Loading...
BLD2023-0520_Site_Plan_4.27.2023_1.49.10_PM_3509973DIRECTORY OF PLAN PAGES Brookmere Dr rvo ImI I/A mi CIVI rLHIN 3 D Vista PI s < Z Vista Way 4 903 12th PI N, Edmonds, WA 98020 CD O Q- p 200th St PV-6A UNIRAC FLASHLOC RM DATASHEET PV-6B UNIRAC FLASHLOC RM INSTALLATION PV7 RACKING DATASHEET PV8 PV MODULE DATASHEET PV9 MICROINVERTER DATASHEET PV10 CLASS A FIRE RATING DATASHEET PV11 STATE OF WASHINGTON ENGINEERING LETTER (IRONRIDGE RACKING) PV12 1GROUNDING DETAILS (IRON RIDGE RACKING) PV13 RAPID SHUTDOWN DATASHEET PV14 JENPHASE IQ COMBINER 4 DATASHEET PROJECT DETAILS PROPERTY OWNER DOUG COBURN PROPERTY ADDRESS 90312TH PL N EDMONDS, WA 98020 Cascade Dr �J 7 AHJ CITY OF EDMONDS ZONING RESIDENTIAL CONST. TYPE FLUSH ROOF -MOUNTED PHOTOVOLTAIC ARRAY OBSERVED CODES 2020 NATIONAL ELECTRICAL CODE (NEC) 2020 WASHINGTON ADMINISTRATIVE CODE (WAC) 2018 WASHINGTON STATE ENERGY CODE- RESIDENTIAL 2018 INTERNATIONAL CODES 9� 3 3 Z 7� 0 REVISED CODE OF WASHINGTON (RCW) 2. 0 > OO- D Q WASHINGTON BUILDING CODE & STATE AMENDMENTS < Sierra PI CV APPLICABLE CITY CODE WHEN PRESENT 202nd PI Su\ OSHA 29 CFR 1910,269 UNDERWRITERS LABORATORIES (UL) STANDARDS - — N Z STRUCT.METHOD ASCE7-16 CONTRACTOR INFORMATION CONTRACTOR SOLTERRA GLOBAL, LLC. LICENSE NO. SOLTEGL838BS ADDRESS 2909 1 ST AVENUE S SEATTLE, WA 98134 PHONE (425) 921-0457 CONTRACTOR SIGNATURE PLAN DESIGNER INFORMATION COMPANY GEMINI SOLAR DESIGN, LLC. NAME SANJAY CHRISTOPHER MALLIPUDI ADDRESS 495 HOWARD HEIGHTS ROAD FRESHWATER, CA 95503 PHONE (609) 802-5743 PLAN DESIGNER SIGNATURE SYSTEM DETAILS DC RATING OF SYSTEM 112,30OW AC OUTPUT CURRENT 143.5A MICROINVERTER (30) ENPHASE 108A-72-2-US MODULE (30) REC SOLAR REC410AA PURE BRANCH CONFIGURATION 3 BRANCHES OF 10 MICROINVERTERS INTERCONNECTION LOAD -SIDE TAP SITE SPECIFICATIONS UTILITY SERVICE 1201240VAC, 1-0, 3-WIRE (NEM METER / MAIN SERVICE PANEL 200A RATED BUSBAR 200A / 2P MAIN BREAKER ASHRAE EXTREME ANNUAL MEAN MINIMUM DENSITY DRY BULB TEMP. -7'C ASHRAE 2%ANNUAL DRY DENSITY BULB TEMP. 29°C DESIGN WIND SPEED 110 MPH DESIGN SNOW LOAD 15 PSF WIND EXPOSURE CATEGORY B RISK CATEGORY III Bay Sot eh,�9hwa y 1O 5 t Walker Dabob Bay Hood Canal O 1 PLOT PV-1 SCALE: NTS 0 JIeVeMS Possession Sound Everett © 2 15261 Mukilteo s25) Eastmont North Mill Lynnwood Creek Puget Sound 10 Lynnwood 903 12th PI N, Kingston Edmonds, WA 98020 In Shoreline Bothell Poulsbo Bangor Cottage Lake Bangor Base NON Kirkland Redmont' 1pd:.M III �/ 1 Ili Island MAN ►� State Route 2 CONSTRUCTION NOTES CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS 1 PRIOR TO INITIATING CONSTRUCTION. CONTRACTOR SHALL REVIEW ALL MANUFACTURER 2 INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. ALL EQUIPMENT SHALL BE LISTED BY THE U.L. (OR 3 EQUAL) AND LISTED FOR ITS SPECIFIC APPLICATION. 4 ALL EQUIPMENT SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE 5 WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. ACCESS TO ELECTRICAL COMPONENTS OVER 150 6 VOLTS TO GROUND SHALL BE RESTRICTED TO QUALIFIED PERSONNEL. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 7 VOLTS AND 90°C WET ENVIRONMENT, UNLESS OTHERWISE NOTED. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND 8 CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL SIZE THEM ACCORDING TO APPLICABLE CODES. PV MODULES FRAMES SHALL BE BONDED TO RACKING 9 RAIL OR BARE COPPER G.E.C. PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. PV MODULES RACKING RAIL SHALL BE BONDED TO 10 BARE COPPER G.E.0 VIA WEEB LUG, ILSCO GBL-4DBT LAY -IN LUG, OR EQUIVALENT LISTED LUG. 11 GROUNDING ELECTRODE CONDUCTOR (G.E.C) SHALL BE CONTINUOUS AND/OR IRREVERSIBLY SPLICED ALL JUNCTION BOXES, COMBINER BOXES, AND 12 DISCONNECTS SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION. 13 WORKING SPACE AROUND ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC SECTION 110.26. SCOPE OF WORK DESCRIPTION THE PROPOSED SYSTEM IS A ROOF MOUNTED PHOTOVOLTAIC ARRAY UTILIZING MICROINVERTERS. THE PHOTOVOLTAIC (PV) SYSTEM IS TO BE INSTALLED ON THE RESIDENTIAL ZONED PROPERTY IN THE CITY OF EDMONDS, WASHINGTON. THE ENERGY PRODUCED BY THE PV SYSTEM SHALL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ON -SITE ELECTRICAL EQUIPMENT VIA A LOAD -SIDE TAP POINT OFINTERCONNECTION. THIS PROJECT DOES NOT INCLUDE STORAGE BATTERIES. PHONE: 206 462-1103 LICENSE NO. SOLTEGL838BS CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. 0 CM CV LiJ o � U o LU Z L•LJ � Oi Q L U Cn Z C) Mo H O Q C) U LU CD W Z PROJECTINFO DRAWN BY: SCM DATE: 4/19/2023 PV_ 1 AREA OF ALL PV ARRAYS: 600 SQ. FT AREA OF ROOF SURFACE: 2,975 SQ. FT SOLAR PERCENT COVERAGE: -20.2% E PROPERTY LINE I I I I I I I I I I 95' I I I I I I I I I I I L- 1 BRANCH OF 10 MICROINVERTERS (ENPHASE MA-72-2-US) 1 BRANCH OF 10 MICROINVERTERS (ENPHASE MA-72-2-US) 1 BRANCH OF 10 MICROINVERTERS (ENPHASE IQ8A-72-2-US) (N) 200A METER 1 MAIN SERVICE (N) 200A 12P MAIN BREAKER 120 1 240VAC - 1 ¢ - 3W - NEMA 3R N) LOAD -SIDE TAP POINT OF INTERCONNECTION AS PER NEC 240.21(B)(1) 8 NEC 705.12(A) (TO TAKE PLACE WITHIN THIS ENCLOSURE) (LOC. ON EXTERIOR) (N) UTILITY AC DISCONNECT (DS1), 60A RATED,1-�, 3-WIRE, 2-POLE EQUIP WITH (2) X 60A FUSES, 240VAC DISCONNECT SHALL BEA VISIBLE, LOCKABLE, KNIFE SWITCH DISCONNECT AS PER UTILITY MEANS OF DISCONNECTION FOR THE LOAD -SIDE TAP POINT OF CONNECTION (LOC, ON EXTERIOR) 50 40'-3" 1 DWELLING I I I I SITE PLAN NOTES CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT 1 RESISTANT PER NEC 319.0(D). 2 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC 310.8(C). 3 ARRAYS SHALL BE INSTALLED IN A WAY THAT ENSURES THAT PV SOURCE CONDUCTORS SHALL NOT BE READILY ACCESSIBLE. SOLTERRA GLOBAL, LLC. PHONE: 206 462-1103 LICENSE NO. SOLTEGL838BS CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. O M GV Lu o U o uj op W 07) U J O Q W = 0 N C/) Z � � uj ZD o CDm rn O 0 C7 L1J Z A SITE PLAN PV-2 SCALE: 1" = 14' SITE PLAN IRS PV-2