FIR2023-0037_Fire_Alarm_Battery_Calculations_4.13.2023_2.45.09_PM_3482071W I�II i! R:111 flu,1111111 _ �7 i! III U 1/ INSTALLATION OF NEW AES 7707P-88-UPL FIRE RADIO @ 615 GLEN STREET, EDMONDS, WA 98020-3028 CONNECTED TO EXISTING: AES TROUBLE OUTPUT CONNECTED TO EXISTING SYTEM BY THE FOLLOWING METHOD: Zone existing on panel ACCT# LAC857797 C/S: ALARM CENTER RANGE TEST: 7 NETCOM: 5 7067 INTELLITAP: YES 7770 FIRETAP: NO DEDICATED BREAKER: PANEL#: HOUSE CKT#: UNKNOWN /ADRIAN M. STEIK Senior Engineering Technician, Level 4 NICET Certifcation Number: 093706 Authorizing Signature: 6-d i^'� UHF Antenna Options (450-480 MHz) Antenna dB Construction Usage Length 2.5 dB Case Top Flex Tamper Resistant (1 11 2) Vinyl Clad Indoor 11 in. 3 dB Stealth (Not Shown Below) (3) Vinyl Clad Indoor 1.5 ft. 3 dB Standard Gain (4&5) Steel Mast Indoor 1.5 ft. 5 dB High Gain (4) Steel Mast Indoor 3 ft. 6 dB Rugged High Gain(4) Fiberglass Mast In/Outdoor 4.5 ft. 7 dB Rugged Higher Gain(4) Fiberglass Mast In/Outdoor 6 ft. 9 dB Central Station High Gain(') Fiberglass Mast In/Outdoor 6 ft. Notes: 1. This antenna was evaluated by UL and approved for use in a UL 864 Edition 9 system. 2. Included standard Tamper Resistant antenna, mounts on Alarm Unit's enclosure. Includes cable. 3. Mounts in attics, vents, walls, behind drapes, ect. Includes 10-foot cable. 4. Requires cable (See Section 1.10). Usually requires user supplied mounting hardware such as a pole with mounting brackets/hardware. 5. Antenna is intended for outdoor use, supplied mount is intended for indoor use as coax connection is exposed. To use outdoors, connection must be sealed with a suitable product such as a self -fusing tape to protect against moisture. AES FRCP FACP/RDACT LAYOUTS ljoin__2 AES"n CORPORATION CURITY 01111WATutn O FACP ROOM LAYOUT w/ DETECTOR Battery Capaciry Calculator Instructions: 1) Select the AES product from the AES Product field. 2) Select if Ethernet Cable is required during normal operation. This only applies to 2.0 subscribers. 3) Enter the # of hours of backup time required. AES products are UL listed for 24 hours operation on battery backup. 4) The calculator will return the recommended battery capacity. AES Product Ethernet Cable Required 7707P 88-ULP-M Yes Standby Current Ethernet Current Total Standby AlarmfTransmit OTY Total Alarm (Amps) (Amps) Current (Amps) Current (Amps) Current (Amps) 0.348 0.015 — 0.363 0.866 x 1I = 0.868 Total Standby Current (Amps) 0.363 Total Alarm Current (Amps) 0.868 # Hours Backup Standby Current Required Standby Required Alarm Alarm7Transmit Required Alarm TiCapacity me (Amps) (Amp Capacity ys) Time (Hours) I Current(Amps) (Amp -Hours) 24 1 x 1 0.363 8.7 0.25 x 0.868 0.2 Required Standby Required Alarm Total Required Capacity Capacity Backup Capacity (Amp -Hours) (Amp -Hours) (Amp -Hours) 8.7 02 = 8.9 Total Required Recommended Backup Capacity Recommended Minimum Battery (Amp -Hours) Safety Factor Capacity (Amp -Hours)' 8.9 x 120% = 10.7 "The battery requirements presented here are only AES recommendations. For UL listed battery requirements please read the product Installation and Operation Manual.