FIR2020-0057+Fire_Sprinkler_Equipment_Specification_Sheets+6.15.2020_12.06.42_PM
ES-A-2000B Job Name Job Location Engineer — Approval — Series 2000B Double Check Valve Assemblies Sizes:'/2" - 2" (15 - 5Omm) g/4" 2000B (20mm) !a q Features • Ease of maintenance with only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design • '/2" - 2" (15 - 50mm) Cast bronze body construction • Top mounted ball valve test cocks • Low pressure drop • No special tools required • '/2" - 1 " (15 - 25 mm) have tee handles It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material prod- uct, consult your local water authority, building and plumbing codes. Contractor Approval Contractor's P.O. No. Representative 2" 2000B HC (50mm) Series 2000E Double Check Valve Assemblies are designed to protect drinking water supplies for dangerous cross -connections in accordance with national plumbing codes and water authority requirements for non -health -hazard non - potable service applications such as irrigation, fire line, or industrial processing. These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Specifications A Double Check Valve Assembly shall be installed at each noted location. The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated isolation valves and four top mounted, resilient seated test cocks. The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by the Foundation for Cross - Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be an Ames Company Series 2000B. The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety informa- tion before beginning the installation of this product. Ames Fire & Waterworks product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measure- ments, please contact Ames Fire & Waterworks Technical Service. Ames Fire & Waterworks reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire & Waterworks products previously or subsequently sold. A WATTS Brand Available Models Suffix: B - Quarter turn ball valves LBV - less ball valves SH - stainless steel ball valve handles HC - 21/2" inlet/outlet fire hydrant fitting (2" valve) Pressure — Temperature Temperature Range: 33°F — 140°F (0.5°C — 60°C) Maximum Working Pressure: 175psi (12.1 bar) Dimensions - Weights Standards AWWA Std. C510, IAPMO PS31 ,!Site Approvals G CP ®oC U� uS us 1015 B64.5 3/4" - 2" (LBV Models Only) • Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. (Excluding all LBV Models) • Horizontal and vertical "flow up" approval on all sizes. Suffix HC — Fire Hydrant Fittings dimension "A" = 231/2" (594mm) i 10 G 10 SIZE (ON) DIMENSIONS WEIGHT in. mm in. A mm B in. mm in. C mm in. F mm G in. mm H in. mm I in. mm lbs. kgs. 1/2 15 10 254 46/a 117 2'/6 62 5 127 3% 85 26/6 59 21/16 52 4.5 2 3/4 20 111/6 282 4 102 31/6 79 63/16 157 3'/6 87 21/8 54 16/6 33 5 2.3 1 25 131/4 337 51/8 130 4 102 71/2 191 33/8 85 111/16 43 111/16 43 12 5.4 11/4 32 16% 416 5 127 36/6 84 91/2 241 5 127 3 76 2 50 15 6.8 11/2 40 163/4 425 4'/8 124 31/2 89 93/4 248 513/16 148 31/8 79 211/16 68 15.86 7.2 2 50 191/2 495 1 61/4 159 4 102 1 133/s 340 1 61/6 156 1 37/ 6 87 1 211/16 68 1 25.75 11.7 Strainer sold separately Capacities As compiled from documented Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California lab tests. ATypical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) kPa psi 112" (15mm) y 83 12 0 69 10 55 8 3 41 6 N 28 4 (D 14 2 (L 0 0 0 2 4 6 8 10 12 gpm OP 0 7.6 15.2 22.8 30.4 38 45.6 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps Flow Rate kPa psi y 152 22 J 124 18 i 96 14 7 y 69 10 a 41 6 14 2 n 314" (20mm) OP 0 5 10 15 26 25 30 35 40 45 50 gpm 0 19 38 57 76 95 114 133 152 171 190 Ipm 7.5 15 fps 2.3 4.6 mps Flow Rate kPa psi a 1114" (32mm) 96 14 N 83 12 o 69 10 y 55 8 3 41 6 y 28 4 a 14 2 0 0 AP 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 111211 (40mm) 83 12 y 69 10 0 55 8 y 41 6 28 4 fyil 14 2 0 0 L pp0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate N N kPa psi 1 " (25mm) N J N 110 16 o 0 83 12 i y 69 10 H 55 8 y 41 6 14 28 4 a i a 14 2 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm AP 0 19 38 57 76 95 114 133 152 171 190 209 228 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate A WATTS Brand ES-A-200013 1735 kPa psi " (50mm) 83 12 Q 69 10 55 8 41 6 28 4 14 2 0 0 0 25 50 75 100 125 150 175 200 gpm AP 0 95 190 285 380 475 570 665 760 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate USA: Backflow T: (978) 689-6066 • F: (978) 975-8350 • AmesFireWater.com USA: Control Valves T: (713) 943-0688 • F: (713) 944-9445 • AmesFireWater.com Canada: T: (905) 332-4090 • F: (905) 332-7068 • AmesFireWater.ca Latin America: T: (52) 81-1001-8600 • AmesFireWater.com © 2017 Ames Fire & Waterworks TFP963 Page 8 of 8 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name, including description and part number (P/N). Riser Manifolds Specify: Size (specify) Connection Type (specify inlet x outlet) Model RM-1 Riser Manifold, P/N (specify): Commercial 1-1/2 Inch (DN40) MT x FT ............. 40551 2 Inch (DN50) G x G..................40601 2-1/2 Inch (DN65) G x G............... 40611 3 Inch (DN80) G x G..................40621 4 Inch (DN100) G x G ................. 40651 6 Inch (DN150) G x G ................. 40661 Residential 1 Inch (DN25) FT x FT ................ 40671 1-1/2 Inch (DN40) MT x FT ............. 40571 2 Inch (DN50) G x G.................. 40591 Optional 175 psi Pressure Relief Kit Specify: Pressure Relief Kit, Model RM-1 Riser Manifold, (specify Commer- cial or Residential application), (specify size range), P/N (specify): Commercial 1-1/2-3 Inch (DN40-DN80)............ 40721 4-6 Inch (DN100-DN150)............. 40731 Residential 1 -2 Inch (DN25-DN50)............... 40711 Replacement Parts Specify: Model RM-1 Riser Manifold (specify part description), P/N (specify from Figures 1, 2, 3, 4 or 5) GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright © 2017 Tyco Fire Products, LP. All rights reserved. t[�CO TEFLON is a registered trademark of DuPont Fire Protection Products Model 8000/8011 RESIDENTIAL RISERPACK TM Pre -Assembled TESTANDRAIN° Riser Sizes: 1 " 11/a" 11/z" 211 The AGF RESIDENTIAL RIsERPACKTM Model 8000/8011 is a prepackaged economical riser assembly designed for NFPA 13D and 13R residential fire sprinkler systems. The one-piece casting provides required NFPA signage on both sides allowing for left or right installation and are available with grooved, threaded, or thread x groove ends. Threaded ends allow for easy connection to metal or plastic piping systems and grooved ends use approved rubber gasket couplings for secure connections. • Complies with NFPA requiements regarding testing through a properly sized test orifice • 1 " Models are available to meet nominal K-factor requirements of 2.8 to 5.6 • 1 " 8000 Models utilize a 3/a" ball valve with patented TESTANDRAIN® orifice specific outlet designed to accept either a standard garden hose or hard piped drain line • 11/a", 11/2", and 2" Models are available with orifices to meet K-factors of 2.8 to 11.2 • 11/a", 11/2", and 2" 8000 Models utilize a UL Listed/FM Approved Model 3011 BV INSPECTOR'sTESTT" ball valve • Cast and machined bronze made in the U.S.A. • Includes UL Listed/FM Approved AGF Model 7500 Pressure Gauge (300 PSI); 13R Models also include Model 7600 3-Way Globe Valve • Available as the Model 8011 with UL Listed/FM Approved Model 7000 Pressure Relief Valve (11/a"-2") or Model 7200 Pressure Relief Valve (1 ") designed to provide relief, test, and drain through a single valve %11 7/s" 1/2" 17/s2", and W (ELO) orifice sizes • Larger size risers are available on special order NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. SS-M8000M8011N002 • 01/15 TESTANDRAIN® and REMOTETESTO are registered trademarks of AGF Manufacturing Inc. i " Mnrinl Qnnn V I.. IN,I wwll ..7 i " Mnrinl sini i Model SIZE A B C D 1 101/2 121/4" 43/4 ' 61/4" (267 mm) (311 mm) (121 mm) (159 mm) 0 1 1 a 11 " 121/4" ** 4" 61/2" 000 (279 mm) (311 mm) (102 mm) (165 mm) 0 1 1 /2" 12" 121/2" ** I 41/8" 65/8" (305 mm) (317 mm) (105 mm) (168 mm) 2" 12" 13" 43/8" 67/8" (305 mm) (329 mm) (111 mm) (174 mm) 101/2 121/4" 27/8" *** 61/4" 1 (267 mm) (317 mm) (73 mm) (159 mm) 0 11/a" 143/a" 15" 4" 61/2" ao (375 mm) (381 mm) (102 mm) (165 mm) 1 /2 151/a" 151/4" 41/8" 65/8" (387 mm) (387 mm) (105 mm) (168 mm) 2" 151/a" 153/4 43/8" 67/8" (387 mm) (399 mm) (111 mm) (174 mm) *Additional space may be necessary to allow for hard drain fitting if required **Valve handle clearance required - add 2" ***Lift handle clearance required - add 31/8" n �1n MADE IN U.S.A. AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone:610-240-4900 Fax:610-240-4906 www.testandrain.com Model 8000/8011 RESIDENTIAL RISERPACKTM 11/4"-2" Model 8000 1'/4"-2" Model 8011 e 4 8 10 ms� - 5 3 3 A e 14 16 1—p 12 17 16 13( 15 C — Item No. Part Oty. 1 RiserPACK - Bronze Casting 1 2 3/a" Male x Female Ball Valve 1 3 1 " M3011 BV INSPECTOR'sTEST Valve 1 M7500 Pressure Gauge (1/a" 3-Way Globe Valve Included for 1313 Systems Only) 1 5 Water Flow Alarm Switch 1 3/4" MNPT x 1/2" FNPT Hose Adaptor Orifice 1 7 M7200 3/a" Pressure Relief Valve 1 8 M70001/2" Pressure Relief Valve 1 9 1 " Brass Nipple 1 10 1 " Brass Street Elbow 1 11 1/2" Brass System Access Port Plug 1 12 1 " Relief Valve Bypass Nipple 1 13 1 " Relief Valve Bypass Tee 1 14 1/2" NPT x-Barb Straight Fitting 1 15 1/2" NPT x-Barb Elbow Fitting 1 16 Clamps 2 17 Nylobraid Relief Valve Drain Tubing 1 Job Name: Architect: Engineer: Contractor: Page 1 of 5 FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking Freedom") Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass -bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire -protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre -assembled with a threaded adapter for installation with a low -profile small -diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push -on", "thread -off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL- US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS e@us UL Listed (C-UL-US-EU): Category VKKW eu Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass -bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-051000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom° Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 200 °F (93 °C) = E For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Form No. F_012116 17.04.20 Rev 17.2 Replaces Form No. F_012116 Rev 17.1 (added alt. material for yoke) Page 2 of 5 FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = MA, Painted Black = M-/B Temperature Suffix: 135 °F/57 °C = A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches": A. Heavy Duty Part No. 14047W/B** (available since 2006), or B. Head Cabinet Wrench Part No. 14031 *** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a ''/2' ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly.. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres- sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Sprinkler Maximum Temperature Rating Cover Large Square Temperature Nominal Ambient of the Cover Plate Cover Plate Cover Plate Bulb Color Classification Temperature Ceiling Assembly Base Part Base Part Base Part Rating' Temperature2 (Required)' Number° Number° Number° Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C) 13504 13642 15394 Red Intermediate 200 °F (93 °C) 150 °F (65 °C) 135 °F (57 °C) 13504 13642 15394 Green Sprinkler Finishes: Brass and ENT Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings5: ENT Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Maximum ambient temperature for cover assembly is 100 °F (38 °C). ° Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. Form No. F_012116 17.04.20 Rev 17.2 Page 3 of 5 FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart Viking VK494, 4.9 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Wor- Part Number 1 SIN king Pressure Inches mm U.S. metric 2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) Max. Coverage 6 Flow GPM Pressure Listings and Minimum Area (LPM) PSI(bar) Deflector to Installation Approvals3,s Spacing Ceiling Type Ft. 155 °F (68 °C), 200 °F (93 °C) Temperature ` p °S Ft. X Ft. (m) (m X m) Rated Sprinklers Eo 12 X 12 13 7.0 (3.7 X 3.7) (49.2) (0.48) 14 X 14 13 7.0 (4.3 X 4.3) (49.2) (0.48) Refer to Figure 2 Concealed with Cover Plate See Footnotes 7,10, & 11 8 16 X 16 13 7.0 (4.9 X 4.9) (49.2) (0.48) Assembly. See Footnote 9. (2.4) 18 X 18 17 12.0 (5.5 X 5.5) (64.4) (0.83) 20 X 20 20 16.7 (6.1 X 6.1) (75.7) (1.15) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4 Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. 5 Meets New York City requirements, effective July 1, 2008. 6 For areas of coverage smaller than shown, use the "Flow' and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow' and "Pressure" used. Cover Temperature Rating is 135 °F (57 °C). Cover Part No. 135041, 136421 (large diameter), or 15394' (square cover plate). 9 Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 0 Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 1. " C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) Form No. F_012116 17.04.20 Rev 17.2 Page 4 of 5 FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listing Reguirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT. Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Sprinkler Wrench Part No. 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. 2-1/4" (57 mm) diameter opening required in the ceiling. Step 2: 1 1 Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler wrench flat Figure 1: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Sprinkler frame arms Form No. F_012116 17.04.20 Rev 17.2 Page 5 of 5 FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1/2" (15 mm) NPT E N co S 2-9/16" (65 mm) Maximum NOTE: Upon sprinkler activation, the deflector descends to approximately 13116" (21 mm) below the sprinkler body. 2-1/16" (52 mm) Minimum Figure 2: Sprinkler Dimensions and Cover Installation QQ�\�--p C USTO�A a �2 O C) v� O VIKING0. All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 3: Identification of Custom Paint for Concealed Covers 2-3/4" (70 mm) or 3-5/16" (84 mm) - -1 - \- . .... ., Figure 4: Square Cover Assembly 15394 Form No. F_012116 17.04.20 Rev 17.2 Replaces Form No. F_012116 Rev 17.1 (added alt. material for yoke) Page 1 of 7 ® MIRAGE° STANDARD AND N41 Ki1 QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking Mirage° Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass -bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre -assembled with a threaded adapter for installation with a low -profile cover assembly that provides up to '/2" (12.7 mm) of vertical adjustment. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push -on", "thread -off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is listed and approved as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS c&os cULus Listed: Category VNIV <FM> FM Approval: Class 2015 vds NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 `PCB''' LPCB Approved: Ref. No. 096e/12 E CE Certified: Standard EN 12259-1, EC -certificate of conformity 0832-CPD-2032 China Approval: Approved according to China GB Standard Refer to the Approval Charts and Design Criteria listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)' Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric—) Glass -bulb fluid temperature rated to -65°F (-55°C) Patents Pending cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). "Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler; Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-C11000 or Stainless Steel UNS-S30400 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: The sprinkler and cover plate must be ordered separately. Refer to Tables 1 and 2. Form No. F_103005 20.02.19 Rev 20.2 Replaces Form No. F_103005 Rev 20.1 (Revised approval specifications for 21356A.) WARNING: Cancer and Reproductive Harm- www.P65Warnings.ca.gov Page 2 of 7 ® MIRAGE° STANDARD AND N41 Ki1 QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip -cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: SPRINKLER ORDERING INFORMATION Instructions: Using the sprinkler base part number, .. the suffix for the desired Finish Size .. the suffix for the desired Temperature Rating. (3) Select a cover plate (See Table 2) 1: Finishes 2: Temperature Ratings Sprinkler SIN Base Part NPT BSPT Sprinkler Max. Ambient Number' Inch Description Suffix' Temperature Nominal Rating Bulb Color Ceiling Suffix mm Classification Temperaturez VK462 13503 1/2 -- Brass A Oridinary 155 °F (68 °C) Red 100 °F (38 °C) B VK462 2135679 -- 15 ENT 3,4 JN Intermediate 175 °F (79 °C) Yellow 150 OF (65 °C) D VK4631 13667 1/2 -- Intermediate 200 °F (93 °C) Green 150 °F (65 °C) E Example:13503AE _ 200 °F (93 °C) Temperature Rated Sprinkler with a standard Brass finish. Accessories Sprinkler Wrenches and tools (see Figure 1): A. Heavy Duty Part Number: 14047W/B5 (available since 2006) B. Head Cabinet Wrench Part Number: 140316 (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part Number: 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) Sprinkler Cabinet: Holds up to 6 sprinklers: Part number 01731A (available since 1971). Footnotes Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. s. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. UL Listed as corrosion resistant. a. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. s. Requires a 'h" ratchet (not available from Viking). B. Also optional for removal of the protective cap. Ideal for sprinkler cabinets. 7 Not available with ENT finish. See approval charts for more information. B. See approval charts for more information. 9. Approved according to China GB Standard. Form No. F_103005 20.02.19 Rev 20.2 Page 3 of 7 ® MIRAGE° STANDARD AND N41 Ki1 QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com COVERTABLE 2: Using .. the ORDERING INFORMATION plateInstructions: the cover base part number, suffix for the desired.. the suffix for the required 1: Finishes Cover Plate Nominal Rating. Temperature Rating Matrix' z Cover Style Cover Plate Sprinkler Nominal Sprinkler Plate Size Base Part Inch (mm) Description Suffix5 Nominal a Rating /Temperature Max. Ambient Suffix Number' Rating Classification Ceiling (Required) 1 Temperature z 23190 2-3/4(70) Round Polished Chrome F 135 -F (57 -C) Ui 155 °F (68 °C) / ORD 100 °F (38 °C) A 23174 3-5/16 (84) Round Brushed Chrome F-/B 139 °F (59 °C) FM 23179 3-5/16 (84) Square Bright Brass B 165 °F (74 °C) 175 °F (79 °C) / INT 150 °F (65 °C) C 231934 2-3/4 (70) SST Antique Brass B-/A 165 °F (74 °C) 200 °F (93 °C) / INT 150 °F (65 °C) I C 231834 3-5/16 (84)1 SST Brushed Brass B-/B Example: 23190MCIW = Brushed Copper E-/B Painted White M-/W 165 °F (74 °C) Temperature Rated 2-3/4" (70 mm) Diameter Round Cover Plate with a Painted White finish. Painted Ivory M-/I Painted Black M-/B Footnotes 1 The sprinkler temperature rating is stamped on the deflector. z. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 4. Stainless Steel versions are not available with any finishes or paint. 5. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. Q\��p CUSTO �A O 0 U� O \y 45 All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers 3-5/16" (84 mm) Figure 2: Square Cover Assembly Form No. F_103005 20.02.19 Rev 20.2 Page 4 of 7 ® MIRAGE° STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart 1 (UL) SpnnklerTemperature Rating Cover Plate Temperature Rating Mirage° Concealed Pendent Sprinklers VK462 and VK463 AW1t Cover Plate Finish KEY Sprinkler Thread Size Nominal K-factor Maximum Listings and Approvals° (Refer also to Design Criteria) Base Part SIN Water Working NPT Inch BSPT mm U.S. metriez cULuss NYC VdS' LPC13 a ` China Approval No.' Pressure Standard Response Applications 13503A VK462 1/2" 5.6 80.6 175 psi (12 bar) AY1, CZ1 AY1, BZ1 AY1, CZ13 21356Al2 VK462 15 5.6 80.6 175 psi (12 bar) — AY1, CZ1 Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1, AS2, BT2 AV1, BX16 — — 13503JN11 VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1, AS2, BT2 AV1, BX16 — — 21356Al2 VK462 -- 15 5.6 80.6 175 psi (12 bar) AY1, CZ1 - — — 13667A VK463 1/2" 15 5.6 80.6 250 psi (17.2 bar)' AV1, BX1 AV1, BX16 13667JN11 VK463 1/2" 15 5.6 80.6 250 psi (17.2 bar)' AV1, BX1 AV1, BX16 Approved Sprinkler Approved Cover Plate Temperature Rating Codes Approved Cover Plate Finish Codes Temperature Rating Codes S - 135 °F (57 °C) cover 23193 or 23183 (large diameter) A = 155 °F (68 °C) T - 165 °F (74 °C) cover 23193 or 23183 (large diameter) °F °C) 1 - Polished Chrome, Brushed Chrome, B = 175 °F (79 °C) V - 135 (57 cULus Listed cover 23190, 23174 (large diameter), Bright Brass, Antique Brass, Brushed or 23179 (square cover plate) Brass, Brushed Copper, Painted White, C = 200 °F (93 °C) X - 165 °F (74 °C) cover 23190, or 23174 (large diameter) Painted Ivory, or Painted Black Y - 135 °F (57 °C) cover 23190 LPCB Approved as 139 °F (59 °C) 2 - Stainless Steel Z - 165 °F (74 °C) cover 23190 Footnotes 1. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. The Water Working Pressure rating is stamped on the deflector. 4. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5. Listed by Underwriter's Laboratories for use in the U.S. and Canada. e. Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. 7. VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 +A1:2001 +A2:2004 +A3:2006, Certificate G4080021. 9. CE Certified, Standard EN 12259-1, EC -certificate of conformity 0832-CPD-2032. 9. The 135/139 °F cover has an orange label. The 165 °F (74 °C) cover has a white label. 10.Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 11•cULus Listed as corrosion resistant. 12.Approved according to China GB Standard. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Form No. F_103005 20.02.19 Rev 20.2 Page 5 of 7 ® MIRAGE° STANDARD AND N41 Ki1 QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1) cULus Listing Requirements: Mirage° Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. • For hazard occupancies up to and including Ordinary Hazard, Group II. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). • Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. • Minimum distance from walls is 4 in. (102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Approval Reauirements: a) The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. b) This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. c) Follow installation guidelines of current standards, CEA4001VdS and EN12845. These sprinklers can only be installed in LH and OH occupan- cies, except in OH4. NOTES: Due to the design the sprinkler type 'Domed-CCP' shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type 'Domed-CCP' shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: 1. Prepare the sprinkler key. 2. Remove the plastic cover. 3. Hold the sprinkler with the wrench and fasten it. 4. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT. Always refer to Bulletin Form No. F 091699 - Care and Handling of Sprinklers. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 20.02.19 Rev 20.2 Page 6 of 7 ® MIRAGE° STANDARD AND N41 Ki1 QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart 2 (FM) Sprinkler Temperature Rating Cover Plate Temperature Rating Mirage® Standard Response Concealed Pendent Sprinkler VK462 AW1t Cover Plate Finish KEY Sprinkler Base Thread Size Nominal K-Factor Maximum FM Approvals3 Part No.' SIN Water Working (Refer also to Design Criteria below.) NPT BSPT U.S. metric' Pressure Inch mm 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AW1, BX1,AY2, BZ2 21356A6 VK462 15 5.6 80.6 175 psi (12 bar) AU1, CV1 Approved Sprinkler Temperature Approved Cover Plate Temperature Rating Codes Approved Cover Plate Finish Codes Rating Codes U - 139 °F (59 °C) cover 23190 V - 165 °F (74 °C) cover 23190 W - 139 °F (59 °C) cover 23190, 23174 (large diameter), 1 - Polished Chrome, Brushed Chrome, Bright A - 155 °F (68 -C) or 23179 (square cover plate) Brass, Antique Brass, Brushed Brass, B - 175 °F (79 °C) and 200 °F (93 °C) X - 165 °F (74 °C) cover 23190, 23174 (large diameter), or Brushed Copper, Painted White, Painted C - 200 -F (93 °C) 23179 (square cover plate) Ivory, or Painted Black Y - 139 °F (59 °C) cover, 23183 or 23193 2 - Stainless Steel Z - 165 °F (74 °C) cover 23183 or 23193 Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. s. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4. The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. 5. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. e. Approved according to China GB Standard. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Reauirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non -Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 20.02.19 Rev 20.2 Page 7 of 7 ® MIRAGE° STANDARD AND N4 I Ki QR CONCEALED PENDENT SPRINKLER VK462 AND HP 0 SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins Sprinkler Wrench Part No. 14047W/B** diameter opening required in the ceiling. Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. NEVER install the sprinkler by applying the installation Sprinkler -= wrench across the frame arms. DO NOT overtighten. wrench flat�',� Use only the designated sprinkler *wrenches, VikingSprinkler Part Numbers 14047W/B * or 14031 . A leak tight seal frame arms should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) 1/2" (15 mm) NPT Maximum Minimum Fo E T E ` M Lo N - _ 2-3/4" (70 mm) or _ NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16" (21 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_103005 20.02.19 Rev 20.2 Replaces Form No. F_103005 Rev 20.1 (Revised approval specifications for 21356A.) �.A ■1 - om mu FIFE SPRINKLER CORPORATION QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE HORIZONTAL SIDEWALL RECESSED HORIZONTAL SIDEWALL DESCRIPTION AND OPERATION The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary horizontal pipe nipples. The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector, in an approved discharge pattern. It can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. TECHNICAL DATA • See reverse side for Approvals and Specifications. • Temperature Ratings - 135T (57°C), 1550F (680C), 1750F (790C), 200OF (930C), 2860F (141 °C). • Water Working Pressure Rating - 175 psi (12 Bars). • Factory tested hydrostatically to 500 psi (34 Bars). • Maximum low temperature glass bulb rating is -670F (-55(C). • Frame - bronze • Deflector - brass • Screw - brass • Bulb seat - brass • Spring - teflon coated nickel alloy • Retainer - brass • Pin - stainless steel • Torsion spring - stainless steel • Bulb - glass with alcohol based solution, 3mm • Orifice insert - brass • 3/4" NPT or 1" NPT • Outer tube - galvanized steel pipe • Inner tube - stainless steel QUICK RESPONSE DRY NON-ADJUSTABLE HORIZONTAL SIDEWALL QUICK RESPONSE DRY SLEEVE & SKIRT HORIZONTAL SIDEWALL QUICK RESPONSE DRY RECESSED HORIZONTAL SIDEWALL SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER N.F.P.A. MAXIMUM CLASSIFICATION BULB COLOR TEMPERATURES CEILING TEMPERATURE ORDINARY 135°F/155°F 57°C/68°C ORANGE/RED 100°F 38°C INTERMEDIATE 175°F/200°F 79°C/93°C YELLOW/GREEN 150°F 66°C HIGH 286°F 141 °C BLUE 225°F 107°C 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX 989-846-9231 JULY 2010 A-58 BULLETIN GL5641, REV. #14 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE SPECIFICATIONS NOMINAL "K' FACTOR THREAD SIZE LENGTH FINISHES cULus Factory Bronze 5.6 (80 metric) 3/4" or 1" NPT Variable to 1 Satin Chrome 48" Bright Chrome FM White Polyester 8.1 (116 metric) 1" NPT Variable to Black Polyester Lead Coated NOTE: Metric Conversions are approximate. cULus listed corrosion resistant: Polyester must be specified on order. APPROVALS 'Finishes available on special order. 'Lead Coated is UL approved only. STYLE SIN CODE K FACTOR THREAD SIZE 135°F 570C 155°F 680C 175°F 79°C 200°F 930C 286°FFM 141°C * cULus GL5641 5.6a 1" NPT X X X X X X X HORIZONTAL SIDEWALL GL5642 5.6a 3/4" NPT X X X X X X GL8141 8.1b 1" NPT X X X X X X RECESSED GL5641 5.6a 1" NPT X X X X X X X HORIZONTAL GL5642 5.6a 3/4" NPT X X X X X - X SIDEWALL GL8141 8.1b 1" NPT X X X X X X NOTE: 'Listed for light hazard only with deflector from 4"-12" below the ceiling. 'Listed for light and ordinary hazard with deflector from 4"-12" below the ceiling. 'Recessed Horizontal Sidewall - FM Approved 155'F and 200OF only. `Horizontal Sidewall - FM Approved 155'F, 200'F, and 286°F only. CROSS SECTIONS �rE 4 L� r EXTENDED HORIZONTAL SIDEWALL NON-ADJUSTABLE HORIZONTAL SIDEWALL GL613E FIRE SPRINKLER CORPORATION RECESSED HORIZONTAL SIDEWALL IMPORTANT INSTALLATION DATA Globe GL Series Dry Horizontal Sidewall sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately18". Excessive force may distort the frame thus destroying the unit. When installed in a wet system extending into a freezing area see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs. Please refer to our Dry Caution sheet for further important installation data. ORDERING INFORMATION SPECIFY • Quantity • Model Number • Style • Orifice • Temperature • Finishes desired • Quantity - Wrenches - P/N 333010 • Quantity - Recessed Wrenches - P/N 337014 • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed) • Escutcheons desired • "A" Dimension - Distance from face of fitting to the finished ceiling regardless of escutcheon used. ocE "A MNJ GLOBES PRODUCT WARRANTY ` 121 I—' :". Globe agrees to repair or replace any of its own manufactured SLEEVE & SKIRT products found to be defective in material or workmanship for a HORIZONTAL SIDEWALL period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com JULY2010 PRINTED U.S.A. BULLETIN GL5641, REV. #14