Loading...
REVIEWED RESUB1 BLD2022-1184+STRUCTURAL PLANS+1.2.2023_10.44.57_AM+3293021The following documentation shall be available on . ' I ite for the building inspector: ■ ; X❑ COE APPROVED ARCHITECTURAL PLAN SET '. ■ ❑ COE APPROVED STRUCTURAL PLAN SET ; ❑ COE REVIEWED CALCULATION PACKET ❑ ENERGY CREDIT WORKSHEET '. ❑ SITE PLAN ■ ❑ CIVIL PLAN ; ❑ ■ ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ; APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE GENERAL STRUCTURAL NOTES CODE All conditions, materials and construction shall conform to the code specified in the DESIGN CRITERIA, or other codes required by the governing jurisdiction. PROTECTION Through maintenance and current best practices, provide a building envelope that will preserve the integrity of the structure throughout it's lifetime. INSPECTIONS Notify Building Department for inspections required by local jurisdiction. SOILS Bearing capacity of soil shall be per DESIGN CRITERIA or greater. Footing shall bear on solid undisturbed level soil devoid of any organic material and below indicated frost line. COMPACTED FILL shall consist of predominately Well -Graded, granular soil, free of organic material and debris. Fill should be placed in maximum 8" loose lifts and compacted to a minimum of 95 percent of the maximum density at optimum moisture content determined by ASTM D-1557 test procedures. BACKFILL shall be free draining and without organic material and debris from one of the following soil classes SM-SC, SM, SP, SW, GC, GM, GP, and GW. FOUNDATIONS AND RETAR04G WALLS Extend footings to undisturbed bearing soil. Do not backfill until all slabs and/or horizontal diaphragms are constructed, otherwise provide temporary bracing to resist movement. CONCRETE f'c = 3000 psi minimum for environmental exposure (2500 psi used in structural design, or unless greater psi indicated on the plans). 5 1/2 sacks of cement per cubic yard of concrete and a maximum of 6 gallons of water per 94 lb sack of cement. Maximum slump is 4". Segregation of materials shall be prevented through proper handling and placement. REINFORCING STEEL #4 bars and larger shall be Grade 60 deformed bars, and #3 bars shall be Grade 40 (u.n.o.), in accordance with ASTM A-615. Lap splices 32 bar diameters u.n.o. Welded wire fabric shall conform to ASTM A-185 and shall be 6x6 - W1.4xW1.4. Lap one full mesh at splices. CLEAR COVER 3" clr when cast against Earth and 2" clr in all other locations, u.n.o. WOOD FRAMING in contact with concrete or masonry, or exposed to weather, shall be pressure treated. Numbers in parenthesis, IE (1-1), refer to corresponding engineering calculations. CONNECTORS AND FASTENERS Fasteners, including nuts and washers, and connectors in contact with pressure treated wood shall be hot -dipped zinc -coated galvanized. EXCEPTION: Plain carbon steel fasteners, including nuts and washers, in SBX/DOT and zinc borate preservative treated wood in an interior, dry environment shall be permitted. SOLID SAWN LUMBER shall meet the following minimum grades (u.n.o.) conforming to "WWPA GRADING RULES FOR WESTERN LUMBER", latest edition: BEAMS, POSTS, RAFTERS, JOIST 6X and wider DF#1 2x 10 and greater DF#2 2x 8 and smaller HF#2 ENGINEERED WOOD shall meet the following minimum properties: Callout E x 106 (psi) Fb(psi) Fc ar(psi) Fc perp (psi) Fv(psi) GLB 1.8E 2400 1650 650 240 All cantilevered and multi -span glue -laminated beams (GLB) shall be V8 unless noted otherwise, additionally cantilevered beams shall have zero camber. Engineered wood products shall be protected from moisture to preserve their structural integrity. Provide temporary bracing to avoid permanent deflections resulting from drying under construction dead loads. BEAM PENETRATIONS Allowable beam penetrations shall be made in the middle third of the span and the middle third of the depth. Contact this office for any penetration outside the allowable area. See applicable detail(s): BP CONNECTIONS and fasteners shall be per CODE Table 2304.10.1 u.n.o. The symbol, "#", indicates a hardware connector from the most current Simpson Strong -Tie Catalog. Hardware with equivilent or greater capacities from other manufacturers may be substituted, example you can use USP's Dual Specification Chart to make an equivilent or greater capacity selection. Install per the manufacturer instructions. Fasteners and hardware in contact with pressure treated wood shall be hot -dipped zinc -coated galvanized. NAILS All nails shall be "Standard Common" size per the latest edition of the National Design Specification for Wood Construction (NDS) u.n.o. POST CAPS Provide a post cap on isolated columns that most nearly matches the actual member size(s) U.N.O. Each connection shall have a minimum of (3)10d to the post and (3)10d to the beam. HANGERS Model numbers will be specified on the plans for conditions that require more than minimum capacity, otherwise see CONNECTIONS. When a hanger is not specified on the plans, use any size specific model number that fits that member. Always use MAX NAILING. Hanger to match member size. Notching or shimming of beam not allowed unless specified. JOBSITE SAFETY Sound Structural Solutions Inc has not been retained or compensated to provide design and/or construction review services related to the contractor's safety precautions or to means, methods, techniques, sequences or procedures for the contractor to perform their work. The undertaking of periodic site visits by the ENGINEER shall not be construed as supervision of actual construction and not make him responsible for providing a safe place for the performance of work by the contractor, subcontractors, suppliers or their employees, or for access, visits, use work, travel, or occupancy by any person. OWNERSHIP OF DOCUMENTS These drawings and calculations are the intellectual property of Sound Structural Solutions Inc. These drawings may not be used in whole or in part by any person without permission of Sound Structural Solutions Inc. MISCELLANEOUS The contractor shall verify dimensions and conditions at job site. The contractor shall provide temporary bracing as required until all permanent connections and stiffenings have been installed. Do not scale drawings. Pre -fabricated items to be handled and installed per manufacturer's recommendations. Basic Wind Speed (3 sec gust) mph 98 Surface Roughness C Wind Exposure Category C PLAN INSTRUCTIONS READ THIS FIRST These plans are organized so that more detailed or specific information is found in the same way by following the direction shown below: GENERAL STRUCTURAL NOTES SCHEDULES, DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES for more specific information. SCHEDULES DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES and SCHEDULES for more specific information. DETAILS PLANS will often refer to GENERAL STRUCTURAL NOTES, SCHEDULES and DETAILS for more specific information. PLANS See the SYMBOL LEGEND as well as ABREVIATIONS AND ACRONYMS for other additional information used on the PLANS. The term, TYPICAL (or TYP), used with a detail callout or plan note, indicates that the information specified shall apply in all similar conditions. IF YOU HA VEANY QUESTIONS OR CONCERNS CONTACT US IMMEDIA TEL Y.l We can be reached immediately by phone: (425) 778-IL023 For less pressing questions, email us: inbox@ssseng.com Please help us get to your plans by having this job number handy: s2209023 ABBREVIATIONS AND ACRONYMS ABV ABOVE E.S. EACH SIDE O.C. ON CENTER A.B. ANCHOR BOLT E.W. EACH WAY P.T. PRESSURE TREATED BLW BELOW EA EACH REINF REINFORCEMENT BLK BLOCK E.N. EDGE NAILING REQD REQUIRED BLKG BLOCKING EMBED EMBEDMENT SCHED SCHEDULE B.N. BOUNDARY NAILING EXIST EXISTING SIM SIMILAR BTM BOTTOM FDN FOUNDATION STD STANDARD BRIG BEARING FLR FLOOR STRUCT STRUCTURAL BTWN BETWEEN FRMG FRAMING SW SHEARWALL CLR CLEAR FTG FOOTING THRU THROUGH CLTR COLLECTOR G.T. GIRDER TRUSS T.R. THREADED ROD CONIC CONCRETE GR GRADE TYP TYPICAL CONN CONNECTION HORIZ HORIZONTAL U.N.O. UNLESS NOTED CONT CONTINUOUS MAX MAXIMUM OTHERWISE CTR CENTER MFG MANUFACTURED VERT VERTICAL DBL DOUBLE MIN MINIMUM w/ WITH DET DETAIL o/ OVER w/o WITHOUT E. E. EACH END oc ON CENTER W.W.F. WELDED WIRE FABRIC DESIGN CRITERIA Governing Code 18 IBC Risk Category II Wind Design Data Earthquake Design Data Gravity Load Data loads are psf Dead Live Snow Decks: loads are psf Dead Live Snow Joists5 20 60 25 Notes apply as called out in table above. 5 Joists of sawn lumber or wood I -joists. Assumed Soil Data Allowable Soil Bearing 2000 psf Seismic Importance Factor, Ie 1.00 Site Classification D 1-Second Acceleration, S1 0.451 Seismic Design Category D Spectral Response Coefficient, Sps 1.026 Spectral Response Coefficient, SD1 0.556 Seismic Force Resisting System Table 12.2-1: A-15 2016 Equiv. Lateral Force Procedure SSS Number: s2209023 Project Name: 569 Hemlock Way Owner: [Dean Adams] Project Location: 569 Hemlock Way, Edmonds, WA Design Professional: Michel Design M Z V-) O 1--1 ' F— r1 Q w � J W � Z E O V t-? Z 0 w N O U 01 X O C �` of S ���� Y azzai `14 ��� SjO NA This space reserved for governing jurisdiction stamps silo / RESUB ra Ln Ln LR Jan 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-1184 ORIGIN DATE: 12 21/2022 REVISED; ---- Internal Pressure Coefficient 0.18 Topographic Factor, Kt 1.00 Ground Elevation Factor, Ke 1.00 SSS Number: s2209023 DO NOT MAKE PENETRATIONS OR NOTCHES IN THE SHADED AREA OF THE BEAM WITHOUT PRIOR APPROVAL OF THE ENGINEER MIN CLEAR SPACING SHALL BE 2x THE DIAMETER OF THE LARGER HOLE PENETRATIONS IN THIS AREA DO NOT REQUIRE APPROVAL FROM THE ENGINEER %DEPTH DEPTH % DEPTH O O DEPTH SPAN t %SPAN �� %SPAN SPAN SAWN BEAM PENETRATIONS, TYPICAL DETAIL N.T.S. "O THREADED ROD #DTT2Z w/ (8) 40 x 11 SDS SCREWS DECK JOIST FLR SHEATHING NAILING AT 6" oc (MAX) TO JOIST WITH HOLDOWN FLR JOIST FIGURE 502.2.2.3 DECK ATTACHMENT FOR LATERAL LOADS N.T.S. DALLD SOLID RIM DECKING BY OTHERS CTR OF RIM II 3" TYP, 3" TYP. 1 MIN. 6 %"O x 3" #SDS 2" MAX. TYP. SCREWS @ 6" oc 2x(MATCH JOIST) P.T. LEDGER EXTERIOR DECK LEDGER N.T.S. %" 4 GALV M.B. OR THREADED ROD w/ NUTS & WASHERS (2) #DTT2 w/ A (8)14 x 1 % #SDS ea %" 4 GALV M.B. OR THREADED ROD w/ NUTS & WASHERS (2) #DTT2 w/ B (8) % x 1 % #SDS ea EDLA 4x4 MIN. POST @ 6'-0"oc MAX, TYP 2x8 (MIN) BLKG -1 2" (2) #DTT2 w/ (8) 4 x 1 % #SDS ea TESTED POST -TO -DECK ASSEMBLY BY SIMPSON STRONG -TIE PUBLISHED IN REPORT (T-C-GRDRLPST20) HOLDOWN GUARDRAIL POST APPLICATION N.T.S. 1 8" MIN 2" MIN 18" MAX FTG PLINTH FINISH GR (2) #4 @ w/ STD 18" HOOK IN FTG MIN 48" MAX 3" CLR BRG SOIL PEDESTAL ON ISOLATED FOOTING N.T.S. PIFA HGP Project Name: 569 Hemlock Way Owner: [Dean Adams] Project Location: 569 Hemlock Way, Edmonds, WA Design Professional: Michel Design M [.n (V Z V1 O O r—H 00 c J p w Ln J w z O V_ U H CC V) u7 C z p w 0 U N U) U) V) O S Ft4C� o. z �p R 42771 �p ,CFI FGISTrr—� S NAL \`L This space reserved for governing jurisdiction stamps RESUB Jan 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-1184 ORIGIN DATE: 12/21/2022 REVISED: ---S210 - M N O Q1 0 N N Ln N N CV T cv Y U _O 2 C 1 SSS Number: s2209023 DECK FRAMING PLAN 1/4" = V-0° DO NOT SCALE - REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS Project Name: 569 Hemlock Way Owner: [Dean Adams] Project Location: 569 Hemlock Way, Edmonds, WA Design Professional: Michel Design M � N Z O H o J O w Lf) [.n N J w Z C O L U H Vi cn Z � w L/] O U C N (n 1n (n X O C 5 FLU z 42771 �p 'C+� €-ISTf sS10NAL This space reserved for governing jurisdiction stamps RESUB Jan 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-1184 ORIGIN DATE: REVISED: 12/21/2022 S310