APPROVED BLD WSEC ENVELOPE BLD2019-0951over Project Address 23830 Edmonds Way Date 07/26/2019 Occupancy Group CCommercial O Group R For Building Department Use Fenestration Area as % gross above -grade wall area 9.8% Max. Target: 30.0% Skylight Area as % gross roof area Max. Target: 5.0% Vertical Fenestration Alternates: None Selected on ENV -SUM Prescriptive compliance of envelope assemblies may be accomplished by providing insulation R-values per Table C402.2 or U-factors/F-factors per Tables C-402.1.2 and C-402.3. A single project may comply via R-values for some envelope assemblies and U-factors/F-factors for others. Note compliance method taken for each assembly in spaces provided. Building Component U-Facto r/F-Factor for Alternative R-Value for Prescriptive Compliance Prescriptive Compliance Alternate Cl U-Factor Source Continuous R-Value (Appendix A,Chapter 3 Cavity Ins. Ins. (CI) (Table C402.2 Assembly table, or approved Provide page/plan # of assembly detail and ID. R-Value R-Value Footnote F)' U-Factor calculation method) Y ID: a°i ID: ID: a ID: °o m ID: ID: ID:A40, Roof System 1 0.019 calculation m ID:A40,Roof System 2 0.019 calculation O ID: ID: ID: ° ID: a ° a ID: — m_ I D: m ID: ID:A40, Wall Systems 1 6 3 0.033 calculation aS °o ID:A40, Wall Systems 2 6 4 0.033 calculation n ID: O ID: PLAN REVIEW ACCEPTANCE ID: ID: FOR COMPLIANCE WITH THE APPLICABLE CONSTRUCTION CODES IDENTIFIED BELOW. ° ID: o ID: ® BUILDING ® STRUCTURAL ® MECHANICAL ® PLUMBING m @ ID: ❑ ELECTRICAL ® ENERGY C� ID: ® ACCESSIBILITY ❑ FIRE ID: N PLAN REVIEW ACCEPTANCE OF DOCUMENTS c6 ID: DOES NOT AUTHORIZE CONSTRUCTION TO 2 ID: PROCEED IN VIOLATION OF ANY FEDERAL, o 0 STATE, OR LOCAL REGULATIONS. ° ID: LL BY: DATE:07/29/2020 E ID: m u- ID: WEST COAS CODE CONSULTANTS, INC. Perim. Ins. Full Slab Cl R-Value R-Value F-Factor F-Factor Source ID:A40, Floor System 2 15.0 -0m m ° s ID: a c ID: ° a a� ID: ° m ID: = ID: ..w . - va,..v "m arc ,"Jv"cv. , - w v,—wa-ac..uv". coca v ,..� a Pc"m .., " ,, ,, vuyn v...... ,.. a,. ..- ,,.-.-.,..,...�. Note 2 - Thermal spacer blocking and liner system are required for prescriptive R-Value compliance. Note 3 - Intermediate framing is required for prescriptive R-Value compliance in wood -framed wall assemblies. Note 4 - Proposed non-residential building CMU walls meeting Table C402.1.2 Footnote D requirements can enter the target U-value of 0.104. Note 5 - Refer to Table C402.2, Footnote E for prescriptive R-Value requirement for steel floor joist assemblies. Note 6 - Prescriptive slab -on -grade insulation shall extend from top of slab to minimum length per an approved method as defined in C402.2.6. over Project Address 23830 Edmonds way Date 07/26/2019 Fenestration Area as % gross above -grade wall area 9. 8% Max. Target: 30.0% For Building Department Use Skylight Area as % gross roof area Max. Target: 5.0% Notes: 1: If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target Area Adjustment of all applicable envelope elements will be calculated by the compliance form. Refer to Target Area Adjustment worksheet for this calculation. 2: Provide U-factor for the fenestration assembly, which is the combination of frame and glazing performance. BuildingComponent 1� U-Facto r/F-Factor for Alternative R-Value for Prescriptive Compliance Prescriptive Compliance Alternate Cl U-Factor Source Continuous R-Value (Appendix A, Chapter 3 Cavity Ins. Ins. (CI) (Table C402.2 Assembly table, or approved Provide page/plan # of assembly detail and ID. R-Value R-Value Footnote F) U-Factor calculation method) 0 ID:A80,WD1 0.370 Appendix A 0 ID: Cn 0 ID: n 0 = E ID: 0 ID: ID: Solar Heat Gain Coefficient (SHGC) U-Factor for Prescriptive Compliance SHGC Projection Adjustment U-Factor Source factor (PF) Multiplier (if Assembly Assembly (NFRC, Appendix A, or (if applicable) applicable) SHGC U-Factor Chapter 3 table) m ID:A81, Window Types 0.28 0.29 Appendix A 2 ID: c� ID: 0 z ID: c a °' ID: 0w ID: ID: � 0 am � ID: LL a ID: ° ID: r j m ID: ID: ID: ID: aai ID: ID: ID: ID: li ID: ID: Note 1 - SHGC Adjustment Multiplier based on calculated Projection Factor. Refer to Equation C4-2 Projection Factor Calculation and Table C402.3.3.1 for corresponding SHGC Multiplier. Refrigerated Spaces, Walk-in & Warehouse Coolers Notes R-Values for Prescriptive Compliance Prescriptive U-Factor not allowed. Walls Ceiling Doors Freezers Walls Ceiling Doors Floor Building Permit Plans Checklist, •• 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Address 23830 Edmonds Way Date 7/26/19 The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy Code, Commercial Provisions. Applicability Code Location in Building Department (yes,no,na) Section Component Compliance information required in permit documents Documents Notes SCOPE na C101.5.2 Low energy spaces Low energy spaces identified on plans na C101.5.2.1 C402.1.4 Semi -heated spaces Semi -heated spaces identified on plans na C402.5 Cooler and freezer Walk-in and refrigerated warehouse cooler and freezer spaces identified on plans C402.6 spaces na C101.4.6 Mixed occupancy Spaces with different occupancy requirements identified on plans na C101.4.4 Change of occupancy/space Existing F, S and U-occupancy building spaces undergoing a change of occupancy C101.4.5 conditioning or space conditioning that require compliance are identified on plans ENVELOPE PROVISIONS yes C303.1 Insulation identification Indicate identification mark shall be applied to all insulation materials A05 C303.1.3 Fenestration product Fenestration products shall be labeled with rated U-factor, SHGC, VT, and yes C402.4.3 rating leakage rating A81 Indicate installation methods, thicknesses, densities and clearances to achieve the C303.1.1 General insulation intended R-value of all insulation materials; yes C402.2 installation Where two or more layers of rigid insulation will be used, indicate that edge joints between layers are staggered A40 Indicate R-value(s) of cavity/continuous insulation on roof sections; Indicate framing materials on roof sections; Roof assembly Indicate method of framing for ceilings below vented attics and vaulted ceilings per yes C402.2.1 insulation A102.2 (std, adv); Provide area -weighted calculations for sloped insulation installed entirely above deck; Indicate R-values for thermal spacers and each insulation layer, and liner system LS method for metal building roofs A40 na C402.2.1 Skylight curb Indicate curb insulation R-value on roof section if not included in skylight NFRC insulation rating Indicate R-value(s) of cavity/continuous insulation on wall sections; Indicate framing materials on wall sections; Indicate method of framing for wood const per A103.2 (std, int, adv); C402.2.3 yes C402.2.4 Above/below grade wall insulation Indicate mass of masonry walls; C303.2.1 Indicate loose -fill core insulation material, percentage of cores filled, and frequency of grouted cores and bond beams for masonry walls; Indicate method of protection of exposed exterior basement/crawlspace wall Insulation A40, A41, A47 Walk-in/refrigerated Indicate insulation R-values of ceilings, walls, doors, floors on sections; Indicate method of minimizing door infiltration; na C402.5 C402.6 warehouse cooler and freezer insulation Indicate type(s) of transparent doors and windows yes C402.2.7 Opaque doors Indicate rated U-factor (swinging) or R-value (roll-up/sliding) on wall sections - applies to doors with less than 50 /o glazed area ASO Floor over outdoor or Indicate R-value(s) of cavity/continuous insulation on floor sections; Indicate framing material on floor sections; yes C402.2.5 unconditioned space insulation A45 Indicate mass of masonry floors Indicate R-value of continuous insulation on wall section or foundation detail; C402.2.6 Slab -on -grade floor Indicate insulation extends down vertically and/or horizontally the required distance yes C303.2.1 insulation from top of slab; Indicate method of protection of exposed exterior slab edge insulation A40, A47 Indicate R-value of continuous insulation on wall section or foundation detail; na C402.2.6 Radiantly heated slab- on -grade floor Indicate insulation extends down vertically from top of slab and then horizontally C303.2.1 insulation under the entire slab; Indicate method of protection of exposed exterior slab edge insulation na C402.2.8 tRadiant heating Indicate insulation R-value behind radiant panels, U-bend/headers and bottom stem insulation surface of radiantly heated floors other than radiantly heated slab -on -grade) Building Permit Plans Checklist, •• 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Address 23830 Edmonds Way Date 7/26/19 Applicability Code Location in Building Department (yes,no,na) Section Component Compliance information required in permit documents Documents Notes C402.3.1 Vertical fenestration Provide calculation for total vertical fenestration area as percentage of gross above yes maximum area grade wall area A04 na C402.3.1.2 Skylight maximum Provide calculation for total skylight area as percentage of gross roof area area Indicate U-factors, SHGC and VT values in fenestration schedules; C402.3.3 U-factors, SHGC and An area -weighted U-value may be used for all fenestration elements that qualify yes C402.3.1.3 VT for all fenestration within the same fenestration category per Table C402.3; C303.1.3 assemblies Indicate if values are NFRC or default. If default then specify frame type, glazing layers, gap width, low-e coatings, as -fill. A81 Increased max. Provide calculations showing that percentage of overall conditioned floor area in C402.3.1.1 vertical fenestration the daylight zone is equal to or greater than 50%; Indicate method of daylighting control in lighting equipment schedules; Chap. 2 area with daylighting Definition controls Indicate VT of vertical fenestration is at least 1.1 times the rated SHGC Increased max. vertical fenestration Indicate high performance U-factors and SHGC values in fenestration schedules; na C402.3.1.2 area with high- An area -weighted U-value may be used for all fenestration elements that qualify within the same fenestration category er this section C402.3.3 Permanent shading Provide projection factor calculations (Equation C4-2) and associated SHGC C402.3.3.1 devices multipliers for north and non -north orientations Provide calculations for percentage of conditioned floor area located within a skylight daylight zone; Provide calculations for percentage of skylight area to daylight zone under na C402.3.2 Single story spaces skylights, OR; requiring skylights Provide calculations for percentage of overall skylight effective aperture (Equation C4-1); Indicate haze factor of skylight glazing material or diffuser AIR LEAKAGE C402.4.1.1 Air barrier construction Indicate location of continuous air barrier on plans and sections; yes C402.4.2 and sealing Provide details for all joints, transitions in materials, penetrations in air barrier and note method of sealing caulked, gasketed, or other approved method A05 Indicate locations of all stairway and shaft vents; na C402.4.5.1 Stairway and shaft Provide leakage rating of motorized dampers in mechanical equipment schedules; vents Indicate method of emergency operation - activation of fire alarm or interruption of power Outdoor air intakes, Indicate locations of all outside air intakes, exhausts and relief outlets, including yes C402.4.5.2 exhausts and relief those integral to mechanical equipment; Provide in mechanical equipment schedules leakage rating of dampers, identify openings whether motorized or gravity, and note any exceptions taken A81 na C402.4.8 Recessed lighting in Indicate IC rating of fixtures in lighting equipment schedules; Indicate method of sealing between light fixture housing and wall or ceiling building envelope na C402.4.6 Loading dock seals Indicate weather seal at cargo and loading dock doors Indicate locations and dimensions of vestibules; na C402.4.7 Vestibules For unconditioned vestibules, indicate which envelope assembly (interior or exterior) complies with the requirements for a conditioned space Indicate air barrier test method in accordance with ASTM E779 or approved equivalent; C402.4 - Air barrier building Include the following requirements in project documents: (1) air barrier test report yes test shall be submitted to jurisdiction once test is completed; (2) if test results exceed .1.2.3 0.4 cfm/ft2 at 0.3 in. wg then visually inspect air barrier and seal noted sources of leakage; (3) submit a follow-up report to jurisdiction noting corrective measures taken A05 If "no" is selected for any question, provide explanation: End of Building Permit Plans Checklist