REV 4 APPROVED ENG RESUB1 L1.0 6.24.20/0 Rubber Hose Guy wires - 3 per tree flagged for visibility` 2"x2"x24" stakes ---Set crown 2" above finished grade !-Wood chip or bark mulch Form watering well xcavote 2x width of rootball remove burlap from top half of rootball Plant in 50-50 mix of topsoil and native soil 'Tamped soil setting bed \Existing soil Tree Planting Detail applies to shrubs as well no staking necessary for shrubs al . 0 I I I I ! J rp i i I Interior Landscape Calculations I I Hyundai Sales and Service Site 23 stalls @ 17.5 sq.ft./stall = 402.5 sq.ft. ! i 640 sq.ft. provided I i i i ! ......................................... 3 1 r 1 k architecture I design 5.11.20 Existing.perimeter vegetaon to remain R Notes: 3 1 r I karchitecture I design Plant Materials 4 Acer rubrum 'Red Sunset' - Red Maple / 3'' cal. Branched @7' 3 Prunus cerosifero 'Thundercloud' - Purple Plum / 2" cal. 9 Thujo occ. 'Emerald Green' - Arborvitae / 5-6' . O 26 Potentilla fruiticoso 'Goldfinger' - Cinquefoil / 1 gal. 0 46 Nandino dom. 'Gulf Stream' 2 gal. ® 32 Mahonio repens - Creeping Mahonia / 1 gol. 14 Viburnum davidii / 2 gal. rp Rubus pentolobus - Creeping Raspberry / 4" @ 2' o.c. ss Sedum spothulifolium - Stonecrop / 4" @ 2' o.c. do Delosperma 'Coopers' - Ice Plant / 4" @ 2' o.c. All perimeter buffers to be maintained. Amend ail plantings areas with 3" of compost e.g. cedar groves compost or gro-co. Mulch all planting beds with 3" wood or bark mulch. Provide design/build irrigation (permit req.) for all plantings. Follow City of Edmonds Landscape code. Provide sleeves for piping under paths to access all planting areas. Plant substitutions are o.k. if confirmed by landscape architect. Avoid planting in summer months. Stake trees as necessary. A separate irrigation permit must be obtained from the City Public Works Dept. Prior to final acceptance provide a copy of the backflow test report to the City's Cross -Connection Control Specialist. Test reports can be faxed to 425.744.6057 or e-mailed to jeff.koblyk@edmondswo.gov. Bockflow testing will be required on an annual basis thereafter. 0 7.5 15 30 60 �ffl M:M% 265 Winslow Way East Suite 202D Bainbridge Island Washington 98110 telephone 206 842 1253 e-mail fronk@3rkorchitecture.com CONSULTANTS: CO t'\\ LL 0OU CS O Z fJ LU Uj QSW w U �►(/ o o LL g g TG LA, LLC Landscape Architect LANDSCAPE PLAN SCALE: 1 "=30'-0" ISSUE DATE: 1,31.19 REVISIONS: / ' \ 04.24.19 PERMIT REVISIONS 07.11.19 OWNER REVISIONS /3\ 08.23.19 PERMIT REVISIONS 4 A 12.06.19 PERMIT REVISIONS A03.20.20 PERMIT REVISIONS A05.14.20 HYUNDAI REVISIONS CONSTRUCTION SET L 1 0 ■ REVISION 4 JUN 2 4 2020 511JILDING DEPARTMENT cnY OF EDMONDS