Loading...
APPROVED BLD REV1 BLD2022-0403+Structural_Plan+6.27.2022_1.17.44_PM+2956291(E) FOOTING I I STRUCTURAL NOTES DESIGN AND CONSTRUCTION SHALL CONFORM TO THE 2018 INTERNATIONAL BUILDING CODE (IBC). — — — — — — — — — — — — IF — -- — — — -- — F—! — I — -- — — — -- — H — — -- — — — — -- — I� — — — — — — — -- �I CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO THE START OF ! CONSTRUCTION. II I I I I I i I CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURAL COMPONENTS OF THE I I I I I I I HATCHED AREA INDICATES NEW AND EXISTING STRUCTURE UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN I RM R ARCH ACCORDANCE WITH THE PLANS. II I I I I I I AT EXDISTNG GOARAGE II I I I I I ! I CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, II I I I I I I �I TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM HIS WORK. II I I I I ! I I DESIGN LOADS II I ! I ! I I I FLOOR LL 40 PSF I I I I I FLOOR DL 15 PSF II I I I I I! 3/s1 I I� 2x8 @ 16"oc I I I I I I � {� NOTES: 1. SEE ARCH FOR DIMENSIONS. CARPENTRY POST - 6X, 8X DOUG-FIR #1, Fb = 1200 PSI FRAMING - 2X, 4X HEM -FIR #2, Fb = 850 PSI � T 2. SEE ARCH FOR EXTENT OF REMODEL WORK; GLU-LAM 24F-V4 CONTRACTOR TO VERIFY (E) STRUCTURE IS AS SHOWN. 1 3/S1 I I 6/S1 LSL Fb = 2325 PSI, E = 1.55E6 li I I TYP I I I I I II I FRAMING HARDWARE DESIGNATIONS ARE SIMPSON STRONG -TIE. USE FULL AMOUNT OF FASTENERS fi I I I SPECIFIED BY MFR. HARDWARE IN CONTACT WITH PRESERVATIVE TREATED WOOD SHALL BE Z-MAX it I I I I. �(E) OR HOT -DIPPED GALVANIZED. FOOTING FRAMING NAILING SHALL CONFORM TO TABLE 2304.10.1 2018 E FOOTING O (E) CONCRETE OF THE IBC LINO. II I I ! SLAB -ON -GRADE tADE I I I I I (N) PONYWALL, TYP. I I I I HEADERS SHALL BEAR ON 2 2X TRIM STUDS. ( ) 5 LOCATIONS TOTAL II I I ! I ! I (E) CONCRETE SLAB -ON -GRADE, II II II CONTRACTOR TO VERIFY SLAB IS MIN. 6" THICK & IS REINFORCED EQ I I I ICI I I I I I I I EQ� EQ I ti (E) FOOTING PARTIAL FOUNDATION PLAN Y2"=1'-0" 5 STRUCTURAL GENERAL NOTES 2 REVISED PLAN APPROVED (N) EDGE NAILING CITY OF EDMONDS BUILDING DIVISION (N) 2x CONT LEDGER D TO SNAILS STUDS W. � p�Q� E EXTERIOR WALL () W/ MINATTACHE (3) Od BUILDING OFFICIAL (N) %" PLYWOOD Jul 06 2022 (N) EDGE NAILING (N) 2x BLKG APPROVED DATE ; (N) 34" PLYWOOD (N) SIMP LUS HANGER - The following documentation shall be available on OR EQUIV. ■ site for the building inspector: � EXTERIOR GRADE (N) JOIST PER PLAN ■ I II II I II I II I II I II I II i (N) PONYWALL PER PLAN, APPROVED - ❑ COE APPROVED ARCHITECTURAL PLAN SET ! PT 2x4 STUDS ® 16" oc W/ (E) CONCRETE STEMWALL PT DOUBLE TOP PLATES PLANS MUST BE - ■ ❑ COE APPROVED STRUCTURAL PLAN SET ! (N) JOIST PER PLAN N PONYWALL PER PLAN () (E) CONCRETE SLAB -ON -GRADE, ON JOB SITE - ❑ COE REVIEWED CALCULATION PACKET i (N) PT 2x4 BOT PL WITH 2x4 STUDS @ 16" oc W/ DOUBLE TOP PLATES (N) PT 2x4 BOT PL WITH CONTRACTOR TO VERIFY SLAB IS Y"O EXPANSION ANCHORS MIN. 6" THICK & IS REINFORCED ■ ❑ ENERGY CREDIT WORKSHEET Y"0 EXPANSION ANCHORS (E) CONCRETE SLAB -ON -GRADE @ 48" oc (4" EMBED MIN) ❑ SITE PLAN 48" oc (4" EMBED MIN) CONTRACTOR TO VERIFY SLAB IS MIN. 6" THICK & IS REINFORCED ALL WORK SUBJECT ■ ❑ CIVIL PLAN III—III=1 1-1 1= =Ii1=lil=lil=1� TO FIELD ■. ® APPROVED EXISITNG STRUCTURAL PLANS ■ ! � (E) FOOTING INSPECTION FOR ■ CODE COMPLIANCE ■ j III=III=1 � 1=1 -III1III-III1 � 1= i ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 III=1 I I=1 I I=1 I I=. =1 I-1 1=1 I-1 i' 12 9 PONYWALL DETAIL AT PLATFORM 1"=1'-0" 6 RAISED PLATFORM DETAIL 1"=1'-0" 3 /AM\/\/\ ENGINEERING 5053 Mithun PI NE Seattle WA 98105 Phone: 206.501.5149 Email: asrade@amengineenng.works STAMP ME0G''1 -'e< y OvWASAr ?' 46161 NNAL'P �1111111111PROJEC W V Z W J a W Cno W 0 W2 Cl) LU W W V O 2 �1111111111REVISIO NO. DATE 6/27/22 22-125 DATE JOB # AM AM DESIGN CHECKED AM AS NOTED DRAWN SCALE � JURISDICTION STAMP � BLD2022-0403 REVISION Jun 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT �1111111111SHEET TIT PLANS, DETAILS & NOTES SHEET NO. S1