REVIEWED BLD2023-0353+DOOR INFO.17.2023_7.49.27_AM+3427061
RECEIVED Mar 22 2023 BLD2023-0353 CITY OF EDMONDS DEVELOPMENT SERVICES DEPALAMRENCE 111111010] r. +:f REVIEWED BY CITY OF EDMONDS LRUD Job#: 02-M4051-23 CUSTOMER Davis Door Service Inc. JOB NAME: Stevens Health Care Review all instructions completely before attempting installation {Refer to details as shown in installation instructions) Door Mark Quant Door Width Door Nei ht Model Operation Hand E-Guide Heels Z-Guide Heels Initial Turns A 1 4-0 3 - 41/2 CLFP-PG Push -Up Left 4 - 4 1/2 N/A 6.8 -+- - -- I, -E GUIDE HEELS DOOR WIDTH (UP TO TIP) �— HEELS DOOR WIDTH — - {fIP TO TIP) GUIDE HEELS DOOR WIDTH (TIP (DP TO TIP) GUIDE HEELS �- ,—z GUIDE HEELS GUIDE HEELS DOOR WIDTH WIDTH mPOTIP) (TIP TO TIP) DOOR WIDTH (TIP TO TIP) LANRENCE Z6I01My f - - / i PUSH-UP OPERATION ;5 -- TENSION (To 12' wide, 8' high, 84 sq. ft.) ADJUSTING A1HEEL VV Left hand operation is RELEASE ►. a as shown - right hand ------.._._.._._......_ !PUSH-UP T operation is opposite GNL'r';i Elevation and section shown are for typical ;;UIpE face mount doors CURTAIN COIL SIDE OPPOSITE COIL SIDE SLIDE LOCK i T M CRANK OPERATION MOTOR OPERATION � � 12' -�AS 112°- i ?., rVIS 12" V o i 1— T - T J "AUTO -RESET" INCREASES HEIGHT OF OPERATORS BY APPROXIMATELY Y GUIDE DETAILS I Face Mount Between Jamb Mount CURTAIN & BOTTOM BAR DETAILS e) F-Stat Angle Tubular 2" x 9116" Bottom Bar Bottom Bar (Optional) CLEARANCES To 4' « 4112" 4112" 4 112" 4 112" Over 4' to T' 5" 5" 5" 5" Over 7' to 16' 5 112" 5112" 5112" 5112" For face mount to non -masonry jambs with more than 1 layer of drywall, With 2 layers, add 112" to dimensions With 3 layers, add 1" to dimensions For face mount to masonry jambs, add 3/4" to dimensions. For between jamb mount, deduct 114" from dimensions. Use the over T to 18' cfearances for 4-hour rated doors. D 'V' (Bracket Size Dimensions- 0 10, Includes Expansion Clearance) 0 8, 3° R 12 1/2" 6' E 4' 10 112 2' G 0' H 0' 2' 4' 6' 8' 10' 12' 14. 16' T DOOR WIDTH Bottom Bar T Angle 2" Tubular 3" GENERAL NOTES: Clearanoes are based upon standard door construction. Reduced clearances may be available. Some options may require additional clearance. Shop drawings for specific applications are available. Consult factory for any information not shown. 02017 Lawrence Roll -Up Doors, Inc., Lawrence Roll -Up Doors, Inc. reserves the right to change specifications without notice or obligation. GL-11117 L/44W�RENCE �•z.I.] rby Model. Doors STANDARD• UL File No. R2820 [FM Approved] CSFM Listing No. 3515-1587:100 PART 1GENERAL 1.01 SUMMARY A. Model CL Counter Fire Doors sliali be rranufact ured by Lawrence Roll -Up Doors. Inc 1.02 SYSTEM DESCRIPTION A. Doors shall be approved for .tse _sr servir: c:r urners and other smaller openings up to 16 4 oxide, t 0 -0" high, 120 sq. ft. B. Doors shall be designed for 101n00 cycle- .tsage: C. Doors shall be fire rated .Ap r, :i 1,11 noi,;rt ;n rwr, masonry or masonry wall construction. 1.03 QUALITY ASSURANCE A. Doors shall be Underwriters Laboratories c;=assitied and certified for Canada [FM Approved], and listed by the California State Fire Marshal (CSFM). Doors shall he pmvided ulth a r. iJl_ us [Frvi] label or oversize door label as dictated by door size. [Air leakage rated smoke door assemblies shall be provided -,rith a sl-pjAnlr:Fntai 5-1_2bel.] 1.04 WARRANTY A. Doors shall be warranted against defec:ta r: workmanship and materials for one year iron: date of shipment, provided designed cycle life is not exceeded_ Factory finishes are ex-1wied iron warranty. PART 2 PRODUCTS 2,01 MATERIALS A. Curtain shall be assembled from interlock,ng Type F (2" x 9116") flat slats, roll -formed from 22 gauge galvanized steel or stainless steel —"-"-�ilr�E"KCIIticK fl'alliie i�J 7f t2S iiCS 6 ii5 end wide. a. Bottom bar shall be formed by one 2" x 2' x 11B" steel or stainless steel angle attached to bottom of curtain. Provision shall be made for thermal expansion at assembly bolts. C. Guides shall be 11 gauge steel or stainless steel shapes, sized to retain curtain and support door. Guides shall be assembled with 1/4" minimum bolts no more than 12" on center and attached to wall with 318" minimum bolts no more than 24" on center. Provision shall be made for thermal expansion at assembly and wall bolts. Removable curtain stops shall be provided. D. Barrel shall be 4 1/2" diameter steel pipe, sized to contain counterbalance assembly and support curtain with a maximum deflection of 0.03" per ft. of width. Counterbalance assembly shall consist of torsion spring(s) and fittings mounted to a continuous cold finished steel shaft. Grease packed sealed bearings shall be used to support each end of counterbalance assembly. Spring tension shall be adjustable by adjusting wheel outside bracket. E. Brackets shall be 3116" steel plates bolted to guides. Plates shall be sized to support curtain and barrel and provided with 118" flanges for hood attachment. Bracket on operator side shall be fitted with a grease packed sealed bearing. F. Hood shall be formed from 24 gauge galvanized steel or stainless steel sheet with top and bottom reinforcements to reduce deflection. Intermediate support shall be provided on doors over 13'-6" wide. G. Operation of doors shall be: • Push up operated with directional speed governor and single side release on doors to 12'-D" wide, 8'-0" high, 84 sq. ft. • "Easy -Reset" ]"Auto-Resen [tubular (in -barrel)] awning crank with internal release and governor on larger doors, removable handle to Imp— 'l-4 tr �In r,.^.,,';^^,I push-upoperated doors, "Auto -Reset" and tubular optonal on all doors). • "Easy -Reset" Model FGRL ["Auto Reset" Model FSML] inline gear drive motor operator with internal release and govemor, integral lock sensor to prevent door opening with locks engaged, UL Listed, mounted horizontally in front of and parallel to door coil and not requiring additional clearance above top of coil, with wall mount 3-button open -close -stop control station requiring constant pressure to close, NEMA 1 enclosures (optional on all doors). • Model FTS "Auto -Reset" tubular motor operator, UL Listed, concealed inside of barrel and not requiring additional clearance in front of coil, separate wall mount control panel, with wall mount 3-button.open-dose-stop control station requiring constant pressure to close, NEMA 1 enclosures (optional on all doors — eliminates the need for counterbalance assembly and spring tension adjustment). NOTE: When momentary pressure close is required, or control is not within line of sight of the door, a monitored sensing edge on the bottom bar, or monitored reflective sensor on the guide, is required to reverse the door upon sensing an obstruction in the opening. NOTE: For ease of operation, crank or motor operator is recommended on doors over 7'-O" high (or if top of opening is more than 7'-0" above the floor) and operated regularly, or when doors are operated over a deep counter or other obstruction making push-up operation difficult. H. Automatic closing of doors shall be thermally activated by 165 deg. F. fusible links. Average closing speed shall be approximately 9" to 12" per second, but no less than 6" nor more than 24" per second perthe requirements of NFPA-80. "Easy -Reset" operators shall be designed to automatically close door without a loss of spring tension, and reset by reconnecting fusible link cable and reopening door ["Auto -Reset" operators shall be designed to automatically close door upon power loss or alarm without a loss of spring tension, and reset by restoring power or clearing alarm and reopening door]. NOTE. For ease of drop -test and reset, Easy -Reset" or "Auto -Reset" crank or motor operator is recommended on all doors. I. Locking shall be by slide locks coil side on bottom bar of push-up and awning wrank operated doors. NOTE. Motor operators provide self-locking gear reduction = if slide locks are required on motor operated doors, a motor operator with internal lock sensor, or guide mounted electrical interlocks, are required to prevent opening door with locks engaged. 2.02 FINISHES A. _ Galvanized steel slats and hood shall have a baked -on primer and grey polyester top coat- Steel bottom, bar, guides and brackets shall be shop painted with a black color rust -inhibiting primer. Stainless steel slats, bottom bar, guides and hood shall have a brushed finish. PART 3 EXECUTION 3.01 INSTALLATION A. Doors shall be installed in accordance with Lawrence Roll -Up Doors, Inc. installation instructions and NFPA-80. 3.02 FIELD QUALITY CONTROL A. Doors shall be tested for proper operation and full closure at time of installation. A written record shall be maintained. 3.03 SCHEDULES A. Doors shall be maintained, inspected and tested in accordance with NFPA-80. Brackets [ I denote an available option. CL-2123 Lawrence Roll -Up Doors, Inc. reserves the right to change specifications without notice or obligation- © 2023 Lawrence Rort-Up Doors, Inc. DRYWALL CONSTRUCTION JAMB SCHEDULE Model SL, ML or HL Fire Doors 1 Model IL Insulated Fire Doors OPENING WIDTH METAL STUD WOOD STUD STEEL TUBE j to 8'-0" (1) 16 ga. x 2 1/2" (2) 2" x 4" 2 1/2" x 2 1/2" x 3116" over 8'-0" to 14'-0" (2) 16 ga. x 2 1/2" (2) 2" x 4" 2 1/2" x 2 112" x 3/16" . over 14'-0" to 20'-0" N/A (1) 4" x 4" 3" x 3" x 114" over 20'-0" to 28'-0" N/A (1) 4" x 6" 3 1/2" x 3 112" x 114" over 28'-0" to 36'-0" NIA (1) 4" x 6" -- 4" x 4" x 114" over 36'-0" to 40'-0" N/A (1) 6" x 6" 6" x 6" x 5/16" (2) 16 ga. studs are required for IL Insulated Fire Doors to 8'-0" wide Model CL Counter Fire Doors OPENING WIDTH METAL STUD WOOD STUD STEEL TUBE to T-0" (1) 16 ga. x 2 1/2" (2) 2" x 4" 2 1/2" x 2 1/2" x 3/16" over T-0" to 16'-0" (2) 16 ga_ x 2 1/2" (2) 2" x 4" 2 112" x 2 1/2" x 3/16" NOTES: 1) Above jambs are minimum requirements only —jambs and their attachments must be designed to provide proper mounting and adequate support for the size and weight of the door and its intended use. 2) This jamb schedule is only for jambs located inside of rated non -masonry wall construction with the fire door attached to the face of the wall or between the jambs. 3) Metal studs are not to be used as jambs in non -masonry wail construction rated over 2 hours. 4) When metal studs are used for between jamb mounted doors, they must be solid studs (un-punched, without knockouts). 5) Number of studs and width of steel tubes may need to be increased if guides are set back from edges of opening. 6) When jambs in existing walls are not in compliance with the above requirements, they must be replaced. As an alternative, independent tube supports provided by the fire door manufacturer as a part of the fire door assembly may be installed in front of the wall with the fire door face of wall or between jamb mounted, or guides and brackets direct attached, to the tube supports. EXPANSION SCHEDULE OPENING HEIGHT VERTICAL EXPANSION CLEARANCE ABOVE TOP OF DOOR COIL to 8'-0" 1/2" over 8'-0" to 12'-0" 3/4' over 12'-0" to 20'-0" 1" over 20'-0" to 28'-0" 1 1/4" over 28'-0" to 32'-0" 4 1/2" -6- L70024 FDICFD Install 11/22 © 2022 Lawrence Roll -Up Doors, Inc.