E--3 NOTE: Backward compatible with 38MAQ, 38MBQ single zone and 38MGQ multi -zone systems Specifications subject to change without notice. 40MBFQ-03PD APPLICATION DATA Unit Selection Select equipment to either match or is slightly less than the anticipated peak load. This provides better humidity control, fewer unit cycles, and less part -load operation. For units used in spaces with high sensible loads, base equipment selection on unit sensible load, not on total anticipated load. Adjust for anticipated room wet bulb temperature to avoid undersizing equipment. Unit Mounting (Indoor) Refer to the unit's installation instructions for further details. Unit leveling - For reliable operation, units should be level in all planes. Clearance - Provide adequate clearance for airflow (see figures 6 and 7). Unit location - Select a location which provides the best air circulation for the room. These units should be positioned on the floor, against the wall for the best air circulation. The unit return and discharge should not be obstructed by furniture, curtains, or anything which may cause unit short cycling or air recirculation. Place the unit in the middle of the selected wall (if possible). Use an outside wall, if available, to make piping easier, and place the unit so it faces the normal location of room occupants. Unit Mounting (Outdoor) Refer to the unit's Installation Instructions for further details. Do not install the indoor or outdoor units in a location with special environmental conditions. For those applications, contact your ductless representative. Mounting Template Refer to the unit's Installation Instructions for further details. The fan coil units are furnished with mounting to mark the location of the wiring, and refrigeration line hole locations. Support Adequate support must be provided to support the weight of all the fan coils. Refer to "DIMENSIONS" on page 5 and "SPECIFICATIONS" on page 8 for the fan coil weights, and the base unit dimensional drawings for the mounting brackets location. System Operating Conditions OPERATING RANGE MIN/MAX °F (°C) COOLING HEATING INDOOR DB 63 / 90 (17 / 32) 32 / 86 (0 / 30) INDOOR WB 59 / 84 (15 / 29) NOTE: Reference the Product Installation Instructions for more information. Drain Connections Install drains to meet the local sanitation codes. If adequate gravity drainage cannot be provided, the unit should be equipped with an accessory condensate pump. The console fan coil unit condensate pumps have a maximum lift of 10' (3.05 m). For the drain sizes, see "SPECIFICATIONS" on page 8. NOTE: Console fan coil units have internal condensate traps. A trap is not required. Refrigerant Lines General Refrigerant Line Sizing_ 1. The outdoor units are shipped with a full charge of R410A refrigerant. 2. Refrigerant lines should not be buried in the ground. If it is necessary to bury the lines, not more than 36-in (914 mm) should be buried. Provide a minimum 6-in (152 mm) vertical rise to the service valves to prevent refrigerant migration. 3. Both lines must be insulated. Use a minimum of 1/2-in. (12.7 mm) thick insulation. Closed -cell insulation is recommended in all long - line applications. 4. Special consideration should be given to isolating the interconnecting tubing from the building structure. Isolate the tubing so that vibration or noise is not transmitted into the structure. 40MBFQ-03PD Specifications subject to change without notice. 9 WIRING Wireless Remote Control All wires must be sized per NEC (National Electrical Code) or CEC (Canadian Electrical Code) and local codes. Use Electrical Data table MCA (minimum circuit amps) and MOCP (maximum over current protection) to correctly size the wires and the disconnect fuse or breakers respectively. Recommended Connection Method for Power and Communication Wiring: The main power is supplied to the outdoor unit. The field supplied 14/3 stranded wire with ground with a 600 volt insulation rating, power/ communication wiring from the outdoor unit to indoor unit consists of four (4) wires and provides the power for the indoor unit. Two wires are line voltage AC power, one is communication wiring (S) and the other is a ground wire. Wiring between indoor and outdoor unit is polarity sensitive. The use of BX wire is NOT recommended. If installed in a high Electromagnetic field (EMF) area and communication issues exists, a 14/2 stranded shielded wire can be used to replace L2 and (S) between outdoor unit and indoor unit landing the shield onto ground in the outdoor unit only. EQUIPMENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Wires should be sized based on NEC and local codes. EQUIPMENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Be sure to comply with local codes while running wire from the indoor unit to the outdoor unit. Every wire must be connected firmly. Loose wiring may cause the terminal to overheat or result in unit malfunction. A fire hazard may also exist. Ensure all wiring is tightly connected. No wire should touch the refrigerant tubing, compressor or any moving parts. Disconnecting means must be provided and shall be located within sight and readily accessible from the air conditioner. Connecting cable with conduit shall be routed through the hole in the conduit panel. CONTROL SYSTEM The unit is equipped with a microprocessor control to perform two functions: 1. Provide safety for the system 2. Control the system and provide optimum levels of comfort and efficiency. The main microprocessor is located on the control board of the fan coil unit (outdoor units have a microprocessor too) with thermistors located in the fan coil air inlet and on the indoor coil. Heat pump units have a thermistor on the outdoor coil. These thermistors monitor the system operation to maintain the unit within acceptable parameters and control the operating mode. Fig. 8 —Wireless remote control 1. A wireless remote control is supplied for system operation for system operation of all console units. 2. Each battery operated wireless (infrared) remote control may be used to control more than one unit. Wired Remote Control (OPTIONAL) •KSACNO101AAA (All Sizes) •KSACN0401AAA (Size 12) •KSACN0501AAA (Sizes 18-58) 1. Optional wired remote controller used for system operation of all console units. 2. Kit includes a wired remote controller and a connecting cable. NOTE: Extension wire available through RCD (KSACN0101AAA Part Number: 17401204001601; KSACN0401AAA & KSACN0501AAA Part Number: 17401204000769) 3. Connect the wire terminal between the remote controller and the indoor unit. 4. Display in 'For °C and temperature increments every 1 °F or every 1°C. Fig. 9 — KSACN0101AAA (Timer Function) Fig. 10 — KSACN0401AAA & KSACN0501AAA (7 Day Programmable) 24 INTERFACE KSAIC0301230 for 208-230V models Allows the Ductless System to be controlled using a Third Party Thermostat NOTE: 24V Interface compatible with all the sizes except sizes 12 and 58. Starting with Serial Number 1419VI0001 the sizes 12 and 58 are shipped with the compatible control board. 10 Specifications sublect to change without nofice. 40MBFQ-03PD AIRFLOW DATA SYSTEM SIZE 12K 18K 24K 36K 48K 58K HIGH 280 760 1,037 1,350 1,385 INDOOR (CFM) MEDIUM 250 485 710 917 1,120 1,029 LOW 220 420 600 638 1,000 796 SOUND PRESSURE SYSTEM SIZE 12K 18K 24K 36K 48K 58K COOLING OPERATION INDOOR SOUND dBa (UM/H) 34/41/45 39/44/47 46/50/52 43/49/54 52/54/57 46/49/55 PRESSURE HEATING OPERATION INDOOR SOUND dBa (UM/H) 34/41/45 37.8/41.3/44.4 41.4/46.1/50.2 43.3/46.5/49.6 42.3/49.6/53.4 38/44/51 PRESSURE SOUND PRESSURE TESTING METHOD Unit Outlet Microphone 3.3ft (1 m) E T Indoor Unit Fig. 11 — Sound Pressure Testing Method 40MBFQ-03PD Specifications subject to change without notice. I I ELECTRICAL DATA CONSOLE SIZE 12K 18K 24K 36K 48K 58K (2081230V) (2 (2081230V) (208/230V) (2081230V) (208/230V) FLA 0.21 1.11 1.11 1.36 0.94 1.2 INPUT W 66.6 100 100 130 98 210 RATED HP HP 0.027 0.075 0.075 0.156 0.122 0.218 'Permissible limits of the voltage range at which the unit will operate satisfactorily. LEGEND FLA- Full Load Amps FAN AND MOTOR SPECIFICATIONS SYSTEM SIZE 12K 18K 24K 36K 48K 58K (208.230V) (208-230V) (208.230V) (208-230V) (208-230V) (208-230V) material AS ASS ASS ASS ASS ASS INDOOR Type LX-370'80'8-7JN LX-154.162' 12-41J LX-154'162' 12-41J LX-154.162. 12-41J LX-154'162' 12-41J LX-154'162'1241J FAN Diameter inch 14.6 0.51 (154) 0.51 (154) 0.51 (154) 0.51 (154) 0.51 (154) Height inch 3.15 0.53 (162) 0.53 (162) 0.53 (162) 0.53 (162) 0.53 (162) Model RD-280-20-8A ZKFN-55-8-1 ZKFN-55-8-1 ZKFN-115-8-1 ZKFN-90-8-1 ZKFN-160-8-1-2 Type DC DC DC DC DC DC Phase 3 3 3 3 3 3 FLA 0.21 1.11 1.11 1.36 0.94 1.2 Insulation class E E E E E E Safe class IPXO IPXO IPXO IPXO IPXO IPXO INDOOR Input W 66.6 100 100 130 98 210 FAN MOTOR Output W 20 55 55 115 90' 160 Range enlf Amps 0.21±10% 1±10% 1±10% 1.23±10% 0.85±10% 1.48±10% Rated current Amps 0.21 1 1 1.23 0.85 1.48 Rated HP HP 0.027 0.075 0.075 0.156 0.122 0.218 Speed rev/min 730/680/580/520 950/850/750 950/850/750 1300/1150/800 1320/1200/1120 1350/1050/850 Rated RPM rev/min 1062 1300 1300 1350 1350 1350 Max. input W 66.6 130 130 150 98 155 12 Specifications subject to change without notice. 40MBFQ-03PD WIRING DIAGRAMS ------------------------------------------------------------------------------- I I , TO WIRE CONTROLLER WIRING DIAGRAM (INDOORUNIT)' SWITCHBOARD N DISPLAYBOARD i FUNCTION OF SWITCHES 0 � SWfrCH BOARD I I �j�oo1r!,NjjI7� ro�RN7 CN15 LCN10 51vlo LliJ LTSJ 1y10 i -p-Nlr----i TLTDSpJI ILIHrHJY„ I�}1 ,o I OFF OFF I � II rnd � I TEAIPADI MO/rAU FAN — IJl I I ISW II I I I I OFF OFF I X55 SW102 WQ �� �� �� tf 11 1! For Selling Fan Motor Control then No Power Request SW103 Wi 12 12 ON 1 2 Mode FANOFF LOW FAN SPEED SE FAN SPEED TERMINAL et ory Se Setting �/ For Setting Auto -Restart SWt ON Q t ON t Mode ACTIVE INACTIVE Factory Setting N I t-----II----- %PS J MAIN CONTROL BOARD FA ^ U EARTH Y/G Y/G 1 U SS L N —161 BlA K11RE x53 %PS xS1 %s2 %Pi %P2 xP3 xsn L1 L2 5 Q RT2 RT1 Ml M2 �M omu CODE PARTNAME CN1{N20 P.0 BOARD SOCKETS FAN INDOOR DC FAN MOTOR MI UPPER OUTLET SWING MOTOR M2 LOWER OUTLETSWINGMOTOR RT1 ROOM TEMPERATURE RT2 PIPETEMPERATURE XPIAP5 CONNECTORS XS1-XS5 CONNECTORS XT1 4WAYTERMINAL J1 JUMPER For Setting Down louver SW101 ON 1 F0_NFl 1 Mode INACTIVE ACTIVE Factory Setting NOTICE 1: 1 .................................... I ................................................. THE TYPE SELECTION AND MO/MU HAS BEEN SET I For outdoor owersupply.. For indoor owersU I BEFORE LEAVING THE FACTORY. ONLY A QUALIFIED p p PPY MAINTENANCE TECHNICIAN CAN MODIFY IT. I L1 L2 5 Q XT1 L1 L2 5 = XT1 I — - — - —MODULE- — - — - II I I TO WIRE ,I CN20 CONTROLLER I 1 POWER. NOTICE 2: II i I PLEASE CUTOFF TH EJ UMPER 11. IFYOU II JI CONNECTTHE NET MODULE 1 I TO OUTDOOR UNIT TO OUTDOOR UNIT i 1 — - — - — - — - — - — - I -------------------------- ---------------------------------------------------- Fig. 12 — Wiring Diagram Size 12 Indoor Unit Control Board CODE PART NAME CN1 Input: 230VAC High voltage Connection of the terminal CN2 Input: 230VAC High voltage Connection of the terminal CN3 Output: 24VDC Between CN2 Connection of the S signal CN6 Output: 12VDC Connection of the Lower outlet swing motor CN7 Output: 5VDC Connection of the Room and Pipe temperature CN10 Output: 12VDC Connection of the Display board CN13 Output: 12VDC Connection of the Upper outlet swing motor CN15 Output: 1-5VDC Connection of the Switch board CN16 Output: 320VDC Connection of the Fan high voltage CN20 Output: 5VDC Connection of the Net module CN23 Output: 1-12VDC Connection of the Remote switch 40MBFQ-03PD Specifications subject to change without notice. 13 WIRING DIAGRAMS (CONT) WIRING DIAGRAM (INDOOR UNIT) SW3 o e SW5 0 0 AUTO- RESTART ACTIVE MODE HEATING PRIORITY COOLING PRIORITY FACTORY FACTORY SETTING SETTING &1 E:1ht0 sws I XQ EM[CW oe ,1 CODE FACTORY to 3ETTIN0 EFuneaon Indoor Unit Control Board -------------------_---_--_-----------I --, .......... WHITE WHITE •. .......T r , �� .. -WHITE .. .. I NOTE:' I ,rnue I 1 3 I M I � z II - �I <a II YIGI DC MOTOR I` --- DRIVERMODLE I- OUT ER DRIVERDCMOTOR ___ I - - - - - - >t--WHITE 3 BLUE BUCK I--I_____m _____ 0M =' C i3 I SW2 Q e FAN MOTOR CONTROLTHEN FAN FAN NOPOWER OFF ON REQUEST FACTORY / SETTING V I ! .); AC MOTOR '••'-•• ....WHITE 4 �- ••'ORANGE i FAN/ i......i I AC MOTOR 1 This symbol Indicates the element is Optional, the actual shape prevails. S ov li CNTS PS j CNB - _: INDOOR UNIT i cN1s MAINBOARD L------ j CNT11CN2T -4e � I I CN24 � I 1 I z o 9z I I CN17 CN14 CNif T w I __ _, L------- �� CN10tCN10A) a Fig. 13 — Wiring Diagram - Si p YELLOW �i J Yf - FILTER -BOAR[ CN7 i BLACK(BLUE) c, RED BROWN ............................................... 18K alnd 24K -- ---------- RED, I 1 RED • I -------------- I 5 — .5 AM __. M-4 1- t ) VSWING / SWING ---- --- T--- L I NEWFAN ° I I T ........: I 1 5 I CONTROLLER 1 L_______ b� I 1 WATER LEVELSWRCH_I I 1 2 3 0 I I I TO OUTDOOR I FOR OUTDO OR S UPP Ln INDOOR UNIT CODE PART NAME CN9 Input: 230VAC High voltage connection of the terminal CN2 Input: 230VAC High voltage connection of the terminal CN3/CN26 Output: OVDC Connection of the earth CN5 Output: 0-5VDC Connection of the water level switch CN6 Output: 5VDC Connection of the room and pipe temperature CN8/CN18 Output: 320VDC High voltage connection of the reactor CN10 (CN10A) Output: 12VDC Connection of the display board CN11/CN14 Output: 230VAC High voltage connection of the new fan CN13 Output: 220VAC High voltage connection of the pump CN15 Output: 320VDC High voltage connection of the fan board CN19 Output: 5VDC Connection of the CCM CN21/CN22 Output 12VDC connection to the swing motor CN23 Output: 1-12VDC Connection of the remote switch CN24 Output 12VDC connection to the swing motor CN33 Output OV connection of the alarm CN40 Output 12VDC connection of the wire controller CN41 Output 24VDC between CN2 connection of the S signal 14 Specifications subject to change without notice. 40MBFQ-03PD WIRING DIAGRAMS (CONT) I I I 1 I I I Y/G I A /t I I— I I � I _ AC Motor I I I CN13 I DCMOTOR I DRIVERMODLE I CN3 I I 3 I --7 II YlG 1 M I Outer Driver I _ _ DCMolor— ON19 CN16 INDOOR UNIT MAINBOARD CN40 CN23 CN33 CN26 KD19 MW ON/OFF ALARM To CCM Comm.BusTooUtl To CCM Comm.BusTooUtl i Ao i IrL—LSI r-m eor CommBus C... � ] I I Remote O , I Control FeBitebeef Indoor Unit Control Board `GN22�J CN241 _ F Cal ling -Floor Type I j L CN11 N I II 1 ,I `— I`---------' ..-------- 1 CN6 r---1 I CN51r--- 1 I IIr�I 1 I III Srr C7 I 0 Q 1 Y/G } I C 1 BLACN N(L11 i i i 0 D I 0.E0 L(L1( I I I I Y/G Alarm I - I I I� W Fertile bead I '' - - oulp.1 I I I-----------'/ I_ 202044390124 Fig. 14 — Wiring Diagram - Size 36K -------------------- RED ° F Reactor RED =9 of I Wire I . 5 — . 5 —., :....... : VSWING i.......i SWING:.....: ---------I L-- PUMP_i DISPLAY 5 I TO WIRE I I BOARD I CONTROLLER I I I T2 BLACK MIDDLE PIPE TEMP. T1 WHITE ROOM TEMP. -----------------1 T2B 1 _ _ _ _ _ _ _OUTER PIPE TEMP._ C.S I ------------.' L(L1) Nllsl I i L(L7) N(L71 TO OUTDOOR UNIT POWER OR OUTDOOR POWER SUPPLY INDOOR UNIT CODE PART NAME CN1 Input: 230VAC High voltage connection of the terminal CN2 Input: 230VAC High voltage connection of the terminal CN3/CN26 Output: OVDC Connection of the earth CN5 Output: 0-5VDC Connection of the water level switch CN6 Output: 5VDC Connection of the room and pipe temperature CN8/CN18 Output: 320VDC High voltage connection of the reactor CN10 (CN10A) Output: 12VDC Connection of the display board CN11/CN14 Output: 230VAC High voltage connection of the new fan CN13 Output: 220VAC High voltage connection of the pump CN15 Output: 320VDC High voltage connection of the fan board CN19 Output: 5VDC Connection of the CCM CN21/CN22 Output 12VDC connection to the swing motor CN23 Output: 1-12VDC Connection of the remote switch CN24 Output 12VDC connection to the swing motor CN28 Output 24VDC between CN2 connection of the S signal CN33 Output OV connection of the alarm CN40 Output 12VDC connection of the wire controller 40MBFQ-03PD Specifications subject to change without notice. 15 WIRING DIAGRAMS (CONT) ------- - -- I Outer Drivor DC Motor I Y/GI M ; I l_J I I---------- I 3 I FAN2 INDOOR UNIT MAINBOARD I CN8 j CN18 --- CN21 ICN22 u-I RED RED -------------------a 5 a I a Reactor Wire , I 5 :.......; IL A M ;,,•,,,; I CN3 I DC MOTOR 5 ......... I......... DRIVER , n CN24 5 M ' M CN13 5 Z CellIng•FloorType vs i.....i SWING:t•• ••% I — ---I ---- ---------- I I CN131 N -------- ....... �------.- '1 I j CN 44 CN11 5 11 L CN13 z I DC MOTOR N `- - �`- -------- NEWFAN__'r `__ PUMP_; DRIVER MODLE CN3 FAN1 — — 10 DISPLAY 5 I TO WIRE CN10(CN10A) BOARD I CONTROLLER � 3 I I_ _ CN6 `---------I T2 IY/G I BLACK MIDDLE PIPE TEMP. I CN29 CN28 L7 _ -J Outer Driver F m m CN40 z CN23 CN33 CN26 U U '--'1 ICN5 I---- --WHITE TI ROOM TEMP. ----------I DC Motor m m 5 m 0$ --- m� m G1ml KDIQ 1 1 Z T2B I II ONIOFF ALARM �! !�U OUTERPIPETEMP._� LJ < i C.S Y/G TO CCM I O I I I 1 I I I r f— BUCK N(LZ) L(L1) N1L2) L(L1) R(L1) Comm.Bp9 I yo I I�I I I I 0 0 RED L(Lt) Y/G _ To outdoor , m� I Remote Alarm I e I Ferrite bead Comm.Bua If U I z I Control Output I I i TO OUTDOOR UNIT pOWER I I I J 202044790381 I FOR OUTDOOR POWER SUPPLYFerntebead .......................A ............................ I Fig. 15 — Wiring Diagram - Size 48K Indoor Unit Control Board INDOOR UNIT CODE PART NAME CN1 Input: 230VAC High voltage connection of the terminal CN2 Input: 230VAC High voltage connection of the terminal CN3/CN26 Output: OVDC Connection of the earth CN5 Output: 0-5VDC Connection of the water level switch CN6 Output: 5VDC Connection of the room and pipe temperature CN7 Output 5VDC connection of the indoor coil outlet temperature sensor T213 CN8/CN18 Output: 320VDC High voltage connection of the reactor CN10 (CN10A) Output: 12VDC Connection of the display board CN11/CN14 Output: 230VAC High voltage connection of the new fan CN13 Output: 220VAC High voltage connection of the pump CN15/CN 16 Output: 320VDC High voltage connection of the fan board CN21/CN22 Output 12VDC connection to the swing motor CN23 Output: 1-12VDC Connection of the remote switch CN24 Output 12VDC connection to the swing motor CN29 Output: 5VDC Connection of the CCM CN33 Output OV connection of the alarm CN40 Output 12VDC connection of the wire controller CN41 Output 24VDC between CN2 connection of the S signal 16 Specifications subject to change without notice. 40MBFQ-03PD WIRING DIAGRAMS (CONT) FOR ANTI -COLD WIND HEATING S W 1 tzt to to t■ TELO 24i 15i 8i EEPROU d$W FACTORY SETTING FOR SETTING FAN QUANTLTY 8W4 Q t e t MODE Single Double Fen Fen Factory Setting Indoor Unit Control Board T r____ ____________ INDOOR UNIT MAINBOARD I REDe Gelling -Floor Type CN3 1 CN18 RED e I Reactor 1 OC MOTOR ` — — — — — — — — — — — — — — DRIVER MODLE CN21ICN22 rO — — — 5 5 I� A CN73 5 Z IVI r1 t_ U d z I CN 33 5 Z DC MOTOR U DRIVER MODLE It CN29 CN28 _— VSWING1— i CN13 i I � j CN14 CN11 E I I r"""" I E t I ° .....' L NEWFAN ;...... .* I_ _ 2 PUMP I CN10/CN10A 10 DISPLAY 51 TO WIRE BOARD � CnNTRni I F o,; CN23 CCN33 x1 I®I®I M19 — ON/OFF ALARM T2 BLACK INDOOR COIL TEMP. SENSOR T1 _ _ _VdILEL ROOM TEMP. SENSOR Z T2B L _ _ OUTER PIPE TEMP. SENSOR 1 _ r u I CJa� rc Magnetic ®®rII I m or Ring Y/GRC L(LI ( tWG W 111 I 1 t cN�CN r _________ __ __ ____ L .• � I S z I 3 L(LI 1:(L1) � IALI g(I.t Remote Alarm �m Control Output O I A. To CCM ComCM us Magnetic —, CN O CN i g I Ring ' — I IMagnetic _ 1 _ _ Ntagnet NOTE _ _ Ringg nG To outdoor This symbol indicates the element Is : To Outdoor I To Outdoor Ring Comm.Bus optional. The actual shape prevails. I For Separate I For Outdoor Power Supply Power SunolY Fig. 16 — Wiring Diagram - Size 58K INDOOR UNIT CODE PARTNAME CN1 Input: 230VAC High voltage connection of the terminal CN2 Input: 230VAC High voltage connection of the terminal CN3/CN26 Output: OVDC Connection of the earth CN5 Output: 0-5VDC Connection of the water level switch CN6 Output: 5VDC Connection of the room and pipe temperature CN7 Output 5VDC connection of the indoor coil outlet temperature sensor T26 CN8/CN18 Output: 320VDC High voltage connection of the reactor CN10 (CN10A) Output: 12VDC Connection of the display board CN11/CN14 Output: 230VAC High voltage connection of the new fan CN13 Output: 220VAC High voltage connection of the pump CN15/CN16 Output: 320VDC High voltage connection of the fan board CN21/CN22 Output 12VDC connection to the swing motor CN23 Output: 1-12VDC Connection of the remote switch CN24 Output 12VDC connection to the swing motor CN28 Output 24VDC between CN2 connection of the S signal CN29 Output: 5VDC Connection of the CCM CN33 Output OV connection of the alarm CN40 Output 12VDC connection of the wire controller 40MBFQ-03PD Specifications subject to change without notice. 17 GUIDE SPECIFICATIONS Part 1- GENERAL 1.01 System Description Indoor console, direct -expansion fan coils are matched with a cooling only or heat pump outdoor unit. 1.02 Agency Listings Unit is rated per AHRI Standards 210/240 and listed in the AHRI directory as a matched system. 1.03 Delivery, Storage, And Handling Units are stored and handled per the unit manufacturer's recommendations. 1.04 Warranty(For Inclusion By Specifying Engineer) Part 2 - PRODUCTS 2.01 Equipment A. General: Indoor, direct -expansion, floor -mounted fan coil. Unit is complete with a cooling/heating coil, fan, fan motor, piping connectors, electrical controls, microprocessor control system, and integral temperature sensing. Unit is furnished with an integral mounting bracket and mounting hardware. B. Unit Cabinet: Cabinet discharge and inlet grilles are attractively styled, high - impact polystyrene. Cabinet is fully insulated for improved thermal and acoustic performance. C. Fans: 1. Fan is the tangential direct -drive blower type with an air intake in the center of the unit and discharge at the top and bottom front. An automatic, motor -driven vertical air sweep is provided standard. 2. Air sweep operation is user selectable. The vertical sweep may be adjusted (using the remote control) and the horizontal air direction may be set manually. D. Coil: Coil is a copper tube with aluminum fins and galvanized steel tube sheets. Fins are bonded to the tubes by mechanical expansion and specially hydrophilic pre -coated for enhanced wet -ability. A drip pan under the coil has a drain connection for hose attachment to remove condensate. The condensate pan has an internal trap. E. Motors: The motors have an open drip -proof, permanently lubricated ball bearing with inherent overload protection. The fan motors are 4-speed. F. Controls: Controls consist of a microprocessor -based control system which controls the space temperature, determines the optimum fan speed, and rums self diagnostics. The temperature control ranges from 62°F to 86°F (17°C to 30°C) in increments of 1°F or VC, and have 460F Heating Mode (Heating Setback). The wireless remote controller has the ability to act as the temperature sensing location for room comfort. INDOOR CONSOLE DUCTLESS UNITS Size Range: 1 to 5 Ton Nominal Cooling and Heating Capacity Model Number:40MBFQ The unit has the following functions as a minimum: 1. An automatic restart after power failure at the same operating conditions as at failure. 2. A timer function to provide a minimum 24-hour timer cycle for system Auto Start/Stop. 3. Temperature -sensing controls to sense the return air temperature. 4. Indoor coil freeze protection. 5. Wireless infrared remote control to enter set points and operating conditions. 6. Automatic air sweep control to provide on or off activation of air sweep louvers. 7. Dehumidification mode to provide increased latent removal capability by modulating system operation and set point temperature. 8. Fan -only operation to provide room air circulation when no cooling is required. 9. Diagnostics to conduct continuous checks of unit operation and warn of possible malfunctions. Error messages appear on the unit. 10. Fan speed control is user -selectable: high, medium, low, or microprocessor controlled automatic operation during all operating modes. 11. Automatic heating -to -cooling changeover in heat pump mode. Control includes a deadband to prevent rapid mode cycling between heating and cooling. 12. Indoor coil high temperature protection is provided to detect excessive indoor discharge temperature when the unit is in heat pump mode. G. Filters: Unit has a filter track with factory -supplied cleanable filters. H. Electrical Requirements: Indoor fan motor to operate on 208-230V as specified. Power is supplied from the outdoor unit. I. Operating Characteristics: The 40MBFQ system has a minimum SEER (Seasonal Energy Efficiency Ratio) and HSPF at AHRI conditions, as listed on the specifications table. J. Refrigerant Lines: All units should have refrigerant lines that can be oriented to connect from the left, right or back of unit. Both refrigerant lines need to be insulated. K Special Features (Field Installed): Condensate Pump: The condensate pump removes condensate from the drain pan when gravity drainage cannot be used. The pump is designed for quiet operation. The pump consists of two parts: an internal reservoir/sensor assembly, and a remote sound - shielded pump assembly. A liquid level sensor in the reservoir stops the cooling operation if the liquid level in the reservoir is unacceptable. 2019 Carrier Corporation • 3300 Rlverwood Parkway Atlanta GA, 30339 Edition Date: 05/19 Catalog No. 40MBFO-03PD Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without Incurring obligations. Replaces: 40MBFQ-02PD