Loading...
APPROVED ENG VAULT CG ENG BLD2019-0951DESIGN CRITERIA VERTICAL LOADS ON VAULT LID: UNIFORM LIVE LOAD 15OPSF *HS20 TRUCK WHEEL LOADS 131-611 14' to 30' 0 0 01j7- FRONT REAR REAR 0 0 0 TRACTOR TRAILER *FIRE TRUCK WHEEL LOADS ; 211-01, 11jfAT� FRONT AXLE = 81000 Ib. SINGLE REAR AXLE = 321000 Ib, TRAILER SINGLE REAR AXLE = 32,000 Ib, FRONT AXLE = 251000 Ib, l� REAR AXLES = 501000 Ib, FRONT REAR I °P (DUAL TANDEM( o EB *OUTRIGGER PAD POINT LOAD 451000 LB, DISTRIBUTED OVER 2411x2411 PAD @ 15'-011 o/c, = DESIGN LIVE LOAD, OUTRIGGER LOAD AND TRUCK WHEEL LOADS TO BE APPLIED INDEPENDENTLY AND IN COMBINATION WITH THE SOIL COVER DEAD LOAD, AT GRADE GRATING: SAME AS LID LOADING EXCLUDING OUTRIGGER LOAD, IMPACT & FATIGUE: DUE TO THE SLOW SPEEDS OF VEHICLES OVER THE LID, AND THE SOIL COVER OVER THE LID, INCREASES IN VEHICLE LOADS TO ACCOUNT FOR IMPACT & FATIGUE ARE NOT REQUIRED. SOIL COVER FOR LID DESIGN: PLANK MANUFACTURER SHALL BE RESPONSIBLE FOR DETERMINING THE SOIL COVER DEPTHS USED IN THE LID DESIGN BASED ON THE PERMITTED CIVIL DRAWING, VAULT AND FINISHED GRADE ELEVATIONS, SOIL COVER FOR SUBSTRUCTURE DESIGN: THE SUBSTRUCTURE WAS DESIGNED FOR THE FOLLOWING SOIL COVER OF 1,25FT MIN TO 3,OFT MAX ABOVE THE TOP OF THE LID. FOUNDATION DESIGN: FOUNDATION DESIGN IS BASED ON THE FOLLOWING VALUES PROVIDED BY GARY A, FLOWERS, PLLC, IN THEIR REPORT DATED 06-08-19 AND PHONE CONFIRMATION OF 10-30-19 ALLOWABLE BEARING PRESSURE; 21500 PSF LATERAL EARTH PRESSURES; (DRAINED LEVEL BACKFILL ACTIVE CONDITION; 35 PCF EFW AT REST CONDITION; 50 PCF EFW SEISMIC PRESSURE COMPONENT; E = 12H PSF UNIFORM SATURATED SOIL DENSITY; 125 PCF SPECIAL INSPECTION PLAN GENERAL: SPECIAL INSPECTION BY A QUALIFIED INSPECTOR IS REQUIRED IN ACCORDANCE WITH THE 2015 IBC, QUALIFICATION: THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE BUILDING OFFICIAL, REQUIRED VERIFICATION & INSPECTION: THE SPECIAL INSPECTOR SHALL PERFORM THE VERIFICATIONS & INSPECTIONS NOTED IN THE SCHEDULE BELOW INSPECTION & TESTING SCHEDULE TYPES OF WORK FREQ. 2015 IBC SECTION CAST IN PLACE CONC REINFORCING STEEL, PLACEMENT, P 1705.3 INSTALLATION & FASTENING OF PRECAST PANELS P 1705.3 PLACEMENT OF CONCRETE C 1705.3 VERIFYING USE OF REQUIRED DESIGN MIX p 1705.3 TESTING OF THE CONCRETE FOR SPECIFIED STRENGTH, AIR CONTENT AND SLUMP C 1705.3 STRUCTURAL STEEL STRUCTURAL STEEL ( GRATING ) FABRICATION P 1704.2.5 SOILS VERIFICATION OF SOIL -BEARING CAPACITY: INSTALLATION OF DRAINAGE SYSTEM: C 1705.6 PLACEMENT & COMPACTION OF WALL BACKFILL: P 1705.6 FREQUENCY LEGEND C = CONTINUOUS P = PERIODIC SEE REFERENCES AND STANDARDS LISTED WITHIN THE VERIFICATION & INSPECTION SCHEDULE FOR MEANING OF PERIODIC AND CONTINUOUS INSPECTIONS, SUBMITTAL OF REPORTS: ALL SPECIAL INSPECTION REPORTS AND TESTING REPORTS SHALL BE SUBMITTED TO THE OWNER, SITE STRUCTURES AND THE BUILDING OFFICIAL BY THE AGENCY PERFORMING THE INSPECTION OR TESTING, STRUCTURAL STEEL MATERIALS: a, STEEL WF SHAPES SHALL CONFORM TO ASTM A992 Fy=5OKSI b, OTHER STRUCTURAL STEEL SHAPES & PLATES SHALL CONFORM TO ASTM A36, C. WELD STUDS SHALL CONFORM TO ASTM A29-16 WELDING: CONFORM TO AWS D1,1 11STRUCTRUAL WELDING CODE - STEEL". WELDERS SHALL BE CERTIFIED IN ACCORDANCE WITH WABO REQUIREMENTS, USE E70 ELECTRODES OF TYPE REQUIRED FOR MATERIALS TO BE WELDED. GALVANIZING: ALL STEEL SECTIONS SHALL BE HOT DIPPED GALVANIZED AFTER FABRICATION CONFORMING TO ASM A-123, REPAIRS SHALL CONFORM TO ASTM A-780 USING ZINC RICH PAINT. THE COATING THICKNESS FOR THE PAINT MUST BE 50% MORE THAN THE SURROUNDING COATING THICKNESS, BUT NOT GREATER THAN 4,0 MILS, OPEN METAL GRATING OPEN METAL GRATING SHALL BE WELDED STEEL BAR GRATING AS SPECIFIED ON THE DRAWINGS. ALL STEEL GRATING AND GRATING COMPONENTS INCLUDING ITEMS EMBEDED WITHIN THE CONCRETE SHALL BE HOT DIPPED GALVANIZED AFTER FABRICATION, SEE STRUCTURAL STEEL NOTES FOR GALVANIZING REQUIREMENTS, SUPPLIER SHALL PROVIDE ALL COMPONENTS NECESSARY TO INSTALL AND SECURE THE GRATING IN PLACE & SHALL PROVIDE SHOP DRAWINGS DETAILING ALL COMPONENTS OF THE INSTALLATION, CONCRETE CONCRETE REQUIREMENTS: LOCATION STRENGTH MAX W/C RATIO VAULT WALLS & CIP LID 4000PSI @ 28 DAYS 0.50 GRADE SLAB & FTGS 3000PSI @ 28 DAYS 0.53 PLANK VOID FILL TO MEET PLANK MFGR'S REQUIREMENTS* PLANK JOINT GROUT TO MEET PLANK MFGR'S REQUIREMENTS* MINIMUM STRENGTH SHALL BE 3000PSI @ 28 DAYS. AIR CONTENT; CONCRETE EXPOSED TO WEATHER SHALL CONTAIN 5% +/-1X ENTRAINED AIR, MIX DESIGN; SHALL BE BASED ON FIELD EXPERIENCE OR TRIAL MIXTURES IN CONFORMANCE WITH THE SPECIFICATIONS, EXPOSURE CATEGORIES: FREEZING THAWING FO SULFATE SO IN CONTACT w/ WATER W1 CORROSION PROTECTION C1 MATERIAL REQUIREMENTS: CEMENT; ASTM C150, ADMIXTURES; ACI 301. AGGREGATES; ASTM C33, WATER; ASTM C94, PLACING REQUIREMENTS: PLACING; PLACE CONCRETE AS NEARLY AS PRACTICABLE TO ITS FINAL POSITION TO AVOID SEGREGATION, DEBRIS; REMOVE ALL DEBRIS FROM FORMS PRIOR TO PLACING CONCRETE, CONSOLIDATION; CONSOLIDATE CONCRETE BY SUITABLE MEANS. THOROUGHLY WORK CONCRETE AROUND EMBEDDED ITEMS AND INTO CORNERS OF FORMS, CURING REQUIREMENTS; CURING; CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A SUITABLE PERIOD OF TIME AFTER PLACEMENT, WEATHER CONDITIONS; ADEQUATE PRECAUTIONS SHALL BE TAKEN DURING HOT AND COLD WEATHER IN ACCORDANCE WITH THE SPECIFICATIONS, LID PLANK PLACEMENT: IN NO CASE SHALL THE LID PLANKS BE PLACED BEFORE THE WALLS HAVE BEEN ALLOWED A MINIMUM OF 3 DAYS OF CURE, WHEN AVERAGE AMBIENT TEMPERATURES ARE LESS THAN 50 DEGREES FAHRENHEIT, THE CONTRACTOR MUST ALLOW A MINIMUM CURE TIME OF 7 DAYS OR PROVIDE AN ADDITIONAL SET OF CYLINDERS TO BE BROKEN AT THE TIME OF LID PLACEMENT DEMONSTRATING A MINIMUM CONCRETE STRENGTH OF 11000 PSI HAS BEEN REACHED. REINFORCING BAR MATERIAL REQUIREMENT: REINFORCING BARS: USE DEFORMED BARS CONFORMING TO ASTM A615, GRADE 60, EXCEPT AS NOTED ON THE DRAWINGS. WELDED WIRE REINFORCEMENT: SMOOTH FABRIC SHALL CONFORM TO ASTM A185, FABRICATION AND PLACING REQUIREMENTS: BENDING: BARS SHALL BE BENT COLD, BARS PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT UNLESS NOTED OR SHOWN OTHERWISE OR AUTHORIZED BY THE ENGINEER. PLACING: REINFORCEMENT SHALL BE SUPPORTED AND TIED TO PREVENT DISPLACEMENT BY CONSTRUCTION LOADS OR BY PLACING OF CONCRETE, MAXIMUM SPACING OF SUPPORTS SHALL BE 31-611, CONCRETE COVER: MINIMUM CONCRETE COVER FOR REINF. SHALL BE AS FOLLOWS, UNLESS NOTED OTHERWISE; CONCRETE CAST AGAINST EARTH 311 CONCRETE CAST AGAINST FORMS AND EXPOSED TO EARTH 2" WET SETTINGS: REINFORCEMENT ANCHOR BOLTS, OR ANY EMBEDDED ITEM WITHIN THE CONCRETE, MAY NOT BE SET INTO THE CONCRETE AFTER IT HAS BEEN POURED WITHIN THE FORMS, LAP SPLICES: LAP ALL BARS 2411 MIN UNLESS SHOWN OTHERWISE ON THESE DRAWINGS, GENERAL CONSTRUCTION NOTES CODE: VAULT DESIGN AND CONSTRUCTION SHALL CONFORM TO THE PROVISIONS OF THE 2015 IBC AS ADOPTED BY THE CITY OF EDMONDS, WASHINGTON. GENERAL DETAILS: CONSTRUCTION DETAILS NOT FULLY SHOWN OR NOTED SHALL BE SIMILAR TO DETAILS SHOWN FOR SIMILAR CONDITIONS, DISCREPANCIES: THE CONTRACTOR SHALL NOTIFY ENGINEER UPON FINDING ANY DISCREPANCY OR OMISSION IN THE DRAWINGS OR SPECIFICATIONS, SHORING & EXCAVATION: THE CONTRACTOR SHALL BE SOLEY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES, INCLUDING LAGGING, SHORING AND PROTECTION OF ADJACENT PROPERTY, STRUCTURES, STREETS AND UTILITIES, WALL BACKFILL: PRIOR TO BACKFILLING VAULT WALLS THE CONTRACTOR SHALL HAVE PLACED THE LID PLANKS AND PROVIDED A MINIMUM OF 5 DAYS OF CURE ON THE PLANK VOID FILL. BACKFILL SOIL: WALL BACKFILL SHALL BE WELL GRADED FREE DRAINING SOIL FREE OF ORGANIC MATERIAL. BACKFILL SHALL BE PLACED IN LIFTS OF NO MORE THAN 8 INCHES AND COMPACTED TO WITHIN 90% OF THE SOILS MAXIMUM DRY DENSITY. ALL COMPACTION OCCURING WITHIN 5' OF THE WALL SHALL BE COMPLETED USING HAND OPERATED MACHINERY. HOLLOW CORE PLANK SCOPE OF WORK: THE WORK INCLUDED IS THE DESIGN, MANUFACTURE AND DELIVERY OF PRECAST PRESTRESSED CONCRETE UNITS. DESIGN PLANK FOR THE MOST CRITICAL OF THE LOADING CONDITIONS AS SHOWN WITHIN THE DESIGN CRITERIA NOTE, THE MANUFACTURER SHALL SUBMIT STRUCTURAL CALCULATIONS AND PLACEMENT DRAWINGS SIGNED BY A WASHINGTON STATE REGISTERED CIVIL ENGINEER FOR REVIEW PRIOR TO FABRICATION, THE MANUFACTURER SHALL INSTALL ALL BLOCK OUTS REQUIRED FOR STRUCTURAL CONNECTIONS AS INDICATED ON THESE DRAWINGS, NO OTHER PENETRATIONS ARE ALLOWED WITHOUT THE PRIOR APPROVAL OF THE PLANK MANUFACTURER, ALL HOLLOW CORE JOINTS SHALL BE GROUTED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, DEFERRED SUBMITTALS THE FOLLOWING AREAS OF WORK SHALL BE CONSIDERED AS "DEFERRED SUBMITTALS" AS DEFINED IN THE 2015 IBC a, PRECAST PRESTRESSED HOLLOW CORE PLANK b, CONCRETE MIX DESIGNS, C. OPEN METAL GRATING ASSEMBLY, ALL DEFERRED SUBMITTALS SHALL BEAR THE STAMP AND SIGNATURE OF A CIVIL ENGINEER LICENSED TO PRACTICE IN THE STATE OF WASHINGTON WHO HAS CURRENT DESIGN EXPERIENCE IN THE TYPE OF WORK REVIEWED, THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED BY THE ENGINEER OF RECORD, PRESSURE RELIEF VALVE PRESSURE RELIEF VALVES SHALL BE 4" m TROY MODEL A-2580/04 HYDROSTATIC RELIEF VALVE AND WALL THIMBLE MODEL 191001 WITH REMOVABLE GRATE, CONTRACTOR MAY SUBMIT ALTERNATE VALVE TYPES FOR CONSIDERATION, SUBMIT ALL DOCUMENTS RELATED TO THE ALTERNATE, INCLUDING INSTALLATION DETAILS TO THE ENGINEER FOR REVIEW, VALVES SHALL BE SHOWN TO OPEN AT A PRESSURE DIFFERENTIAL NOT EXCEEDING 911 OF WATER HEAD. ALTERNATE VALVES SHALL BE FULLY SERVICABLE TO MAINTAIN PROPER OPERATION OVER THE LIFE OF THE STRUCTURE, FILL WITH GROUT AS DIRECTED BY PRECAST PLANK MFGR, DO OC CONT, BACKER ROD IF REQ'D, TYP PLANK JOINT DETAIL SCALE 111=1'-01' #4@181lo/c EA WAY N r-IN N CONC DOBIE OR CHAIR TYP GRADE SLAB SECTION SCALE 1-1/2`4-011 T-011 MAX TYP WALL REINF a a �Q 4 a a a 4 a ADD #5x4811 DIAG EA FACE AS SHOWN ADD ONE VERT FULL HEIGHT REINF BAR EACH SIDE OF BLOCKOUT FOR EA PAIR OF VERT BARS CUT AT THE BLOCKOUT, SEE CIVIL DWGS PIPE LOCATION AND INVERT ELEVATION WALL REINF @ PIPE PENETRATION SCALE 3/4`4-011 �I 41 _ 011 #5@12"o/c HORZ & VERT ON / BACK FACE OF WALL, -- DOWELS TO FOOTINGS ARE NOT REQUIRED AT THESE VERT BARS #5 x2411x2411 CORNER — BARS TO MATCH HORZ WALL REINF TYP ALT. HOOK 2411 #5 x 3011 TO MATCH HORZ, #5@1211o/c HORZ & VERT ON BACK FACE OF WALL, DOWELS TO FOOTINGS ARE NOT REQUIRED AT THESE VERT BARS #5 x24114411 CORNER BARS TO MATCH HORZ WALL REINF TYP 4'-011 TYP WALL CORNER REINF NTS C REVIEWED- Cameron Partlow, PE ENGINEERING DATE 08.21.2020 civil & structural REVIEWED AND APPROVED engineering&planning FOR GENERAL CONFORMANCE Z O H a c� J la 0. a t= y W la � 0 o (A o U � o a ME 0 W LPL WZ p 0 5 W a CO W y 0 N W 0 N WL N L o y 0 E 0. 0 i a •� E C �j Y Im i 0D0 Y 2 o a o 3 w a Oc�v -vcc C G 20744 Fss�0Na1. Z J 0 (3 a Z ca Z 0 Z W W Wcc 0 a Z 0 W U. p O I.. r c) 0 SHEET: S10F 3 S-19-087 PROVIDE HINGED SECTION OF GRATING @ ACCESS LADDER. SEE PLAN FOR - LOCATION GALVANIZED STEEL GRATING W-19-4 w/ 3"x1/4" BRG BARS. GALVANIZED,W8x28 1 8" THICK CURB TYP @ THE PERIMETER OF THE OPENING, REINF w/ #5@12"o/c HORZ, & VERT. PROVIDE (2)-#5 CONT HORZ BARS @ THE TOP OF THE CURB, SEE CIVIL DWGS FOR TOP OF CURB ELEV, 1 1 GALVANIZED STEEL ANGLE SEAT 3-1/2x3-1/2x1/2 w/ 1/211mx4" HEADED WELD STUDS AT 1211o/c, PLACE THE 1ST STUD NO MORE THAN 6" FROM EACH CORNER, BREAK ANGLE SEAT AT W8x28 BEAM SEAT. GRATING & CURB @ 5FTx10FT OPNG SCALE 3/811=1'-O" 8" THICK CURB GRATING 1 /411 CLR MAX GALVANIZED W8x28 TO BEAR 3-1/4" MIN ONTO STEEL ANGLE SEAT, SEE 2/52, VAULT STRUCTURE I I I I I I n BM SEAT DETAIL S� SCALE 1114-011 GRATING 3-1/2x3-1/2 ANGLE SEAT -� 8" THICK CURB LID STRUCTURE, AS OCCURS EXTEND VERTICAL CURB VERT. REINF INTO CLOSURE POUR VAULT STRUCTURE 3 TYP CURB @ OPNG 92 SCALE 111=1'-011 3-1/2x3-1/2 ANGLE SEA 32x32x2x9" ANGLE SE/ w/ (2)-3/4" 0 WELD STUI @ 6"o/c LID STRUCTURE SEE LID PLAN 2 BM SEAT DETAIL S2 SCALE 111=1'-011 CURB AND GRATE @ OPNG VAULT LID PLAN SCALE 3/16" = 11-0" #4 TIES @ 5"o/c, PLACE FIRST TIE 4 NO MORE THAN S3 2-1/2" FROM SUPPORT, I I I I � o I I CIO I cV >L (5)-#6 TOP __/ & BOT 2 11-1011 S 3 4 SLAB BEAM @ OPNG S2 SCALE 111=1'-011 91 31-611 _ 51-011 I_ 31-01, I_ 51-011 I_ 31-01, I_ 51-011 F28x12 51-011 L 31-011 771-411 761-011 51-011 31-011 _ 51-011 31-011 51-011 S3 F28x12 31-011 _ 51-011 I_ 31-01, I_ 51-011 _ 31-611 --— ---- --- — — — — — — — — — — — — — 1� 10 _---------- ---r-------------------- ---------------------------- r F40x12 I I I — — — — — — — — — — — — — ------ ---—--�---- �/ ---------------------------------- - - - -------- -TYP @----------- 14 A OPNG S3 --- — ---i1\ �— — — — — — — — I 10 1 — — — — — — — — — — — — — — — — J ---------------------- --------- - ----------------- - - - - - - - - - - - - F40x12 14 I I I 1 IB V=384,06 1 10'-011 TYP 17 1 — I I 4 I 1 ------------10 J IBOV=384,30 ------------� 1 5" THICK CONCRETE SLAB ON GRADE IBOV=38 ,30 I 1 I I IBOV=384,90 I TAP @ PERIM10 WALL I VAULT WALL 1 F34x12 g 1 F34x12 15'-011 S3 S3 35,_011 VAULT FOUNDATION PLAN SCALE 3/16" = 11-011 13i_On x co N LL 2 S3 a PLAN KEYNOTES 1, 511 THICK CONCRETE SLAB ON GRADE REINF WITH #4 @ 181lo/c EA WAY. PLACE ALL REINF AT MID -DEPTH OF THE SLAB, CAST GRADE SLAB IN A SINGLE POUR, SEE 2/S1 FOR REINF PLACEMENT DETAIL, 2, C,I,P, CONCRETE WALLS AT THE PERIMETER & INTERIOR OF THE VAULT. SEE WALL SECTIONS ON S3 FOR THICKNESS & REINFORCING, 3, THICKENED SLAB FOOTINGS TO BE CAST WITH THE GRADE SLAB. SEE WALL SECTIONS ON S3 FOR SIZE & REINF, 4, REMOVABLE BAFFLE WALL, SEE 7 & 8/S3 FOR DETAILS, 5, PIPE INLET OR OUTLET TO VAULT, SEE CIVIL DWGS FOR PIPE DIAM, LOCATION & INVERT ELEV, SEE 3/S1 FOR WALL REINF @ PENETRATION, 6, 12-1/211 THICK PRECAST HOLLOW CORE PLANK, SEE S1 FOR LID LOADING REQUIREMENTS, 7, 2411 DIAM, OPENING THRU CAST IN PLACE LID TO ACCEPT RISERS, LADDER, RING & LOCKING MANHOLE COVER PER CIVIL DRAWINGS. g POUR SLOTS IN TOP OF PLANK, MANUFACTURER TO PROVIDE A MINIMUM OF 3 SLOTS @ EACH END OF EACH PLANK. PLANK MANUFACTURER MAY REQUIRE GROUTING OF ADDITIONAL CELLS BEYOND THE MINIMUM OF 3, THE GENERAL CONTRACTOR SHALL INCLUDE GROUTING OF THESE ADDITIONAL CELLS IN HIS BID. 9, PROVIDE BLOCKOUTS IN THE EDGE CELL OF THE PLANK PARALLEL TO THE PERIMETER VAULT WALLS. LOCATE BLOCKOUTS APPROXIMATELY AS SHOWN ON THIS PLAN, SEE WALL SECTIONS FOR REINFORCING, 10. 4110 THRU WALL PRESSURE RELIEF VALVE. SEE WALL SECTIONS AND THE STRUCTURAL NOTES FOR VALVE SPECIFICATIONS & INSTALLATION DETAILS. 11, 51x1O' AT GRADE OPENING TO RECEIVE OPEN METAL BAR GRATING w/ 301 SQ INTEGRAL HINGED ACCESS HATCH, SEE A/S2, 12, HATCHED AREA REPRESENTS 20" WIDE x 12-1/211 THICK CAST IN PLACE SLAB BEAM. SEE 4/52 FOR REINFORCING, 13, 12-1/211 THICK CAST IN PLACE CONCRETE SLAB, SEE 3/S4 FOR REINFORCING, 14. 5FT WIDE OPENING, TYP ALONG THIS LINE. SEE A/S3 FOR WALL REINFORCING @ OPNG, 15, ADD (1145 DIAGONAL BARS TOP & BOT AS SHOWN, 16, ADD (2k#6 @ 6110/c TOP & BOT AS SHOWN, 17, MC10 x 8.4 CENTER SUPPORT, SEE 7/53 18, ADD (4146x15'-011 @ 311o/c ALONG THE INSIDE FACE OF THE VAULT WALL NEAR THE TOP OF THE WALL, PLACED AS SHOWN, LEGEND IBOV INSIDE BOTTOM OF VAULT ITOV INSIDE TOP OF VAULT LID CIP CONCRETE WALL CONCRETE SPREAD FOOTING F28x12 2811 WIDE x 1211 THICK FTG. SEE 2, 3 & 4/S3 F40x12 4011 WIDE x 1211 THICK FTG, SEE 3/53 F34x12 3411 WIDE x 1211 THICK FTG, SEE 1/S3 L� GRATING SPAN < DIRECTION OF DOWNWARD SLOPE THRU WALL PRESSURE RELIEF VALVE CONSTRUCTION LOADS THE VAULT LID HAS BEEN DESIGNED TO CARRY THE "DESIGN LOADS" ONLY AFTER VAULT CONSTRUCTION IS COMPLETE, ALL DESIGN CONCRETE AND GROUT STRENGTHS HAVE BEEN ACHIEVED, AND ALL COVER HAS BEEN PLACED OVER THE VAULT WITHIN THE LIMITS SPECIFIED ON THIS DRAWING, "BOBCAT" OR OTHER LIGHT EQUIPMENT SHALL BE USED FOR PLACEMENT OF MATERIALS OVER THE VAULT LID. ALTERNATIVELY, ALLOWABLE UNIFORM LOADS ON THE BARE SLAB CAN BE OBTAINED FROM THE PLANK MFGR, DIMENSIONS & ELEVATIONS THE CONTRACTOR AND HIS SUBCONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND ELEVATIONS SHOWN ON THESE DRAWINGS WITH THE CURRENT PERMITTED SET OF CIVIL DRAWINGS, AND SHALL NOTIFY BOTH THE CIVIL & STRUCTURAL ENGINEERS IN WRITING OF ALL DISCREPANCIES BETWEEN THE CIVIL DWGS AND THESE DWGS PRIOR TO CONSTRUCTION, Z O H a 0 J d a a � y W a � 0 o z o U � V a rE O W LPL WZ p O =D W co co W co 0 N W O N ON O y 0 41 a i M * •0 E c m Y m 4 anoho Y Za o a� o >� m .. w < ail Oc�v -vcc G 20744 �► crANAL ss�oNal. ~ o � a z > _ W Z CO) 3 � O H F. � Z a W a W ao cc Wcc G ~ a z Z 3 o 0 0 W Q � LL 0 W O c) C.) Z J d Z 0 a� J z Q W LLL 0 an 0 J J a SHEET: C 4 REVIEWED: Cameron Partlow, PE ENGINEERING DATE 08.21.2020 civil & structural REVIEWED AND APPROVED engineering & planning FOR GENERAL CONFORMANCE OF 3 S-19-087 103 ■......... y.w................... NI ...............y.F...------- 1-1 H . WALL REINF @ OPENING SCALE 1/2"=1'-O" 4'-0" WIDE PLANK I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I l I I I I I I I I JI I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I --- I I I I I I I I I I I I PLAN VIEW 3611 #5x 1511 C CLOSURE TO WALL DOWELS @ 30"o/c, d- 3611 #5 x 2411 C LID TO CLOSURE DOWELS @ EA PLANK, I I 1 1 1 VAULT WALL ELEVATION VIEW LID & WALL TO CLOSURE DOWELS AT PLANK VOID END FILL 811 WALL SCALE 3/4114-011 6 1 TYP WALL SECTION 2 TYP WALL SECTION S3 SCALE 1/2"=1'-O" S3 SCALE 1/2"=1'-0" 12" #4 x11411 SET @ CENTER OF VOID 11-011 j -41 ------------�-- 00 ---------------- � 'IQ O O PLAN VIEW 3611 #5x 1511 C CLOSURE TO WALL DOWELS @ 3011o/c, HOLLOW CORE 1' 0" PLANK IL 4 F --------- ---- #5 @ CENTER OF --- ------- ------- - VOID ----- . CELL BLOCKOUT 1 PERIMETER WALL WALL VERT REINF EXTENDING INTO CLOSURE 1211 #4 x11411 SET @ ENTER OF VOID ------' ----- ■ ■ J ■ ■ ■ ■ N ■ ■ ■ ■ VAULT WALL ELEVATION VIEW LID & WALL TO CLOSURE DOWELS 1 AT VOID BLOCKOUTS 811 WALL SCALE 3/4" 4-011 HOLLOW CORE PLANK PROVIDE VERT SLOTTED HOLE IN CHANNEL GALVANIZED STEEL MC 8x18,7 SEE CIVIL FOR ELEVATION (2)-5/80 x 3" LAG GALVANIZED BOLTS @ EA 4x12 SEE CIVIL FOR ELEVATION GRADE SLAB TYP WALL SECTION GALVANIZED STEEL ANGLE LLV 3x4x1/4x12" TYP T&B J21-1/40 SS "HILTI" HDI DROP IN ANCHORS 61911o/c w/ 1" EMBED INTO BOT OF PLANK, DO NOT OVERDRILL HOLE DEPTH 121 5/8110 BOLTS @411o/c TYP T&B SNUG FIT (NOT TIGHT BAFFLE WALL CENTER POST SCALE 1-1/2"=1'-0" 4x12 PRESSURE TREATED HF #2, SEE 8/S3 FOR ATTACHMENT TO CONC WALL (2)-1/2110 SS "HILTI" KWIK BOLT TZ EXP ANCHORS @ 911o/c w/ 2-1/211 EMB 4 TYP WALL SECTION S3 Note: These are critical to drainage function; inspector please confirm these are installed and a water tiaht seal is created so retained water will not flow out of the vault. MAX 0 0 DOWEL & VERT REINF TO BE PLACED IN LINE DOWN THE LENGTH OF THE WALL 00 DOWEL w/o_ / FTG TO WALLS L VERT WALL REINF VERT BAR DOWEL SPLICE 2" MAX DOWEL & VERT REINF TO BE PLACED IN LINE DOWN THE LENGTH OF THE WALL DOWEL w/off FTG TO VERT BAR WALL SPLICE DOWEL TYP DOWEL PLACEMENT SCALE 1"=1'-0" 2" MAX VERT WALL REINF 1/2110 SS "HILTI" KWIK BOLT TZ EXPANSION ANCHORS @24"o/c w/ 2-1/211 EMB INTO THE CONCRETE WALL 22" (2)-5/80 x 3" GALVANIZED LAG BOLTS @ EA 4x12 31lx4"x1/4" GALVANIZED STEEL OR ALUMINUM ANGLE 4x12 PRESSURE TREATED HF#2, FACE OF CONC WALL BAFFLE WALL END CONNECTION SCALE 3"=1'-O" WALL SECTION GENERAL KEYNOTES 101. PROVIDE CONTINUOUS 4" PVC WATERSTOP - RIBBED WITH CENTERBULB AT THE BASE OF ALL PERIMETER WALLS, INSTALL WATERSTOP IN ACCORDANCE WITH ALL MANUFACTURER'S INSTRUCTIONS, PLACE AT THE CENTER OF THE WALL 102. 12-1/2" THICK PRECAST HOLLOW CORE PLANK. 103. FINISHED GRADE, ELEVATION VARIES, SEE DESIGN CRITERIA ON SHEET S1 FOR APPROXIMATE SOIL DEPTHS OVER THE VAULT LID IN ADDITION TO THE CIVIL DWGS FOR FINAL GRADE ELEVATIONS, 104. 6110 PERFORATED PVC FTG DRAIN SET IE 389,90, ROUTE DRAIN TO DISCHARGE POINT AS SHOWN ON THE CIVIL DWGS. 105. APPLY PREFABRICATED DRAINAGE PANEL TO ALL PERIMETER VAULT WALLS. EXTEND DRAINAGE PANEL OVER THE HEIGHT OF THE WALL AS SHOWN, SEE GEOTECHNICAL ENGINEER FOR MATERIAL SPECIFICATIONS, 106. PLANK TO BEAR 3" MINIMUM ONTO THE TOP OF THE CONCRETE WALL. SEE PLANK MANUFACTURER'S DRAWINGS FOR FINAL BEARING LENGTH. INSTALL BEARING PAD AS DETAILED ON THE PRECAST PLANK PLACEMENT DRAWINGS. 107, SEE FOUNDATION PLAN FOR SLAB REINFORCING, 108. 12-1/2" THICK CAST IN PLACE CONCRETE LID. 110. WALL PRESSURE RELIEF VALVE, 4110 TROY MODEL A-2580/04 WITH WALL THIMBLE MODEL 191001 WITH REMOVABLE GRATE, INSTALLATION SHALL BE IN ACCORDANCE WITH ALL OF THE MANUFACTURERS REQUIREMENTS, SET I. E. OF -� VALVE 6" ABOVE BOTTOM OF VAULT, SEE FOUNDATION PLAN FOR VALVE -c LOCATIONS, TIE TO 4110 PERFORATED PVC FTG DRAIN, 111, 4 m ER 0 AT D PVC FOOTI G RAIN SET I ' BO E B0TT M OULT AT THE WALL , TIE TO THRU-WALL PRESSURE RELIEF VALVES, 112. PROVIDE 16" THICK LAYER OF FREE DRAINING GRANULAR FILL BELOW THE UPPER FOOTING DRAIN, APPLY FILTER FABRIC BETWEEN FREE DRAINING MATERIAL & NATIVE BACKFILL MATERIAL, SEE GEOTECHNICAL ENGINEER FOR MATERIALS REQUIREMENTS. WALL SECTION REINF KEYNOTES 201. 8" THICK CONCRETE WALL REINF w/ #5@12"o/c HORZ & #6@10"o/c VERT, PLACE VERT REINF NEAR THE INSIDE FACE OF THE WALL, LAP ALL HORZ BARS 2411 MIN @ SPLICE LOCATIONS, PROVIDE (2145 CONT HORZ BARS @ THE TOP OF THE WALL, EXTEND VERT REINF 1111 MIN INTO THE LID CLOSURE POUR WHERE POSSIBLE, 202, 8" THICK WALL REINF w/ #5@12"o/c HORZ & VERT, PLACE VERT, REINF AT THE CENTER OF THE WALL AND EXTEND 11" ABOVE THE TOP OF WALL INTO THE C,I,P LID. PROVIDE (2145 VERT AT THE FREE ENDS OF THE WALL AND (2145 HORZ AT THE TOP OF THE WALL, 203, #5 FTG TO WALL DOWEL @ EA VERT, PROVIDE STD HOOK @ END OF BAR CAST INTO FOOTING, DOWELS SHALL BE EMBEDDED A MIN, OF 9" +/- 1/211 INTO THE 1211 THICK FTG & SHALL EXTEND INTO THE WALL 2811 MIN. SEE 9/S3 FOR PLACEMENT DETAIL, 204, #5x4'-0"@24"o/c PLACED SUCH THAT EACH 4811 WIDE PLANK RECEIVES (2) BARS. LOCATE BARS IN VOIDS WITH POUR SLOTS AS SHOWN ON THE PRECAST PLANK PLACEMENT DWGS, PROVIDE ADDITIONAL BARS @ EACH PLANK IF REQ'D AND SHOWN ON THE PRECAST PLANK SHOP DWGS. 205. LID & WALL TO CLOSURE POUR REINF @ VOID BLOCK OUT, SEE 6/S3, 206. LID & WALL TO CLOSURE POUR REINF @ VOID END FILL, SEE 5/63. 207. (3�46 CONT IN CLOSURE POUR, LAP 3611 @ ALL SPLICE LOCATIONS, 208, (2�45 CONT, ABOVE WALL, LAP 3011 @ ALL SPLICE LOCATIONS 209. #5 LONG BOTTOM AS SHOWN, LAP 2411 @ ALL SPLICE LOCATIONS, 210, #5@15"o/c TRANS BOT, 211, PROVIDE (2145 VERT EACH JAMB OF WALL OPNG, 212. I4I45 LONG TOP & BOTTOM, LAP 3011 @ ALL SPLICE LOCATIONS, 213. #5 @12"o/c TRANSVERSE BOT, 214. 12146 CONT HORZ BARS, SPLICES WHERE REQUIRED SHALL OCCUR AT THE CENTER OF THE WALL PIERS, LAP 3611 AT ALL SPLICE LOCATIONS, 215. #4 VERT w/ 180 HOOK @ HEAD OF OPNG, SPACED AS SHOWN, 216. I2I45 x 4'-011 DIAGONAL BARS, 217, (2�45 CONT HORZ @ THE TOP OF THE WALL. 218. #4@15"o/c WALL TO FOOTING DOWELS, EXTEND 4011 INTO THE WALL AND 9" INTO THE 1211 THICK FOOTING, PROVIDE STD HOOK AT END OF BAR EMBEDED WITHIN FTG. PROVIDE (2�44 CONT HORZ, BARS AS SHOWN, SET DOWELS 1-1/211 CLR FROM THE BACKFILLED FACE OF THE WALL, 219, #6@12"o/c BOT TRANS, SET 2" CLR FROM SLAB SOFFIT, 220, #5@12"o/c LONG BOT, SET ABOVE #6 TRANSVERSE BOT BARS. 221, #5x 36111 242411 @ 12"o/c WALL TO LID DOWELS, 222. (3(44 LONG AS SHOWN, 223. #5@12"o/c TYP WALL HORZ REINF, Z O H a c� J d d a ca W a � 0 o z o U � � o a 0 W LPL WZ p O W CO W y 0 N W OM 0 N � o _ � � o y a E 8 i c � �0 E c m _Ile m am0 Y 0 cZa o C a o 3 ix: W Q a d cc C G 20744 Fss�0Na1. ~ o CD a z > _ W Z a 3 2 O H F. cc Z a W a W ao cccc G ~ a z Z 3 o 0 0 W CC 0 W O I.. r c) C.) Z 40 U) J c a CO) Q J a� SHEET: C REVIEWED: Cameron Partlow, PE DATE 08.21.2020 ENGINEERING S30F 3 civil & structural REVIEWED AND APPROVED engineering & planning FOR GENERAL CONFORMANCE S-19-087