APPROVED BLD WSEC LTG BLD2019-09512015 Washinqton State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Info Project Title: Edmonds Crossing Apartments Date 7/26/19 Compliance forms do not Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Department Use require a password to Company Name: Haynes Wilson Lund Architects LLC Company Address: 385 101st Avenue SE, Bellevue WA 98004 use. Instructional and calculating Applicant Name: Haynes Lund cells are write- protected. Applicant Phone: 425-643-3921 Applicant Email: hwlarch@comcast.net Project Description 2 New Building [Addition [ Alteration C No Lighting Scope Include PROJ-SUM form (included in envelope forms workbook) with lighting compliance forms. Interior Lighting System General lighting to be ceiling mounted recessed LED downlights with supplementary wall Description sconsces in bathrooms. ® Interior Lighting Plans Included Interior Lighting Power ® Building Area Method El Space -by -space Method Allowance Method Select method used in project. Interior Lighting Controls ® All C405.2.1 - C405.2.8 Lighting Controls CC405.2 Exception 5 Luminaire Level Lighting Controls (LLLC) CAdditional Efficiency Package Option C406.4 Enhanced Digital Lighting Controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the required controls per C406.4. Dwelling Unit Interior Permanently installed interior lighting fixtures in dwelling units comply with: C No Dwelling Lighting C C405.2 thru C405.5 Commercial Lighting Controls and LPA Units CC406.3 High Efficacy Lighting C R404.1 Residential High Efficacy Lighting. Dwelling unit lighting complies with WSEC Residential provisions in lieu of WSEC Commercial provisions. Exterior Lighting System Description ® Exterior Lighting Plans Included Building Additions Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project Refer to Section C502.2.6 for additional requirements. Lighting systems in addition are combined with existing r L building lighting systems to demonstrate compliance Addition is combined with existing: For interior lighting projects, include new + existing -to -remain interior lighting fixture wattage in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. For exterior lighting projects, include new + existing -to -remain exterior fighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG-EXT form. PLAN REVIEW ACCEPTANCE FOR COMPLIANCE WITH THE APPLICABLE CONSTRUCTION CODES IDENTIFIED BELOW. ® BUILDING ® STRUCTURAL ® MECHANICAL ® PLUMBING ELECTRICAL ® ENERGY ® ACCESSIBILITY FIRE PLAN REVIEW ACCEPTANCE OF DOCUMENTS DOES NOT AUTHORIZE CONSTRUCTION TO PROCEED IN VIOLATION OF ANY FEDERAL, STATE, OR LOCAL REGULATIONS. BY: ��� DATE:07/29/2020 WEST COAS CODE CONSULTANTS, INC. Lighting Summary, cont. 2015 Washinqton State Enerqv Code Compliance Forms for Commercial Buildinqs includinq R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Edmonds Crossing Apartments Date 7/26/19 Change of Space Use Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting Lighting Alterations 50% or more of existing are replaced C C C Select all Lighting Power and Lighting Control elements that apply to the scope of Less than 50% of existing are replaced r L r L r L the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures are replaced in Lamp and/or ballast replacement only — existing total wattage not increased r L r L r L some spaces, and 50% or more of the fixtures are replaced in others, then 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed Lighting provide separate lighting power compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one lighting power compliance form. Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. 50% threshold applies to number of luminaires for interior spaces and parking garages, and total installed Refer to Section C503.6 for additional wattage for exterior luminaires. requirements. Lighting Controls Interior lighting Parking garage Exterior lighting All alteration lighting controls shall be commissioned per C408.3. New wiring installed to serve added fixtures and/or fixtures relocated to new r L r L r L circuit(s) New or moved lighting panel C C C Interior space is reconfigured - r luminaires unchanged or relocated only L New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting CNo changes are being made to the interior or exterior lighting systems and existing space uses controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. and configuration are not Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. changed. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. 2015 Washington State Enerav Code Compliance Forms for Commercial Buildings includina R2. R3. R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Edmonds Crossing Apartments Date 7/26/19 Calculation aew Construction C Addition - CAddition For Building Department Use Area NOTE 9 stand alone + existing paces where < 50% of Spaces where z 50% of Spaces where the Use uminaires are replaced luminaires are replaced is changing (C505) LPA /-- and CAdditional Efficiency Package Option Calculation C406.3 Reduced Interior Lighting Power User Note Type To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer C406.3 for to additional requirements. Maximum Allowed Li hting Wattage NOTE 1 Watts Allowed Location (plan #, Gross Interior Allowed (watts/ft2 x area) Building Area room #, or ALL) Area Description Area in ft2 Watts per ft2 NOTE 2 Multifamily A21, A70 Floor 1 dwelling units: 10, 11, 12, 13 & support 2895 0.41 1187 Multifamily A22 Floor 2 dwelling units: 21 ,22, 23 & storage 2516 0.41 1032 Multifamily IA23 Floor 3 dwelling units: 31, 32, 33 & storage 2516 0.41 1032 Total 7927 Proposed Lighting Wattage Building Area Location (plan #, room #) Fixture Description NOTE 3, 4, 5, 6 Number of Fixtures Watts ptil Fixture NOTE 7 Watts Proposed Multifamily A21, A70 recessed LED downlights 43 13 559 Multifamily A21, A70 bathroom wall sconce 5 14 70 Multifamily A22 recessed LED downlights 33 13 429 Multifamily A22 bathroom wall sconce 4 14 56 Multifamily A23 recessed LED downlights 33 13 429 Multifamily A23 bathroom wall sconce 4 14 56 Compliance by Building Area"" 8 Building Area Warnings Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance Multifamily Confirm all fixtures are reported under proposed lighting - low watts relative to maximum allowed. 3251 1599 COMPLIES Note 1 - List all unique building areas per Table C405.4.2(1) that occur in the Totals 3251 1 1599 project scope. Select building area category from drop down menu. Note 2 - Unfit Message - Enter lighting fixture information for this building area surface in Proposed Lighting Wattage table to generate Lighting Power Allowance. Note 3 - Proposed fixtures must be listed in the building area in which they occur. List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage tracklbusway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between Building Area types is not allowed under the Building Area Method compliance path. wore m - i.aIcwaoon Area UWaos: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Building Area types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Ruildina Area tvnes and arnss interim areas_ 2015 Washinqton State Energy Code Compliance Forms for Commercial Buildinqs includinq R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Edmonds Crossing Apartments Date 7 /2 6 / 19 Exterior Lighting Zone co Zone 1 OZone 2 CZone 3 O Zone 4 Exterior Lighting Zone selection required to enable LTG-EXT form. Zones are defined in Table C405.5.2(1) and specified by the jurisdiction. For Building Department Use Calculation Area Co New construction CAddition - stand alone CAddition + existing CAlteration with < 50% i�AIteration with >_ 50% ext. ext. wattage replaced wattage replaced User Note Building Grounds Applies to individual luminaires > 100 Watts D( Efficacy > 80 lumens/watt C Exemption Controlled by motion sensor Tradable Maximum Allowed Lighting Wattage NOTE 1 Base Site Allowance: 500 Tradable Surfaces Surface Description Area (ft), perimeter (If) or # of items Allowed Watts per ftZ or per If Allowea Watts x ftZ (or x If) 11T12 Uncovered Parking and drives parking lot 6243 0.04 W/ft2 250 Grounds Walkways <10 wide entry walkway & circulation within structure 1950 0.7 W/LF 1365 Main Entry Door unit entries 225 20W/LF door 4500 Other Entry Door unit patios & decks 727 20W/LF door 14540 Total Allowed Tradable + Site Allowance Watts: 21155 Tradable Proposed Lighting Wattage NOTE 3 Tradable Surface Fixture Description NOTE4, 5 Number of Fixtures VVdLLZS Pt:1Watts Fixture NOTE 6 Proposed Uncovered Parking and drives pole mounted LED light 3 78 234 Grounds Walkways <10 wide bollard light fixture 1 25 25 Grounds Walkways <10 wide exterior wall sconce 15 14 210 Main Entry Door exterior wall sconce 1 10 114 1140 Other Entry Door exterior wall sconce 1 10 114 1140 Total proposed tradable watts may not exceed the sum of total allowed tradable watts Total Proposed Tradable Watts: 749 plus the base site allowance. Any base site allowance not needed to make tradable watts comply can be applied to individual non -tradable categories. Non -Tradable Maximum Allowed Lighting Wattage NOTE' Site Allowance Remaining: 500 Non -Tradable Surfaces Surface Description Area (ftZ), perimeter (If) or # of items Allowed Watts per ftZ, If or item Allowed Watts x ftZ (or x If) Nore 2 Non -Tradable Proposed Lighting Wattage NOTE 3,7 Non -Tradable Surface Fixture Description NOTE 4, 5 Number of Fixtures Watts per Fixture NOTE 6 Watts Proposed Non -tradable proposed watts may not exceed allowed watts for any individual surface Non -Tradable Watts Exceeding LPA: 0 unless the total excess watts for all non -tradable surfaces are less than the remaining site allowance. Remaining Site Allowance: 500 Exterior Lighting COMPLIES WITH MAX. ALLOWANCE Note 1- List all exterior surfaces per Table C405.5.2(2) that occur in the project scope. Select exterior surface categories from drop down menu. Note 2 - Unlit Message - Enter lighting fixture information for this surface in Proposed Lighting Wattage table to generate Lighting Power Allowance. Note 3 - List all proposed lighting fixtures including existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type, number of lamps in the fixture, and ballast type (if applicable). Note 5 - Existing -to -remain fixtures shall be included in the Tradable and Non -Tradable Proposed Lighting Wattage tables in the same manner as new fixtures. Identify as existing in fixture description. Note 6 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. Note 7 - Automated Teller and Night Depositories - For each location, enter the number of ATM machines or depositories within that location. If there are multiple locations in the project, enter each location individually in the Non -Tradable Maximum Allowed Lighting Wattage table and identify the location in the Surface Description section. Lighting, Motor,and Electrical Permit ' • 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Edmonds Crossing Apartments Date 7/26/19 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability Location in Building Department (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes LIGHTING CONTROLS No C405.2 Lighting controls, For all lighting fixtures, indicate lighting control method on plans for general spaces and lighting zones served, or exception taken Luminaire level Indicate on plans all fixtures provided with LLLC in lieu of C405.2 NA C405.2 lighting controls lighting controls; provide description of control capabilities and (LLLC) performance parameters Lighting in dwelling For permanently installed lighting fixtures in dwelling units, indicate No C405.1 units lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception C405.2.3 C405.2.1.1 Indicate on plans the method of manual lighting control (whether No C405.2.2.2 Manual controls combined with occupancy sensor, automatic light reduction, C405.2.4 daylight responsive or specific application controls), location of C405.2.5 manual control device and area or specific application it serves C405.2.2.1 Manual interior light Indicate on plans which method of manual 50% lighting load NA C405.2.2.2 reduction controls reduction is provided, or whether lighting load is reduced via C405.2.3 occupancy sensors or daylight responsive controls Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor, time switch or digital timer NA C405.2.2 Method of automatic switch) for all lighting zones; Indicate locations where automatic shutoff is provided by other shut-off control methods (occupancy sensor or digital timer switch) or which time switch control exception applies Indicate on plans the spaces served by occupancy sensors; Indicate whether occupancy sensor controls are configured to be NA C405.2.1 Occupancy sensor C405.2.1.1 controls manual -on, automatic 50%-on, or serve a space eligible for automatic 100%-on per exception NA C405.2.1.2 Occupancy sensor Indicate aisleways and open areas in warehouse spaces provided controls - warehouses with occupancy sensor controls that reduce lighting power by 50% NA C405.2.2.1 Automatic time switch Indicate locations of override switches on plans and the lighting controls zones served, include areas . ft. C405.2.6 Digital timer switch Indicate digital timer switch control includes: manual on/off, time delay, audible and visual indication of impending time-out Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.; C405.2.4.2 Daylight zones - Indicate toplight daylight zone areas on plans, include sq. ft.; For small vertical fenestration assemblies (rough opening less than NA C405.2.4.3 Sidelight and toplight 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided Daylight responsive with daylight sensing controls and the exception(s) that apply; Indicate on plans the lighting load reduction method - continuous NA C405.2.4 controls dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power; Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone Additional controls Identify spaces and lighting fixtures on plans that require specific NA C405.2.5 Specific application application lighting controls per this section lighting controls Indicate on plans that display and accent lighting, and display case NA C405.2.5 - Display and accent lighting are controlled independently from both general area Items 1&2 lighting lighting and other lighting applications within the same space; Indicate manual and automatic lighting control method Lighting, Motor,and Electrical Permit ' • 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Edmonds Crossing Apartments Date 7126119 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington Applicability Location in Building Department (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes C405.2.5 - Hotel/motel guest Indicate method of automatic control - vacancy or captive key NA Item 3 control of all installed luminaires and switched receptacles in guest rooms room C405.2.5 - Supplemental task Indicate method and location of automatic shut-off vacancy control NA Item 4 lighting for supplemental task lighting, including under -shelf or under - cabinet lighting Indicate on plans eligible non -visual lighting applications, include sq. ft. area of each lighting control zone; Indicate on plans that non -visual lighting are controlled C405.2.5 - Lighting for non -visual NA Item 5 applications independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control Indicate on plans that lighting equipment for sale or demonstration C405.2.5 - Lighting equipment for are controlled independently from both general area lighting and NA Item 6 sale or demonstration other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; Provide calculation of lighting power density of total egress lighting; C405.2.5 - Means of egress Yes Item 7 lighting If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; Indicate method of automatic shut-off control Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served; For building facade and landscape lighting, indicate automatic Exterior lighting controls shut off lighting as a function of dawn/dusk and fixed No C405.2.7 controls opening/closing time; For all other exterior lighting, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am- 6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor Exterior building For building grounds fixtures greater than 100 watts, indicate on No C405.5.1 grounds lighting plans whether fixtures have efficacy greater than 80 lumens or; are controls controlled by motion sensor, or are exempt lighting per C405.5.2 Indicate location(s) of master control switch(es) intended to control C405.2.5 Area controls - Master multiple independent switches; circuit breaker may not be used as NA (listed after control switches and a master control switch; C405.2.7) circuit power limit Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80% ADDITIONAL EFFICIENCY PACKAGE OPTION - ENHANCED DIGITAL LIGHTING CONTROLS To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and NA C406.4 Enhanced digital provided with continuous dimming, or exception taken; Include calculation of percent total installed interior lighting power lighting controls that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) Lighting, Motor,and Electrical Permit ' • 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Edmonds Crossing Apartments Date 7126119 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington pp ica i dy Location in Building Department (yes,no,na) I Code Section Component Compliance information required in permit documents Documents Notes INTERIOR LIGHTING POWER & EFFICACY Include all luminaires in lighting fixture schedule; indicate fixture A70 types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify spaces eligible for lighting power exemption on plans and in compliance forms; indicate the exception applied; Yes .. C40541 C405.4.2 Total connected interior lighting power Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independent) NA C405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per side) If high efficacy exception is applied to permanently installed lighting Lighting in dwelling fixtures in dwelling units, indicate in lighting fixture schedule if NA C405.1 units -lamp efficacy lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). Interior Li h ng Power Calculation - Indicate compliance path taken Complete required compliance forms — proposed wattage per Yes C405.4.2.1 Building Area Method building area does not exceed maximum allowed wattage per LTG-INT-BLD building area; identify locations of building areas on plans Complete required compliance forms — total proposed wattage NA C405.4.2.2 Space -By -Space does not exceed maximum allowed wattage; identify locations of Method space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable ADDITIONAL EFFICIENCY PACKAGE OPTION - REDUCED INTERIOR LIGHTING POWER DENSITY To comply with additional efficiency package option, demonstrate in NA C406.3 Reduced lighting compliance forms that total connected interior lighting wattage is power density 25% less than the total maximum allowed lighting wattage via Building Area Method or Space -By -Space Method Reduced lighting For project with dwelling units, to comply with additional efficiency power density - package option indicate in lighting fixture schedule if lamps in NA C406.3 dwelling unit lamp interior fixtures have efficacy rating of 60 lumens per watt or more. efficacy Calculate percentage of fixtures with lamps that have this efficacy rating (min 95 /o to comply with option) EXTERIOR LIGHTING POWER & EFFICACY Include all luminaires in lighting fixture schedule; indicate fixture A70 types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption Total connected Yes C405.5.2 exterior lighting power on plans and in compliance forms; indicate exception applied; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category Yes Table C405.5.2 1 Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ A70 Exterior building For building grounds fixtures rated at greater than 100 watts that NA C405.5.1 grounds lighting are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule Exterior lighting power Complete required compliance form — proposed wattage for Yes C405.5.2 calculations exterior lighting plus base site allowed does not exceed maximum LTG-EXT allowed Lighting, Motor,and Electrical Permit ' • 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Edmonds Crossing Apartments Date 7/26/19 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington pp ica i dy Location in Building Department (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes LIGHTING ALTERATIONS Where >_ 50% of existing luminaires in interior space(s) or parking garage are replaced; indicate compliance path (building area or space -by -space method); include all new and existing -to -remain luminaires in compliance form (LTG-INT-BLD or LTG-INT-SPACE); Interior and parking indicate proposed lighting wattage does not exceed maximum NA C503.6 garage lighting fixture allowed per compliance path Where < 50% of existing luminaires in interior space(s) or parking alterations garage are replaced; indicate total existing lighting wattage in each space prior to alteration; include all new and existing -to -remain luminaires in LTG-INT-SPACE form; indicate proposed total lighting wattage in alteration area does not exceed total existing lighting wattage prior to alteration Where >_ 50% of existing exterior lighting wattage is replaced; include all new and existing -to -remain luminaires in LTG-EXT form; indicate proposed total exterior lighting wattage does not exceed NA C503.6 Exterior lighting fixture maximum allowed alterations Where < 50% of existing exterior lighting wattage is replaced; indicate total existing lighting wattage prior to alteration; include all new and existing -to -remain luminaires in LTG-EXT form; indicate proposed total exterior lighting wattage does not exceed total existing wattage prior to alteration Where new wiring is installed to serve new interior luminaires and Interior lighting wiring /or luminaires are relocated to a new circuit; indicate lighting NA C503.6 alterations controls are provided (as applicable) - manual (C405.2.3); occupancy sensor (C405.2.1); daylight responsive (C405.2.4); specific application (C405.2.5); exit signs (C405.3) NA C503.6 Exterior lighting wiring Where new wiring is installed to serve new exterior luminaires and /or luminaires to indicate lighting alterations are relocated new circuit; exterior controls are provided (C405.2.7) Where a new lighting panel is installed or an existing panel is Lighting panel moved (all new raceway and conductor wiring); indicate lighting NA C503.6 alterations controls are provided (as applicable) - same provisions as wiring alterations; time switch controls and manual light reduction controls (C405.2.2) Interior space Where interior space(s) is reconfigured (permanently installed walls NA C503.6 reconfiguration or ceiling -height partitions); indicate lighting controls are provided (as applicable) - same provisions as lighting panel alterations Identify existing luminaires being upgraded with bulb and / or NA C504.2 Lighting repairs ballast replacement; indicate fixture alteration does not increase existing fixture wattage Identify spaces on plans where the building area type or space use type is being changed from one type to another per Tables C405.4.2(1) or (2) Indicate compliance path (building area or space -by -space NA C505.1 Change of space use method); include all new and existing -to -remain luminaires in compliance form (LTG-INT-BLD or LTG-INT-SPACE); indicate proposed lighting wattage does not exceed maximum allowed per compliance path RECEPTACLES Identify all controlled and uncontrolled receptacles on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, No C405.10 Controlled receptacles duplex devices, etc; Indicate on plans whether the method of automatic control for each controlled receptacle zone is by occupant sensor or programmable time -of -day control Lighting, Motor,and Electrical Permit ' • 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Edmonds Crossing Apartments Date 7126119 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington pp ica i dy Location in Building Department (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes MOTORS, TRANSFORMERS, ELECTRIC METERS, INTERIOR TRANSPORTATION No C405.6 Electrical transformers Include electrical transformer schedule on electrical plans; indicate transformer size, efficiency, or exception taken No C405.7 Dwelling unit electrical Indicate on electrical plans that each dwelling unit in Group R-2 energy consumption has a separate electrical energy meter Electric motor Include all motors, including fractional hp motors, in electric motor No C405.8 efficiency schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied For luminaires in each elevator cab, provide calculated average efficacy of combined fixtures that indicates efficacy is not less than 35 lumens per watt; NA C405.9.1 Elevator cabs Indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm; Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoccupied for a period of 15 minutes or more Escalators and Indicate escalators comply with ASME A17.1/CSA B44; automatic NA C405.9.2 moving walks controls are configured to reduce operational speed to the minimum permitted when not in use NA C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING (Cx) Indicate that all electrical systems (receptacles, transformers, motors, vertical and horizontal transportation) for which the WSEC requires control functions and / or configuration to perform specific Scope of electrical functions are required to be commissioned; Where total building lighting load is > 20 kW, or where total lighting NA C408.3 power and lighting systems load of luminaires requiring daylight sensing and / or occupancy commissioning control > 10 kW, indicate that all automatic lighting control systems are required to be commissioned; or provide building lighting power calculation demonstrating eligibility for exception; Indicate Cx requirements in plans and specifications for all applicable electrical and lighting control systems per C408; Include general summary with at minimum Items 1 thru 4 of the Cx C405.13 Commissioning plan per C408.1.2 including: narrative description of activities, C408.1.1 requirements in responsibilities of the Cx team, schedule of activities including NA C408.1.2 construction verification of project close out documentation per C103.6, and C408.1.4.2 documents conflict of interest plan (if required); Include in general summary that a Cx project report or Compliance C103.6 Checklist (Figure C408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final electrical inspection Functional Identify in plans and specifications the intended operation of all NA C408.3.1 performance testing equipment and controls during all modes of operation, including criteria interfacing between new and existing -to -remain systems PROJECT CLOSE OUT DOCUMENTATION Project close out Indicate in plans that project close out documentation is required NA C103.6.3 documentation including WSEC lighting compliance forms and calculations that requirements document all interior and exterior lighting area and / or surface types, lighting power allowances and installed densities If "no" is selected for any question, provide explanation: All controls for lighting will be shown on Electrical plans under separate permit application. All motors, transformers and meters will be shown on Electrical plans. End of Lighting, Motor & Transformer Permit Documents Checklist