REV 5 C5.01-3 WATER PROFILEPORTION OF THE SW 1/4, NE 1/4, SEC. 29, TWP 27 N., RGE. 4 E., W.M. O O O O O O m m N N .. N N O O O O O O O O w N N N N N N N N O� 6� 00 00 N N 0 co co co u') U-) N � 3 t i3,11" 370 365 ]HYUNDAI SALES Sc 360 SERVICE BUILDING 355 350 FF=355.10 EXISTING GRADE AT PIPE CENTERLINE — — — — — — — — — — — \_ EX. 6" SD IE=351. 19 LF 6" WA TOP=350.78 6" DI C� l f 94 LF 6" DI CL52 163 LF 6" DI CL52 PIV W/ (MJ) MEGA LUGS DOUBLE DETECTOR CHECK ASSEMBLY IN VAULT PER WA-142B SEE SHEET C5.10-3 ----- 5 LF 6" DI CL52 11 LF 6 DI CL52 --\ 0 10 LF 6" DI SPOOL (MJ W/MEGA LUGS) 20' - INSTALL MEGA LUGS EXISTING 12" STORM MAIN 5 LF 6" DI SPC (MJ W/MEGA LU �I A SEE MECHANICAL a FOR CONTINUATION 345 0 o o o cV m 0 0 C) w O w ± w Lu 00 m Li O r� m m coo m N mN N z Q Q d ALL HORIZONTAL BENDS N\ rn r) w 0 cn cn REQUIRE THRUST BLOCKING PER COE Q d Q> d d z CA An STD DETAIL WA-150, SEE SHEET C5.10-3 n N n m n 0- n C.o n 340 -0+25 kfol: AZ 0+00 [TEST COCKS W/ PVC PLUGS (4 REQ'D) RESILIENT SEATED SHUTOFF VALVES (2 REQ'D) FAIN 12" CLEARANCES AROUND ADEQUATE GRAVITY DRAINAGE BACKFLOW PREVENTER - 12" MIN SYSTEM REQUIRED ALL SIDES, TOP AND BOTTOM 5' MAX W/ APPROVED AIR GAP GROUND/TLOOR NOTES: SIDE VIEW 1. APPROVED REDUCED PRESSURE BACKFLOW ASSEMBLY TO LAY HORIZONTAL ONLY, 2. DESIGNED FOR BACK SIPHONAGE AND BACK PRESSURE, 3. THOROUGHLY FLUSH LINES PRIOR TO INSTALLATION OF BACKFLOW PREVENTER. 4. DO NOT INSTALL IN AN AREA SUBJECT TO FLOODING. 5. MUST BE ACCESSIBLE. 6. MUST BE PROTECTED FROM FREEZING CONDITIONS. 7. THE BACKFLOW ASSEMBLY SHALL BE A STATE APPROVED MODEL. 8. A PLUMBING PERMIT I$ REQUIRED - PLEASE CONTACT DEVELOPMENT SERVICE$ DEPARTMENT. 9. MUST BE TESTED AFTER INSTALLATION AND YEARLY THEREAFTER BY WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST RESULTS MUST BE SENT TO THE CITY OF EDMONDS WATER DIVISION. (ABOVE GROUND INSTALLATION ONLY) REVISION DATE CITY OF EDMONDS REDUCED PRESSURE JANUARY 2018 BACKFLOW ASSEMBLY 2" PUBLIC WORKS AND SMALLER (RPBA) STANDARD DEPARTMENT DETAIL APPROVED BY- R. ENGLISH WA-1 60A 1+00 FIRE SERVICE PROFILE SCALE: H: 1 "=20' V: 1 "=5' 2+00 ENCLOSURE "HOT BOX" OR EQUAL REDUCED PRESSURE BAGKFLOW ASSEMBLY (RPDA) 0 120 VOLT ELECTRICAL OUTLET FOR HEAT TAPE. INSTALL HEAT TAPE FOR FREEZE PROTECTION. IF RPDA, USE SENSUS SR2 �� 3" MIN METER W/ TRPL REMOTE IF RPDA, USE READ. TRPL SHALL BE SENSUS SR2 120 VOLT INSTALLED ON SIDE OF HOT z METER W/ TRPL LECTR ELECTRICAL ELECTRTLET BOX WITH EASY ACCESS REMOTE READ FOR HEAT FOR METER READING. TAPE. INSTALL UNION UNION CENTER BACKFLOW- —HEAT TAPE FOR 3" FAIN r PREVENTER IN FREEZE 3/8"x4" ANCHOR BOLTS ENCLOSURE S01 PROTECTION. (PER MANUFACTURER) I - — 3" MIN CONCRETE SLAB 2 ORAIN (2000 P51 MIN) SEE NOTE 6 iv c� 4" MIN �2 FINISHED GRADE 6" MIN PVC PVC SLEEVE 6X6 FREE DRAINING GRAVEL SLEEVE (Typ) W2.8xW2,9 WWF (TYp) (WELDED WIRE TYPE K COPPER � SUPPORTS FABRIC) OR APPROVED 'm TYPE K COPPER (Q PAL (SIZE A5 REQ) OR APPROVED r� EQUAL (SIZE AS REd) CONNECT TO WATER (TYP) METER IMMEDIATELY ADJACENT TO RPBA FLOW TO OWNERS ELECTRICAL PANEL DIRECT BURIAL OR IN RIGID CONDUIT PER ELECTRICAL PERMIT REQUIREMENTS NOTES: SIDE VIEW FRONT VIEW (METER SIDEi 1, PROVIDE CITY APPROVED SUPPORT FOR DEVICES LARGER THAN I" DIAMETER. 2. OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE RPBA OR RPDA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN, 3. MUST BE TESTED AFTER INSTALLATION AND YEARLY BY A WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST RESULTS MUST BE SENT TO THE CITY OF EDMONOS WATER DMSION. 4. REDUCED PRESSURE BACKFLOW ASSEMBLIES SHALL BE STATE APPROVED DEVICES. 5. ANNUAL TESTING OF RPBA AND RPDA REQUIRED BY OWNER. TEST RESULTS SHALL BE SENT TO THE CITY OF EDMONDS PUBLIC WORKS, 6. DRAIN SHALL BE SIZED IN ACCORDANCE WITH AWWA CROSS CONNECTION CONTROL FIGURE 6-8 (SEE COE STD DTL WA- i60C). 7. ENCLOSURES SHALL BE LOCATED ON PRIVATE PROPERTY. 8. SLEEVE SHALL BE ONE NOMINAL SIZE DIAMETER LARGER THAN PIPE BFJNG SLEEVED, REVISION DATE HOT BOX ASSEMBLY FOR JANUARY 2018 CITY OF EDMONDS EDUCED PRESSURE BACKFLOW PUBLIC WORKS ASSEMBLY (RPBA AND RPDA) S'FANDARD DEPARTMENT DETAI Lit APPROVED BY R. ENGLISH WA — 1 6 B EXIST WATER MAIN SEE COE STD DTL WA-180 2" DOMESTIC SERVICE (COPPER) 4" (MIN) FIRE UNE (DIP) {RESILIENT GATE VALVES (lYP) SEE COE STD DTLS WA-180 AND WA-181 NOTES (BLDGS PROPERTY LINE CURB SIDEWALK SETBACK LINE WM '4. A FDC PIV I 370 365 360 345 340 3+40 DCDA & VAULT SEE COE STD DTLS WA-142A & WA-142B f i BLDG i 1 1. THE DCDA AND VAULT SHALL BE LOCATED ON PRIVATE PROPERTY AND ADJACENT TO THE RIGHT-OF-WAY LINE. 2. THE PIV AND FDC SHALL BE LOCATED ON PRIVATE PROPERTY AND SHALL BE NEAR THE DCDA. 3. THE PIV AND FDC SHALL HAVE A 3' MINIMUM CLEARANCE BETWEEN AND AROUND THEM. 4, THE FDC SHALL HAVE A 22' BEND WITH 4" STORZ ADAPTER ON THE END. FIRE LINE AND 2" DOMESTIC REVISION Nu RY 2018 CITY OF EDMONDS SERVICE CONNECTIONS (PLAN VIEW) PUBLIC WORKS ALL ZONES EXCEPT ZERO —SETBACK STANDARD DEPARTMENT BUSINESS/COMMERCIAL DAETA184 IL ,1 APPROVED BY: R. ENGLISH A- 1 84 cV cV Q Q mm N co I Nrf I rON J J cn zzzzzzQQz o000000 z �n U5 v-) 7 7 U5 w ��������cU w of of of lif wwo w w w w w w w w a a m a a 0- a- a- ©mm m T m o z m 6 O o O U c C 2'CD o p u) C° Fn is > 0 ---10 m U � Q 7-- Q c 0 p,P'o; TON Fq, �SSIONA'l �1��1202� YI W 00 a Q cn O O U U 1 O w I U) O 00 O m U Ul � OLn U X 3 O Q m Al O � ■ Q 0 z � >_ Z:) w _ F-- cf) = U O o Q ui = 0 M oo z rn ` ¢ Q o� CD w z=cnz QU LL Q ` w Q o O z]- r,jO 0 z H Z Q � L5 U W \U_ N/ L.L Lu W 3 � W (D J 0. = v ) ,VI— ILu 0 N 1 Z N Q CALL BEFORE YOU D;G 811 UNDERGROUND SERVICE (USA) APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY: CITY ENGINEERING DIVISION C5.01-31 PERMIT #BLD20190120