Loading...
REVIEWED BLD2022-0015+HEATING+1.6.2022_8.27.48_AM+2605981Simple Heating System Size: Washington State REVIEWED This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washin on State Energy Code e4efin and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling syst sssshould be used to din ne cooling loads. n Please complete the green drop -downs and boxes that are applicable to your project. As you makes IeR�yr� ih the dQFnEle���R�jplh� obi values will be calculated for you. If you do not see the selection you need in the drop -down options, p ase contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information NORTON RESIDENCE GARAGE AND GUEST ROOM H2D ARCHITECTURE+ DESIGN 812 CARY RD 23020 EDMONDS WAY #113 EDMONDS, WA98020 EDMONDS, WA98020 Heating System Type: O All other Systems O Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions" BLD2022-0015 Design Temperature Instructions Design Temperature Difference (AT) Select closest city J AT =Indoor (70 degrees) -Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 348 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height 1 11.5 3,997 Glazing and Doors U-Factor X Area = UA Instructions - I 0.280 60 16.66 Skylights U-Factor X Area = UA Instructions 0.50 F__0 —1 --- Insulation Attic U-Factor X Area = UA Instructions select R-Value . No selection F__0 —1 --- Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions R-38vented 0.027 348 9.40 Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions R-21 intermediate I 0.056 J 838 46.93 Floors U-Factor X Area UA Instructions No Floors above unconditioned spaces � J --- Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions R_21Interior 0.042 126 5.29 Slab Below Gradee Figure 1) F-Factor X Length UA Instructions No Slab Below Grade in this project. � 0.303 F Slab on Grade (seefR-, re 1) F-Factor X Length UA Instructions o Fully Insulated 0.360 348 125.28 Location of Ducts Instructions Duct Leakage Coefficient No Ducts 1.00 Sum of UA 203.56 Figure 1. Above Grade RECEIVED Jan 07 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Envelope Heat Load Btu / Hour Sum of UA x AT Air Leakage Heat Load Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump (07101113)