Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED BLD2022-1672+Building_Elevations+12.9.2022_11.20.16_AM+3261184
GENERALNOTES 1. UNIT TO BE PLACED IN SAME LOCATION ON ROOF AS THE UNIT IT IS REPLACING. 2. OTHER ROOFTOP EQUIPMENT SHOWN FOR REFERANCE ONLY. RTU-1 W, ROOF PLAN SCALE: 1/8" = 1'-0" . The following documentation shall be available on site for the building inspector: 12/8/22, 3:49 PM https://waenergycodes.com/print - V project_summary_form.php?k=aWQ9MTUwNDQmZnZpPTE3JnJIc2VOPTE=&debug=1 'E] COE APPROVED ARCHITECTURAL PLAN SET ' • MECHANICAL COMPLIANCE SUMMARY ■ ❑ COE APPROVED STRUCTURAL PLAN SET 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2022 NEEA, All rights reserved E] COE REVIEWED CALCULATION PACKET 1 Project Title Ivar's Edmonds RTU Replacements - 2018 WSEC For Building Department Use: Date' Dee 08 2022 I ' ■ - [:]ENERGY CREDIT WORKSHEET 1 9910Edmonds Way, Project &Applicant Information Project Address Edmonds, WA 98020 ■ ; ❑ SITE PLAN 1 Applicant Name Wayne Cornell Applicant Phone 253-872-7392 ❑ CIVIL PLAN ' Applicant Email wcornell@keymechanical.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com ❑ 3,066 - ❑ General Occupancy All Commercial I General Building Use Type Dining, Fast Food Building Cond. Floor Area General Project Types Building Addition Alteration New Building or Addition Alteration Mechanical Scope Single Zone Systems &Equipment Project Cond. Floor Area J 3,066 ■ ■ � Floors Above Grade I Mechanical Scope P Compliance Method Compliance Method 1 -General - ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ' Mechanical Project Description REMOVE/REPLACE EXISTING ROOFTOP HEAT PUMP FOR MAINTENENCE PURPOSES. Project Economizer DOAS Ventilation Higher Equipment Equipment Efficiency Mechanical Compliance Type Mechanical Scope Exception(s) � Applied. Provided. Efficiency ? Option Applied. Compliance Verification Scope and Method Alteration Single Zone Systems & Yes No NA COMPLIES Equipment Additional Efficiency Credits Included (AEC) Does building include occupancy classifications requiring No Does project include DOHS equipment? No DOAS. Based on project scope do TSPR requirements apply? No Do all systems comply with Appendix D standard reference design or qualify for an exception to N TSPR? Scope & Space Conditioning ALTERATION - SINGLE ZONE SYSTEMS & EQUIPMENT Compliance Verification COMPLIES Single Zone Air Systems Category - Heat pump, packaged (PTHP, SPVHP, room) Air Systems Summary Information System/Equip ID Quantity of Items Supply Airflow Control Ventilation Standard Ventilation CFM (Total if Multiple Items) Ventilation Air Source Paired with DOAS Ventilation energy recovery Energy Recovery Efficiency (%) RTU-I I I Variable air volume ASHRAE Standard 62.1 Other System Air Systems & Equipment - Cooling System/ Cooling System/Equip Cooling AEC Econo Exception Combined Efficiency Proposed CE Proposed Part PL Efficiency Equip Type Specific Type Capacity Efficiency Multiplier (FL & Multiplier (AEC & Cooling Units Load Units Compliance ID per item (Btu/h) Multiplier PL) Econo) Efficiency Efficiency Verification RTU-1 Heat pump, terminal (PTHP) Packaged terminal HP, replacement 63,000 1 0 1 EER COMPLIES Air Systems & Equipment - Heating System Heat Pump Heating Capacity Cooling Capacity AEC Proposed Heat HPH Proposed Low LTH Efficiency /Equip Heating System/Equip Type Specific Type (Btu/h) (Btu/h) Efficiency Pump Units OSA Units Compliance ID Multiplier Heating Efficiency Temp Efficiency Verification RTU-I Heat pump, terminal (PTHP), Packaged terminal HP, 54,000 63,000 1 80.6 COP COMPLIES heating replacement Air Systems & Equipment Details System/Equip ID Area(s) Served Location In Project Documents - Plan/Detail # https://waenergycodes.com/print_ project —Su mmary_form.php?k=aWQ9MTUwNDQmZnZpPTE3JnJIc2VOPTE=&debug=1 12/8/22, 3:49 PM https://waenergycodes.com/print_ project_summary_form.php?k=aWQ9MTUwNDQmZnZpPTE3JnJlc2VOPTE=&debug=1 1/2 RTU-1 STORE I ALL System/Equip ID for a single or multiple items?: Single item Economizer Compliance Method: Air -side economizer provided WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP WSEC COMPLIANCE NOT TO SCALE TOP OF WALL ROOF ELEVATIONS NOT TO SCALE ROOFTOP EQUIPMENT ID Make Model Control Type Static Pressure RPM H/P Voltage Phase MCA Weight (lbs) Height Base Size NEW RTU-1 CARRIER 48GCDM06A2A5 ELECTROMECHANICAL 0.6 2087.0 0.97 208 3 31 600.0 42" 7511x47" EXISTING RTU-1 CARRIER 48H DT006510 1075.0 0.5 208 3 40 685 31" 80"x44" ROOFTOP EQUIPMENT CONTINUED ID TYPE Economizer COOLING CAPACITY BTU/H R SEER HEATING CAPACITY BTU/H R CFM DB INPUT OUTPUT Thermal Eff NEW RTU-1 HEAT PUMP YES 63,000 16 67,000 54,000 80.6% 2000 79 EXISTING RTU-1 HEAT PUMP 581#000 8.1 1200000 950400 79.5% 3800 EQUIPMENT SCHEDULE B LD2022-1672 STAMP: RECEIVED 12/9/2022 CITY OF EDMONDS DEVELOPMENT m U) = N O �O 00 VJ Z W O Z � W z 00 IZT '�' ' .e REVISIONS 0 DATE DESCRIPTION T, O E 0 W c� m CD -0 � Mo CN 0 0 -Q w 0 U) E v co -0-0 U w C: O W O L Co O LU Z 0 (_ U) Lu J U U CN N LJ� Q CY) M W Z a oO a C C I_ N W p � Qo a U Lu UZ Q (] Nw 0 N K m M= Z to i U W 00 O� Q ° H 0 F- w W � Z N U LU t6 �a No U s_M Jo m ° �LU > Y : � Q Q i + SHEET NUMBER: M 1 .0 NOT TO SCALE Rooftop Plan, WSEC, Elevations, Schedule