Loading...
REV 4 APPROVED ENG RESUB1 C5.01.3 REV4 6.24.20PORTION OF THE SW 1/4, NE 1/4, SEC. 29, TWP 27 N., RGE. 4 E., W.M. ool22PcC�� C7 0 C C) Ca N N 370 36° 36( 35! 35( SEI FOR 34� - _ - . ... ....... --- ---- - - - _ -_ -- - -- - - - - -- -- R HYUNDAI SALES & PIV 4GS'i 10 LF 6" DI SPOOL SERVICE BUILDING EXISTING GRADE AT ME/MEGA LUGS) PIPE CENTERLINE DOUBLE DETECTOR CHECK ASSEMBLY IN VAULT PER -INSTALL MEGA LUGS WA- 142B SEE SHEET _ C5.10-3 FF=355.10 -_ _----- -- -- --- _- EXISTING 12" --- --- _ .�--- --STORM MAIN EX. 6" SD IE=351.78 5 LF 6" DI 19 LF 6" WA TOP=350.78 5 LF 6" DI SP006" DI 0 i �11 LF 6" DI CL52 /- ( / ..., _ � _ ..., .,-.. � � � - - -- - --- - - - - -- — .... ,..� — - - ^- - -- - ^ -- - - / MJ W MEGA LUG 94 LF 6" DI CL52 MECHANICAL CONTINUATION o r_� c� cA- ID w w ± o o m mA3 340 -0+25 0+00 TOR VI£W TEST COCKS W'/ PVC PLUGS (4 REQ"D) RESILIENT SEATED SHUTOFF VALVES (2 REQ'D) 1+00 163 LF 6" DI CL52 c� J (n a J 2 Cl z ao ca cri Sri w u�i � Mi �— °D ALL HORIZONTAL BENDS N z °' N N. i Z �r REQUIRE THRUST BLOCKING PER COE N a o o x STD DETAIL WA-150, SEE SHEET C5.10-3 (n ►�- N cn E¢- ❑ N a cn to (n U w IF RPDA, USE SENSUS SR2 — METER W/ TRPL REMOTE READ. TRPL SHALL BE INSTALLED ON SIDE OF HOT BOXWITH EASY ACCESS FOR METER READING. 3" MIN — 3/B"W ANCHOR BOLTS (PER MANUFACTURER) CONCRETE SLAB (2000 PSI MIN) 4" MIN FIRE SERVICE PROFILE SCALE: H: 1 "=20' V: 1 "=5' ENCLOSURE "HOT BOX" OR EQUAL REDUCED PRESSURE BACKFLOW ASSEMBLY (RPBA) 120 VOLT ELECTRICAL OUTLET FOR HEAT TAPE. INSTALL HEAT TAPE FOR FREEZE PROTECTION. IF RPDA, USE SENSUS SR2 METER W/ TRPL REMOTE READ UNION CENTER BACKFLOW PREVENTER IN ENCLOSURE 3" MIN DRAIN SEE NOTE 6 fl .['2" �' (P SLEEVE ® ® FREE DRAINING GRAVE. P TYPE K COPPER 7 SUPPORTS OR APPROVED TYPE K COPPED EQUAL (SIZE AS REQ) OR APPROVED MIN 12m C7PR:EVENTER ROUND ADEQUATE C+RAWI7Y DRAINAGE (TYP) � EQUAL (SIZE AS REQ) BAGKFLOW 1"2" MIN SYSTEM REQUIRED CONNECT TO WATER (�) ALL SIDESOTTOM 6' MAX W/ APPROVED AIR GAP METER IMMEDIATELY ADJACRPRA 1. APPROVED REDUCED PRESSURE BACKFLOW ASSEMBLY TO LAY HORIZONTAL ONLY. 2. DESIGNER FOR BACK SIPHONAGE AND BACK PRESSURE. 3. THOROUGHLY FLUSH LINES PRIOR TO INSTALLATION OF BACKFLOW PREV'ENTER. 4. DO NOT INSTALL IN AN AREA SUBJECT TO FLOODING. 5. MUST BE ACCESSIBLE. 6, MUST BE PROTECTED FROM FREEZING CONDITIONS. 7. THE BACKFLOW ASSEMBLY SHALL BE A STATE APPROVED MODEL. 8. A PLUMBING PERMIT IS REQUIRED — PLEASE CONTACT DEVELOPMENT SERVICES DEPARTMENT.. 9. MUST BE TESTED AFTER INSTALLATION AND YEARLY THEREAFTER BY WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST RESULTS MUST BE SENT TO THE CITY OF EDMONDS WATER DIVISION. (ABOVE GROUND INSTALLATION ONLY) squourram 9 APPROVED BY: R. ENGLISH REVISION DATE JANUARY 2018 STANDARD DETAIL WA— 160A 2+00 MIN 120 VOLT ELECTRICAL OUTLET FOR HEAT TAPE. INSTALL HEAT TAPE FOR FREE PROTECTION. 6 Bxe W2.9xW2.9 WWF (WELDED WIRE FABRIC) TO OWNERS ELECTRICAL PAN@ DIRECT J BURIAL OR IN RIGID CONDUIT PER ELECTRICAL PERMIT REQUIREMENTS NOTES: SIDE VIEW FRONT VIEW (METER SIDE) 1. PROVIDE CITY APPROVES# SUPPORT FOR DEVICES LARGER THAN I DIAMETER. 2. OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE RPBA OR RPDA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. MUST BE TESTED AFTER INSTALLATION AND YEARLY BY A WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST RESULTS MUST BE SENT TO THE CITY OF EDMONDS WATER DIVISION. 4. REDUCED PRESSURE BACKFLOW ASSEMBLIES SHALL BE STATE APPROVED DEVICES, 5. ANNUAL TESTING OF RPSA AND RPDA REQUIRED BY OWNER, TEST RESULTS SHALL BE SENT TO THE CITY OF EDMONDS PUBLIC WORKS. 6. DRAIN SHALL BE SIZED IN ACCORDANCE WITH AWWA CROSS CONNECTION CONTROL FIGURE 6-8 (SEE COE STD DTL WA-1 SOC). 7. ENCLOSURES SHALL. BE LOCATED ON PRIVATE PROPERTY,. 8. SLEEVE SHALL BE ONE NOMINAL SIZE DIAMETER LARGER THAN PIPE BEING %EEVEN?. 0 4 , � � � � r w • f � ■ rr ■ f i � �. IA ,. .flu i i ...�, w lll■ • III r 3+00 EXIST WATER MAIN PROPERTY LINE 370 365 360 355 350 345 —' 340 3+40 SETBACK LINE I L I I� SEE COE STD DTL WA-180 � 2" DOMESTIC SERVICE TIKA (COPPER) WM KA TV 4" (MIN) FIRE LINE (DIP) RESILIENT GATE VALVES MP) _ SEE COE STD DTL.S WA-180 AND WA-181 CURB SIDEWALK FIB I PIN DCOA & VAULT SEE COE S D OTLS WA--142A & 'WA--142B BLDG 1. THE DCDA AND VAULT SHALL BE LOCATED ON PRIVATE PROPERTY AND ADJACENT TO THE RIGHT —CIF —WAY LINE. 2. THE PIV AND FDC SHALL BE LOCATED ON PRIVATE PROPERTY' AND SHALL BE NEAR THE DCDA. 3. THE PIV AND FDC SHALL HAVE A 3' MINIMUM CLEARANCE BETWEEN AND AROUND THEM. 4. THE FDC SHALL HAVE A ;22' BENS WITH 4" STORZ ADAPTER ON THE END. N cV mm (N (N I N I pl) d- NO _j z O z Cl z p z O z p z 0 Q a C n (>N7U75 nU>5c>'n_m � 0 E W W W C�J m� ZD 22Q.:ww '(nU) w w w x w w w w w wcr- w w w w w w CL CL CE d CL 0- C- n- NI•- >1 >1 z m N N O a) � Cl N UaNi U Q <- ry > ❑ -� ❑ ¢ co ❑ REVISION DATE CITY F EDMONDS FIRE LINE AND 2" DOMESTIC JANUARY 2018 0 SERVICE CONNECTIONS (PAN VIEW) PUBLIC WORKS ALL ZONES EXCEPT ZERO -SETBACK STANDARD< DEPARTMENT BUSINESS/COMMERCIAL DETAIL APPROVED BY: R. ENGUSH WAr--18 TON ul 00 W00 Q Na 6) U `r w I m U Lu 0 0 Cd-� m V ,w ^N U' V 0 3 Y I XO 3 Q m 1 O a >_ w _ ►— W = b v = N Q 0U' rn co rn z U) zDoz =zw �MMz 0 Q N W C� W U > ♦W v) > W 06 W � Ll U) REVISION �- _ d Q M M L-L.. JUN 2 4 2020 C] N W BUILDING DEPARTMENTz CITY OFEIJMONOS D CALL BEFORE _ YOU D;G 811 UNDERGROUND SERVICE (USA) APPROVED FOR CONSTRUCTION CITY OF EDMONDS w d 0 w J Q w z = 0 I— 0 0 DATE: BY: CITY ENGINEERING DIVISION C 5.0 1 -31 PERMIT #BLD20190120