Loading...
OVWSD-EdXing Submission 08-10-2020U .� a, m 0 D J 4 a c�i I 0 0 CAI r; Q THE NW 1/4 OF THE SW 1/4 OF SEC. 31, T 27 N., R4E. EDMON DS APARTMENTS WATER &SEWER PLAN An Engineering Services Campeny s AUGUST 7, 2020 1724 VlCest Marine View Drive, Suite 140 ENGINEER Everett, VIlA 98241 p. 425.486.6533 � f . 425.486.6593 Civil � Structural � Planning � Survey www. paceengrs.com PACE ENGINEERS 1724 W. MARINE VIEW DRIVE #140 EVERETT, WA. 9$201 {425) 486-6533 ex. 1 D1 Bil IHeC�Dpaceengrs.com CONTACT: BILL HELSLEY, PE � RIM 393.64 �} �•� . IE(14") 389.31 SE-N1N ��.� � . IE(8"} 389.91 SW I •� . i / � `. 1 � � � � I 1 � � E�" SSCO PER 01+ � $TD DETAIL S-2 � 1 cTYP} i � / I i �` / i , c J/ !- /�� � � 2 °� 01 ;, ��-r�SSEi � �vws � � 3.0' ,�� � .F' � T INDI( � / �� s.s' �:. `.ACNE �, �/ � \ � ^ ,: A � � � \ } ,��Q�� i � �./ , �\ � _ 112� �� \ x� i , � } �, �., ----�- ._._ � . e ... _.� �f ... ... ....., �' � FENCE CRN. � �-�' 3. �' Wes. s ° N � � .-� PROPOSED 400 � . \ .................. 6 .. STORM -...................................:............... • ...: 400 :PROPOSED GRADE C� EXISTING GRADE C� PIPE CENTERLINE PIPE CENTERLINE PROPOSED 12" STORM EXI STI N G 20 LF 6" SS 5-2.00q 21 !�F_.6"..SS..S=�.00�..... 8"; SEWER 390 :......... ............................. ... . - 390 SSCO 2 = SSCO 1 RIM=398.D0 � � RIM=395.63 IE=389.12 (6"SW) 6" SEWER STUB IE=389.51 (6 NE): IE=389.12 (6"NE} : IE=388.71 385 �------------------------------��---�---=--------...............................:...................: 385 1 +40 1 +50 SEWER PROFILE SURVEYOR APPLICANT GEODETIC SURVEYING SERVICES HAYNES WILSON LUND ARCHITECTS, LLC P.O. BOX 133 385 101ST AVENUE SE MUKILTEO, WA 98275 BELLEVUE, WA 98004 (425} 299-1739 (425) 643-3921 CONTACT: RICHARD VAISVILA, PLS hwlarchC�comcast.net CONTACT: HAYNES LUND, AIA � �� 1 .� � •� �� . \ `� - \ - �``a _ _ _ ��\ EX. �S M - ��� `� RIM. 39.5.15�. � � `,� �0 �` � � ;� � �``�` \ �� �� � � �° STA•� , ;� +56.24 . 18.25 RT} _ ' � 6" SIDS SEWER TE PER STD �� DETAILS 2,., CUT-�11~J- E. 2�*� ` TAPPING INTO.�EX. MAIN �`:� � flNt�Y � IF IT IS �`PV�. vvv ��. vv v -`'� \ \ ` �; ssco # 1 � �., . � 5TA 10+60.71 � � � � `. • � (6.49 LT) STA 1 D+80.1 �-�:�� ;,00 ART) �� �, ° 4 * 1-8''Xfi" TAPPING ..TEE (FL} �`�, �® . . ��. yob 1 �6�, GATE VALVE (FL�MJ} o . � • .\ , p� 1-HYDRANT ASSEMBLY STQ.,. D IL W�2 - 1-THRUST BLOCKING , �' �, �, _ � \\ . - _ 1 y h,a , \ � `: � • � ,PROPO��D 2" WATEf� ,`�, - � METER PER OVWSD '� \ `� � --- 2" CHECK VALVE � �, . "* ,, � STD ••.DETAIL W-1 �.� °`� �, � A55I=MBLY PER ��8 �� ,,� , � OVWSD .STD DETAIL � � , ��� \� � � � �`�� � ��. � � EXISTING �ATER �\� �� :. o� 0., ,� ,, � METER TO BED. �\. �/Q . \ �� , � t �, : � � `�,` \ � � � ,REMOVED & � � - � S �� 1 ��. a a '�`�,, � � � SERVICE, ABANDONED ,,ww 'v - ` AT TH � �IAI N � � � � `�, � j� e r� C ..�\ *V-�`=tip. "`�. `� •'•�� s1 �-' . � _ �, �� \ NOTES: 1. THE TYPE OF BACKFLOW ASSEMBLY REQUIRED WILL BE DETERMINED BY THE DISTRICT'S CROSS CONTROL SPECIALIST AFTER A REVIEW OF THE CONDITIONS AND HAZARDS ASSOCIATED WITH THE NEW BUILDING/FACILITY. 2. THE EXISTING SIDE SEWER MAY BE RE -USED IF IT IS IN ACCEPTABLE CONDITION. IF THE EXISTING SERVICES IS TO BE RE -USED, THEN THE CONDITION OF THE SIDE SEWER SHALL BE ASSESSED, AND A VIDEO INSPECTION SHALL BE PROVIDED TO THE DISTRICT FOR REVIEW. THE DISTRICT MAY REQUIRE THE SIDE SEWER BE REPLACED. 3. ANEW 6-INCH SIDE SEWER SHALL BE PROVIDED IF THE EXISTING SERVICE WILL NOT BE RE -USED OR IS IN POOR CONDITION. IF NOT ALREADY ACCOMPLISHED, THE EXISTING SIDE SEWER SHALL BE CUT AND CAPPED AT THE ROW LIN1=. 4. THE NEW 6-INCH SIDE SEWER TEE WILL NEED TO BE A CUT -IN (WITH PVC SPOOL AND ROMAC COUPLINGS) UNLESS THE EXISTING SEWER MAIN IS PVC. IT IF IS PVC, THEN A SADDLE AND TAP IS PERMISSIBLE. /� � �. /�' • \ �- \ . .1. �`. � a � `� `� � �°,� �'� �- ` �� � ,��\ '� � �� 4 5 0 5 10 1 "= 5' Vertical Scale Feet 1 0 0 10 20 � "= � o' Horizontal Scale Feet N VICINITY MAP 1"=2000' � ?f � y�S � � � co SW psw N �'9�.. m 228TH sT sw 228T � � ro > a �� � �� PROJECT °� � LOCATION � a ss Lake � z�aTH sT sw Ballinger O s 0 ��� 244T sr sw N 24 TH 10 N 24 H N 200TH s ZZ � Z � w Z w a w 4 z a w o ¢ � '� m o w a M � � w z � D N AI o 0 R BFAC ¢ � ¢ '� a s PROPERTY INFORMATION ADDRESS: 23830 EDMONDS WAY EDMONDS, WA 98026 TAX PARCEL: 00463301000302 ZONING: RM-1.5 LEGAL DESC: ALL THAT PORTION OF TRACTS 3, 4 AND 5, BLOCK 10, HANBURY'S SOUND VIEW TRACTS, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 7 OF PLATS, PAGE 20 RECORDS OF SNOHOMISH COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS; BEGINNING AT A POINT ON THE SOUTH LINE OF THE ABOVE SAID TRACT 5, NORTH 89'45' EAST ALONG SAID SOUTH LINE, 80.00 FEET FROM THE SOUTHWEST CORNER OF SAID TRACT 5, THENCE 89'45' EAST ALONG SOUTH LINE OF SAID TRACTS 5, 4 AND 3, A DISTANCE OF 271.95 FEET TO A POINT ON THE SOUTHWESTERLY MARGINAL LINE OF SECONDARY STATE HIGHWAY N0. 1--W; THENCE NORTH 51' 12' WEST ALONG SAID SOUTHWESTERLY MARGINAL LINE 220.03 FEET; THENCE SOUTH 36'44'20" WEST 173.08 FEET TO THE POWT OF BEGINNING OF THE TRACT OF LAND HEREIN DESCRIBED. EXCEPT THAT PORTION CONDEMNED IN SUPERIOR COURT CAUSE N0. 116066 FOR SR 104. SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. SURVEY INFORMATION VERTICAL DATUM: NAND 88 dl0 z �_ 7 w m � m m m � � o � o zo`zo3i;3Q to y a. d a a n o0 .. BENCHMARK: WSDOT BENCHMARK N0. GP3i099 ELEV. = 431.915 BASIS OF BEARING: THE LINE BETWEEN THE MONUMENTS AT THE INTERSECTION OF 238TH ST. SW. WITH EDMONDS WAY AND E. MONUMENT OF 86TH AVE W AS DEPICTED .. HEREON BEARING N89'44'26"E U Know what's below. Call before you dig. N 20' 0 20' 40' 1 "= 20' Scale Feet APPROVED F'OR CONSTRUCTION OLYMPIC VIEW WATER &SEWER DISTRICT DATA: F3�%O��OZO � � is y cV v � c7 � O � ¢ y � u '�. � �� r o _ � y � � �r a ��� � � - � F�. � � . � � � �� �� r?? �� f� s y �4�,�� � a :� o � � � � � � � � � � U L � cM � � � �QCO U �� ��� �� :cn � � _' � N �w >� :U 3 n -� s`u �. w Z � oZ � �' n Z 4 w N .� W W Z a J a oc w 3 w w H a C6.0 z Y 0 oc 0 Y W Z z z V otr � � U R:\Projects\410 (LZG Construction}\002-18 (Edmonds Apt)\Dwg\sheets\Olympic View WBcS\EW-utQl.dwg 34x22 THE NW 114 OF THE SW 1I4 OF SEC. 31, T 27 N,, ROE. V .� >, m 0 -� (n J r1. LCj C] cV I N C7 N 0 1"SADDLE &': CORP. FiWLSHED GRADE 2" SADDLE AND 2" CORP � _ STOP AT MAIN METER SETTER �`' :_ :�.�+ HORIZONTAL bR VERTICAL INLET ���� METER TO BE SUPPLIED AND INSTALLED BY DISTRICT. METER AND SETTER TO BE CENTERED VERTICALLY &HORIZONTALLY IN BOX. VALVE BOX W/SLIDE EXTENSION. ALIGN THESDIRECTION THE FIRE HYDRANT W// MAIN IS INSTALLED. BLUE,DOUBLE-SIDED MARKER 4" STORZ ADAPTER PLACE OFF CENTER OF ROAD CONNECT TO PRIVATE SERVICE. TOWARDS H1fD, I I /I\ II� �.: E I 0.. PER MANUFACTilRER5 A. SERVICE SADDLE RECOMMENDATIONS 6. CORPORATION STOP, 1 " OR 2" C. COPPER TUBING, 1" OR 2" 10 MIL, PLASTIC BETWEEN p, COPPER METER SETTER HYDRANT, BLOCKING AND • � ,x,•S? �•' `i' ' SETTER E. METER BOX OVER WASHED ROCK 3"x3'x4" F. COMP. x COUPLING {HORIZONTAL 1/4 C.Y. 1-1/2" CONCRETE PAG ES OR VERTICAL INLET} WAS}IED ROCK CON NOTE: REFER TO OVWSD APPROVED MATERIALS � � � LIST FOR MATERIALS TO BE USED. � , 4. METER TO Bf SUPPLIED AND INSTALLED BY DISTRICT .. ;; l CENTER METER IN BOX, VERTICALLY AND HORIZONTALLY. IN SAN[ OLYMPIC VIEW WATER &SEWER DISTRICT _REVISIONS STANDARD DETAIL WATER METER AND SERVICE I'' & 2' �� C❑NNECTI❑N DETAIL ... ... pATE ..: :SCALE ;� RWG NR. ......, ._ w. 10/16/18 ......NTS !. ` W--1 MIN 12" CLEARANCES AROUND ADEQUATE GRAVITY BAGKFLOW PREVENTER -ALL 12" MIN DRAINAGE SYSTEM REQUIRIID is '' SIDES, TOP AND BOTTOM ' S' MAX W/ APPROVED AIR GAP ! � .�� GROUND°� LOOR �� ` ;. NOTES: SIDE VIEW; 1. APPROVED REDUCED PRESSURE BACKFLOW ASSEMBLY TO LAY HORIZONTAL ONLY. '�, 2. DESIGNED FOR BACK SIPHONAGE AND BACK PRESSURE. �� 3. THOROUGHLY FLUSH LINES PRIOR TO INSTALLATION 4F BACKFLOW PREVENTER. 4, DO NOT INSTALL IN AN AREA SUBJECT TO FLOODING. �, 5. MusT BE AccEssiBLE. is 6. MUST BE PROTECTED FROM FREEZING CONDITIONS. �: E 7. THE BACKFLOW ASSEMBLY SHALL BE A STATE APPROVED MODEL. �'! 8. MUST BE TESTED AFTER INSTALLATION ANp YEARLY THEREAFTER BY WASHINGTON f' STATE CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST RESULTS MUST BE SENT TO THE DISTRICT. (ABOVE GROUND INSTALLATION ONLY) OLYMPIC VIEW WATER &SEWER DISTRICT I! REVISIONS STANDARD DETAIL OLYMPiC_V>I�W ' '� . _ ASSEMBLYP2� AND SMALLER ❑CRPBA) - -- -- ---- - � _- ':.�_ .�.R . .,�._�s......:..: RATE SCALE - - RWG M0. ��i 10/16/18 NTS W-12 li 3 FITTINGS OR THRUST BLOC 4" x 4" x $' BRICKS UNDISTURBED EARTy, 1'YPECAL 6" FE.;4iVGED TEE RESTRAINEQ F1TifNGS ,,. A." x 4" x 8" BRICK D.I. PIPE, SIZED PER RUN FROM MAIN SEE DESIGN GUIDELINES . 6" RESILIENT WEDGE GATE VALVE NOTE: REFER TO OVWSD APPROVED MATERIALS LIST FOR MATERIALS TO BE USED. �.. OLYMPIC VIEW WATER &SEWER DISTRICT �, REVISIONS STANDARD DETAIL D�.YMP>CC VIBti�l 1-IRE HYDRANT ASSEMBLY DETAIL RATE ... ;SCALE .... .. RWG N0. 10/16/18 ! NTS W-2 SIDE SEWER SPECIFICATIONS 1. ALL PRIVATE SIDE SEWER CONSTRUCTION REQUIRES A PERMIT AND THE PAYMENT OF A FEE. THE PERMIT APPLICATION WILL REQUIRE THE CQMPLETE LEGAL DESCRIPTION, ADDRESS, AND THE DIMENSIONS OF THE PROPERTY TO BE SERVED. 2. ALL CONSTRUCTION IN THE PUBLIC RIGHT-OF-WAY MUST BE DONE BY A LICENSED SEWER CONTRACTOR, AFTER PAYMENT QF ALL APPLICABLE FEES AND PERMITS ISSUED BY AGENCY OF JURISDICTION. 3. ALL WDUSE PLUMBING OUTLETS MUST BE CONNECTED TO THE SANITARY SEWER. 4. NO DOWNSPOUT, FLOOR DRAINS, OR STORM DRAINAGE MAY BE CONNECTED TO THE SANITARY SEWER. 5. MATERIAL PIPE -GASKET JOINTED PVC-5DR 35 OR ASTM D-3034 -GASKET JOINTED DUCTILE IRON CLASS 50 FITTINGS-GASKETED PVC ASTM D-3034 --DUCTILE IRON MJ AWWA C153 CALL FITTINGS �T BE GASKETED 6. MINIMUM SLOPE: 4-INCH DIAMETER PIPE - 2$ (1/4 INCH FALL PER FOOT) 6-INCH DIAMETER PIPE - 1% MINIMUM GRADE MAXIMUM SLOPE: ALL PIPE 50� 7. PIPES SHALL BE LAIp TN STRAIGHT LINE BETWEEN BENp5. MAKE ALL CHANGE IN LINE OR GRADE WITH LESS THAN OR EQUAL TO 45 DEGREES. 8. INCRI=ASES IN PIPE SIZE SHALL BE MADE BY MANUFACTURED FITTINGS. 9. PIPE SHALL BE BEppEp FROM UNDISTURBEp TRENCH WALL TO UNDISTURBED FRENCH WALL ON EACH SIDE OF THE PIPE AND FROM 2 INCHES BELOW TO 2 INCHES A{iOVE THE -PIPE WITH PEA GRAVEL. 10. TWE SIDE SEWER SHALL BE INSPECTED BY DISTRICT STAFF PRIOR TO BACKFTLLING. THE SIDE SEWER SHALL 6E PLUGGED AND TESTED BY FILLING WITH WATER OR AIR. LEAKAGE RATE SHALL NOT EXCEED 0.31 GAL/HOUR FDR 4-INCH PIPE AND 0.47 GAL/HOUR FDR S-INCH PIPE, PER 100 FEET OF PIPE FOR WATER OR MU57 MAINTAIN 4 POUNDS OF PRESSURE FOR A MINIMUM OF FIFTEEN (15) MINUTES. A DISTRICT INSPECTOR SHALL OBSERVE REMOVAL OF THE PLUG. 11. SEWER LINES SHALL NAVE A DISTRICT APPROVED GLEANOUT INSTALLED AT EVERY COMBINATION OF FITTINGS TOTALING 90 6EGREES, AT LEAST EVERY 10O FEET, AT EVERY INCREASE/DECREASE IN PIPE SIZE, AND NO MORE 'THAN 3 FEET FROM THE FOUNDATION OF THE BUILDING. 12. A 6-INCH SIDE SEWER WILL BE ALLOWED TO SERVE A MAXIMUM OF SIX {6} SINGLE-FAMILY RESIDENCES, 13. A 4--INCH SIDE SEWER WILL BE ALLOWED TD SERVE ONLY ONE (1) SINGLE-FAMILY RESIDENCE. 14. PARALLEL WATER AND SEWER TINES SHALL BE SEPARATED BY 10 FEET HORIZONTALLY WHENEVER POSSIBLE. WATER AND SEWER LINES SHALL HAVE A VERTICAL SEPARATION OF 18 INCHES IF A CROSSING IS NECESSARY. THE SEWER LINE SHALL NOT CROSS OVER THE TOP OF A WATER LINE. 15. RIGHT-OF-WAY RESTORATION SHALL EQUAL OR EXCEED THE ORIGINAL CONDITION, AS APPROVED BY AGENCY OF JURISDIcnDN. 16. TRENCH BACKFILL UNDER PAVED AREA SHALL BE 5/8-INCH MINUS CRUSHED SURFACING TOP COURSE; FULL TRENCH DEPTHS COMPACTED IN 12-INCH LIFTS. 17. TEMPORARY REPAIRS OR ABANDONMENT OF A SIDE SEWER REQUIRE THE SIDE SEWER TO BE CUT AND CAPPED AT THE EASEMENT/PROPERTY LINE. CAP TO BE PVC PLAIN END PLUG OR OTHER APPROVED WATERTIGHT PLUG. 18. CONNECTION OF A SIDE SEWER TO AN EXISTING OR NEW STUB REQUIRES A CLEANOUT INSTALLED AT THE EASEMENT/PROPERTY LINE. OLYMPIC VIEW WATER &SEWER DISTRICT REVISIONS STANDARD DETAIL 0>�YNC1'tC`V��W SIDE SEWER SPECIFICATIONS DATE SCALE RWG N0. 10/25/18 NTS S-1 SUBSEQUENT BAGKFILL' INITIAL BACKFILL ;SEE TRENCH SURFACE RESTORATION DETAIL WIDTH EQUALS PIPE O.D. +16" FOR MAIN LINE CONSTRUCTION OR '24" OR LESS FOR SERVICE LINE 1. iNSTALLATIOIV_ - NOTE: ASPHALT RESTORATION SHALL BE IN ACCORDANCE W/ AGENCY OF JURISDICTION for: SNOHOMISH COUNTY CITY OF EDMONDS TOWN OF wooDWAY BACK FILL MATERIAL SHALL CONSIST OF: 1. 5/8" MINUS CRUSHED GRAVEL COMPACTED TO 95% MAXIMUM DRY DENSITY ASTM D638 METHOD "D" UNDER ASPHALT FOR STREET CROSSING. 2. TYPE "C" MATERIAL WITH CLASS II PLACEMENT AND COMPACTION FOR UNDER ASPHALT RUNNING PARALLEL WITH STREET. 3. TYPE "C" MATERIAL WITH CLASS I PLACEMENT AND COMPACTION FOR STREET SHOULDERS. 4. TYPE "D" MATERIAL WITH CLASS III PLACEMENT AND COMPACTION FOR ALL OTHER AREAS. OLYMPIC VIEW WATER &SEWER DISTRICT REVLSIONS STANDARD DETAIL ,w, TRENCH DETAIL . - �,-,..:. DATE SCALE - i RWG N0. 10/16/18 NTS W-6 (FOR FUTURE DEVELOPEMENT} PLACE 2X4 AT END OF SIDE SEWER STUB AND CUT TO LENGTH TO INSURE 3 FEETI�KTENDS ABOVE GRADE. PAINT TOP 1$ INCHES WHITE. IN 3 INCH hIIGH LETTERS STENCIL THE NUMBER OF EVEN FEET FROM GROUND ELEVATION TO THE SEWER STUB INVERT. 8 GAUGE WIRE TO BE DOUBLE WRAPPED AROUND PIPE AND 2X4 STAKE AT OR ABOVE FINISHED GRADE. w z LOCKING LAMPHOLE COVER � TO BE PLACED AT FINISHED � GRADE (SEE STD SEWER w CLEANOUT DETAIL) a la a. 1 z I I 6" WYE AND 45' BEND 0 ;�, 6" LATERAL SEWER LINE / SLOPE- 50%MMAX TO PVC PLAIN END OR OTHER APPROVED WATERTIGHT PLUG 22.5' OR �� 45' BEND N 0 T E: WHEN TAPPING INTO EXISTING MAIN, CUT IN A NEW TEE W/ MECHANICAL COUPLINGS. USE OF A SADDLE AND TAP IS ALLOWED ONLY ON PVC MAINS. PLACEMENT OF TEE SHALL DEPEND CN DEPTH OF SEWER MAIN. AS A MINIMUM, THE TEE SHALL BE PLACED AT A 45 DEGREE ANGLE. 6" TEE POSSIBLE SEWER MAIN LocATION 6" TEE /POSSIBLE SEWER MAIN LOCATION OLYMPIC VIEW WATER &SEWER D1STRfCT REVISIONS STANDARD DETAIL TYPICAL SIDE SEWER DATE SCALE RWO N0. 1O/25/18 NTS 5-2 .. .. Ma � j TEST COCKS �i (4 REOUIR ) :� 'I� '� _ I i i TOP VIEW METER BOX EXIST GROJUND „jI RESIDENT SEATED SHUTOFF ' ' -:,I. it _ _...----------- i I [- I SIDE VIEW GRAVEL (12" MIN 1. APPROVED DOUBLE CHECK VALVE ASSEMBLY TO LAY HORIZONTAL WITW GROUND. 2. pESIGNED FOR BACK 5EPHONAGE ANp BACK PRESSURE. 3. TEST COCKS TO EITHER FACE OUTWARDS OR UPWARDS FROM ASSEMBLY. 4. ALL TEST COCKS MUST BE PROVIDED WITH PVC PLUGS OR EQUAL. 5. THOROUGHLY FLUSH LINES PRIOR 70 INSTALLATION OF BACKFLOW PREVENTER. fi. THE OCVA CAN BE INSTALLED A60VE OR BELOW FIiE GROUNp PROVIDED ALL CLEARANCES ARE MET. 7. lm NOT INSTALL IN AN AREA SUBJECT TO FLOODING. 8. MUST BE PROTECTED FROM FREEZING CONDITIONS. 8. BRAND, MODEL AND SERIAL NUMBER OF ASSEMBLY MUST BE CLEARLY VISIBLE. 10. THE BACKFLOW PREVENTION ASSEMBLY MUST 6E Ai'pROVED BY WSDOH/USC. -MUST SE TESTED AFTER IIVSTALLA710N AN17 Y�4Ri1' THEREAFTER BY A WA5NlNGTON STATE CERTIFIED BACKF'LOW ASSEMBLY TESTER. TFfE TEST REPORT MUST 8E SENT TO THE QISTRICT. <. OLYMPIC VIEW WATER &SEWER DISTRICT ,REVISIONS. STANDARD DETAIL OLYMPIC'V[£W D❑UBLE CHECK VALVE ASSEMBLY UP TO 2' _ _. _, ..._.T_.a._ - _ RATE SCALE 61Wi NO.. 10/16/18 NTS W-11 NOTES: 1. MANHOLES SHALL BE CONSTRUCTED IN ACCORDANCE WITH AASHTO M199 UNLESS OTHERWISE SHOWN ON PLANS OR NOTED IN THE WSDOT/APWA STANDARD SPECIFICATIONS. 2. HANDHOLDS IN ADJUSTMENT SECTION SHALL HAVE 3" MIN. CLEARANCE. STEPS IN MANHOLE SHALL HAVE 6" MIN. CLEARANCE. SEE DWG. N0. 2-01 1, "MANHOLE DETAILS." HANDHOLDS SHALL BE PLACED IN ALTERNATING GRADE RINGS OR LEVELING BRICK COURSE WITH A MIN. OF ONE HAND HOLD BETWEEN THE LAST STEP AND THE TOP OF THE MANHOLE. 3. ALL REINFORCED CAST -IN -PLACE CONCRETE SHALL BE GLASS 4000. ALL PRECAST CONCRETE SHALL BE GLASS 4000. NON -REINFORCED CONCRETE IN CHANNEL AND SHELF SHALL BE CLASS 3000. 4. PRECAST BASES SHALL BE FURNISHED WITH CUTOUTS OR KNOCKOUTS. KNOCKOUTS SHALL HAVE WALL THICKNESS OF 2" MIN. UNUSED KNOCKOUTS NEEf) NOT BE GROUTED IF WALL IS LEFT INTACT. PIPES SHALL BE WSTALLED ONLY IN FACTORY KNOCKOUTS UNLESS OTHERWISE APPROVED BY THE ENGINEER. 5. KNOCKOUT OR CUTOUT HOLE SIZE SHALL EQUAL PIPE OUTER DIAM. PLUS MANHOLE WALL THICKNESS. MAX. HOLE SIZE SHALL BE 36" FOR 48" MANHOLE, 42" FOR 54" MANHOLE, 48" FOR 60'' M.H. MIN. DISTANCE BETWEEN HOLES SHALL BE 8". 6. MANHOLE RINGS AND COVERS SHALL MEET THE STRENGTH REQUIREMENTS OF CURRENT FEDERAL AND STATE SPECIFICATIONS. MATING SURFRCES SHALL BE FINISHED TO ASSURE NON -ROCKING FIT WITH ANY COVER POSITION. 7. ALL BASE REINFORCING STEEL SHALL HAVE A MIN. YIELD STRENGTH OF 60,000 PSI ANT] BE PLACED IN THE UPPER HALF OF THE BASE WITH 1" MIN. CLEARANCE. 8. FOR HEIGHTS OF 12' OR LESS, MIN. SOIL BEARING VALUE SHALL EQUAL 3,300 POUNDS PER SQUARE FOOT. FOR HEIGHTS OVER 12', MIN. SOIL BEARING VALUE SHALL EQUAL 3,800 POUNDS PER SQUARE FOOT. 9, NEW MANHOLES SHALL NOT HAVE METAL RISERS INSTALLED TO MEET FINAL GRADE. OLYMPIC VIEW WATER &SEWER DISTRICT REVISIONS STANDARD DETAIL OLY�P><C�'i�t�i MANHOLE SPECIEICATIC]NS GATE SCALE OWG N0. 10/25/18 NTS 5-46 Know whaf's below. Cali before you dig. APPROVED FOR CONSTRUCTION OLYMPIC VIEW WATER &SEWER DISTRICT DATE: �.3 /O 2vZb ri u T 1'M u �,, m � m �. m m d � O � d C � � N � �C � � _ 'ffJ � � _ 03 d C. !� ��.. z o z a� v 3 Q o 0 °' � m N � I N o �„ � o '� si .� iC E o a� .o I 2 E � � a d V d) M A N U] � � :� o � � � a� � _� c � o N�ti' o - a � �¢c�ra, � � � � � � Cn tZ L�fi � � N - � � � '7 c n E 3 w ,�, � V Z O OG Z Y 11,I � W � c Z � � Z 4 Q _ � Ell n Z V � l�li Ex N � � p �..) a W h� � W W C!] � O�f O W Q W C6.1 R:\Projects\410 (LZG Construction)\002-18 (Edmonds Apt)\Dwg\sheets\Olympic View WBcS\EW--utdt01.dwg 34x22